TY - RPRT A1 - Feldmann, M. A1 - Kuhnhenne, M. A1 - Döring, Bernd A1 - Pyschny, D. A1 - Lawson, R.M. A1 - Chuter, R.D. A1 - Boudjabeur, S. A1 - Lecomte-Labory, F. A1 - Airaksinen, M. A1 - Heikkinen, J. A1 - Laamanen, J. A1 - Albart, P. A1 - D'Haeyer, R. A1 - Chica, J.A. A1 - Maseda, J.M. A1 - Amundarain, A. A1 - Rips, M.O. A1 - Nuñez, J.A. A1 - Macías, O. A1 - Beguin, P. A1 - Ben Larbi, A. T1 - Energy and thermal improvements for construction in steel (ETHICS) - EUR 26010 N2 - ETHICS is concerned with evaluating, measuring and making improvements in the thermal and energy performance of steel-clad and steel-framed buildings. It addresses basic building physics performance at a laboratory and full-scale level, and the preparation of design guidance for commercial, industrial and residential buildings. It includes the development of design tools to assist users in assessing whole-building performance, and calibrates these tools against whole-building measurements, which will be obtained from this research. Opportunities for renewable energy and other energy-saving features will be assessed. This project focuses on objectives that are of particular interest for the design of new steel constructions regarding energy efficiency. ETHICS investigates the as-built performance by on-site tests regarding air tightness and heat transfer properties of the building envelope and by monitoring the energy consumption and thermal comfort of selected up-to-date steel buildings. As energy efficiency is a key requirement for design and construction of buildings in the future, this project provides well-founded scientific data, which prove the high energy performance of current steel constructions and work out details for further improvements to maintain and extend the position of steel products in the construction sector. KW - steel KW - metal structure KW - building technique KW - energy efficiency KW - thermal insulation KW - industrial research KW - research report Y1 - 2013 SN - 978-92-79-30789-8 U6 - http://dx.doi.org/10.2777/17106 SN - 1831-9424 PB - Publications Office of the European Union CY - Luxembourg ER - TY - RPRT A1 - Lawson, R.M. A1 - Baddoo, N.R. A1 - Vanier, G. A1 - Döring, Bernd A1 - Kuhnhenne, M. A1 - Nieminen, J. A1 - Beguin, P. A1 - Herbin, S. A1 - Caroli, G. A1 - Adetunji, I. A1 - Kozlowski, A. T1 - Renovation of buildings using steel technologies (Robust) - EUR 25335 N2 - Robust addresses the renovation and improvement of existing residential, industrial and commercial buildings using steel-based technologies, focusing on techniques such as over-cladding, over-roofing and roof-top extensions. Steel-intensive renovation techniques currently on the market were reviewed. Performance criteria were developed for over-cladding systems meeting current regulatory standards, with guidelines on how to achieve appropriate levels of air-tightness. KW - iron and steel industry KW - steel KW - materials technology KW - building materials KW - metal structure KW - building safety KW - testing KW - industrial research Y1 - 2013 SN - 978-92-79-24950-1 U6 - http://dx.doi.org/10.2777/97860 SN - 1831-9424 PB - Publications Office of the European Union CY - Luxembourg ER - TY - RPRT A1 - Höttges, Jörg A1 - Vöcklinghaus, S. T1 - Generalentwässerungsplanung : Alle 10 Jahre wieder – Was ist zu beachten? Y1 - 2007 N1 - Abwasserreport ; 1.07 SP - 8 EP - 10 ER - TY - RPRT A1 - Döring, Bernd T1 - Nutzung erneuerbarer Energien in Landesbauten : Dokumentation realisierter und geplanter Anlagen Y1 - 1997 SN - 3-930860-51-1 PB - Landesinstitut für Bauwesen des Landes Nordrhein-Westfalen CY - Aachen ER - TY - RPRT A1 - Conan, Yulian A1 - D'Haeyer, R. A1 - Béguin, P. A1 - Döring, Bernd A1 - Kuhnhenne, Markus A1 - Bayo, E. T1 - Steel in low-rise building : a symbiosis of cold formed sections and light rolled profiles : final report. Contract-No. 7215-PP/070. EUR 22080 en Y1 - 2006 SN - 92-79-02082-X PB - Office for Official Publications of the European Communities CY - Luxembourg ER - TY - RPRT A1 - Kesti, J. A1 - Burstrand Knutsson, H. A1 - Salvatore, W. A1 - Saouridis, C. A1 - Odrieres Meré, J. A1 - Georgi, H. A1 - Casajus, A. A1 - Butz, C. A1 - Schneider, R. A1 - Döring, Bernd T1 - Dissemination of knowledge in the use of steel-intensive dry construction systems in housing : final report. Contract No RFS2-CT-2004-00036. EUR 22849 EN Y1 - 2008 SN - 978-92-79-05973-5 PB - Office for Official Publications of the European Communities CY - Luxembourg ER - TY - RPRT A1 - Labory, F. A1 - Cajot, L. G. A1 - Mees, C. A1 - Delcuve, F. A1 - Döring, Bernd A1 - Kuhnhenne, Markus A1 - Kesti, J. A1 - Lawson, M. A1 - Baddoo, N. A1 - Ogden, R. A1 - Griffin, A. A1 - Spasov, Y. A1 - Bonilla, A. A1 - Cagigal, E. T1 - Energy efficient buildings through innovative systems in steel : final report. Contract No RFSR-CT-2003-00017. EUR 23180 EN Y1 - 2008 SN - 978-92-79-07681-7 PB - European Communities CY - Luxembourg ER - TY - RPRT A1 - Döring, Bernd A1 - Kuhnhenne, Markus A1 - Vassart, O. A1 - Harper, C. T1 - Integrated pre-fabricated steel technologies for the multi-storey sector Y1 - 2009 SN - 9789279113192 PB - Office for Official Publ. of the European Communities CY - Luxembourg ER - TY - RPRT A1 - Kettern, Jürgen A1 - Billmaier, K. A1 - Drees, K.-T. T1 - Rotte- und Emissionsverhalten von mechanisch-biologisch vorbehandeltem Restmüll und Keim- und Staubbelastung im Sortierbereich : Abschlußbericht ; [Abschlußdatum des Vorhabens: 06/1999] N2 - Es sollte herausgestellt werden, inwieweit kalte Vorbehandlungsverfahren das Deponierverhalten von mechanisch-biologisch vorbehandeltem Restmüll beeinflussen. Das Deponierverhalten von mechanisch-biologisch vorbehandeltem Abfall wurde an Lysimeterversuchen simuliert. Die Ergebnisse zeigen, daß durch die mechanisch-biologische Behandlung des Abfalls eine CSB-Entfrachtung bezogen auf das Wasser-Feststoffverhältnis von ca. 70 % erfolgt, die kumulierte TOC-Fracht um ca. 50 % sinkt, die NH4-N-Konzentrationen eine Reduktion von annähernd 80 % aufweist, die Gasproduktion um ca 80 % fällt. Insgesamt kann mit einer erheblichen Verkürzung der Nachsorgephase gerechnet werden. - Neben den Lysimeteruntersuchungen wurden Staub- und Keimemmissionsmessungen im Handsortierbereich der MBRA durchgeführt. Die durchgeführten Keimemissionsmessungen ergaben, daß die dort Beschäftigten im Vergleich zu anderen Arbeitsbereichen z.T. signifikant erhöhten Keimbelastungen ausgesetzt sind. Den größten Anteil der im Screening eindeutig bestimmten Bakterien hatten die Enterobakteriaceen, die Streptomyceten sowie Coliformen. Den größten Anteil am Pilzspektrum hatte die Gruppe der Penicillien. Die Differenzierung zeigte die Eigung von A. fumigatus als Leitkeim. - Die Staubmessungen erfolgten gleichzeitig mit den Keimemissionsmessungen. Die Analyse der Partikelzahlen in den unterschiedlichen Größenklassen zeigt, daß 95 % der Aerosole einatembar, 90 % thorakal- und 85 % alveolengängig sind. Des weiteren ergab die Korrelation der Partikelklasse > 2 bis < 5 Mikrometer und der Konzentration an luftgetragenen Pilzen eine signifikante Übereinstimmung. Bei zukünftigen Untersuchungen und routinemäßigen Messungen durch die Aufsichtsbehörde oder im Rahmen der arbeitsmedizinischen Vorsorge könnte demnach auf die bewährte Meßgröße "Staubgehalt" zurückgegriffen werden. KW - Restabfall KW - MBRA KW - Müllsortierung KW - Lysimeter KW - Deponierverhalten KW - Restmüll Y1 - 1999 ER -