@article{SavitskayaZhantlessovaKistaubayevaetal.2023, author = {Savitskaya, Irina and Zhantlessova, Sirina and Kistaubayeva, Aida and Ignatova, Ludmila and Shokatayeva, Dina and Sinyavsky, Yuriy and Kushugulova, Almagul and Digel, Ilya}, title = {Prebiotic cellulose-pullulan matrix as a "vehicle" for probiotic biofilm delivery to the host large intestine}, series = {Polymers}, journal = {Polymers}, number = {16(1)}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/polym16010030}, pages = {Artikel 30}, year = {2023}, abstract = {This study describes the development of a new combined polysaccharide-matrix-based technology for the immobilization of Lactobacillus rhamnosus GG (LGG) bacteria in biofilm form. The new composition allows for delivering the bacteria to the digestive tract in a manner that improves their robustness compared with planktonic cells and released biofilm cells. Granules consisting of a polysaccharide matrix with probiotic biofilms (PMPB) with high cell density (>9 log CFU/g) were obtained by immobilization in the optimized nutrient medium. Successful probiotic loading was confirmed by fluorescence microscopy and scanning electron microscopy. The developed prebiotic polysaccharide matrix significantly enhanced LGG viability under acidic (pH 2.0) and bile salt (0.3\%) stress conditions. Enzymatic extract of feces, mimicking colon fluid in terms of cellulase activity, was used to evaluate the intestinal release of probiotics. PMPB granules showed the ability to gradually release a large number of viable LGG cells in the model colon fluid. In vivo, the oral administration of PMPB granules in rats resulted in the successful release of probiotics in the colon environment. The biofilm-forming incubation method of immobilization on a complex polysaccharide matrix tested in this study has shown high efficacy and promising potential for the development of innovative biotechnologies.}, language = {en} } @article{KezerashviliDachwald2021, author = {Kezerashvili, Roman Ya and Dachwald, Bernd}, title = {Preface: Solar sailing: Concepts, technology, and missions II}, series = {Advances in Space Research}, volume = {67}, journal = {Advances in Space Research}, number = {9}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0273-1177}, doi = {10.1016/j.asr.2021.01.037}, pages = {2559 -- 2560}, year = {2021}, language = {en} } @article{RauschKahmannBaltschunetal.2020, author = {Rausch, Valentin and Kahmann, Stephanie Lucina and Baltschun, Christoph and Staat, Manfred and M{\"u}ller, Lars P. and Wegmann, Kilian}, title = {Pressure distribution to the distal biceps tendon at the radial tuberosity: a biomechanical study}, series = {The Journal of Hand Surgery}, volume = {45}, journal = {The Journal of Hand Surgery}, number = {8}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0363-5023}, doi = {10.1016/j.jhsa.2020.01.006}, pages = {776.e1 -- 776.e9}, year = {2020}, abstract = {Purpose Mechanical impingement at the narrow radioulnar space of the tuberosity is believed to be an etiological factor in the injury of the distal biceps tendon. The aim of the study was to compare the pressure distribution at the proximal radioulnar space between 2 fixation techniques and the intact state. Methods Six right arms and 6 left arms from 5 female and 6 male frozen specimens were used for this study. A pressure transducer was introduced at the height of the radial tuberosity with the intact distal biceps tendon and after 2 fixation methods: the suture-anchor and the cortical button technique. The force (N), maximum pressure (kPa) applied to the radial tuberosity, and the contact area (mm²) of the radial tuberosity with the ulna were measured and differences from the intact tendon were detected from 60° supination to 60° pronation in 15° increments with the elbow in full extension and in 45° and 90° flexion of the elbow. Results With the distal biceps tendon intact, the pressures during pronation were similar regardless of extension and flexion and were the highest at 60° pronation with 90° elbow flexion (23.3 ± 53.5 kPa). After repair of the tendon, the mean peak pressure, contact area, and total force showed an increase regardless of the fixation technique. Highest peak pressures were found using the cortical button technique at 45° flexion of the elbow and 60° pronation. These differences were significantly different from the intact tendon. The contact area was significantly larger in full extension and 15°, 30°, and 60° pronation using the cortical button technique. Conclusions Pressures on the distal biceps tendon at the radial tuberosity increase during pronation, especially after repair of the tendon. Clinical relevance Mechanical impingement could play a role in both the etiology of primary distal biceps tendon ruptures and the complications occurring after fixation of the tendon using certain techniques.}, language = {en} } @article{Digel2011, author = {Digel, Ilya}, title = {Primary thermosensory events in cells}, series = {Transient receptor potential channels / Md. Shahidul Islam, ed.}, journal = {Transient receptor potential channels / Md. Shahidul Islam, ed.}, publisher = {Springer}, address = {Dordrecht [u.a.]}, isbn = {978-94-007-0264-6}, pages = {451 -- 468}, year = {2011}, language = {en} } @article{Staat1996, author = {Staat, Manfred}, title = {Probabilistic assessment of the fracture mechanics behaviour of an HTR-module primary circuit pressure boundary}, series = {Nuclear Engineering and Design. 160 (1996), H. 1-2}, journal = {Nuclear Engineering and Design. 160 (1996), H. 1-2}, isbn = {0029-5493}, pages = {221 -- 236}, year = {1996}, language = {en} } @article{TranKreissigStaat2009, author = {Tran, Thanh Ngoc and Kreißig, R. and Staat, Manfred}, title = {Probabilistic limit and shakedown analysis of thin plates and shells}, series = {Structural safety. 