@article{LeversStaatLaack2016, author = {Levers, A. and Staat, Manfred and Laack, Walter van}, title = {Analysis of the long-term effect of the MBST® nuclear magnetic resonance therapy on gonarthrosis}, series = {Orthopedic Practice}, volume = {47}, journal = {Orthopedic Practice}, number = {11}, pages = {521 -- 528}, year = {2016}, language = {en} } @article{Sponagel1987, author = {Sponagel, Stefan}, title = {Analytische Berechnung von Gummi- Metall- Verbindungen}, series = {Konstruktion : Zeitschrift f{\"u}r Produktentwicklung. 39 (1987), H. 4}, journal = {Konstruktion : Zeitschrift f{\"u}r Produktentwicklung. 39 (1987), H. 4}, isbn = {0373-3300}, pages = {151 -- 158}, year = {1987}, language = {de} } @article{StaatBallmann1985, author = {Staat, Manfred and Ballmann, J.}, title = {Anisotrope Ausbreitung und Fokussierung von Beschleunigungswellen in vorgespannten nichtlinearelastischen Scheiben}, series = {Wellenfokussierung, Kolloquium des SFB 27, RWTH Aachen}, journal = {Wellenfokussierung, Kolloquium des SFB 27, RWTH Aachen}, address = {Aachen}, pages = {140 -- 158}, year = {1985}, language = {de} } @article{Staat1987, author = {Staat, Manfred}, title = {Anisotrope Wellenausbreitung in isotropen hyperelastischen Scheiben}, series = {Zeitschrift f{\"u}r angewandte Mathematik und Mechanik : ZAMM. 67 (1987), H. 4}, journal = {Zeitschrift f{\"u}r angewandte Mathematik und Mechanik : ZAMM. 67 (1987), H. 4}, isbn = {0946-8463}, pages = {T241 -- T243}, year = {1987}, language = {de} } @article{SavitskayaKistaubayevaIgnatovaetal.2019, author = {Savitskaya, I.S. and Kistaubayeva, A.S. and Ignatova, L.V. and Digel, Ilya}, title = {Antimicrobial and wound healing properties of a bacterial cellulose based material containing B. subtilis cells}, series = {Heliyon}, volume = {5}, journal = {Heliyon}, number = {10}, publisher = {Elsevier}, address = {Amsterdam}, issn = {2405-8440}, doi = {10.1016/j.heliyon.2019.e02592}, pages = {Artikelnummer e02592}, year = {2019}, language = {en} } @article{MurganBeyerKotliaretal.2013, author = {Murgan, Ilina and Beyer, Sonja and Kotliar, Konstantin and Weber, Lutz and Bechtold-Dalla Pozza, Susanne and Dalla Pozza, Robert and Wegner, Aharon and Sitnikova, Diana and Stock, Konrad and Heemann, Uwe and Schmaderer, Christoph and Baumann, M.}, title = {Arterial and Retinal Vascular Changes in Hypertensive and Prehypertensive Adolescents}, series = {American Journal of Hypertension}, volume = {26}, journal = {American Journal of Hypertension}, number = {3}, publisher = {Oxford University Press}, address = {Oxford}, issn = {1941-7225}, pages = {400 -- 408}, year = {2013}, language = {de} } @article{ErmolaevErichevAntonovetal.2019, author = {Ermolaev, AP and Erichev, VP and Antonov, AA and Grigoryan, GL and Kotliar, Konstantin and Levitsky, YV and Hderi, K and Mazurova, YV}, title = {Assessing retinal photosensitivity in patients with central vision impairment using a portable perimeter (a preliminary report)}, series = {Vestnik oftalmologii}, volume = {135}, journal = {Vestnik oftalmologii}, number = {3}, doi = {10.17116/oftalma201913503146}, pages = {46 -- 54}, year = {2019}, language = {ru} } @article{BogoyavlenskiyDigelBerezin1997, author = {Bogoyavlenskiy, A. P. and Digel, Ilya and Berezin, V. E.}, title = {Assessment of dot-blot ELISA sensitivity on membrane sorbent using various peroxidase substrates}, year = {1997}, abstract = {The sensitivity of the peroxidase reaction in dot-blot ELISA significantly depends on the substrate. The highest sensitivity is observed using benzidine and diamine- phenol combinations as the substrates due to the reaction of the coupled oxidation (NADI)}, subject = {Enzyme-linked immunosorbent assay}, language = {en} } @article{AlbrachtArampatzisBaltzopoulos2008, author = {Albracht, Kirsten and Arampatzis, A. and Baltzopoulos, V.}, title = {Assessment of muscle volume and physiological cross-sectional area of the human triceps surae muscle in vivo}, series = {Journal of Biomechanics}, volume = {41}, journal = {Journal of Biomechanics}, issn = {0021-9290}, doi = {10.1016/j.jbiomech.2008.04.020}, pages = {2211 -- 2218}, year = {2008}, language = {en} } @article{BehbahaniSpillnerKoppetal.2009, author = {Behbahani, Mehdi and Spillner, Jan and Kopp, R{\"u}diger and Finocchiaro, Thomas}, title = {Assistierte Zirkulation : ein {\"U}berblick aus klinischer Sicht = Assisted circulation: an overview from a clinical perspective / Spillner, Jan ; Kopp, R{\"u}diger ; Finocchiaro, Thomas ; Behbahani, Mehdi ; Rossaint, Rolf ; Steinseifer, Ulrich ; Behr, Marek ; Au}, series = {Biomedizinische Technik / Biomedical Engineering. 54 (2009), H. 5}, journal = {Biomedizinische Technik / Biomedical Engineering. 54 (2009), H. 5}, publisher = {De Gruyter}, address = {Berlin}, isbn = {0013-5585}, pages = {255 -- 267}, year = {2009}, language = {de} } @article{PogorelovaRogachevDigeletal.2020, author = {Pogorelova, Natalia and Rogachev, Evgeniy and Digel, Ilya and Chernigova, Svetlana and Nardin, Dmitry}, title = {Bacterial Cellulose Nanocomposites: Morphology and Mechanical Properties}, series = {Materials}, volume = {13}, journal = {Materials}, number = {12}, publisher = {MDPI}, address = {Basel}, isbn = {1996-1944}, doi = {10.3390/ma13122849}, pages = {1 -- 16}, year = {2020}, abstract = {Bacterial cellulose (BC) is a promising material for biomedical applications due to its unique properties such as high mechanical strength and biocompatibility. This article describes the microbiological synthesis, modification, and characterization of the obtained BC-nanocomposites originating from symbiotic consortium Medusomyces gisevii. Two BC-modifications have been obtained: BC-Ag and BC-calcium phosphate (BC-Ca3(PO4)2). Structure and physicochemical properties of the BC and its modifications were investigated by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), atomic force microscopy (AFM), and infrared Fourier spectroscopy as well as by measurements of mechanical and water holding/absorbing capacities. Topographic analysis of the surface revealed multicomponent