@inproceedings{DuemmlerOetringerGoettsche2020, author = {D{\"u}mmler, Andreas and Oetringer, Kerstin and G{\"o}ttsche, Joachim}, title = {Auslegungstool zur energieeffizienten K{\"u}hlung von Geb{\"a}uden}, series = {DKV-Tagung 2020, AA IV}, booktitle = {DKV-Tagung 2020, AA IV}, pages = {1 -- 12}, year = {2020}, language = {de} } @inproceedings{KubalskiButenweg2015, author = {Kubalski, T. and Butenweg, Christoph}, title = {Ausfachungsmauerwerk unter kombinierter seismischer Beanspruchung}, series = {Erdbeben und bestehende Bauten : 14. D-A-C-H Tagung 20.08. - 21.08.2015, ETH Z{\"u}rich. (Dokumentation / SIA ; D 0255)}, booktitle = {Erdbeben und bestehende Bauten : 14. D-A-C-H Tagung 20.08. - 21.08.2015, ETH Z{\"u}rich. (Dokumentation / SIA ; D 0255)}, publisher = {SGEB}, address = {Z{\"u}rich}, organization = {D-A-C-H Tagung <14, 2015, Z{\"u}rich>}, isbn = {978-3-03732-060-0}, pages = {117 -- 122}, year = {2015}, language = {de} } @inproceedings{DoerenWernicke1983, author = {D{\"o}ren, Horst-Peter and Wernicke, K.}, title = {Auftragen von verschleißfesten stranggegossenen Hartlegierungen auf Kobaltbasis durch das WIG- und Gasschweißen}, series = {Schweißen und Schneiden '83 = Welding and Cutting '83. Vortr{\"a}ge der Großen Schweißtechnischen Tagung in Aachen vom 28. bis 30. September 1983. Veranst.: Deutscher Verband f{\"u}r Schweißtechnik (DVS). DVS-Berichte. 83}, booktitle = {Schweißen und Schneiden '83 = Welding and Cutting '83. Vortr{\"a}ge der Großen Schweißtechnischen Tagung in Aachen vom 28. bis 30. September 1983. Veranst.: Deutscher Verband f{\"u}r Schweißtechnik (DVS). DVS-Berichte. 83}, publisher = {Dt. Verl. f{\"u}r Schweißtechnik}, address = {D{\"u}sseldorf}, issn = {3-87155-388-3}, pages = {109 -- 113}, year = {1983}, language = {de} } @inproceedings{ZischankKernFrentzeletal.2000, author = {Zischank, Wolfgang J. and Kern, Alexander and Frentzel, Ralf and Heidler, Fridolin and Seevers, M.}, title = {Assessment of the lightning transient coupling to control cables interconnecting structures in large industrial facilities and power plants}, year = {2000}, abstract = {Large industrial facilities and power plants often require a huge number fo information and control cables between the differnet structures. These I\&C-cables can be routed in reinforced concrete cable ducts or in isolated buried cable runs. KTA 2206 is the German lightning protection standard for nuclear power plants. During the last several years considerable effort has been made to revise this standard. Despite the well established principles and design guidelines for the construction of the lightning protection system, this standard puts special emphasis on the coupling of transient overvoltages to I\&C-cables.}, language = {en} } @inproceedings{HellmannsFischerDilgeretal.2014, author = {Hellmanns, Mark and Fischer, F. and Dilger, K. and Wittor, B. and Hildebrand, J. and Werner, F.}, title = {Applikation und Einsatz von faserverst{\"a}rkten Klebstoffen im Bauwesen abgeschlossenes IGF-Projekt Nr. 16956 B (DVS 08.072, Laufzeit 01.02.2011 - 31.01.2013)}, series = {Tagungsband / 14. Kolloquium Gemeinsame Forschung in der Klebtechnik : 18. und 19. Februar 2014, DECHEMA-Haus, Frankfurt am Main}, booktitle = {Tagungsband / 14. Kolloquium Gemeinsame Forschung in der Klebtechnik : 18. und 19. Februar 2014, DECHEMA-Haus, Frankfurt am Main}, organization = {DECHEMA, Gesellschaft f{\"u}r Chemische Technik und Biotechnologie}, pages = {26 -- 27}, year = {2014}, language = {de} } @inproceedings{HellmannsFischerDilger2013, author = {Hellmanns, Mark and Fischer, F. and Dilger, Klaus}, title = {Applikation und Einsatz von faserverst{\"a}rkten Klebstoffen im Bauwesen}, series = {Tagungsband / 13. Kolloquium Gemeinsame Forschung in der Klebtechnik : 26. und 27. Februar 2013, Frankfurt am Main}, booktitle = {Tagungsband / 13. Kolloquium Gemeinsame Forschung in der Klebtechnik : 26. und 27. Februar 2013, Frankfurt am Main}, publisher = {DECHEMA}, address = {Frankfurt a.M.}, organization = {DECHEMA, Gesellschaft f{\"u}r Chemische Technik und Biotechnologie}, pages = {61 -- 62}, year = {2013}, language = {de} } @inproceedings{DarvenizaFlisowskiKernetal.2002, author = {Darveniza, M. and Flisowski, Z. and Kern, Alexander and Landers, E.-U. and LoPiparo, G. and Mazzetti, C. and Rousseau, A. and Sherlock, J.}, title = {Application problems of the probabilistic approach to the assessment of risk for structures and services}, year = {2002}, abstract = {The paper deals with the development of the probabilistic approach to the assessment of risk due to lightning. Sources of damage, types of damage and types of loss are defined and, accordingly, the procedure for risk analysis and the way of assessment of different risk components is proposed. The way to evaluate the influence of different protection measures (lightning protection system; shielding of structure, cables and equipment; routing of internal wiring; surge protective device) in reducing such probabilities is considered. The paper has been prepared within the framework of the activity of IEC TC81-WG9/CLC TC81-WG4 directed to prepare the draft IEC 62305-2 Risk Management, in cooperation with the Secretary of IEC/CLC TC81.