31 (2009), H. 1}, journal = {Structural safety. 31 (2009), H. 1}, publisher = {-}, isbn = {0167-4730}, pages = {1 -- 18}, year = {2009}, language = {en} } @article{StaatHeitzer2003, author = {Staat, Manfred and Heitzer, M.}, title = {Probabilistic limit and shakedown problems}, series = {Numerical Methods for Limit and Shakedown Analysis. Deterministic and Probabilistic Approach. NIC Series Vol. 15 / Ed. by Staat, M; Heitzer, M.}, journal = {Numerical Methods for Limit and Shakedown Analysis. Deterministic and Probabilistic Approach. NIC Series Vol. 15 / Ed. by Staat, M; Heitzer, M.}, publisher = {John von Neumann Institute for Computing (NIC)}, address = {J{\"u}lich}, isbn = {3-00-010001-6}, pages = {217 -- 268}, year = {2003}, language = {en} } @article{Staat1992, author = {Staat, Manfred}, title = {Probabilistische Bewertung des bruchmechanischen Verhaltens der Prim{\"a}rkreisdruckumschließung eines HTR-Moduls}, year = {1992}, language = {de} } @article{Staat1996, author = {Staat, Manfred}, title = {Problems and Chances for Probabilistic Fracture Mechanics in the Analysis of Steel Pressure Boundary Reliability}, series = {Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in J{\"u}lich, 21-24 November 1994}, journal = {Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in J{\"u}lich, 21-24 November 1994}, address = {Vienna}, pages = {43 -- 55}, year = {1996}, language = {en} } @article{KoppSchmeetsGosauetal.2019, author = {Kopp, Alexander and Schmeets, Ralf and Gosau, Martin and Friedrich, Reinhard E. and Fuest, Sandra and Behbahani, Mehdi and Barbeck, Mike and Rutkowski, Rico and Burg, Simon and Kluwe, Lan and Henningsen, Anders}, title = {Production and Characterization of Porous Fibroin Scaffolds for Regenerative Medical Application}, series = {In Vivo}, volume = {33}, journal = {In Vivo}, number = {3}, issn = {1791-7549}, doi = {10.21873/invivo.11536}, pages = {757 -- 762}, year = {2019}, language = {en} } @article{JiminezGermanBehbahaniMiettinenetal.2013, author = {Jiminez German, Salvador and Behbahani, Mehdi and Miettinen, Susanna and Grijpma, Dirk W. and Haimi, Suvi P.}, title = {Proliferation and differentiation of adipose stem cells towards smooth muscle cells on poly(trimethylene carbonate) membranes}, series = {Macromolecular symposia}, volume = {Vol. 334}, journal = {Macromolecular symposia}, number = {Iss. 1}, publisher = {Wiley}, address = {Weinheim}, issn = {0258-0322}, pages = {133 -- 142}, year = {2013}, language = {en} } @article{BlomeSeboldtDachwaldetal.2004, author = {Blome, Hans-Joachim and Seboldt, Wolfgang and Dachwald, Bernd and Richter, Lutz}, title = {Proposal for an integrated European Space Exploration Study}, series = {Space Debris and Space Traffic Management Symposium 2004 : proceedings of the International Academy of Astronautics Space Debris and Space Traffic Management Symposium, held in conjunction with the 55th International Astronautical Congress (IAC), October 4 - 8, 2004, Vancouver, British Columbia, Canada / ed. by Joerg Bendisch}, journal = {Space Debris and Space Traffic Management Symposium 2004 : proceedings of the International Academy of Astronautics Space Debris and Space Traffic Management Symposium, held in conjunction with the 55th International Astronautical Congress (IAC), October 4 - 8, 2004, Vancouver, British Columbia, Canada / ed. by Joerg Bendisch}, publisher = {Univelt}, address = {San Diego, Calif.}, isbn = {0-87703-523-7}, pages = {XI, 432 S. : Ill., graph. Darst.}, year = {2004}, language = {en} } @article{DigelZerlinTemizArtmannetal.2007, author = {Digel, Ilya and Zerlin, Kay and Temiz Artmann, Ayseg{\"u}l and Engels, S.}, title = {Protein dynamics in thermosensation}, series = {Regenerative medicine. 2 (2007), H. 5}, journal = {Regenerative medicine. 2 (2007), H. 5}, isbn = {1746-0751}, pages = {533 -- 533}, year = {2007}, language = {en} } @article{HacklMuellerStaatetal.2016, author = {Hackl, Michael and M{\"u}ller, Lars-Peter and Staat, Manfred and Kahmann, Stephanie Lucina and Wegmann, Kilian}, title = {Proximal phalangeal neck fractures of the hand — a biomechanical comparison of three fixation techniques}, series = {Knee surgery, sports traumatology, arthroscopy}, volume = {Volume 24}, journal = {Knee surgery, sports traumatology, arthroscopy}, number = {Supplement 1}, publisher = {Springer}, address = {Berlin}, issn = {0942-2056}, doi = {10.1007/s00167-016-4080-7}, pages = {148 -- 149}, year = {2016}, abstract = {Plate osteosynthesis of displaced proximal phalangeal neck fractures of the hand allows early mobilization due to a stable internal fixation. Nevertheless, joint stiffness—because of soft tissue irritation—represents a common complication leading to high complication rates. Del Pinal et al. recently reported promising clinical results for a new, minimally invasive fixation technique with a cannulated headless intramedullary compression screw. Hence, the aim of this study was to compare plate fixation of proximal phalangeal neck fractures to less two less invasive techniques: Crossed k-wire fixation and intramedullary screw fixation. We hypothesized that these fixation techniques provide inferior stability when compared to plate osteosynthesis.}, language = {en} } @article{KotliarBaumannVilseretal.2011, author = {Kotliar, Konstantin and Baumann, Marcus and Vilser, Walthard and Lanzl, Ines M.}, title = {Pulse wave velocity in retinal arteries of healthy volunteers}, series = {British Journal of Ophthalmology (eBJO)}, volume = {95}, journal = {British Journal of Ophthalmology (eBJO)}, number = {11}, publisher = {BMJ Publ. Group}, address = {London}, isbn = {1468-2079}, pages = {675 -- 679}, year = {2011}, language = {en} } @article{HacklWegmannKahmannetal.2017, author = {Hackl, Michael and Wegmann, Kilian and Kahmann, Stephanie Lucina and Heinze, Nicolai and Staat, Manfred and Neiss, Wolfram F. and Scaal, Martin and M{\"u}ller, Lars P.