@article{Timme2014, author = {Timme, Michael}, title = {BGH: Geltendmachung von Sachm{\"a}ngeln bei Wohnungseigentum}, series = {LMK : Fachdienst Zivilrecht : Kommentierte BGH-Rechtsprechung}, volume = {2014}, journal = {LMK : Fachdienst Zivilrecht : Kommentierte BGH-Rechtsprechung}, number = {5}, publisher = {Beck}, address = {M{\"u}nchen}, issn = {1611-1095}, year = {2014}, language = {de} } @incollection{Timme2014, author = {Timme, Michael}, title = {Begriffsbestimmungen}, series = {Wohnungseigentumsgesetz : Gesetz {\"u}ber das Wohnungseigentum und das Dauerwohnrecht ; Kommentar}, booktitle = {Wohnungseigentumsgesetz : Gesetz {\"u}ber das Wohnungseigentum und das Dauerwohnrecht ; Kommentar}, edition = {2. Auflage}, publisher = {Beck}, address = {M{\"u}nchen}, isbn = {978-3-406-66025-2}, pages = {1 -- 23}, year = {2014}, language = {de} } @article{FiedlerHennMelcher2014, author = {Fiedler, Gerda and Henn, Gudrun and Melcher, Karin}, title = {ANPAK - ein semesterbegleitender Anpassungskurs}, series = {Zeitschrift f{\"u}r Hochschulentwicklung}, volume = {9}, journal = {Zeitschrift f{\"u}r Hochschulentwicklung}, number = {4}, publisher = {{\"O}GHD}, address = {Wien}, issn = {2219-6994}, pages = {85 -- 100}, year = {2014}, abstract = {In Folge mehrj{\"a}hriger statistischer Untersuchungen an der FH Aachen ist unter anderem ein Eingangstest entstanden, der als Diagnosetool f{\"u}r einen erfolgreichen Studieneinstieg verwendet wird. Es hat sich herausgestellt, dass ein Testergebnis von weniger als 25 (von maximal 56 erreichbaren) Punkten die Chance auf einen erfolgreichen Studieneinstieg deutlich verringert. Ungef{\"a}hr die H{\"a}lfte aller Erstsemester hat weniger als 25 Punkte im Eingangstest. Weniger als 20 \% dieser Gruppe bestehen innerhalb eines Jahres die Klausur Mathematik 1. Die investierte Zeit von zwei Semestern ist mit Blick auf den Wissenszuwachs und damit letztendlich den Studienerfolg nicht effizient genutzt. Deshalb haben wir im WS 2013/14 einen semesterbegleitenden Anpassungskurs f{\"u}r diese Gruppe installiert. Ziel eines solchen Kurses ist es, die Student/innen innerhalb eines Jahres in die Lage zu versetzen, nach zwei Semestern problemlos den Vorlesungen in Mathematik zu folgen. Dieser Artikel beschreibt das Konzept dieses Anpassungskurses und zeigt erste Ergebnisse und Probleme des Pilotdurchgangs auf.}, language = {de} } @incollection{KirchnerReisertSchoening2014, author = {Kirchner, Patrick and Reisert, Steffen and Sch{\"o}ning, Michael Josef}, title = {Calorimetric gas sensors for hydrogen peroxide monitoring in aseptic food processes}, series = {Gas sensing fundamentals. (Springer Series on Chemical Sensors and Biosensors ; 15)}, booktitle = {Gas sensing fundamentals. (Springer Series on Chemical Sensors and Biosensors ; 15)}, publisher = {Springer}, address = {Heidelberg}, isbn = {978-3-642-54518-4 (Print) ; 978-3-642-54519-1 (Online)}, doi = {10.1007/5346_2013_51}, pages = {279 -- 309}, year = {2014}, abstract = {For the sterilisation of aseptic food packages it is taken advantage of the microbicidal properties of hydrogen peroxide (H2O2). Especially, when applied in vapour phase, it has shown high potential of microbial inactivation. In addition, it offers a high environmental compatibility compared to other chemical sterilisation agents, as it decomposes into oxygen and water, respectively. Due to a lack in sensory detection possibilities, a continuous monitoring of the H2O2 concentration was recently not available. Instead, the sterilisation efficacy is