@inproceedings{BassamDigelArtmann2009, author = {Bassam, Rasha and Digel, Ilya and Artmann, Gerhard}, title = {Effect of nitric oxide on protein thermal stability : [abstract]}, year = {2009}, abstract = {As a deduction from these results, we can conclude that proteins mainly in vitro, denaturate totally at a temperature between 57°C -62°C, and they also affected by NO and different ions types. In which mainly, NO cause earlier protein denaturation, which means that, NO has a destabilizing effect on proteins, and also different ions will alter the protein denaturation in which, some ions will cause earlier protein denaturation while others not.}, subject = {Stickstoffmonoxid}, language = {en} } @article{BassamArtmannHescheleretal.2011, author = {Bassam, Rasha and Artmann, Gerhard and Hescheler, J{\"u}rgen and Graef, T. and Temiz Artmann, Ayseg{\"u}l and Porst, Dariusz and Linder, Peter and Kayser, Peter and Arinkin, Vladimir and Gossmann, Matthias and Digel, Ilya}, title = {Alterations in human hemoglobin structure related to red blood cell storage}, year = {2011}, abstract = {The importance of the availability of stored blood or blood cells, respectively, for urgent transfusion cannot be overestimated. Nowadays, blood storage becomes even more important since blood products are used for epidemiological studies, bio-technical research or banked for transfusion purposes. Thus blood samples must not only be processed, stored, and shipped to preserve their efficacy and safety, but also all parameters of storage must be recorded and reported for Quality Assurance. Therefore, blood banks and clinical research facilities are seeking more accurate, automated means for blood storage and blood processing.}, subject = {H{\"a}moglobin}, language = {en} } @article{BaroudWuBohneretal.2003, author = {Baroud, G. and Wu, J.Z. and Bohner, M and Sponagel, Stefan and Steffen, T.}, title = {How to determine the permeability for cement infiltration into osteoporotic cancellous bone}, series = {Medical Engineering \& Physics. 25 (2003), H. 4}, journal = {Medical Engineering \& Physics. 25 (2003), H. 4}, issn = {1350-4533}, pages = {283 -- 288}, year = {2003}, abstract = {Cement augmentation is an emerging surgical procedure in which bone cement is used to infiltrate and reinforce osteoporotic vertebrae. Although this infiltration procedure has been widely applied, it is performed empirically and little is known about the flow characteristics of cement during the injection process. We present a theoretical and experimental approach to investigate the intertrabecular bone permeability during the infiltration procedure. The cement permeability was considered to be dependent on time, bone porosity, and cement viscosity in our analysis. In order to determine the time-dependent permeability, ten cancellous bone cores were harvested from osteoporotic vertebrae, infiltrated with acrylic cement at a constant flow rate, and the pressure drop across the cores during the infiltration was measured. The viscosity dependence of the permeability was determined based on published experimental data. The theoretical model for the permeability as a function of bone porosity and time was then fit to the testing data. Our findings suggest that the intertrabecular bone permeability depends strongly on time. For instance, the initial permeability (60.89 mm4/N.s) reduced to approximately 63\% of its original value within 18 seconds. This study is the first to analyze cement flow through osteoporotic bone. The theoretical and experimental models provided in this paper are generic. Thus, they can be used to systematically study and optimize the infiltration process for clinical practice.}, subject = {Osteoporose}, language = {en} } @inproceedings{BaronasIvanauskasKulys2006, author = {Baronas, Romas and Ivanauskas, Feliksas and Kulys, Juozas}, title = {Mathematical modeling of biosensors based on an array of enzyme microreactors}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1569}, year = {2006}, abstract = {This paper presents a two-dimensional-in-space mathematical model of biosensors based on an array of enzyme microreactors immobilised on a single electrode. The modeling system acts under amperometric conditions. The microreactors were modeled by particles and by strips. The model is based on the diffusion equations containing a nonlinear term related to the Michaelis-Menten kinetics of the enzymatic reaction. The model involves three regions: an array of enzyme microreactors where enzyme reaction as well as mass transport by diffusion takes place, a diffusion limiting region where only the diffusion takes place, and a convective region, where the analyte concentration is maintained constant. Using computer simulation, the influence of the geometry of the microreactors and of the diffusion region on the biosensor response was investigated. The digital simulation was carried out using the finite difference technique.