@article{Staat1993, author = {Staat, Manfred}, title = {Failure probabilities of the primary circuit pressure boundary of an HTR-Module for process heat generation under accident conditions for different failure modes}, series = {Nuclear Engineering and Design. 144 (1993), H. 1}, journal = {Nuclear Engineering and Design. 144 (1993), H. 1}, isbn = {0029-5493}, pages = {53 -- 67}, year = {1993}, language = {en} } @article{LapitanRogatkinPersheyevetal.2018, author = {Lapitan, Denis G. and Rogatkin, Dmitrii A. and Persheyev, Sydulla K. and Kotliar, Konstantin}, title = {False spectra formation in the differential two-channel scheme of the laser Doppler flowmeter}, series = {Biomedizinische Technik}, volume = {63}, journal = {Biomedizinische Technik}, number = {4}, publisher = {De Gruyter}, address = {Berlin}, issn = {0013-5585}, doi = {10.1515/bmt-2017-0060}, pages = {439 -- 444}, year = {2018}, abstract = {Noise in the differential two-channel scheme of a classic laser Doppler flowmetry (LDF) instrument was studied. Formation of false spectral components in the output signal due to beating of electrical signals in the differential amplifier was found out. The improved block-diagram of the flowmeter was developed allowing to reduce the noise.}, language = {en} } @article{LeimenaArtmannDachwaldetal.2010, author = {Leimena, W. and Artmann, Gerhard and Dachwald, Bernd and Temiz Artmann, Ayseg{\"u}l and Gossmann, Matthias and Digel, Ilya}, title = {Feasibility of an in-situ microbial decontamination of an ice-melting probe}, series = {Eurasian Chemico-Technological Journal. 12 (2010), H. 2}, journal = {Eurasian Chemico-Technological Journal. 12 (2010), H. 2}, isbn = {1562-3920}, pages = {145 -- 150}, year = {2010}, language = {en} } @article{TranTrinhDaoetal.2022, author = {Tran, Ngoc Trinh and Trinh, Tu Luc and Dao, Ngoc Tien and Giap, Van Tan and Truong, Manh Khuyen and Dinh, Thuy Ha and Staat, Manfred}, title = {FEM shakedown analysis of structures under random strength with chance constrained programming}, series = {Vietnam Journal of Mechanics}, volume = {44}, journal = {Vietnam Journal of Mechanics}, number = {4}, publisher = {Vietnam Academy of Science and Technology (VAST)}, issn = {0866-7136}, doi = {10.15625/0866-7136/17943}, pages = {459 -- 473}, year = {2022}, abstract = {Direct methods, comprising limit and shakedown analysis, are a branch of computational mechanics. They play a significant role in mechanical and civil engineering design. The concept of direct methods aims to determine the ultimate load carrying capacity of structures beyond the elastic range. In practical problems, the direct methods lead to nonlinear convex optimization problems with a large number of variables and constraints. If strength and loading are random quantities, the shakedown analysis can be formulated as stochastic programming problem. In this paper, a method called chance constrained programming is presented, which is an effective method of stochastic programming to solve shakedown analysis problems under random conditions of strength. In this study, the loading is deterministic, and the strength is a normally or lognormally distributed variable.}, language = {en} } @article{PhamStaat2014, author = {Pham, Phu Tinh and Staat, Manfred}, title = {FEM-based shakedown analysis of hardening structures}, series = {Asia Pacific journal on computational engineering}, journal = {Asia Pacific journal on computational engineering}, number = {1}, publisher = {SpringerOpen}, address = {Berlin}, issn = {2196-1166 (E-Journal)}, doi = {10.1186/2196-1166-1-4}, pages = {Article No. 4}, year = {2014}, abstract = {This paper develops a new finite element method (FEM)-based upper bound algorithm for limit and shakedown analysis of hardening structures by a direct plasticity method. The hardening model is a simple two-surface model of plasticity with a fixed bounding surface. The initial yield surface can translate inside the bounding surface, and it is bounded by one of the two equivalent conditions: (1) it always stays inside the bounding surface or (2) its centre cannot move outside the back-stress surface. The algorithm gives an effective tool to analyze the problems with a very high number of degree of freedom. Our numerical results are very close to the analytical solutions and numerical solutions in literature.}, language = {en} } @article{StaatHeitzer1999, author = {Staat, Manfred and Heitzer, M.}, title = {FEM-computation of load carrying capacity of highly loaded passive components by direct methods. Heitzer, M. ; Staat, M.