thick fibrils (150-160 nm in diameter and about 15 µm in length) constituted by 50-60 nm nanofibrils weaved into a left-hand helix. Distinctive features of Ca-phosphate-modified BC samples were (a) the presence of 500-700 nm entanglements and (b) inclusions of Ca3(PO4)2 crystals. The samples impregnated with Ag nanoparticles exhibited numerous roundish inclusions, about 110 nm in diameter. The boundaries between the organic and inorganic phases were very distinct in both cases. The Ag-modified samples also showed a prominent waving pattern in the packing of nanofibrils. The obtained BC gel films possessed water-holding capacity of about 62.35 g/g. However, the dried (to a constant mass) BC-films later exhibited a low water absorption capacity (3.82 g/g). It was found that decellularized BC samples had 2.4 times larger Young's modulus and 2.2 times greater tensile strength as compared to dehydrated native BC films. We presume that this was caused by molecular compaction of the BC structure.}, language = {en} } @article{DigelAkimbekovRogachevetal.2023, author = {Digel, Ilya and Akimbekov, Nuraly and Rogachev, Evgeniy and Pogorelova, Natalia}, title = {Bacterial cellulose produced by Medusomyces gisevii on glucose and sucrose: biosynthesis and structural properties}, series = {Cellulose}, journal = {Cellulose}, publisher = {Springer Science + Business Media}, address = {Dordrecht}, issn = {1572-882X (Online)}, doi = {10.1007/s10570-023-05592-z}, pages = {15 Seiten}, year = {2023}, abstract = {In this work, the effects of carbon sources and culture media on the production and structural properties of bacterial cellulose (BC) synthesized by Medusomyces gisevii have been studied. The culture medium was composed of different initial concentrations of glucose or sucrose dissolved in 0.4\% extract of plain green tea. Parameters of the culture media (titratable acidity, substrate conversion degree etc.) were monitored daily for 20 days of cultivation. The BC pellicles produced on different carbon sources were characterized in terms of biomass yield, crystallinity and morphology by field emission scanning electron microscopy (FE-SEM), atomic force microscopy and X-ray diffraction. Our results showed that Medusomyces gisevii had higher BC yields in media with sugar concentrations close to 10 g L-1 after a 18-20 days incubation period. Glucose in general lead to a higher BC yield (173 g L-1) compared to sucrose (163.5 g L-1). The BC crystallinity degree and surface roughness were higher in the samples synthetized from sucrose. Obtained FE-SEM micrographs show that the BC pellicles synthesized in the sucrose media contained densely packed tangles of cellulose fibrils whereas the BC produced in the glucose media displayed rather linear geometry of the BC fibrils without noticeable aggregates.}, language = {en} } @article{DigelTemizArtmannNishikawaetal.2005, author = {Digel, Ilya and Temiz Artmann, Ayseg{\"u}l and Nishikawa, K. and Cook, M.}, title = {Bactericidal effects of plasma-generated cluster ions}, series = {Medical and Biological Engineering and Computing. 43 (2005), H. 6}, journal = {Medical and Biological Engineering and Computing. 43 (2005), H. 6}, isbn = {1741-0444}, pages = {800 -- 807}, year = {2005}, language = {en} } @article{Staat2000, author = {Staat, Manfred}, title = {Basis Reduction for the Shakedown Problem for Bounded Kinematic Hardening Material}, year = {2000}, abstract = {Limit and shakedown analysis are effective methods for assessing the load carrying capacity of a given structure. The elasto-plastic behavior of the structure subjected to loads varying in a given load domain is characterized by the shakedown load factor, defined as the maximum factor which satisfies the sufficient conditions stated in the corresponding static shakedown theorem. The finite element dicretization of the problem may lead to very large convex optimization. For the effective solution a basis reduction method has been developed that makes use of the special problem structure for perfectly plastic material. The paper proposes a modified basis reduction method for direct application to the two-surface plasticity model of bounded kinematic hardening material. The considered numerical examples show an enlargement of the load carrying capacity due to bounded hardening.}, subject = {Finite-Elemente-Methode}, language = {en} } @article{MansurovDigelBiisenbaevetal.2012, author = {Mansurov, Z. and Digel, Ilya and Biisenbaev, M. and Savistkaya, I. and Kistaubaeva, A. and Akimbekov, N. and Zhubanova, A.}, title = {Bio-composite material on the basis of carbonized rice husk in biomedicine and environmental applications}, series = {Eurasian Chemico-Technological Journal}, volume = {14}, journal = {Eurasian Chemico-Technological Journal}, number = {2}, publisher = {Institute of Combustion Problems}, address = {Almaty}, issn = {2522-4867}, doi = {10.18321/ectj105}, pages = {115 -- 131}, year = {2012}, language = {en} } @article{UysalCreutzFiratetal.2022, author = {Uysal, Karya and Creutz, Till and Firat, Ipek Seda and Artmann, Gerhard and Teusch, Nicole and Temiz Artmann, Ayseg{\"u}l}, title = {Bio-functionalized ultra-thin, large-area and waterproof silicone membranes for biomechanical cellular loading and compliance experiments}, series = {Polymers}, volume = {14}, journal = {Polymers}, number = {11}, publisher = {MDPI}, address = {Basel}, issn = {2073-4360}, pages = {2213}, year = {2022}, abstract = {Biocompatibility, flexibility and durability make polydimethylsiloxane (PDMS) membranes top candidates in biomedical applications. CellDrum technology uses large area, <10 µm thin membranes as mechanical stress sensors of thin cell layers. For this to be successful, the properties (thickness, temperature, dust, wrinkles, etc.) must be precisely controlled. The following parameters of membrane fabrication by means of the Floating-on-Water (FoW) method were investigated: (1) PDMS volume, (2) ambient temperature, (3) membrane deflection and (4) membrane mechanical compliance. Significant differences were found between all PDMS volumes and thicknesses tested (p < 0.01). They also differed from the calculated values. At room temperatures between 22 and 26 °C, significant differences in average thickness values were found, as well as a continuous decrease in thicknesses within a 4 °C temperature elevation. No correlation was found between the membrane thickness groups (between 3-4 µm) in terms of deflection and compliance. We successfully present a fabrication method for thin bio-functionalized membranes in conjunction with a four-step quality management system. The results highlight the importance of tight regulation of production parameters through quality control. The use of membranes described here could also become the basis for material testing on thin, viscous layers such as polymers, dyes and adhesives, which goes far beyond biological applications.