}, title = {Radial shortening osteotomy reduces radiocapitellar contact pressures while preserving valgus stability of the elbow}, series = {Knee Surgery, Sports Traumatology, Arthroscopy}, volume = {25}, journal = {Knee Surgery, Sports Traumatology, Arthroscopy}, number = {7}, publisher = {Springer}, address = {Berlin}, issn = {1433-7347}, doi = {10.1007/s00167-017-4468-z}, pages = {2280 -- 2288}, year = {2017}, language = {en} } @article{WiescherKotliarNeuhannetal.2010, author = {Wiescher, A. and Kotliar, Konstantin and Neuhann, T. and Lanzl, Ines M.}, title = {Rasch progrediente Visusminderung beider Augen bei einem jungen Patienten}, series = {Der Ophthalmologe}, volume = {105}, journal = {Der Ophthalmologe}, number = {4}, publisher = {Springer}, address = {Berlin}, issn = {1433-0423}, doi = {10.1007/s00347-007-1586-x}, pages = {389 -- 392}, year = {2010}, abstract = {Ein 34-j{\"a}hriger m{\"a}nnlicher Patient stellte sich zur Abkl{\"a}rung einer seit dem 9. Lebensjahr bestehenden und im letzten Jahr rasch progredienten Visusminderung beider Augen bei uns vor. Er beschrieb eine subjektiv zunehmende, im Spiegel f{\"u}r ihn selbst sichtbare, weißliche Tr{\"u}bung in der Pupille beidseits und eine starke Blendempfindlichkeit. Nebenbefundlich gab er rezidivierende Konjunktivitiden und morgens verklebte Lider an. Eine Allergie auf Gr{\"a}serpollen und eine Unvertr{\"a}glichkeit auf Alkohol sowie mehrere Lebensmittel seien ebenfalls bekannt. Zus{\"a}tzlich leidet der Patient an stark ausgepr{\"a}gtem atopischem Ekzem. Dieses wurde nie systemisch, sondern nur bei Bedarf mit kortisonhaltiger Salbe therapiert.}, language = {de} } @article{KotliarLanzlWittaetal.2000, author = {Kotliar, Konstantin and Lanzl, Ines M. and Witta, Birka and Vilser, Walthard}, title = {Reaktion retinaler Gef{\"a}ßdurchmesser auf 100 \% O2-Atmung - funktionelle Messung mit dem Retinal Vessel Analyzer an 10 Probanden / Lanzl, Ines M. ; Witta, Birke ; Kotliar, Konstantin ; Vilser, Walthard}, series = {Klinische Monatsbl{\"a}tter f{\"u}r Augenheilkunde. 217 (2000), H. 4}, journal = {Klinische Monatsbl{\"a}tter f{\"u}r Augenheilkunde. 217 (2000), H. 4}, publisher = {-}, isbn = {1439-3999}, pages = {231 -- 235}, year = {2000}, language = {de} } @article{TemizArtmannKurulgandemirciFıratetal.2021, author = {Temiz Artmann, Ayseg{\"u}l and Kurulgan demirci, Eylem and F{\i}rat, Ipek Seda and Oflaz, Hakan and Artmann, Gerhard}, title = {Recombinant activated protein C (rhAPC) affects lipopolysaccharide-induced mechanical compliance changes and beat frequency of mESC-derived cardiomyocyte monolayers}, series = {SHOCK}, journal = {SHOCK}, publisher = {Wolters Kluwer}, address = {K{\"o}ln}, issn = {1540-0514}, doi = {10.1097/SHK.0000000000001845}, year = {2021}, language = {en} } @article{HacklLeschingerStaatetal.2016, author = {Hackl, Michael and Leschinger, T. and Staat, Manfred and M{\"u}ller, Lars-Peter and Wegmann, Kilian}, title = {Reconstruction of the interosseous membrane in the Essex Lopresti lesion — a biomechanical evaluation}, series = {Knee surgery, sports traumatology, arthroscopy}, volume = {Volume 24}, journal = {Knee surgery, sports traumatology, arthroscopy}, number = {Supplement 1}, publisher = {Springer}, address = {Berlin}, issn = {0942-2056}, doi = {10.1007/s00167-016-4080-7}, pages = {130 -- 131}, year = {2016}, abstract = {Surgical reconstruction of the interosseous membrane (IOM) could restore longitudinal forearm stability to avoid persisting disability due to capituloradial and ulnocarpal impingement in Essex Lopresti lesions. This biomechanical study aimed to assess longitudinal forearm stability of intact specimens, after sectioning of the IOM and after reconstruction with a TightRope construct using either a single or double bundle technique.}, language = {en} } @article{CapriMorsianiSantoroetal.2019, author = {Capri, Miriam and Morsiani, Cristina and Santoro, Aurelia and Moriggi, Manuela and Conte, Maria and Martucci, Morena and Bellavista, Elena and Fabbri, Cristina and Giampieri, Enrico and Albracht, Kirsten and Fl{\"u}ck, Martin and Ruoss, Severin and Brocca, Lorenza and Canepari, Monica and Longa, Emanuela and Giulio, Irene Di and Bottinelli, Roberto and Cerretelli, Paolo and Salvioli, Stefano and Gelfi, Cecilia and Franceschi, Claudio and Narici, Marco and Rittweger, J{\"o}rn}, title = {Recovery from 6-month spaceflight at the International Space Station: muscle-related stress into a proinflammatory setting}, series = {The FASEB journal : official publication of the Federation of American Societies for Experimental Biology}, volume = {33}, journal = {The FASEB journal : official publication of the Federation of American Societies for Experimental Biology}, number = {4}, doi = {10.1096/fj.201801625R}, pages = {5168 -- 5180}, year = {2019}, language = {en} } @article{StaeudleSeynnesLapsetal.2021, author = {St{\"a}udle, Benjamin and Seynnes, Olivier and Laps, Guido and G{\"o}ll, Fabian and Br{\"u}ggemann, Gert-Peter and Albracht, Kirsten}, title = {Recovery from achilles tendon repair: a combination of Postsurgery Outcomes and Insufficient remodeling of muscle and tendon}, series = {Medicine \& Science in Sports \& Exercise}, volume = {53}, journal = {Medicine \& Science in Sports \& Exercise}, number = {7}, publisher = {American College of Sports Medicine}, address = {Philadelphia, Pa.