@inproceedings{WuPoghossianWerneretal.2013, author = {Wu, Chunsheng and Poghossian, Arshak and Werner, Frederik and Bronder, Thomas and B{\"a}cker, Matthias and Wang, Ping and Sch{\"o}ning, Michael Josef}, title = {An application of a scanning light-addressable potentiometric sensor for label-free DNA detection}, series = {11. Dresdner Sensor-Symposium : 9.-11.12.2013}, booktitle = {11. Dresdner Sensor-Symposium : 9.-11.12.2013}, organization = {Dresdner Sensor-Symposium <11, 2013>}, isbn = {978-3-9813484-5-3}, pages = {164 -- 168}, year = {2013}, language = {en} } @article{WernerWagnerYoshinobuetal.2013, author = {Werner, Frederik and Wagner, Torsten and Yoshinobu, Tatsuo and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Frequency behaviour of light-addressable potentiometric sensors}, series = {Physica Status Solidi (A)}, volume = {210}, journal = {Physica Status Solidi (A)}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-396X ; 0031-8965}, doi = {10.1002/pssa.201200929}, pages = {884 -- 891}, year = {2013}, abstract = {Light-addressable potentiometric sensors (LAPS) are semiconductor-based potentiometric sensors, with the advantage to detect the concentration of a chemical species in a liquid solution above the sensor surface in a spatially resolved manner. The addressing is achieved by a modulated and focused light source illuminating the semiconductor and generating a concentration-depending photocurrent. This work introduces a LAPS set-up that is able to monitor the electrical impedance in addition to the photocurrent. The impedance spectra of a LAPS structure, with and without illumination, as well as the frequency behaviour of the LAPS measurement are investigated. The measurements are supported by electrical equivalent circuits to explain the impedance and the LAPS-frequency behaviour. The work investigates the influence of different parameters on the frequency behaviour of the LAPS. Furthermore, the phase shift of the photocurrent, the influence of the surface potential as well as the changes of the sensor impedance will be discussed.}, language = {en} } @article{WernerTakenagaTakietal.2013, author = {Werner, Frederik and Takenaga, Shoko and Taki, Hidenori and Sawada, Kazuaki and Sch{\"o}ning, Michael Josef}, title = {Comparison of label-free ACh-imaging sensors based on CCD and LAPS}, series = {Sensors and Actuators B: Chemical (2012)}, volume = {177}, journal = {Sensors and Actuators B: Chemical (2012)}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {0925-4005}, pages = {745 -- 752}, year = {2013}, abstract = {Semiconductor-based chemical imaging sensors, like the light-addressable potentiometric sensor (LAPS) or the pH-imaging sensor based on a charge-coupled device (CCD), are becoming a powerful tool for label-free imaging of biological phenomena. We have proposed a polyion-based enzymatic membrane to develop an acetylcholine (ACh) imaging sensor for neural cell-activity observations. In this study, a CCD-type ACh-imaging sensor and a LAPS-type ACh-imaging sensor were fabricated and the prospect of both sensors was clarified by making a comparison of their basic characteristics.}, language = {en} } @article{TranStaat2013, author = {Tran, Thanh Ngoc and Staat, Manfred}, title = {An Edge-Based Smoothed Finite Element Method for Primal-Dual Shakedown Analysis of Structures Under Uncertainties}, series = {Limit State of Materials and Structures : Direct Methods 2. Saxc{\´e}, G{\´e}ry de (Hrsg.)}, journal = {Limit State of Materials and Structures : Direct Methods 2. Saxc{\´e}, G{\´e}ry de (Hrsg.)}, publisher = {Springer}, address = {Dordrecht}, isbn = {978-94-007-5424-9}, pages = {89 -- 102}, year = {2013}, language = {en} } @article{Staat2013, author = {Staat, Manfred}, title = {Limit and shakedown analysis under uncertainty}, series = {International journal of computational methods : IJCM}, journal = {International journal of computational methods : IJCM}, publisher = {World Scientific Publishing}, address = {Singapore}, issn = {0219-8762}, pages = {Publ. online}, year = {2013}, language = {en} } @article{SchusserMenzelBaeckeretal.2013, author = {Schusser, Sebastian and Menzel, S. and B{\"a}cker, Matthias and Leinhos, Marcel and Poghossian, Arshak and Wagner, P. and Sch{\"o}ning, Michael Josef}, title = {Degradation of thin poly(lactic acid) films: characterization by capacitance-voltage, atomic force microscopy, scanning electron microscopy and contact-angle measurements}, series = {Electrochimica Acta}, volume = {Vol. 113}, journal = {Electrochimica Acta}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3859 (E-Journal); 0013-4686 (Print)}, pages = {779 -- 784}, year = {2013}, language = {en} } @article{SchusserLeinhosBaeckeretal.2013, author = {Schusser, Sebastian and Leinhos, Marcel and B{\"a}cker, Matthias and Poghossian, Arshak and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Impedance spectroscopy: A tool for real-time in situ monitoring of the degradation of biopolymers}, series = {Physica Status Solidi (A)}, volume = {210}, journal = {Physica Status Solidi (A)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1521-396X ; 0031-8965}, doi = {10.1002/pssa.201200941}, pages = {905 -- 910}, year = {2013}, abstract = {Investigation of the degradation kinetics of biodegradable polymers is essential for the development of implantable biomedical devices with predicted biodegradability. In this work, an impedimetric sensor has been applied for real-time and in situ monitoring of degradation processes of biopolymers. The sensor consists of two platinum thin-film electrodes covered by a polymer film to be studied. The benchmark biomedical polymer poly(D,L-lactic acid) (PDLLA) was used as a model system. PDLLA films were deposited on the sensor structure from a polymer solution by using the spin-coating method. The degradation kinetics of PDLLA films have been studied in alkaline solutions of pH 9 and 12 by means of an impedance spectroscopy (IS) method. Any changes in a polymer capacitance/resistance induced by water uptake and/or polymer degradation will modulate the global impedance of the polymer-covered sensor that can be used as an indicator of the polymer degradation. The degradation rate can be evaluated from the time-dependent impedance spectra. As expected, a faster degradation has been observed for PDLLA films exposed to pH 12 solution.}, language = {en} } @inproceedings{SchreiberHirtbachKraftetal.2013, author = {Schreiber, Marc and Hirtbach, Stefan and Kraft, Bodo and Steinmetzler, Andreas}, title = {Software in the city: visual guidance through large scale software projects}, series = {Software Engineering 2013 : Fachtagung des GI-Fachbereichs Softwaretechnik, 26. Februar-1. M{\"a}rz 2013 in Aachen. (GI-Edition ; 213)}, booktitle = {Software Engineering 2013 : Fachtagung des GI-Fachbereichs Softwaretechnik, 26. Februar-1. M{\"a}rz 2013 in Aachen. (GI-Edition ; 213)}, editor = {Kowalewski, Stefan}, publisher = {Ges. f{\"u}r Informatik}, address = {Bonn}, isbn = {978-3-88579-607-7 ; 978-3-88579-609-1}, pages = {213 -- 224}, year = {2013}, language = {en} } @inproceedings{SavitskayaKistaubayevaAkimbekovetal.2013, author = {Savitskaya, Irina S. and Kistaubayeva, Aida S. and Akimbekov, Nuraly S. and Digel, Ilya and Zhubanova, Azhar A.}, title = {Performance of Bio-Composite Carbonized Materials in Probiotic Applications}, series = {World Academy of Science, Engineering and Technology International Journal of Biotechnology and Bioengineering}, volume = {7}, booktitle = {World Academy of Science, Engineering and Technology International Journal of Biotechnology and Bioengineering}, number = {7}, pages = {685 -- 689}, year = {2013}, language = {en} } @article{ReisertSchneiderGeissleretal.2013, author = {Reisert, Steffen and Schneider, Benno and Geissler, Hanno and Gompel, Matthias van and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Multi-sensor chip for the investigation of different types of metal oxides for the detection of H2O2 in the ppm range}, series = {physica status solidi (a)}, volume = {210}, journal = {physica status solidi (a)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, pages = {898 -- 904}, year = {2013}, abstract = {In this work, a multi-sensor chip for the investigation of the sensing properties of different types of metal oxides towards hydrogen peroxide in the ppm range is presented. The fabrication process and physical characterization of the multi-sensor chip are described. Pure SnO2 and WO3 as well as Pd- and Pt-doped SnO2 films are characterized in terms of their sensitivity to H2O2. The sensing films have been prepared by drop-coating of water-dispensed nano-powders. A physical characterization, including scanning electron microscopy and X-ray diffraction analysis of the deposited metal-oxide films, was done. From the measurements in hydrogen peroxide atmosphere, it could be shown, that all of the tested metal oxide films are suitable for the detection of H2O2 in the ppm range. The highest sensitivity and reproducibility was achieved using Pt-doped SnO2. Calibration plot of a SnO2, WO3, Pt-, and Pd-doped SnO2 gas sensor for H2O2 concentrations in the ppm range.}, language = {en} }