@article{FleischhakerEvers2008, author = {Fleischhaker, Robert and Evers, J{\"o}rg}, title = {Nonlinear effects in pulse propagation through Doppler-broadened closed-loop atomic media}, series = {Physical Review A - Atomic, molecular, and optical physics}, volume = {77}, journal = {Physical Review A - Atomic, molecular, and optical physics}, number = {4}, issn = {1050-2947}, doi = {10.1103/PhysRevA.77.043805}, pages = {043805}, year = {2008}, language = {en} } @article{FleischhakerEversDey2010, author = {Fleischhaker, Robert and Evers, J{\"o}rg and Dey, Tarak N.}, title = {Phase modulation induced by cooperative effects in electromagnetically induced transparency}, series = {Physical Review A - Atomic, molecular, and optical physics}, volume = {82}, journal = {Physical Review A - Atomic, molecular, and optical physics}, number = {1}, publisher = {AIP Publishing}, address = {Melville, NY}, issn = {1050-2947}, doi = {10.1103/PhysRevA.82.013815}, pages = {013815}, year = {2010}, abstract = {We analyze the influence of dipole-dipole interactions in an electromagnetically induced transparency set up for a density at the onset of cooperative effects. To this end, we include mean-field models for the influence of local-field corrections and radiation trapping into our calculation. We show both analytically and numerically that the polarization contribution to the local field strongly modulates the phase of a weak pulse. We give an intuitive explanation for this local-field-induced phase modulation and demonstrate that it distinctively differs from the nonlinear self-phase-modulation that a strong pulse experiences in a Kerr medium.}, language = {en} } @article{FleischhakerEvers2011, author = {Fleischhaker, Robert and Evers, J{\"o}rg}, title = {A Maxwell-Schr{\"o}dinger solver for quantum optical few-level systems}, series = {Computer Physics Communications}, volume = {182}, journal = {Computer Physics Communications}, number = {3}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0010-4655}, doi = {10.1016/j.cpc.2010.10.018}, pages = {739 -- 747}, year = {2011}, abstract = {The msprop program presented in this work is capable of solving the Maxwell-Schr{\"o}dinger equations for one or several laser fields propagating through a medium of quantum optical few-level systems in one spatial dimension and in time. In particular, it allows to numerically treat systems in which a laser field interacts with the medium with both its electric and magnetic component at the same time. The internal dynamics of the few-level system is modeled by a quantum optical master equation which includes coherent processes due to optical transitions driven by the laser fields as well as incoherent processes due to decay and dephasing. The propagation dynamics of the laser fields is treated in slowly varying envelope approximation resulting in a first order wave equation for each laser field envelope function. The program employs an Adams predictor formula second order in time to integrate the quantum optical master equation and a Lax-Wendroff scheme second order in space and time to evolve the wave equations for the fields. The source function in the Lax-Wendroff scheme is specifically adapted to allow taking into account the simultaneous coupling of a laser field to the polarization and the magnetization of the medium. To reduce execution time, a customized data structure is implemented and explained. In three examples the features of the program are demonstrated and the treatment of a system with a phase-dependent cross coupling of the electric and magnetic field component of a laser field is shown.}, language = {en} } @article{FleischhakerKraussSchaettigeretal.2013, author = {Fleischhaker, Robert and Krauß, Nico and Sch{\"a}ttiger, Farina and Dekorsy, Thomas}, title = {Consistent characterization of semiconductor saturable absorber mirrors with singe-pulse and pump-probe spectroscopy}, series = {Optics Express}, volume = {21}, journal = {Optics Express}, number = {6}, publisher = {Optica}, address = {Washington, DC}, issn = {1094-4087}, doi = {10.1364/OE.21.006764}, pages = {6764 -- 6776}, year = {2013}, language = {en} } @article{MahmoudiFleischhakerSahraietal.2008, author = {Mahmoudi, Mohammad and Fleischhaker, Robert and Sahrai, Mostafa and Evers, J{\"o}rg}, title = {Group velocity control in the ultraviolet domain via interacting dark-state resonances}, series = {Journal of physics B: Atomic, molecular and optical physics}, volume = {41}, journal = {Journal of physics B: Atomic, molecular and optical physics}, number = {2}, issn = {0953-4075}, doi = {10.1088/0953-4075/41/2/025504}, pages = {25504 -- 25600}, year = {2008}, language = {en} } @article{Wollert2016, author = {Wollert, J{\"o}rg}, title = {Industrial Internet of Things : Seifenblase oder Revolution}, series = {Elektronik}, journal = {Elektronik}, number = {7}, publisher = {WEKA-Fachmedien}, address = {M{\"u}nchen}, issn = {0013-5658}, pages = {39 -- 45}, year = {2016}, language = {de} } @article{WegmannHacklStaatetal.2016, author = {Wegmann, Kilian and Hackl, Michael and Staat, Manfred and Mayer, Katharina and M{\"u}ller, Lars-Peter}, title = {Double plate osteosynthesis of proximal ulna fractures: biomechanical and clinical results}, series = {Knee surgery, sports traumatology, arthroscopy}, volume = {Volume 24}, journal = {Knee surgery, sports traumatology, arthroscopy}, number = {Supplement 1}, publisher = {Springer}, address = {Berlin}, issn = {0942-2056}, doi = {10.1007/s00167-016-4079-0}, pages = {58 -- 59}, year = {2016}, abstract = {While plate fixation of proximal ulna fractures might lead to superior clinical results compared to tension band wiring, regular plates represent an established risk factor for wound complications. The olecranon double plates (Medartis, Basel, CH) might decrease complications related to the osteosynthesis because of their low profile and better anatomical fit. This study aimed to evaluate the biomechanical performance and clinical results of the olecranon double plates.}, language = {en} } @article{HacklLeschingerStaatetal.2016, author = {Hackl, Michael and Leschinger, T. and Staat, Manfred and M{\"u}ller, Lars-Peter and Wegmann, Kilian}, title = {Reconstruction of the interosseous membrane in the Essex Lopresti lesion — a biomechanical evaluation}, series = {Knee surgery, sports traumatology, arthroscopy}, volume = {Volume 24}, journal = {Knee surgery, sports traumatology, arthroscopy}, number = {Supplement 1}, publisher = {Springer}, address = {Berlin}, issn = {0942-2056}, doi = {10.1007/s00167-016-4080-7}, pages = {130 -- 131}, year = {2016}, abstract = {Surgical reconstruction of the interosseous membrane (IOM) could restore longitudinal forearm stability to avoid persisting disability due to capituloradial and ulnocarpal impingement in Essex Lopresti lesions. This biomechanical study aimed to assess longitudinal forearm stability of intact specimens, after sectioning of the IOM and after reconstruction with a TightRope construct using either a single or double bundle technique.}, language = {en} } @article{HacklKahmannWegmannetal.2016, author = {Hackl, Michael and Kahmann, Stephanie Lucina and Wegmann, Kilian and Ries, Christian and Staat, Manfred and M{\"u}ller, Lars-Peter}, title = {Shortening osteotomy of the proximal radius — a treatment option for isolated osteoarthritis of the lateral column of the elbow joint?}, series = {Knee surgery, sports traumatology, arthroscopy}, volume = {Volume 24}, journal = {Knee surgery, sports traumatology, arthroscopy}, number = {Supplement 1}, publisher = {Springer}, address = {Berlin}, issn = {0942-2056}, doi = {10.1007/s00167-016-4080-7}, pages = {128 -- 129}, year = {2016}, abstract = {Treatment of posttraumatic osteoarthritis of the radial column of the elbow joint remains a challenging yet common issue. While partial joint replacement leads to high revision rates, radial head excision has shown to severely increase joint instability. Shortening osteotomy of the radius could be an option to decrease the contact pressure of the radiohumeral joint and thereby pain levels without causing valgus instability. Hence, the aim of this biomechanical study was to evaluate the effects of radial shortening on axial load distribution and valgus stability of the elbow joint.}, language = {en} } @article{HacklMuellerStaatetal.2016, author = {Hackl, Michael and M{\"u}ller, Lars-Peter and Staat, Manfred and Kahmann, Stephanie Lucina and Wegmann, Kilian}, title = {Proximal phalangeal neck fractures of the hand — a biomechanical comparison of three fixation techniques}, series = {Knee surgery, sports traumatology, arthroscopy}, volume = {Volume 24}, journal = {Knee surgery, sports traumatology, arthroscopy}, number = {Supplement 1}, publisher = {Springer}, address = {Berlin}, issn = {0942-2056}, doi = {10.1007/s00167-016-4080-7}, pages = {148 -- 149}, year = {2016}, abstract = {Plate osteosynthesis of displaced proximal phalangeal neck fractures of the hand allows early mobilization due to a stable internal fixation. Nevertheless, joint stiffness—because of soft tissue irritation—represents a common complication leading to high complication rates. Del Pinal et al. recently reported promising clinical results for a new, minimally invasive fixation technique with a cannulated headless intramedullary compression screw. Hence, the aim of this study was to compare plate fixation of proximal phalangeal neck fractures to less two less invasive techniques: Crossed k-wire fixation and intramedullary screw fixation. We hypothesized that these fixation techniques provide inferior stability when compared to plate osteosynthesis.}, language = {en} }