}, issn = {1530-0315}, doi = {10.1249/MSS.0000000000002592}, pages = {1356 -- 1366}, year = {2021}, abstract = {Achilles tendon rupture (ATR) patients have persistent functional deficits in the triceps surae muscle-tendon unit (MTU). The complex remodeling of the MTU accompanying these deficits remains poorly understood. The purpose of the present study was to associate in vivo and in silico data to investigate the relations between changes inMTU properties and strength deficits inATR patients. Methods: Elevenmale subjects who had undergone surgical repair of complete unilateral ATR were examined 4.6 ± 2.0 (mean ± SD) yr after rupture. Gastrocnemius medialis (GM) tendon stiffness, morphology, and muscle architecture were determined using ultrasonography. The force-length relation of the plantar flexor muscles was assessed at five ankle joint angles. In addition, simulations (OpenSim) of the GM MTU force-length properties were performed with various iterations of MTU properties found between the unaffected and the affected side. Results: The affected side of the patients displayed a longer, larger, and stiffer GM tendon (13\% ± 10\%, 105\% ± 28\%, and 54\% ± 24\%, respectively) compared with the unaffected side. The GM muscle fascicles of the affected side were shorter (32\% ± 12\%) and with greater pennation angles (31\% ± 26\%). A mean deficit in plantarflexion moment of 31\% ± 10\% was measured. Simulations indicate that pairing an intact muscle with a longer tendon shifts the optimal angular range of peak force outside physiological angular ranges, whereas the shorter muscle fascicles and tendon stiffening seen in the affected side decrease this shift, albeit incompletely. Conclusions: These results suggest that the substantial changes in MTU properties found in ATR patients may partly result from compensatory remodeling, although this process appears insufficient to fully restore muscle function.}, language = {en} } @article{TemizArtmannBaskurtMeiselman1997, author = {Temiz Artmann, Ayseg{\"u}l and Baskurt, O. K. and Meiselman, H. J.}, title = {Red blood cell aggregation in experimental sepsis . Baskurt, O. K.; Temiz, A.; Meiselman, H. J.}, series = {Journal of Laboratory and Clinical Medicine. 130 (1997), H. 2}, journal = {Journal of Laboratory and Clinical Medicine. 130 (1997), H. 2}, isbn = {0022-2143}, pages = {183 -- 190}, year = {1997}, language = {en} } @article{DachwaldMengaliQuartaetal.2007, author = {Dachwald, Bernd and Mengali, Giovanni and Quarta, Alessandro A. and Circi, Christian}, title = {Refined Solar Sail Force Model with Mission Application / Giovanni Mengali ; Alessandro A. Quarta , Christian Circi ; Bernd Dachwald}, series = {Journal of Guidance, Control, and Dynamics. 30 (2007), H. 2}, journal = {Journal of Guidance, Control, and Dynamics. 30 (2007), H. 2}, isbn = {0162-3192}, pages = {512 -- 520}, year = {2007}, language = {en} } @article{SponagelBecker1984, author = {Sponagel, Stefan and Becker, E.}, title = {Reibungsfreie, ebene Diffusorstr{\"o}mung mit beliebigem Einlaufprofil. E. Becker, S. Sponagel}, series = {Zeitschrift f{\"u}r angewandte Mathematik und Mechanik: ZAMM. 64 (1984)}, journal = {Zeitschrift f{\"u}r angewandte Mathematik und Mechanik: ZAMM. 64 (1984)}, isbn = {0044-2267}, pages = {T174 -- T177}, year = {1984}, language = {de} } @article{StaatHeitzer2000, author = {Staat, Manfred and Heitzer, M.}, title = {Reliability Analysis of Elasto-Plastic Structures under Variable Loads}, series = {Inelastic analysis of structures under variable loads : theory and engineering applications / Maier, G.; Weichert, D. [ed]}, journal = {Inelastic analysis of structures under variable loads : theory and engineering applications / Maier, G.; Weichert, D. [ed]}, publisher = {Kluwer Academic Publ.}, address = {Dordrecht}, isbn = {0-7923-6645-X}, pages = {269 -- 288}, year = {2000}, language = {en} } @article{TranPhamVuetal.2009, author = {Tran, Thanh Ngoc and Pham, Phu Tinh and Vu, D. K. and Staat, Manfred}, title = {Reliability Analysis of Inelastic Shell Structures Under Variable Loads}, series = {Limit States of Materials and Structures : Direct Methods / Hrsg. Dieter Weichert; Hrsg. Alan Ponter}, journal = {Limit States of Materials and Structures : Direct Methods / Hrsg. Dieter Weichert; Hrsg. Alan Ponter}, publisher = {Springer Netherland}, address = {Berlin}, isbn = {978-1-4020-9633-4}, pages = {135 -- 156}, year = {2009}, language = {en} } @article{StaatFioriniLensaetal.1997, author = {Staat, Manfred and Fiorini, G. L. and Lensa, W. von and Burgazzi, L.}, title = {Reliability Methods for Passive Safety Functions}, series = {Proceedings of the SMiRT 14 Post Conference Seminar No 18 on Passive Safety Features in Nuclear Installations}, journal = {Proceedings of the SMiRT 14 Post Conference Seminar No 18 on Passive Safety Features in Nuclear Installations}, address = {Pisa}, year = {1997}, language = {en} } @article{Staat1995, author = {Staat, Manfred}, title = {Reliability of an HTR-module primary circuit pressure boundary Influences, sensitivity, and comparison with a PWR}, series = {Nuclear Engineering and Design. 158 (1995), H. 2-3}, journal = {Nuclear Engineering and Design. 158 (1995), H. 2-3}, isbn = {0029-5493}, pages = {333 -- 340}, year = {1995}, language = {en} } @article{QuittmannAbelAlbrachtetal.2019, author = {Quittmann, Oliver J. and Abel, Thomas and Albracht, Kirsten and Str{\"u}der, Heiko K.}, title = {Reliability of muscular activation patterns and their alterations during incremental handcycling in able-bodied participants}, series = {Sports Biomechanics}, journal = {Sports Biomechanics}, number = {Article in press}, publisher = {Taylor \& Francis}, address = {London}, issn = {1752-6116}, doi = {10.1080/14763141.2019.1593496}, year = {2019}, language = {en} } @article{Staat1993, author = {Staat, Manfred}, title = {Reliability of the Primary Circuit Pressure Boundary of an HTR-Module under Accident Conditions}, series = {Safety and reliability assessment : an integral approach ; ESREL'93 ; proceedings of the European Safety and Reliability Conference, Munich, Germany, May 10th - 12th 1993 / Kafka, P. [ed]}, journal = {Safety and reliability assessment : an integral approach ; ESREL'93 ; proceedings of the European Safety and Reliability Conference, Munich, Germany, May 10th - 12th 1993 / Kafka, P. [ed]}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {0-444-81561-9}, pages = {331 -- 342}, year = {1993}, language = {en} } @article{AggeloussisGiannakouAlbrachtetal.2010, author = {Aggeloussis, Nickos and Giannakou, Erasmia and Albracht, Kirsten and Arampatzis, Adamantios}, title = {Reproducibility of fascicle length and pennation angle of gastrocnemius medialis in human gait in vivo}, series = {Gait and Posture}, volume = {31}, journal = {Gait and Posture}, number = {1}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0966-6362}, doi = {10.1016/j.gaitpost.2009.08.249}, pages = {73 -- 77}, year = {2010}, abstract = {The purpose of the current study was to examine the reproducibility of fascicle length and pennation angle of gastrocnemius medialis while human walking. To the best of our knowledge, this is the first study of the reproducibility of fascicle length and pennation angle of gastrocnemius medialis in vivo during human gait. Twelve males performed 10 gait trials on a treadmill, in 2 separate days. B-mode ultrasonography, with the ultrasound probe firmly adjusted in the transverse and frontal planes using a special cast, was used to measure the fascicle length and the pennation angle of the gastrocnemius medialis (GM). A Vicon 624 system with three cameras operating at 120 Hz was also used to record the ankle and knee joint angles. The results showed that measurements of fascicle length and pennation angle showed high reproducibility during the gait cycle, both within the same day and between different days. Moreover, the root mean square differences between the repeated waveforms of both variables were very small, compared with their ranges (fascicle length: RMS = ∼3 mm, range: 38-63 mm; pennation angle: RMS = ∼1.5°, range: 22-32°). However, their reproducibility was lower compared to the joint angles. It was found that representative data have to be derived by a wide number of gait trials (fascicle length ∼six trials, pennation angle more than 10 trials), to assure the reliability of the fascicle length and pennation angle in human gait.}, language = {en} } @article{DigelTrzewikDemircietal.2004, author = {Digel, Ilya and Trzewik, J{\"u}rgen and Demirci, Taylan and Temiz Artmann, Ayseg{\"u}l}, title = {Response of fibroblasts to cyclic mechanical stress : a proteome approach / Digel, I. ; Trzewik, J. ; Demirci, T. ; Temiz Artmann, A. ; Artmann, G. M.}, series = {Biomedizinische Technik. 49 (2004), H. Erg.-Bd. 2}, journal = {Biomedizinische Technik. 49 (2004), H. Erg.-Bd. 2}, isbn = {0932-4666}, pages = {1042 -- 1043}, year = {2004}, language = {en} } @article{ArtmannGrebeHomrighausenetal.1988, author = {Artmann, Gerhard and Grebe, R. and Homrighausen, A. and Wolff, H. and [u.a.],}, title = {Response of normal and diabetic erythrocytes to membrane deformation by chemical and mechanical forces. Artmann, Gerhard Michael; Grebe, R.; Homrighausen, A.; Wolff, H.; Teitel, P.; Schmid-Sch{\"o}nbein, H.}, series = {12. Jahrestagung der Gesellschaft f{\"u}r Mikrozirkulation}, journal = {12. Jahrestagung der Gesellschaft f{\"u}r Mikrozirkulation}, publisher = {Karger [u.a.]}, address = {Basel [u.a.]}, pages = {196 -- 200}, year = {1988}, language = {en} } @article{ArtmannSchmidSchoenbeinGrebeetal.1988, author = {Artmann, Gerhard and Schmid-Sch{\"o}nbein, H. and Grebe, R. and Teitel, P. [u.a.]}, title = {Restoration of Microsieve Filterability of Human Red Cells After Exposure to Hyperosmolarity and Lactazidosis: Effect of Vinpocetine. Schmid-Sch{\"o}nbein, H.; Grebe, R.; Teitel, P.; Artmann, Gerhard Michael, Eschweiler, H.; Schr{\"o}der, Susanne}, series = {Drug Development Research. 14 (1988), H. 3-4}, journal = {Drug Development Research. 14 (1988), H. 3-4}, isbn = {1098-2299}, pages = {205 -- 211}, year = {1988}, language = {en} } @article{StreeseKotliarDeiserothetal.2020, author = {Streese, Lukas and Kotliar, Konstantin and Deiseroth, Arne and Infanger, Denis and Gugleta, Konstantin and Schmaderer, Christoph and Hanssen, Henner}, title = {Retinal endothelial function in cardiovascular risk patients: A randomized controlled exercise trial}, series = {Scandinavian Journal of Medicine and Science in Sports}, volume = {30}, journal = {Scandinavian Journal of Medicine and Science in Sports}, number = {2}, publisher = {Wiley}, address = {Oxford}, issn = {1600-0838}, doi = {10.1111/sms.13560}, pages = {272 -- 280}, year = {2020}, abstract = {The aim of this study was to investigate, for the first time, the effects of high-intensity interval training (HIIT) on retinal microvascular endothelial function in cardiovascular (CV) risk patients. In the randomized controlled trial, middle-aged and previously sedentary patients with increased CV risk (aged 58 ± 6 years) with ≥ two CV risk factors were randomized into a 12-week HIIT (n = 33) or control group (CG, n = 36) with standard physical activity recommendations. A blinded examiner measured retinal endothelial function by flicker light-induced maximal arteriolar (ADmax) and venular (VDmax) dilatation as well as the area under the arteriolar (AFarea) and venular (VFarea) flicker curve using a retinal vessel analyzer. Standardized assessments of CV risk factors, cardiorespiratory fitness, and retinal endothelial function were performed before and after HIIT. HIIT reduced body mass index, fat mass, and low-density lipoprotein and increased muscle mass and peak oxygen uptake (VO2peak). Both ADmax (pre: 2.7 ± 2.1\%, post: 3.0 ± 2.2\%, P = .018) and AFarea (pre: 32.6 ± 28.4\%*s, post: 37.7 ± 30.6\%*s, P = .016) increased after HIIT compared with CG (ADmax, pre: 3.2 ± 1.8\%, post: 2.9 ± 1.8\%, P = .254; AFarea, pre: 41.6 ± 28.5\%*s, post: 37.8 ± 27.0\%*s, P = .186). Venular function remained unchanged after HIIT. There was a significant association between ∆-change VO2peak and ∆-changes ADmax and AFarea (P = .026, R² = 0.073; P = .019, R² = 0.081, respectively). 