}, series = {Nuclear Engineering and Design. 193 (1999), H. 3}, journal = {Nuclear Engineering and Design. 193 (1999), H. 3}, isbn = {0029-5493}, pages = {349 -- 358}, year = {1999}, language = {en} } @article{BaaderBoxbergChenetal.2023, author = {Baader, Fabian and Boxberg, Marc S. and Chen, Qian and F{\"o}rstner, Roger and Kowalski, Julia and Dachwald, Bernd}, title = {Field-test performance of an ice-melting probe in a terrestrial analogue environment}, series = {Icarus}, journal = {Icarus}, number = {409}, publisher = {Elsevier}, address = {Amsterdam}, doi = {10.1016/j.icarus.2023.115852}, pages = {Artikel 115852}, year = {2023}, abstract = {Melting probes are a proven tool for the exploration of thick ice layers and clean sampling of subglacial water on Earth. Their compact size and ease of operation also make them a key technology for the future exploration of icy moons in our Solar System, most prominently Europa and Enceladus. For both mission planning and hardware engineering, metrics such as efficiency and expected performance in terms of achievable speed, power requirements, and necessary heating power have to be known. Theoretical studies aim at describing thermal losses on the one hand, while laboratory experiments and field tests allow an empirical investigation of the true performance on the other hand. To investigate the practical value of a performance model for the operational performance in extraterrestrial environments, we first contrast measured data from terrestrial field tests on temperate and polythermal glaciers with results from basic heat loss models and a melt trajectory model. For this purpose, we propose conventions for the determination of two different efficiencies that can be applied to both measured data and models. One definition of efficiency is related to the melting head only, while the other definition considers the melting probe as a whole. We also present methods to combine several sources of heat loss for probes with a circular cross-section, and to translate the geometry of probes with a non-circular cross-section to analyse them in the same way. The models were selected in a way that minimizes the need to make assumptions about unknown parameters of the probe or the ice environment. The results indicate that currently used models do not yet reliably reproduce the performance of a probe under realistic conditions. Melting velocities and efficiencies are constantly overestimated by 15 to 50 \% in the models, but qualitatively agree with the field test data. Hence, losses are observed, that are not yet covered and quantified by the available loss models. We find that the deviation increases with decreasing ice temperature. We suspect that this mismatch is mainly due to the too restrictive idealization of the probe model and the fact that the probe was not operated in an efficiency-optimized manner during the field tests. With respect to space mission engineering, we find that performance and efficiency models must be used with caution in unknown ice environments, as various ice parameters have a significant effect on the melting process. Some of these are difficult to estimate from afar.}, language = {en} } @article{NovacekTranKlingeetal.2012, author = {Novacek, V. and Tran, Thanh Ngoc and Klinge, U. and Tolba, R. H. and Staat, Manfred and Bronson, D. G. and Miesse, A. M. and Whiffen, J. and Turquier, F.}, title = {Finite element modelling of stapled colorectal end-to-end anastomosis : Advantages of variable height stapler design}, series = {Journal of Biomechanics}, volume = {45}, journal = {Journal of Biomechanics}, number = {115}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-2380}, doi = {10.1016/j.jbiomech.2012.07.021}, pages = {2693 -- 2697}, year = {2012}, abstract = {The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge.}, language = {en} } @article{DachwaldSchmidtSeboldtetal.2003, author = {Dachwald, Bernd and Schmidt, Tanja D. and Seboldt, Wolfgang and Auweter-Kurtz,}, title = {Flight Opportunities from Mars to Earth for Piloted Missions Using Continuous Thrust Propulsion / Schmidt, Tanja D. ; Dachwald, Bernd ; Seboldt, Wolfgang ; Auweter-Kurtz, Monika}, publisher = {-}, pages = {1 -- 9}, year = {2003}, language = {en} } @article{ScholzLeyDachwaldetal.2010, author = {Scholz, A. and Ley, Wilfried and Dachwald, Bernd and Miau, J. J. and Juang, J. C.}, title = {Flight results of the COMPASS-1 picosatellite mission}, series = {Acta Astronautica. 