}, language = {en} } @article{AkimbekovDigelTastambeketal.2013, author = {Akimbekov, N. S. and Digel, Ilya and Tastambek, K. T. and Zhubanova, A. A.}, title = {Biocompatibility of carbonized rice husk with a rat heart cells line H9c2}, series = {Experimental Biology}, volume = {59}, journal = {Experimental Biology}, number = {3/1}, issn = {1563-0218}, pages = {23 -- 25}, year = {2013}, language = {en} } @article{MaggakisKelemenBorkKayseretal.2003, author = {Maggakis-Kelemen, C. and Bork, M. and Kayser, Peter and Biselli, Manfred and Artmann, Gerhard}, title = {Biological and mechanical quality of red blood cells cultured from human umbilical cord blood stem cells}, series = {Medical and biological engineering and computing. 41 (2003), H. 3}, journal = {Medical and biological engineering and computing. 41 (2003), H. 3}, isbn = {0140-0118}, pages = {350 -- 356}, year = {2003}, language = {en} } @article{KotliarKoshitzSvetlowaetal.2005, author = {Kotliar, Konstantin and Koshitz, I. N. and Svetlowa, O. V. and Makarov, F. N.}, title = {Biomechanical analysis of traditional and contemporary conceptions on pathogenesis of the primary open angle glaucoma / Koshitz, I. N. ; Svetlova, O. V. ; Kotliar, K. E. ; Makarov, F. N. ; Smolnikov, B. A.}, series = {Glaukoma (2005)}, journal = {Glaukoma (2005)}, publisher = {-}, pages = {41 -- 63}, year = {2005}, language = {en} } @article{HorbachStaatPerezVianaetal.2020, author = {Horbach, Andreas and Staat, Manfred and Perez-Viana, Daniel and Simmen, Hans-Peter and Neuhaus, Valentin and Pape, Hans-Christoph and Prescher, Andreas and Ciritsis, Bernhard}, title = {Biomechanical in vitro examination of a standardized low-volume tubular femoroplasty}, series = {Clinical Biomechanics}, volume = {80}, journal = {Clinical Biomechanics}, number = {Art. 105104}, publisher = {Elsevier}, address = {Amsterdam}, doi = {10.1016/j.clinbiomech.2020.105104}, year = {2020}, abstract = {Background Osteoporosis is associated with the risk of fractures near the hip. Age and comorbidities increase the perioperative risk. Due to the ageing population, fracture of the proximal femur also proves to be a socio-economic problem. Preventive surgical measures have hardly been used so far. Methods 10 pairs of human femora from fresh cadavers were divided into control and low-volume femoroplasty groups and subjected to a Hayes fall-loading fracture test. The results of the respective localization and classification of the fracture site, the Singh index determined by computed tomography (CT) examination and the parameters in terms of fracture force, work to fracture and stiffness were evaluated statistically and with the finite element method. In addition, a finite element parametric study with different position angles and variants of the tubular geometry of the femoroplasty was performed. Findings Compared to the control group, the work to fracture could be increased by 33.2\%. The fracture force increased by 19.9\%. The used technique and instrumentation proved to be standardized and reproducible with an average poly(methyl methacrylate) volume of 10.5 ml. The parametric study showed the best results for the selected angle and geometry. Interpretation The cadaver studies demonstrated the biomechanical efficacy of the low-volume tubular femoroplasty. The numerical calculations confirmed the optimal choice of positioning as well as the inner and outer diameter of the tube in this setting. The standardized minimally invasive technique with the instruments developed for it could be used in further comparative studies to confirm the measured biomechanical results.}, language = {en} } @article{KotliarLanzl2002, author = {Kotliar, Konstantin and Lanzl, I. M.}, title = {Biomechanical modeling of the aqueous humor outflow after non-penetrating glaucoma filtration surgery in the human eye}, series = {Acta of bioengineering and biomechanics}, volume = {Vol. 4}, journal = {Acta of bioengineering and biomechanics}, number = {Suppl. 1}, issn = {1509-409X}, pages = {728 -- 729}, year = {2002}, language = {de} } @article{KotliarSvetlovaSourjikovetal.2004, author = {Kotliar, Konstantin and Svetlova, O. V. and Sourjikov, A. V. and Zaseeva, M. V.}, title = {Biomechanical peculiarities of aqueous humor production system and outflow regulation system / Svetlova, O. V. ; Sourjikov, A. V. ; Kotliar, K. E. ; Zaseeva, M. V. ; Shukhaev, S. V. ; Koshitz, I. N.}, series = {Glaukoma (2004)}, journal = {Glaukoma (2004)}, publisher = {-}, pages = {66 -- 76}, year = {2004}, language = {en} } @article{KotliarSvetlovaStegaevetal.2004, author = {Kotliar, Konstantin and Svetlova, O. V. and Stegaev, V. A. and Parkhomov, S. D.}, title = {Biomechanical substantiation of relatively low efficiency of recurrent laser trabeculoplasty / Svetlova, O. V. ; Stagaev, V. A. ; Parkhomov, S. D. ; Kotliar, K. E. ; Makarov, F. N. ; Smolnikov, B. A. ; Koshitz, I. N.}, series = {Glaukoma (2004)}, journal = {Glaukoma (2004)}, publisher = {-}, pages = {29 -- 39}, year = {2004}, language = {en} } @article{QuittmannAbelAlbrachtetal.2022, author = {Quittmann, Oliver J. and Abel, Thomas and Albracht, Kirsten and Str{\"u}der, Heiko K.