12-weeks of HIIT improved retinal endothelial function in middle-aged patients with increased CV risk independent of the reduction in classical CV risk factors. Exercise has the potential to reverse or at least postpone progression of small vessel disease in older adults with increased CV risk under standard medication. Dynamic retinal vessel analysis seems to be a sensitive tool to detect treatment effects of exercise interventions on retinal microvascular endothelial function in middle-aged individuals with increased CV risk.}, language = {en} } @article{RamoshabaHuismanLammertynetal.2020, author = {Ramoshaba, Nthai E. and Huisman, Hugo W. and Lammertyn, Leandi and Kotliar, Konstantin and Schutte, Aletta E. and Smith, Wayne}, title = {Retinal microvasculature and masked hypertension in young adults: the African-PREDICT study}, series = {Hypertension Research}, journal = {Hypertension Research}, number = {43}, publisher = {Springer Nature}, address = {Osaka}, issn = {1348-4214}, doi = {10.1038/s41440-020-0487-0}, pages = {1231 -- 1238}, year = {2020}, abstract = {Masked hypertension is known to induce microvascular complications. However, it is unclear whether early microvascular changes are already occurring in young, otherwise healthy adults. We therefore investigated whether retinal microvascular calibers and acute responses to a flicker stimulus are related to masked hypertension. We used the baseline data of 889 participants aged 20-30 years who were taking part in the African Prospective study on the Early Detection and Identification of Cardiovascular Disease and Hypertension. Clinic and 24-h ambulatory blood pressure were measured. The central retinal artery equivalent (CRAE) and central retinal vein equivalent were calculated from fundus images, and retinal vessel dilation was determined in response to flicker light-induced provocation. A smaller CRAE was observed in those with masked hypertension vs. those with normotension (157.1 vs. 161.2 measuring units, P < 0.001). In forward multivariable-adjusted regression analysis, only CRAE was negatively related to masked hypertension [adjusted R² = 0.267, β = -0.097 (95\% CI = -0.165; -0.029), P = 0.005], but other retinal microvascular parameters were not associated with masked hypertension. In multivariable logistic regression analyses, masked hypertension [OR = 2.333, (95\% CI = 1.316; 4.241), P = 0.004] was associated with a narrower CRAE. In young healthy adults, masked hypertension was associated with retinal arteriolar narrowing, thereby reflecting early microvascular alterations known to predict cardiovascular outcomes in later life.}, language = {en} } @article{KotliarHanssenEberhardtetal.2013, author = {Kotliar, Konstantin and Hanssen, Henner and Eberhardt, Karla and Vilser, Walthard and Schmaderer, Christoph and Halle, Martin and Heemann, Uwe and Baumann, M.}, title = {Retinal pulse wave velocity in young male normotensive and mildly hypertensive subjects}, series = {Microcirculation}, journal = {Microcirculation}, publisher = {Wiley}, address = {Malden}, issn = {1549-8719}, year = {2013}, language = {en} } @article{AlbannaConzenWeissetal.2016, author = {Albanna, W. and Conzen, C. and Weiss, M. and Clusmann, H. and Fuest, M. and Mueller, M. and Brockmann, M.A. and Vilser, W. and Schmidt-Trucks{\"a}ss, A. and Hoellig, A. and Seiz, M. and Thom{\´e}, C. and Kotliar, Konstantin and Schubert, G.A.}, title = {Retinal Vessel Analysis (RVA) in the context of subarachnoid hemorrhage: A proof of concept study}, series = {PLoS ONE}, volume = {11}, journal = {PLoS ONE}, number = {7}, publisher = {PLOS}, address = {San Francisco}, issn = {1932-6203}, doi = {10.1371/journal.pone.0158781}, pages = {13 Seiten}, year = {2016}, abstract = {Background Timely detection of impending delayed cerebral ischemia after subarachnoid hemorrhage (SAH) is essential to improve outcome, but poses a diagnostic challenge. Retinal vessels as an embryological part of the intracranial vasculature are easily accessible for analysis and may hold the key to a new and non-invasive monitoring technique. This investigation aims to determine the feasibility of standardized retinal vessel analysis (RVA) in the context of SAH. Methods In a prospective pilot study, we performed RVA in six patients awake and cooperative with SAH in the acute phase (day 2-14) and eight patients at the time of follow-up (mean 4.6±1.7months after SAH), and included 33 age-matched healthy controls. Data was acquired using a manoeuvrable Dynamic Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and neurovascular coupling. Results Image quality was satisfactory in the majority of cases (93.3\%). In the acute phase after SAH, retinal arteries were significantly dilated when compared to the control group (124.2±4.3MU vs 110.9±11.4MU, p<0.01), a difference that persisted to a lesser extent in the later stage of the disease (122.7±17.2MU, p<0.05). Testing for neurovascular coupling showed a trend towards impaired primary vasodilation and secondary vasoconstriction (p = 0.08, p = 0.09 resp.) initially and partial recovery at the time of follow-up, indicating a relative improvement in a time-dependent fashion. Conclusion RVA is technically feasible in patients with SAH and can detect fluctuations in vessel diameter and autoregulation even in less severely affected patients. Preliminary data suggests potential for RVA as a new and non-invasive tool for advanced SAH monitoring, but clinical relevance and prognostic value will have to be determined in a larger cohort.}, language = {en} } @article{SmithKotliarLammertynetal.2020, author = {Smith, Wayne and Kotliar, Konstantin and Lammertyn, Leandi and Ramoshaba, Nthai E. and Vilser, Walthard and Huisman, Hugo W. and Schutte, Aletta E.