}, language = {en} } @inproceedings{BreitbachAlexopoulosMayetal.2019, author = {Breitbach, Gerd and Alexopoulos, Spiros and May, Martin and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf}, title = {Analysis of volumetric solar radiation absorbers made of wire meshes}, series = {AIP Conference Proceedings}, volume = {2126}, booktitle = {AIP Conference Proceedings}, issn = {0094243X}, doi = {10.1063/1.5117521}, pages = {030009-1 -- 030009-6}, year = {2019}, language = {en} } @inproceedings{RosinMykoniouButenweg2017, author = {Rosin, J. and Mykoniou, K. and Butenweg, Christoph}, title = {Analysis Of Base Isolated Liquid Storage Tanks With 3D Fsi-Analysis As Well As Simplified Approaches}, series = {16th World Conference on Earthquake Engineering, 16WCEE 2017 Santiago Chile, January 9th to 13th 2017}, booktitle = {16th World Conference on Earthquake Engineering, 16WCEE 2017 Santiago Chile, January 9th to 13th 2017}, publisher = {Chilean Association on Seismology and Earthquake Engineering (ACHISINA)}, pages = {1 -- 14}, year = {2017}, abstract = {Tanks are preferably designed, for cost-saving reasons, as circular, cylindrical, thin-walled shells. In case of seismic excitation, these constructions are highly vulnerable to stability failures. An earthquake-resistant design of rigidly supported tanks for high seismic loading demands, however, uneconomic wall thicknesses. A cost-effective alternative can be provided by base isolation systems. In this paper, a simplified seismic design procedure for base isolated tanks is introduced, by appropriately modifying the standard mechanical model for flexible, rigidly supported tanks. The non-linear behavior of conventional base isolation systems becomes an integral part of a proposed simplified process, which enables the assessment of the reduced hydrodynamic forces acting on the tank walls and the corresponding stress distribution. The impulsive and convective actions of the liquid are taken into account. The validity of this approach is evaluated by employing a non-linear fluid-structure interaction algorithm of finite element method. Special focus is placed on the boundary conditions imposed from the base isolation and the resulting hydrodynamic pressures. Both horizontal and vertical component of ground motion are considered in order to study the principal effects of the base isolation on the pressure distribution of the tank walls. The induced rocking effects associated with elastomeric bearings are discussed. The results manifest that base isolated tanks can be designed for seismic loads by means of the proposed procedure with sufficient accuracy, allowing to dispense with numerically expensive techniques.}, language = {en} } @inproceedings{GedleSchmitzGielenetal.2022, author = {Gedle, Yibekal and Schmitz, Mark and Gielen, Hans and Schmitz, Pascal and Herrmann, Ulf and Teixeira Boura, Cristiano Jos{\´e} and Mahdi, Zahra and Caminos, Ricardo Alexander Chico and Dersch, J{\"u}rgen}, title = {Analysis of an integrated CSP-PV hybrid power plant}, series = {SolarPACES 2020}, booktitle = {SolarPACES 2020}, number = {2445 / 1}, publisher = {AIP conference proceedings / American Institute of Physics}, address = {Melville, NY}, isbn = {978-0-7354-4195-8}, issn = {1551-7616 (online)}, doi = {10.1063/5.0086236}, pages = {9 Seiten}, year = {2022}, abstract = {In the past, CSP and PV have been seen as competing technologies. Despite massive reductions in the electricity generation costs of CSP plants, PV power generation is - at least during sunshine hours - significantly cheaper. If electricity is required not only during the daytime, but around the clock, CSP with its inherent thermal energy storage gets an advantage in terms of LEC. There are a few examples of projects in which CSP plants and PV plants have been co-located, meaning that they feed into the same grid connection point and ideally optimize their operation strategy to yield an overall benefit. In the past eight years, TSK Flagsol has developed a plant concept, which merges both solar technologies into one highly Integrated CSP-PV-Hybrid (ICPH) power plant. Here, unlike in simply co-located concepts, as analyzed e.g. in [1] - [4], excess PV power that would have to be dumped is used in electric molten salt heaters to increase the storage temperature, improving storage and conversion efficiency. The authors demonstrate the electricity cost sensitivity to subsystem sizing for various market scenarios, and compare the resulting optimized ICPH plants with co-located hybrid plants. Independent of the three feed-in tariffs that have been assumed, the ICPH plant shows an electricity cost advantage of almost 20\% while maintaining a high degree of flexibility in power dispatch as it is characteristic for CSP power plants. As all components of such an innovative concept are well proven, the system is ready for commercial market implementation. A first project is already contracted and in early engineering execution.}, language = {en} }