}, title = {Biomechanics of all-out handcycling exercise: kinetics, kinematics and muscular activity of a 15-s sprint test in able-bodied participants}, series = {Sports Biomechanics}, volume = {21}, journal = {Sports Biomechanics}, number = {10}, publisher = {Taylor \& Francis}, address = {London}, issn = {1752-6116 (Onlineausgabe)}, doi = {10.1080/14763141.2020.1745266}, pages = {1200 -- 1223}, year = {2022}, abstract = {This study aims to quantify the kinematics, kinetics and muscular activity of all-out handcycling exercise and examine their alterations during the course of a 15-s sprint test. Twelve able-bodied competitive triathletes performed a 15-s all-out sprint test in a recumbent racing handcycle that was attached to an ergometer. During the sprint test, tangential crank kinetics, 3D joint kinematics and muscular activity of 10 muscles of the upper extremity and trunk were examined using a power metre, motion capturing and surface electromyography (sEMG), respectively. Parameters were compared between revolution one (R1), revolution two (R2), the average of revolution 3 to 13 (R3) and the average of the remaining revolutions (R4). Shoulder abduction and internal-rotation increased, whereas maximal shoulder retroversion decreased during the sprint. Except for the wrist angles, angular velocity increased for every joint of the upper extremity. Several muscles demonstrated an increase in muscular activation, an earlier onset of muscular activation in crank cycle and an increased range of activation. During the course of a 15-s all-out sprint test in handcycling, the shoulder muscles and the muscles associated to the push phase demonstrate indications for short-duration fatigue. These findings are helpful to prevent injuries and improve performance in all-out handcycling.}, language = {en} } @article{QuittmannAbelAlbrachtetal.2020, author = {Quittmann, Oliver J. and Abel, Thomas and Albracht, Kirsten and Meskemper, Joshua and Foitschik, Tina and Str{\"u}der, Heiko K.}, title = {Biomechanics of handcycling propulsion in a 30-min continuous load test at lactate threshold: Kinetics, kinematics, and muscular activity in able-bodied participants}, series = {European Journal of Applied Physiology}, journal = {European Journal of Applied Physiology}, number = {120}, publisher = {Springer}, address = {Heidelberg}, issn = {1439-6327}, doi = {10.1007/s00421-020-04373-x}, pages = {1403 -- 1415}, year = {2020}, abstract = {Purpose This study aims to investigate the biomechanics of handcycling during a continuous load trial (CLT) to assess the mechanisms underlying fatigue in upper body exercise. Methods Twelve able-bodied triathletes performed a 30-min CLT at a power output corresponding to lactate threshold in a racing recumbent handcycle mounted on a stationary ergometer. During the CLT, ratings of perceived exertion (RPE), tangential crank kinetics, 3D joint kinematics, and muscular activity of ten muscles of the upper extremity and trunk were examined using motion capturing and surface electromyography. Results During the CLT, spontaneously chosen cadence and RPE increased, whereas crank torque decreased. Rotational work was higher during the pull phase. Peripheral RPE was higher compared to central RPE. Joint range of motion decreased for elbow-flexion and radial-duction. Integrated EMG (iEMG) increased in the forearm flexors, forearm extensors, and M. deltoideus (Pars spinalis). An earlier onset of activation was found for M. deltoideus (Pars clavicularis), M. pectoralis major, M. rectus abdominis, M. biceps brachii, and the forearm flexors. Conclusion Fatigue-related alterations seem to apply analogously in handcycling and cycling. The most distal muscles are responsible for force transmission on the cranks and might thus suffer most from neuromuscular fatigue. The findings indicate that peripheral fatigue (at similar lactate values) is higher in handcycling compared to leg cycling, at least for inexperienced participants. An increase in cadence might delay peripheral fatigue by a reduced vascular occlusion. We assume that the gap between peripheral and central fatigue can be reduced by sport-specific endurance training.}, language = {en} } @article{KotliarVolkovKoshitsetal.1997, author = {Kotliar, Konstantin and Volkov, V. V. and Koshits, I. N. and Svetlova, O. V.}, title = {Biomekhanicheskie osobennosti vzaimodeĭstviia drenazhno i akkomodatsionnoĭ reguliatornykh sistem glaza v norme i pri kontuzionnom podvyvikhe khrustalika / Volkov, V. V. ; Kotliar, K. E. ; Koshits, I. n. ; Svetlova, O. V. ; Smol´nikov, B. A.}, series = {Vestnik oftalmologii. 113 (1997), H. 3}, journal = {Vestnik oftalmologii. 113 (1997), H. 3}, publisher = {-}, isbn = {0042-465X}, pages = {5 -- 7}, year = {1997}, language = {en} } @article{BorkKelemenBisellietal.2000, author = {Bork, M. and Kelemen, C. and Biselli, Manfred and Artmann, Gerhard}, title = {Biophysikalische Charakterisierung ex vivo kultivierter menschlicher Erythrozythen}, series = {Biomedizinische Technik = Biomedical Engineering. 45 (2000), H. s1}, journal = {Biomedizinische Technik = Biomedical Engineering. 45 (2000), H. s1}, isbn = {1862-278X}, pages = {471 -- 472}, year = {2000}, language = {de} } @article{AkimbekovDigelTastambeketal.2022, author = {Akimbekov, Nuraly S. and Digel, Ilya and Tastambek, Kuanysh T. and Marat, Adel K. and Turaliyeva, Moldir A. and Kaiyrmanova, Gulzhan K.