}, title = {Retinal vessel caliber and caliber responses in true normotensive black and white adults: The African-PREDICT study}, series = {Microvascular Research}, volume = {128}, journal = {Microvascular Research}, number = {Article 103937}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0026-2862}, doi = {10.1016/j.mvr.2019.103937}, year = {2020}, abstract = {Purpose Globally, a detrimental shift in cardiovascular disease risk factors and a higher mortality level are reported in some black populations. The retinal microvasculature provides early insight into the pathogenesis of systemic vascular diseases, but it is unclear whether retinal vessel calibers and acute retinal vessel functional responses differ between young healthy black and white adults. Methods We included 112 black and 143 white healthy normotensive adults (20-30 years). Retinal vessel calibers (central retinal artery and vein equivalent (CRAE and CRVE)) were calculated from retinal images and vessel caliber responses to flicker light induced provocation (FLIP) were determined. Additionally, ambulatory blood pressure (BP), anthropometry and blood samples were collected. Results The groups displayed similar 24 h BP profiles and anthropometry (all p > .24). Black participants demonstrated a smaller CRAE (158 ± 11 vs. 164 ± 11 MU, p < .001) compared to the white group, whereas CRVE was similar (p = .57). In response to FLIP, artery maximal dilation was greater in the black vs. white group (5.6 ± 2.1 vs. 3.3 ± 1.8\%; p < .001). Conclusions Already at a young age, healthy black adults showed narrower retinal arteries relative to the white population. Follow-up studies are underway to show if this will be related to increased risk for hypertension development. The reason for the larger vessel dilation responses to FLIP in the black population is unclear and warrants further investigation.}, language = {en} } @article{KotliarVilserNageletal.2004, author = {Kotliar, Konstantin and Vilser, Walthatd and Nagel, Edgar and Lanzl, Ines M.}, title = {Retinal vessel reaction in response to chromatic flickering light / Kotliar, Konstantin E. ; Vilser, Walthard ; Nagel, Edgar ; Lanzl, Ines M.}, series = {Graefe's Archive for Clinical and Experimental Ophthalmology. 242 (2004), H. 5}, journal = {Graefe's Archive for Clinical and Experimental Ophthalmology. 242 (2004), H. 5}, publisher = {-}, isbn = {1435-702X}, pages = {377 -- 392}, year = {2004}, language = {en} } @article{NeumaierKotliarHaerenetal.2021, author = {Neumaier, Felix and Kotliar, Konstantin and Haeren, Roel Hubert Louis and Temel, Yasin and L{\"u}ke, Jan Niklas and Seyam, Osama and Lindauer, Ute and Clusmann, Hans and Hescheler, J{\"u}rgen and Schubert, Gerrit Alexander and Schneider, Toni and Albanna, Walid}, title = {Retinal Vessel Responses to Flicker Stimulation Are Impaired in Ca v 2.3-Deficient Mice—An in- vivo Evaluation Using Retinal Vessel Analysis (RVA)}, series = {Frontiers in Neurology}, volume = {12}, journal = {Frontiers in Neurology}, publisher = {Frontiers}, doi = {10.3389/fneur.2021.659890}, pages = {1 -- 11}, year = {2021}, language = {en} } @article{MenzelKotliarLanzl2009, author = {Menzel, C. and Kotliar, Konstantin and Lanzl, I.}, title = {Retrospektive Untersuchung jahreszeitlich bedingter Einflussfaktoren auf den Augeninnendruck therapierter Glaukompatienten}, series = {Der Ophthalmologe}, volume = {106}, journal = {Der Ophthalmologe}, number = {11}, publisher = {-}, isbn = {1433-0423}, pages = {1006 -- 1011}, year = {2009}, language = {de} } @article{KurulganDemirciDemirciLinderetal.2012, author = {Kurulgan Demirci, Eylem and Demirci, Taylan and Linder, Peter and Trzewik, J{\"u}rgen and Gierkowski, Jessica Ricarda and Gossmann, Matthias and Kayser, Peter and Porst, Dariusz and Digel, Ilya and Artmann, Gerhard and Temiz Artmann, Ayseg{\"u}l}, title = {rhAPC reduces the endothelial cell permeability via a decrease of contractile tensions induced by endothelial cells}, series = {Journal of Bioscience and Bioengineering}, volume = {113}, journal = {Journal of Bioscience and Bioengineering}, number = {2}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1347-4421}, doi = {10.1016/j.jbiosc.2012.03.019}, pages = {212 -- 219}, year = {2012}, abstract = {All cells generate contractile tension. This strain is crucial for mechanically controlling the cell shape, function and survival. In this study, the CellDrum technology quantifying cell's (the cellular) mechanical tension on a pico-scale was used to investigate the effect of lipopolysaccharide (LPS) on human aortic endothelial cell (HAoEC) tension. The LPS effect during gram-negative sepsis on endothelial cells is cell contraction causing endothelium permeability increase. The aim was to finding out whether recombinant activated protein C (rhAPC) would reverse the endothelial cell response in an in-vitro sepsis model. In this study, the established in-vitro sepsis model was confirmed by interleukin 6 (IL-6) levels at the proteomic and genomic levels by ELISA, real time-PCR and reactive oxygen species (ROS) activation by florescence staining. The thrombin cellular contraction effect on endothelial cells was used as a positive control when the CellDrum technology was applied. Additionally, the Ras homolog gene family, member A (RhoA) mRNA expression level was checked by real time-PCR to support contractile tension results. According to contractile tension results, the mechanical predominance of actin stress fibers was a reason of the increased endothelial contractile tension leading to enhanced endothelium contractility and thus permeability enhancement. The originality of this data supports firstly the basic measurement principles of the CellDrum technology and secondly that rhAPC has a beneficial effect on sepsis influenced cellular tension. The technology presented here is promising for future high-throughput cellular tension analysis that will help identify pathological contractile tension responses of cells and prove further cell in-vitro models.