}, subject = {Biosensor}, language = {en} } @inproceedings{BarekFischerNavratiletal.2006, author = {Barek, Jiri and Fischer, Jan and Navratil, Tomas and Peckova, Karolina and Yosypchuk, Bogdan}, title = {Silver solid amalgam electrodes as sensors for chemical carcinogens}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1554}, year = {2006}, abstract = {The applicability of differential pulse voltammetry (DPV) and adsorptive stripping voltammetry (AdSV) at a non-toxic meniscus-modified silver solid amalgam electrode (m-AgSAE) for the determination of trace amounts of genotoxic substances was demonstrated on the determination of micromolar and submicromolar concentrations of 3-nitrofluoranthene using methanol - 0.01 mol L-1 NaOH (9:1) mixture as a base electrolyte and of Ostazine Orange using 0.01 mol L-1 NaOH as a base electrolyte.}, subject = {Biosensor}, language = {en} } @inproceedings{BallmannRaatschenStaat1985, author = {Ballmann, J. and Raatschen, Hans-J{\"u}rgen and Staat, Manfred}, title = {High stress intensities in focussing zones of waves}, doi = {10.1016/B978-0-444-42520-1.50015-3}, year = {1985}, abstract = {The propagation of mechanical waves in plates of isotropic elastic material is investigated. After a short introduction to the understanding of focussing of stress waves in a plate with a curved boundary the method of characteristics is applied to a plate of hyperelastic material. Using this method the propagation of acceleration waves is discussed. Based on this a numerical difference scheme is developed for solving initial-boundary-value problems and applied to two examples: propagation of a point disturbance in a homogeneously finitely strained non-linear elastic plate and geometrical focussing in al linear elastic plate.}, subject = {Technische Mechanik}, language = {en} } @inproceedings{ArtmannStadlerEmbsetal.2010, author = {Artmann, Gerhard and Stadler, Andreas M. and Embs, Jan P. and Zaccai, Giuseppe and B{\"u}ldt, Georg and Digel, Ilya and Temiz Artmann, Ayseg{\"u}l}, title = {The crucial role of water in a phase transition of hemoglobin at body temperature : [abstract]}, year = {2010}, abstract = {The observation of a temperature transition of hemoglobin occurring at a critical temperature close to body temperature}, subject = {H{\"a}moglobin}, language = {en} } @inproceedings{ArtmannDigelLinderetal.2011, author = {Artmann, Gerhard and Digel, Ilya and Linder, Peter and Temiz Artmann, Ayseg{\"u}l}, title = {Biophysical and Engineering Contributions to Plant Research}, year = {2011}, abstract = {Tests with palm tree leaves have just started yet and scan data are in the process to be analyzed. The final goal of future project for palm tree gender and species recognition will be to develop optical scanning technology to be applied to date palm tree leaves for in-situ screening purposes. Depending on the software used and the particular requirements of the users the technology potentially shall be able to identify palm tree diseases, palm tree gender, and species of young date palm trees by scanning leaves.}, subject = {Pflanzenphysiologie}, language = {en} } @inproceedings{ArinkinDigel2009, author = {Arinkin, Vladimir and Digel, Ilya}, title = {Water bridge phenomenon : [abstract]}, year = {2009}, abstract = {One of interesting but not well known water properties is related to appearance of highly ordered structures in response to strong electrical field. In 1893 Sir William Armstrong placed a cotton thread between two wine glasses filled with chemically pure water. When high DC voltage was applied between the glasses, a connection consisting of water formed, producing a "water bridge"}, subject = {Hydrodynamik}, language = {en} } @inproceedings{AridaKloockSchoening2006, author = {Arida, Hassan A. and Kloock, Joachim P. and Sch{\"o}ning, Michael Josef}, title = {Novel organic membrane-based thin-film microsensors for the determination of heavy metal cations}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1545}, year = {2006}, abstract = {A first step towards the fabrication and electrochemical evaluation of thin-film microsensors based on organic PVC membranes for the determination of Hg(II), Cd(II), Pb(II) and Cu(II) ions in solutions has been realised. The membrane-coating mixture used in the preparation of this new type of microsensors is incorporating PVC as supporting matrix, o-nitrophenyloctylether (o-NPOE) as solvent mediator and a recently synthesized Hg[dimethylglyoxime(phene)]2+ and Bis-(4-hydroxyacetophenone)-ethylenediamine as electroactive materials for Hg(II) and Cd(II), respectively. A set of three commercialised ionophores for Cd(II), Pb(II) and Cu(II) has been also used for comparison. Thin-film microsensors based on these membranes showed a Nernstian response of slope (26-30 mV/dec.) for the respective tested cations. The potentiometric response characteristics (linear range, pH range, detection limit and response time) are comparable with those obtained by conventional membranes as well as coated wire electrodes prepared from the same membrane. The realisation of the new organic membrane-based thin-film microsensors overcomes the problem of an insufficient selectivity of solid-state-based thinfilm sensors.}, subject = {Biosensor}, language = {en} }