}, title = {Biotechnology of Microorganisms from Coal Environments: From Environmental Remediation to Energy Production}, series = {Biology}, volume = {11}, journal = {Biology}, number = {9}, publisher = {MDPI}, address = {Basel}, issn = {2079-7737}, doi = {10.3390/biology11091306}, pages = {47 Seiten}, year = {2022}, abstract = {It was generally believed that coal sources are not favorable as live-in habitats for microorganisms due to their recalcitrant chemical nature and negligible decomposition. However, accumulating evidence has revealed the presence of diverse microbial groups in coal environments and their significant metabolic role in coal biogeochemical dynamics and ecosystem functioning. The high oxygen content, organic fractions, and lignin-like structures of lower-rank coals may provide effective means for microbial attack, still representing a greatly unexplored frontier in microbiology. Coal degradation/conversion technology by native bacterial and fungal species has great potential in agricultural development, chemical industry production, and environmental rehabilitation. Furthermore, native microalgal species can offer a sustainable energy source and an excellent bioremediation strategy applicable to coal spill/seam waters. Additionally, the measures of the fate of the microbial community would serve as an indicator of restoration progress on post-coal-mining sites. This review puts forward a comprehensive vision of coal biodegradation and bioprocessing by microorganisms native to coal environments for determining their biotechnological potential and possible applications.}, language = {en} } @article{DigelMaggakisKelemenZerlinetal.2006, author = {Digel, Ilya and Maggakis-Kelemen, Christina and Zerlin, Kay and Linder, Peter}, title = {Body temperature-related structural transitions of monotremal and human hemoglobin}, series = {Biophysical Journal. 91 (2006), H. 8}, journal = {Biophysical Journal. 91 (2006), H. 8}, isbn = {1542-0086}, pages = {3014 -- 3021}, year = {2006}, language = {en} } @article{BirgelLeschingerWegmannetal.2018, author = {Birgel, Stefan and Leschinger, Tim and Wegmann, Kilian and Staat, Manfred}, title = {Calculation of muscle forces and joint reaction loads in the shoulder area via an OpenSim based computer model}, series = {tm - Technisches Messen}, volume = {85}, journal = {tm - Technisches Messen}, number = {5}, publisher = {De Gruyter}, address = {Berlin}, issn = {2196-7113}, doi = {10.1515/teme-2017-0114}, pages = {321 -- 330}, year = {2018}, abstract = {Using the OpenSim software and verified anatomical data, a computer model for the calculation of biomechanical parameters is developed and used to determine the effect of a reattachment of the Supraspinatus muscle with a medial displacement of the muscle attachment point, which may be necessary for a rupture of the supraspinatus tendon. The results include the influence of the operation on basic biomechanical parameters such as the lever arm, as well as the calculated the muscle activations for the supraspinatus and deltoid. In addition, the influence on joint stability is examined by an analysis of the joint reaction force. The study provides a detailed description of the used model, as well as medical findings to a reattachment of the supraspinatus. Mit der Software OpenSim und {\"u}berpr{\"u}ften anatomischen Daten wird ein Computermodell zur Berechnung von biomechanischen Parametern entwickelt und genutzt, um den Effekt einer Refixierung des Supraspinatusmuskels mit einer medialen Verschiebung des Muskelansatzpunktes zu ermitteln, wie sie unter anderem nach einem Riss der Supraspinatussehne notwendig sein kann. Die Ergebnisse umfassen hierbei den Einfluss der Operation auf grundlegende biomechanische Parameter wie den Hebelarm sowie die berechneten Muskelaktivierungen f{\"u}r den Supraspinatus und Deltoideus. Zus{\"a}tzlich wird der Einfluss auf die Gelenkstabilit{\"a}t betrachtet und durch eine Analyse der Gelenkreaktionskraft untersucht. Die Studie bietet eine detaillierte Beschreibung des genutzten Modells, sowie medizinische Erkenntnisse zu einer Refixierung des Supraspinatus.}, language = {en} } @article{BelavyAlbrachtBruggemannetal.2016, author = {Belavy, Daniel L. and Albracht, Kirsten and Bruggemann, Gert-Peter and Vergroesen, Pieter-Paul A. and Dieen, Jaap H. van}, title = {Can exercise positively influence the intervertebral disc?}, series = {Sports Medicine}, volume = {46}, journal = {Sports Medicine}, number = {4}, publisher = {Springer}, address = {Berlin}, issn = {1179-2035}, doi = {10.1007/s40279-015-0444-2}, pages = {473 -- 485}, year = {2016}, abstract = {To better understand what kinds of sports and exercise could be beneficial for the intervertebral disc (IVD), we performed a review to synthesise the literature on IVD adaptation with loading and exercise. The state of the literature did not permit a systematic review; therefore, we performed a narrative review. The majority of the available data come from cell or whole-disc loading models and animal exercise models. However, some studies have examined the impact of specific sports on IVD degeneration in humans and acute exercise on disc size. Based on the data available in the literature, loading types that are likely beneficial to the IVD are dynamic, axial, at slow to moderate movement speeds, and of a magnitude experienced in walking and jogging. Static loading, torsional loading, flexion with compression, rapid loading, high-impact loading and explosive tasks are likely detrimental for the IVD. Reduced physical activity and disuse appear to be detrimental for the IVD. We also consider the impact of genetics and the likelihood of a 'critical period' for the effect of exercise in IVD development. The current review summarises the literature to increase awareness amongst exercise, rehabilitation and ergonomic professionals regarding IVD health and provides recommendations on future directions in research.}, language = {en} } @article{KotliarLanzl2011, author = {Kotliar, Konstantin and Lanzl, Ines M.}, title = {Can vascular function be assessed by the interpretation of retinal vascular diameter changes?}, series = {Investigative Ophthalmology \& Visual Science, IOVS. 52 (2011), H. 1}, journal = {Investigative Ophthalmology \& Visual Science, IOVS. 52 (2011), H. 1}, publisher = {ARVO}, address = {Rockville, Md.}, isbn = {0146-0404}, pages = {635 -- 636}, year = {2011}, language = {en} } @article{TemizArtmannYalcinResmietal.2002, author = {Temiz Artmann, Ayseg{\"u}l and Yalcin, Ozlem and Resmi, Halil and Baskurt, Oguz K.}, title = {Can white blood cell activation be one of the major factors that affect hemorheological parameters during and after exercise?}, series = {Clinical Hemorheology and Microcirculation. 26 (2002), H. 3}, journal = {Clinical Hemorheology and Microcirculation. 