}, language = {en} } @article{KolditzAlbinBrueggemannetal.2016, author = {Kolditz, Melanie and Albin, Thivaharan and Br{\"u}ggemann, Gert-Peter and Abel, Dirk and Albracht, Kirsten}, title = {Robotergest{\"u}tztes System f{\"u}r ein verbessertes neuromuskul{\"a}res Aufbautraining der Beinstrecker}, series = {at - Automatisierungstechnik}, volume = {64}, journal = {at - Automatisierungstechnik}, number = {11}, publisher = {De Gruyter}, address = {Berlin}, issn = {2196-677X}, doi = {10.1515/auto-2016-0044}, pages = {905 -- 914}, year = {2016}, abstract = {Neuromuskul{\"a}res Aufbautraining der Beinstrecker ist ein wichtiger Bestandteil in der Rehabilitation und Pr{\"a}vention von Muskel-Skelett-Erkrankungen. Effektives Training erfordert hohe Muskelkr{\"a}fte, die gleichzeitig hohe Belastungen von bereits gesch{\"a}digten Strukturen bedeuten. Um trainingsinduzierte Sch{\"a}digungen zu vermeiden, m{\"u}ssen diese Kr{\"a}fte kontrolliert werden. Mit heutigen Trainingsger{\"a}ten k{\"o}nnen diese Ziele allerdings nicht erreicht werden. F{\"u}r ein sicheres und effektives Training sollen durch den Einsatz der Robotik, Sensorik, eines Regelkreises sowie Muskel-Skelett-Modellen Belastungen am Zielgewebe direkt berechnet und kontrolliert werden. Auf Basis zweier Vorstudien zu m{\"o}glichen Stellgr{\"o}ßen wird der Aufbau eines robotischen Systems vorgestellt, das sowohl f{\"u}r Forschungszwecke als auch zur Entwicklung neuartiger Trainingsger{\"a}te verwendet werden kann.}, language = {de} } @article{FrankBuchwaldPennekampetal.2009, author = {Frank, T. and Buchwald, D. and Pennekamp, W. and Reber, D. and Sponagel, Stefan and Laszkovics, A. and Weber, Hans-Joachim}, title = {R{\"o}ntgenologische Untersuchung der Str{\"o}mungseigenschaften funktioneller Komponenten der Herz-Lungen-Maschine}, series = {Kardiotechnik. 18 (2009), H. 2}, journal = {Kardiotechnik. 18 (2009), H. 2}, isbn = {0941-2670}, pages = {31 -- 35}, year = {2009}, language = {de} } @article{FrotscherMuanghongDursunetal.2016, author = {Frotscher, Ralf and Muanghong, Danita and Dursun, G{\"o}zde and Goßmann, Matthias and Temiz Artmann, Ayseg{\"u}l and Staat, Manfred}, title = {Sample-specific adaption of an improved electro-mechanical model of in vitro cardiac tissue}, series = {Journal of Biomechanics}, volume = {49}, journal = {Journal of Biomechanics}, number = {12}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0021-9290 (Print)}, doi = {10.1016/j.jbiomech.2016.01.039}, pages = {2428 -- 2435}, year = {2016}, abstract = {We present an electromechanically coupled computational model for the investigation of a thin cardiac tissue construct consisting of human-induced pluripotent stem cell-derived atrial, ventricular and sinoatrial cardiomyocytes. The mechanical and electrophysiological parts of the finite element model, as well as their coupling are explained in detail. The model is implemented in the open source finite element code Code_Aster and is employed for the simulation of a thin circular membrane deflected by a monolayer of autonomously beating, circular, thin cardiac tissue. Two cardio-active drugs, S-Bay K8644 and veratridine, are applied in experiments and simulations and are investigated with respect to their chronotropic effects on the tissue. These results demonstrate the potential of coupled micro- and macroscopic electromechanical models of cardiac tissue to be adapted to experimental results at the cellular level. Further model improvements are discussed taking into account experimentally measurable quantities that can easily be extracted from the obtained experimental results. The goal is to estimate the potential to adapt the presented model to sample specific cell cultures.}, language = {en} } @article{RittwegerAlbrachtFluecketal.2018, author = {Rittweger, J{\"o}rn and Albracht, Kirsten and Fl{\"u}ck, Martin and Ruoss, Severin and Brocca, Lorenza and Longa, Emanuela and Moriggi, Manuela and Seynnes, Olivier and Di Giulio, Irene and Tenori, Leonardo and Vignoli, Alessia and Capri, Miriam and Gelfi, Cecilia and Luchinat, Claudio and Franceschi, Claudio and Bottinelli, Roberto and Cerretelli, Paolo and Narici, Marco}, title = {Sarcolab pilot study into skeletal muscle's adaptation to longterm spaceflight}, series = {npj Microgravity}, volume = {4}, journal = {npj Microgravity}, number = {1}, publisher = {Nature Portfolio}, issn = {2373-8065}, doi = {10.1038/s41526-018-0052-1}, pages = {1 -- 9}, year = {2018}, language = {en} } @article{SponagelKilthauSpies1987, author = {Sponagel, Stefan and Kilthau, G. and Spies, K. H.}, title = {Sealing mechanism of lip seals}, series = {Eleventh 11th International Conference on Fluid Sealing : proceedings of the 11th Internat. Conference on Fluid Sealing, held at Cannes, France 8 - 10 April, 1987 / organised and sponsored by BHRA, the Fluid Engineering Centre. Ed. B. S. Nau}, journal = {Eleventh 11th International Conference on Fluid Sealing : proceedings of the 11th Internat. Conference on Fluid Sealing, held at Cannes, France 8 - 10 April, 1987 / organised and sponsored by BHRA, the Fluid Engineering Centre. Ed. B. S. Nau}, publisher = {Elsevier}, address = {London}, isbn = {3-540-51383-3}, pages = {748 -- 772}, year = {1987}, language = {en} } @article{Staat1993, author = {Staat, Manfred}, title = {Sensitivity of and Influences on the Reliability of an HTR-Module Primary Circuit Pressure Boundary}, series = {Transactions of the 12th International Conference on Structural Mechanics in Reactor Technology (SMiRT-12) / Kussmaul, K. [ed]}, journal = {Transactions of the 12th International Conference on Structural Mechanics in Reactor Technology (SMiRT-12) / Kussmaul, K. [ed]}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {0-444-81515-5}, pages = {147 -- 152}, year = {1993}, language = {en} }