67 (2010), H. 9-10}, journal = {Acta Astronautica. 67 (2010), H. 9-10}, isbn = {0094-5765}, pages = {1289 -- 1298}, year = {2010}, language = {en} } @article{JungStaatMueller2013, author = {Jung, Alexander and Staat, Manfred and M{\"u}ller, Wolfram}, title = {Flight style optimization in ski jumping on normal, large, and ski flying hills}, series = {Journal of biomechanics}, volume = {Vol. 47}, journal = {Journal of biomechanics}, number = {Iss. 3}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-2380 (E-Journal); 0021-9290 (Print)}, pages = {716 -- 722}, year = {2013}, language = {en} } @article{ArtmannHueckRossiteretal.2008, author = {Artmann, Gerhard and Hueck, Isgard S. and Rossiter, Katharine and Schmid-Sch{\"o}nbein, Geert W.}, title = {Fluid Shear Attenuates Endothelial Pseudopodia Formation into the Capillary Lumen / Hueck, Isgard S. ; Rossiter, Katharine ; Artman, Gerhard M. ; Schmid-Sch{\"o}nbein, Geert W.}, series = {Microcirculation. 15 (2008), H. 6}, journal = {Microcirculation. 15 (2008), H. 6}, isbn = {1549-8719}, pages = {531 -- 542}, year = {2008}, language = {en} } @article{DigelDemirciTemizArtmannetal.2004, author = {Digel, Ilya and Demirci, Taylan and Temiz Artmann, Ayseg{\"u}l and Nishikawa, K.}, title = {Free Radical Nature of the Bactericidal Effect of Plasma-Generated Cluster Ions (PCIs)}, series = {Biomedizinische Technik. 49 (2004), H. Erg.-Bd. 2}, journal = {Biomedizinische Technik. 49 (2004), H. Erg.-Bd. 2}, isbn = {0932-4666}, pages = {982 -- 983}, year = {2004}, language = {en} } @article{StadlerDigelEmbsetal.2009, author = {Stadler, Andreas M. and Digel, Ilya and Embs, Jan P. and Unruh, Tobias and Tehei, M. and Zaccai, G. and B{\"u}ldt, G. and Artmann, Gerhard}, title = {From powder to solution : Hydration dependence of human hemoglobin dynamics correlated to body temperature}, series = {Biophysical Journal. 96 (2009), H. 12}, journal = {Biophysical Journal. 96 (2009), H. 12}, publisher = {Cell Press}, address = {Cambridge, Mass.}, isbn = {0006-3495}, pages = {5073 -- 5081}, year = {2009}, language = {en} } @article{ArtmannZang1990, author = {Artmann, Gerhard and Zang, Werner}, title = {Fully automatic measurement of rheologic parameters of red blood cells = Laborautomat zur Messung mechanischer Eigenschaften roter Blutzellen}, series = {Biomedizinische Technik = Biomedical engineering. 35 (1990), H. Suppl. 3}, journal = {Biomedizinische Technik = Biomedical engineering. 35 (1990), H. Suppl. 3}, isbn = {0013-5585}, pages = {94 -- 96}, year = {1990}, language = {en} } @article{KotliarNagelVilseretal.2008, author = {Kotliar, Konstantin and Nagel, Edgar and Vilser, Walthard and Lanzl, Ines M.}, title = {Functional in vivo assessment of retinal artery microirregularities in glaucoma / Kotliar, Konstantin E. ; Nagel, Edgar ; Vilser, Walthard ; Lanzl, Ines M.}, series = {Acta Ophthalmologica. 86 (2008), H. 4}, journal = {Acta Ophthalmologica. 86 (2008), H. 4}, publisher = {-}, isbn = {1755-3768}, pages = {424 -- 433}, year = {2008}, language = {en} } @article{SeidovaKotliarFoergeretal.2009, author = {Seidova, Seid-Fatima and Kotliar, Konstantin and Foerger, Frauke and Klopfer, Matthias and Lanzl, Ines}, title = {Functional retinal changes in Gaucher disease}, series = {Documenta Ophthalmologica}, volume = {118}, journal = {Documenta Ophthalmologica}, number = {2}, publisher = {Springer}, address = {Berlin}, isbn = {1573-2622}, pages = {151 -- 154}, year = {2009}, language = {en} } @article{DachwaldTuryshevDittusetal.2005, author = {Dachwald, Bernd and Turyshev, Slava G. and Dittus, H. and Shao, M. [u.a.]}, title = {Fundamental Physics with the Laser Astrometric Test Of Relativity / S.G. Turyshev ; H. Dittus ; M. Shao ... B.Dachwald ...}, series = {Proceedings of the 39th ESLAB Symposium "Trends in Space Science and Cosmic Vision 2020" : 19 - 21 April 2005, ESTEC, Noordwijk, the Netherlands / European Space Agency. [Comp. by: F. Favata ...] . - (ESA SP ; 588)}, journal = {Proceedings of the 39th ESLAB Symposium "Trends in Space Science and Cosmic Vision 2020" : 19 - 21 April 2005, ESTEC, Noordwijk, the Netherlands / European Space Agency. [Comp. by: F. Favata ...] . - (ESA SP ; 588)}, publisher = {ESA Publ. Div.