26 (2002), H. 3}, isbn = {1386-0291}, pages = {189 -- 193}, year = {2002}, language = {en} } @article{JanThimoBauerBieleetal.2019, author = {Jan Thimo, Grundmann and Bauer, Waldemar and Biele, Jens and Boden, Ralf and Ceriotti, Matteo and Cordero, Federico and Dachwald, Bernd and Dumont, Etienne and Grimm, Christian D. and Hercik, David}, title = {Capabilities of Gossamer-1 derived small spacecraft solar sails carrying Mascot-derived nanolanders for in-situ surveying of NEAs}, series = {Acta Astronautica}, volume = {156}, journal = {Acta Astronautica}, number = {3}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0094-5765}, doi = {10.1016/j.actaastro.2018.03.019}, pages = {330 -- 362}, year = {2019}, language = {en} } @article{Artmann2000, author = {Artmann, Gerhard}, title = {Cellular engineering - a challenge for engineers? / Artmann, G. M.}, series = {Biomedizinische Technik = Biomedical Engineering. 45 (2000), H. s1}, journal = {Biomedizinische Technik = Biomedical Engineering. 45 (2000), H. s1}, isbn = {1862-278X}, pages = {449}, year = {2000}, language = {en} } @article{ArtmannKelemenPorstetal.1998, author = {Artmann, Gerhard and Kelemen, C. and Porst, Dariusz and B{\"u}ldt, G.}, title = {Cellular engineering: Crash tests an menschlichen Erythrozyten geben Aufschluß {\"u}ber versteckte Materialeigenschaften zellul{\"a}rer Proteine / Artmann, G. M. ; Kelemen, Ch. ; Porst, D. ; B{\"u}ldt, G. ; Chien, Shu}, series = {Biomedizinische Technik / Biomedical Engineering. 43 (1998), H. s1}, journal = {Biomedizinische Technik / Biomedical Engineering. 43 (1998), H. s1}, isbn = {1862-278}, pages = {446 -- 447}, year = {1998}, language = {en} } @article{BehbahaniBehrAroraetal.2006, author = {Behbahani, Mehdi and Behr, M. and Arora, D. and Coronado, O. and Pasquali, M.}, title = {CFD Analysis of MicroMed Debakey Pump and Hemolysis Prediction / Behbahani, M. ; Behr, M. ; Arora, D. ; Coronado, O. ; Pasquali, M.}, series = {Artificial Organs. 30 (2006), H. 11}, journal = {Artificial Organs. 30 (2006), H. 11}, isbn = {1525-1594}, pages = {A45 -- A46}, year = {2006}, language = {en} } @article{NeumaierWeissVeldemanetal.2021, author = {Neumaier, Felix and Weiss, Miriam and Veldeman, Michael and Kotliar, Konstantin and Wiesmann, Martin and Schulze-Steinen, Henna and H{\"o}llig, Anke and Clusmann, Hans and Schubert, Gerrit Alexander and Albanna, Walid}, title = {Changes in endogenous daytime melatonin levels after aneurysmal subarachnoid hemorrhage - preliminary findings from an observational cohort study}, series = {Clinical Neurology and Neurosurgery}, volume = {208}, journal = {Clinical Neurology and Neurosurgery}, number = {Article No.: 106870}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0303-8467}, doi = {10.1016/j.clineuro.2021.106870}, year = {2021}, abstract = {Aneurysmal subarachnoid hemorrhage (aSAH) is associated with early and delayed brain injury due to several underlying and interrelated processes, which include inflammation, oxidative stress, endothelial, and neuronal apoptosis. Treatment with melatonin, a cytoprotective neurohormone with anti-inflammatory, anti-oxidant and anti-apoptotic effects, has been shown to attenuate early brain injury (EBI) and to prevent delayed cerebral vasospasm in experimental aSAH models. Less is known about the role of endogenous melatonin for aSAH outcome and how its production is altered by the pathophysiological cascades initiated during EBI. In the present observational study, we analyzed changes in melatonin levels during the first three weeks after aSAH.}, language = {en} } @article{WaldvogelFreylerHelmetal.2023, author = {Waldvogel, Janice and Freyler, Kathrin and Helm, Michael and Monti, Elena and St{\"a}udle, Benjamin and Gollhofer, Albert and Narici, Marco V. and Ritzmann, Ramona and Albracht, Kirsten}, title = {Changes in gravity affect neuromuscular control, biomechanics, and muscle-tendon mechanics in energy storage and dissipation tasks}, series = {Journal of Applied Physiology}, volume = {134}, journal = {Journal of Applied Physiology}, number = {1}, publisher = {American Physiological Society}, address = {Bethesda, Md.}, issn = {1522-1601 (Onlineausgabe)}, doi = {10.1152/japplphysiol.00279.2022}, pages = {190 -- 202}, year = {2023}, abstract = {This study evaluates neuromechanical control and muscle-tendon interaction during energy storage and dissipation tasks in hypergravity. During parabolic flights, while 17 subjects performed drop jumps (DJs) and drop landings (DLs), electromyography (EMG) of the lower limb muscles was combined with in vivo fascicle dynamics of the gastrocnemius medialis, two-dimensional (2D) kinematics, and kinetics to measure and analyze changes in energy management. Comparisons were made between movement modalities executed in hypergravity (1.8 G) and gravity on ground (1 G). In 1.8 G, ankle dorsiflexion, knee joint flexion, and vertical center of mass (COM) displacement are lower in DJs than in DLs; within each movement modality, joint flexion amplitudes and COM displacement demonstrate higher values in 1.8 G than in 1 G. Concomitantly, negative peak ankle joint power, vertical ground reaction forces, and leg stiffness are similar between both movement modalities (1.8 G). In DJs, EMG activity in 1.8 G is lower during the COM deceleration phase than in 1 G, thus impairing quasi-isometric fascicle behavior. In DLs, EMG activity before and during the COM deceleration phase is higher, and fascicles are stretched less in 1.8 G than in 1 G. Compared with the situation in 1 G, highly task-specific neuromuscular activity is diminished in 1.8 G, resulting in fascicle lengthening in both movement modalities. Specifically, in DJs, a high magnitude of neuromuscular activity is impaired, resulting in altered energy storage. In contrast, in DLs, linear stiffening of the system due to higher neuromuscular activity combined with lower fascicle stretch enhances the buffering function of the tendon, and thus the capacity to safely dissipate energy.