@article{Bung2013, author = {Bung, Daniel Bernhard}, title = {Non-intrusive detection of air-water surface roughness in self-aerated chute flows}, series = {Journal of hydraulic research}, volume = {Vol. 51}, journal = {Journal of hydraulic research}, number = {Iss. 3}, publisher = {Taylor \& Francis}, address = {London}, issn = {1814-2079 (E-Journal); 0022-1686 (Print)}, pages = {322 -- 329}, year = {2013}, language = {en} } @inproceedings{Bung2013, author = {Bung, Daniel Bernhard}, title = {Air-water surface roughness in self-aerated stepped spillway flows}, series = {35th IAHR world congress : 8.-13.9.2013, Chengdu, China}, booktitle = {35th IAHR world congress : 8.-13.9.2013, Chengdu, China}, publisher = {Tsinghua Univ. Press}, address = {Beijing}, organization = {International Association for Hydraulic Engineering and Research}, pages = {Artikelkennnummer: A11045}, year = {2013}, language = {en} } @inproceedings{BungPagliara2013, author = {Bung, Daniel Bernhard and Pagliara, S.}, title = {Proceedings of the International Workshop on Hydraulic Design of Low-Head Structures : Aachen, Germany, February, 20-22, 2013 / D. Bung ; S. Pagliara (eds.)}, publisher = {Bundesanst. f{\"u}r Wasserbau}, address = {Karlsruhe}, isbn = {978-3-939230-04-5}, pages = {X, 230 S. + 1 CD-ROM}, year = {2013}, language = {en} } @article{BuniatyanHuckPoghossianetal.2013, author = {Buniatyan, V. and Huck, Christina and Poghossian, Arshak and Aroutiounian, V. M. and Sch{\"o}ning, Michael Josef}, title = {BaxSr1-x TiO3/pc-Si heterojunction}, series = {Armenian journal of physics}, volume = {6}, journal = {Armenian journal of physics}, number = {4}, publisher = {National Academy of Sciences of Armenia}, address = {Yerevan}, issn = {1829-1171}, pages = {177 -- 187}, year = {2013}, language = {en} } @article{BuniatyanHuckPoghossianetal.2013, author = {Buniatyan, V. and Huck, Christina and Poghossian, Arshak and Aroutiounian, V. M. and Sch{\"o}ning, Michael Josef}, title = {BaxSr1-x TiO3/pc-Si heterojunction capacitance}, series = {Armenian journal of physics}, volume = {6}, journal = {Armenian journal of physics}, number = {4}, publisher = {National Academy of Sciences of Armenia}, address = {Yerevan}, issn = {1829-1171}, pages = {188 -- 197}, year = {2013}, language = {en} } @article{ButenwegGellert2013, author = {Butenweg, Christoph and Gellert, Christoph}, title = {Nichtlinearer Nachweis von Mauerwerksbauten}, series = {Mauerwerk : European journal of masonry}, volume = {Volume 17}, journal = {Mauerwerk : European journal of masonry}, number = {Issue 3}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1022 (E-Journal); 1432-3427 (Print)}, doi = {10.1002/dama.201300575}, pages = {166 -- 171}, year = {2013}, language = {de} } @inproceedings{ButenwegKleemannAltay2013, author = {Butenweg, Christoph and Kleemann, Anne and Altay, Okyay}, title = {Simulation von Impact Belastungen auf Stahlbetonstrukturen}, series = {13. D-A-CH Tagung f{\"u}r Erdbebeningenieurwesen und Baudynamik (D-A-CH 2013) : 29.-30. August 2013, Wien, {\"O}sterreich}, booktitle = {13. D-A-CH Tagung f{\"u}r Erdbebeningenieurwesen und Baudynamik (D-A-CH 2013) : 29.-30. August 2013, Wien, {\"O}sterreich}, organization = {D-A-CH Tagung f{\"u}r Erdbebeningenieurwesen und Baudynamik <13, 2013, Wien>}, pages = {1 -- 9}, year = {2013}, language = {de} } @article{ButenwegKleemannIkier2013, author = {Butenweg, Christoph and Kleemann, Anne and Ikier, Axel}, title = {Impact-Belastungen von Stahlbetonkonstruktionen}, series = {Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen ; offizielle Zeitschrift der VDI-Gesellschaft Bautechnik. Beilage: D-A-CH-Mitteilungsblatt}, volume = {Band 88}, journal = {Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen ; offizielle Zeitschrift der VDI-Gesellschaft Bautechnik. Beilage: D-A-CH-Mitteilungsblatt}, publisher = {VDI Verlag}, address = {D{\"u}sseldorf}, issn = {0005-6650}, pages = {S7 -- S14}, year = {2013}, language = {de} } @inproceedings{ButenwegNorda2013, author = {Butenweg, Christoph and Norda, Hannah}, title = {Nonlinear analysis of masonry structures according to Eurocode 8}, series = {Proceedings - Vienna Congress on Recent Advances in Earthquake Engineering and Structural Dynamics 2013 (VEESD 2013)}, booktitle = {Proceedings - Vienna Congress on Recent Advances in Earthquake Engineering and Structural Dynamics 2013 (VEESD 2013)}, editor = {Adam, Christoph and Heuer, Rudolf and Lenhardt, Wolfgang and Schranz, Christian}, isbn = {978-3-902749-04-8}, year = {2013}, language = {en} } @article{BaeckerRakowskiPoghossianetal.2013, author = {B{\"a}cker, Matthias and Rakowski, D. and Poghossian, Arshak and Biselli, Manfred and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Chip-based amperometric enzyme sensor system for monitoring of bioprocesses by flow-injection analysis}, series = {Journal of Biotechnology}, volume = {163}, journal = {Journal of Biotechnology}, number = {4}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0168-1656}, doi = {10.1016/j.jbiotec.2012.03.014}, pages = {371 -- 376}, year = {2013}, abstract = {A microfluidic chip integrating amperometric enzyme sensors for the detection of glucose, glutamate and glutamine in cell-culture fermentation processes has been developed. The enzymes glucose oxidase, glutamate oxidase and glutaminase were immobilized by means of cross-linking with glutaraldehyde on platinum thin-film electrodes integrated within a microfluidic channel. The biosensor chip was coupled to a flow-injection analysis system for electrochemical characterization of the sensors. The sensors have been characterized in terms of sensitivity, linear working range and detection limit. The sensitivity evaluated from the respective peak areas was 1.47, 3.68 and 0.28 μAs/mM for the glucose, glutamate and glutamine sensor, respectively. The calibration curves were linear up to a concentration of 20 mM glucose and glutamine and up to 10 mM for glutamate. The lower detection limit amounted to be 0.05 mM for the glucose and glutamate sensor, respectively, and 0.1 mM for the glutamine sensor. Experiments in cell-culture medium have demonstrated a good correlation between the glutamate, glutamine and glucose concentrations measured with the chip-based biosensors in a differential-mode and the commercially available instrumentation. The obtained results demonstrate the feasibility of the realized microfluidic biosensor chip for monitoring of bioprocesses.}, language = {en} }