}, address = {Noordwijk}, isbn = {9290928999}, pages = {8 -- 11}, year = {2005}, language = {en} } @article{RichterBraunsteinStaeudleetal.2021, author = {Richter, Charlotte and Braunstein, Bj{\"o}rn and St{\"a}udle, Benjamin and Attias, Julia and S{\"u}ss, Alexander and Weber, Tobias and Mileva, Katya N. and Rittweger, J{\"o}rn and Green, David A. and Albracht, Kirsten}, title = {Gastrocnemius medialis contractile behavior during running differs between simulated Lunar and Martian gravities}, series = {Scientific reports}, volume = {11}, journal = {Scientific reports}, number = {Article number: 22555}, publisher = {Springer Nature}, address = {London}, issn = {2045-2322}, doi = {10.1038/s41598-021-00527-9}, pages = {13 Seiten}, year = {2021}, abstract = {The international partnership of space agencies has agreed to proceed forward to the Moon sustainably. Activities on the Lunar surface (0.16 g) will allow crewmembers to advance the exploration skills needed when expanding human presence to Mars (0.38 g). Whilst data from actual hypogravity activities are limited to the Apollo missions, simulation studies have indicated that ground reaction forces, mechanical work, muscle activation, and joint angles decrease with declining gravity level. However, these alterations in locomotion biomechanics do not necessarily scale to the gravity level, the reduction in gastrocnemius medialis activation even appears to level off around 0.2 g, while muscle activation pattern remains similar. Thus, it is difficult to predict whether gastrocnemius medialis contractile behavior during running on Moon will basically be the same as on Mars. Therefore, this study investigated lower limb joint kinematics and gastrocnemius medialis behavior during running at 1 g, simulated Martian gravity, and simulated Lunar gravity on the vertical treadmill facility. The results indicate that hypogravity-induced alterations in joint kinematics and contractile behavior still persist between simulated running on the Moon and Mars. This contrasts with the concept of a ceiling effect and should be carefully considered when evaluating exercise prescriptions and the transferability of locomotion practiced in Lunar gravity to Martian gravity.}, language = {en} } @article{RichterBraunsteinStaeudleetal.2021, author = {Richter, Charlotte and Braunstein, Bjoern and St{\"a}udle, Benjamin and Attias, Julia and Suess, Alexander and Weber, Tobias and Mileva, Katja N. and Rittweger, Joern and Green, David A. and Albracht, Kirsten}, title = {Gastrocnemius medialis contractile behavior is preserved during 30\% body weight supported gait training}, series = {Frontiers in Sports and Active Living}, volume = {2021}, journal = {Frontiers in Sports and Active Living}, number = {2}, publisher = {Frontiers}, address = {Lausanne}, issn = {2624-9367}, doi = {10.3389/fspor.2020.614559}, pages = {Artikel 614559}, year = {2021}, abstract = {Rehabilitative body weight supported gait training aims at restoring walking function as a key element in activities of daily living. Studies demonstrated reductions in muscle and joint forces, while kinematic gait patterns appear to be preserved with up to 30\% weight support. However, the influence of body weight support on muscle architecture, with respect to fascicle and series elastic element behavior is unknown, despite this having potential clinical implications for gait retraining. Eight males (31.9 ± 4.7 years) walked at 75\% of the speed at which they typically transition to running, with 0\% and 30\% body weight support on a lower-body positive pressure treadmill. Gastrocnemius medialis fascicle lengths and pennation angles were measured via ultrasonography. Additionally, joint kinematics were analyzed to determine gastrocnemius medialis muscle-tendon unit lengths, consisting of the muscle's contractile and series elastic elements. Series elastic element length was assessed using a muscle-tendon unit model. Depending on whether data were normally distributed, a paired t-test or Wilcoxon signed rank test was performed to determine if body weight supported walking had any effects on joint kinematics and fascicle-series elastic element behavior. Walking with 30\% body weight support had no statistically significant effect on joint kinematics and peak series elastic element length. Furthermore, at the time when peak series elastic element length was achieved, and on average across the entire stance phase, muscle-tendon unit length, fascicle length, pennation angle, and fascicle velocity were unchanged with respect to body weight support. In accordance with unchanged gait kinematics, preservation of fascicle-series elastic element behavior was observed during walking with 30\% body weight support, which suggests transferability of gait patterns to subsequent unsupported walking.}, language = {en} }