}, language = {en} } @article{FeuchtSchoenbachLanzletal.2013, author = {Feucht, Nikolaus and Sch{\"o}nbach, Etienne Michael and Lanzl, Ines and Kotliar, Konstantin and Lohmann, Chris Patrick and Maier, Mathias}, title = {Changes in the foveal microstructure after intravitreal bevacizumab application in patients with retinal vascular disease}, series = {Clinical Ophthalmology}, volume = {7}, journal = {Clinical Ophthalmology}, publisher = {Dove Medical Press}, address = {Auckland, New Zealand}, issn = {1177-5483}, pages = {173 -- 178}, year = {2013}, language = {en} } @article{ArtmannHueckHollwegetal.2000, author = {Artmann, Gerhard and Hueck, I. S. and Hollweg, H. G. and Schmid-Sch{\"o}nbein, G. W.}, title = {Chlorpromazine modulates the Morphological Macro- and Microstructure of Endothelial Cells. Hueck, I. S.; Hollweg, H. G.; Schmid-Sch{\"o}nbein, G. W.; Artmann, Gerhard Michael}, series = {American Journal of Physiology. Cell Physiology. 278 (2000), H. 5}, journal = {American Journal of Physiology. Cell Physiology. 278 (2000), H. 5}, isbn = {1522-1563}, pages = {873 -- 878}, year = {2000}, language = {en} } @article{ArtmannBurnsCanavesetal.2004, author = {Artmann, Gerhard and Burns, Laura and Canaves, Jaume M. and Temiz Artmann, Ayseg{\"u}l}, title = {Circular dichroism spectra of human hemoglobin reveal a reversible structural transition at body temperature}, series = {European Biophysics Journal. 33 (2004), H. 6}, journal = {European Biophysics Journal. 33 (2004), H. 6}, isbn = {1432-1017}, pages = {490 -- 496}, year = {2004}, language = {en} } @article{DigelTemizArtmannNishikawaetal.2004, author = {Digel, Ilya and Temiz Artmann, Ayseg{\"u}l and Nishikawa, K. and Artmann, Gerhard}, title = {Cluster air-ion effects on bacteria and moulds}, series = {Biomedizinische Technik. 49 (2004), H. Erg.-Bd. 2}, journal = {Biomedizinische Technik. 49 (2004), H. Erg.-Bd. 2}, isbn = {0932-4666}, pages = {1040 -- 1041}, year = {2004}, language = {en} } @article{AngermannGuenthnerHanssenetal.2022, author = {Angermann, Susanne and G{\"u}nthner, Roman and Hanssen, Henner and Lorenz, Georg and Braunisch, Matthias C. and Steubl, Dominik and Matschkal, Julia and Kemmner, Stephan and Hausinger, Renate and Block, Zenonas and Haller, Bernhard and Heemann, Uwe and Kotliar, Konstantin and Grimmer, Timo and Schmaderer, Christoph}, title = {Cognitive impairment and microvascular function in end-stage renal disease}, series = {International Journal of Methods in Psychiatric Research (MPR)}, volume = {31}, journal = {International Journal of Methods in Psychiatric Research (MPR)}, number = {2}, publisher = {Wiley}, issn = {1049-8931 (Print)}, doi = {10.1002/mpr.1909}, pages = {1 -- 10}, year = {2022}, abstract = {Objective Hemodialysis patients show an approximately threefold higher prevalence of cognitive impairment compared to the age-matched general population. Impaired microcirculatory function is one of the assumed causes. Dynamic retinal vessel analysis is a quantitative method for measuring neurovascular coupling and microvascular endothelial function. We hypothesize that cognitive impairment is associated with altered microcirculation of retinal vessels. Methods 152 chronic hemodialysis patients underwent cognitive testing using the Montreal Cognitive Assessment. Retinal microcirculation was assessed by Dynamic Retinal Vessel Analysis, which carries out an examination recording retinal vessels' reaction to a flicker light stimulus under standardized conditions. Results In unadjusted as well as in adjusted linear regression analyses a significant association between the visuospatial executive function domain score of the Montreal Cognitive Assessment and the maximum arteriolar dilation as response of retinal arterioles to the flicker light stimulation was obtained. Conclusion This is the first study determining retinal microvascular function as surrogate for cerebral microvascular function and cognition in hemodialysis patients. The relationship between impairment in executive function and reduced arteriolar reaction to flicker light stimulation supports the involvement of cerebral small vessel disease as contributing factor for the development of cognitive impairment in this patient population and might be a target for noninvasive disease monitoring and therapeutic intervention.}, language = {en} } @article{KnoxBruggemannGossmannetal.2020, author = {Knox, Ronald and Bruggemann, Andrea and Gossmann, Matthias and Thomas, Ulrich and Horv{\´a}th, Andr{\´a}s and Dragicevic, Elena and Stoelzle-Feix, Sonja and Fertig, Niels and Jung, Alexander and Raman, Aravind Hariharan and Staat, Manfred and Linder, Peter}, title = {Combining physiological relevance and throughput for in vitro cardiac contractility measurement}, series = {Biophysical Journal}, volume = {118}, journal = {Biophysical Journal}, number = {Issue 3, Supplement 1}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0006-3495}, doi = {10.1016/j.bpj.2019.11.3104}, pages = {570a}, year = {2020}, abstract = {Despite increasing acceptance of human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) in safety pharmacology, controversy remains about the physiological relevance of existing in vitro models for their mechanical testing. We hypothesize that existing signs of immaturity of the cell models result from an improper mechanical environment. We cultured hiPSC-CMs in a 96-well format on hyperelastic silicone membranes imitating their native mechanical environment, resulting in physiological responses to compound stimuli.We validated cell responses on the FLEXcyte 96, with a set of reference compounds covering a broad range of cellular targets, including ion channel modulators, adrenergic receptor modulators and kinase inhibitors. Acute (10 - 30 min) and chronic (up to 7 days) effects were investigated. Furthermore, the measurements were complemented with electromechanical models based on electrophysiological recordings of the used cell types.hiPSC-CMs were cultured on freely-swinging, ultra-thin and hyperelastic silicone membranes. The weight of the cell culture medium deflects the membranes downwards. Rhythmic contraction of the hiPSC-CMs resulted in dynamic deflection changes which were quantified by capacitive distance sensing. The cells were cultured for 7 days prior to compound addition. Acute measurements were conducted 10-30 minutes after compound addition in standard culture medium. For chronic treatment, compound-containing medium was replaced daily for up to 7 days. Electrophysiological properties of the employed cell types were recorded by automated patch-clamp (Patchliner) and the results were integrated into the electromechanical model of the system.Calcium channel agonist S Bay K8644 and beta-adrenergic stimulator isoproterenol induced significant positive inotropic responses without additional external stimulation. Kinase inhibitors displayed cardiotoxic effects on a functional level at low concentrations. The system-integrated analysis detected alterations in beating shape as well as frequency and arrhythmic events and we provide a quantitative measure of these.}, language = {en} } @article{KetelhutGoellBraunsteinetal.2018, author = {Ketelhut, Maike and G{\"o}ll, Fabian and Braunstein, Bj{\"o}rn and Albracht, Kirsten and Abel, Dirk}, title = {Comparison of different training algorithms for the leg extension training with an industrial robot}, series = {Current Directions in Biomedical Engineering}, volume = {4}, journal = {Current Directions in Biomedical Engineering}, number = {1}, publisher = {De Gruyter}, address = {Berlin}, issn = {2364-5504}, doi = {10.1515/cdbme-2018-0005}, pages = {17 -- 20}, year = {2018}, abstract = {In the past, different training scenarios have been developed and implemented on robotic research platforms, but no systematic analysis and comparison have been done so far. This paper deals with the comparison of an isokinematic (motion with constant velocity) and an isotonic (motion against constant weight) training algorithm. Both algorithms are designed for a robotic research platform consisting of a 3D force plate and a high payload industrial robot, which allows leg extension training with arbitrary six-dimensional motion trajectories. In the isokinematic as well as the isotonic training algorithm, individual paths are defined i n C artesian s pace by sufficient s upport p oses. I n t he i sotonic t raining s cenario, the trajectory is adapted to the measured force as the robot should only move along the trajectory as long as the force applied by the user exceeds a minimum threshold. In the isotonic training scenario however, the robot's acceleration is a function of the force applied by the user. To validate these findings, a simulative experiment with a simple linear trajectory is performed. For this purpose, the same force path is applied in both training scenarios. The results illustrate that the algorithms differ in the force dependent trajectory adaption.}, language = {en} } @article{SchierenKleinschmidtSchmutzetal.2019, author = {Schieren, Mark and Kleinschmidt, Joris and Schmutz, Axel and Loop, Torsten and Gatzweiler, Karl-Heinz and Staat, Manfred and Wappler, Frank and Defosse, Jerome}, title = {Comparison of forces acting on maxillary incisors during tracheal intubation with different laryngoscopy techniques: a blinded manikin study}, series = {Anaesthesia}, volume = {74}, journal = {Anaesthesia}, number = {12}, publisher = {Wiley-Blackwell}, address = {Oxford}, isbn = {1365-2044}, doi = {10.1111/anae.14815}, year = {2019}, language = {en} } @article{StaatBallmann1988, author = {Staat, Manfred and Ballmann, J.}, title = {Computation of impacts on elastic solids by methods of bicharacteristics}, series = {Computational Mechanics '88 : theory and applications ; proceedings of the International Conference on Computational Engineering Science April 10-14, 1988, Atlanta, GA, USA ; vol. 2}, journal = {Computational Mechanics '88 : theory and applications ; proceedings of the International Conference on Computational Engineering Science April 10-14, 1988, Atlanta, GA, USA ; vol. 2}, pages = {1719 -- 1722}, year = {1988}, abstract = {Shock waves, explosions, impacts or cavitation bubble collapses may generate stress waves in solids causing cracks or unexpected dammage due to focussing, physical nonlinearity or interaction with existing cracks. There is a growing interest in wave propagation, which poses many novel problems to experimentalists and theorists.}, subject = {Bicharakteristikenverfahren}, language = {en} } @article{BehbahaniWalugaArltetal.2008, author = {Behbahani, Mehdi and Waluga, C. and Arlt, S. and Behr, M. and Mottaghy, K.}, title = {Computational Analysis of Platelet Aggregation in a Taylor-Couette System}, series = {The International Journal of Artificial Organs. 31 (2008), H. 7}, journal = {The International Journal of Artificial Organs. 31 (2008), H. 7}, isbn = {0391-3988}, pages = {643}, year = {2008}, language = {en} } @article{BhattaraiStaat2018, author = {Bhattarai, Aroj and Staat, Manfred}, title = {Computational comparison of different textile implants to correct apical prolapse in females}, series = {Current Directions in Biomedical Engineering}, volume = {4}, journal = {Current Directions in Biomedical Engineering}, number = {1}, publisher = {De Gruyter}, address = {Berlin}, doi = {10.1515/cdbme-2018-0159}, pages = {661 -- 664}, year = {2018}, abstract = {Prosthetic textile implants of different shapes, sizes and polymers are used to correct the apical prolapse after hysterectomy (removal of the uterus). The selection of the implant before or during minimally invasive surgery depends on the patient's anatomical defect, intended function after reconstruction and most importantly the surgeon's preference. Weakness or damage of the supporting tissues during childbirth, menopause or previous pelvic surgeries may put females in higher risk of prolapse. Numerical simulations of reconstructed pelvic floor with weakened tissues and organ supported by textile product models: DynaMesh®-PRS soft, DynaMesh®-PRP soft and DynaMesh®-CESA from FEG Textiletechnik mbH, Germany are compared.}, language = {en} }