validated using microbiological tests. However, progresses in the development of calorimetric gas sensors during the last 7 years have made it possible to monitor the H2O2 concentration during operation. This chapter deals with the fundamentals of calorimetric gas sensing with special focus on the detection of gaseous hydrogen peroxide. A sensor principle based on a calorimetric differential set-up is described. Special emphasis is given to the sensor design with respect to the operational requirements under field conditions. The state-of-the-art regarding a sensor set-up for the on-line monitoring and secondly, a miniaturised sensor for in-line monitoring are summarised. Furthermore, alternative detection methods and a novel multi-sensor system for the characterisation of aseptic sterilisation processes are described.}, language = {en} } @incollection{SchoeningPoghossianGluecketal.2014, author = {Sch{\"o}ning, Michael Josef and Poghossian, Arshak and Gl{\"u}ck, Olaf and Thust, Marion}, title = {Electrochemical methods for the determination of chemical variables in aqueous media}, series = {Measurement, instrumentation, and sensors handbook / ed. by John G. Webster [u.a.] Vol. 2 : Electromagnetic, optical, radiation, chemical, and biomedical measurement}, booktitle = {Measurement, instrumentation, and sensors handbook / ed. by John G. Webster [u.a.] Vol. 2 : Electromagnetic, optical, radiation, chemical, and biomedical measurement}, publisher = {CRC Pr.}, address = {Boca Raton, Fla.}, isbn = {978-1-4398-4891-3}, pages = {55-1 -- 55-54}, year = {2014}, language = {en} } @article{NachtrodtTietschMostaccietal.2014, author = {Nachtrodt, Frederik and Tietsch, Wolfgang and Mostacci, Domiziano and Scherer, Ulrich W.}, title = {Set-up and first operation of a plasma oven for treatment of low level radioactive wastes}, series = {Nuclear technology and radiation protection}, volume = {29}, journal = {Nuclear technology and radiation protection}, number = {Suppl.}, publisher = {VINČA Institute of Nuclear Sciences}, address = {Belgrad}, issn = {1451-3994}, doi = {10.2298/NTRP140SS47N}, pages = {47 -- 51}, year = {2014}, language = {en} } @article{FateriGebhardtThuemmleretal.2014, author = {Fateri, Miranda and Gebhardt, Andreas and Th{\"u}mmler, Stefan and Thurn, Laura}, title = {Experimental investigation on selective laser melting of glass}, series = {Physics procedia : 8th International Conference on Laser Assisted Net Shape Engineering LANE 2014}, volume = {56 (2014)}, journal = {Physics procedia : 8th International Conference on Laser Assisted Net Shape Engineering LANE 2014}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1875-3892 (E-Journal); 1875-3884 (Print)}, doi = {10.1016/j.phpro.2014.08.118}, pages = {357 -- 364}, year = {2014}, language = {en} } @article{SrivastavaLahiriMaitietal.2014, author = {Srivastava, A. and Lahiri, S. and Maiti, M. and Knolle, F. and Hoyler, Friedrich and Scherer, Ulrich W. and Schnug, E. W.}, title = {Study of naturally occurring radioactive material (NORM) in top soil of Punjab State from the North Western part of India}, series = {Journal of Radioanalytical and Nuclear Chemistry}, volume = {2014}, journal = {Journal of Radioanalytical and Nuclear Chemistry}, number = {302}, publisher = {Springer Nature}, address = {Basel}, issn = {1588-2780 (E-Journal); 0022-4081 (Print); 0134-0719 (Print); 0236-5731 (Print); 1417-2097 (Print)}, doi = {0.1007/s10967-014-3450-1}, pages = {1049 -- 1052}, year = {2014}, language = {en} } @article{SiqueiraMolinnusBegingetal.2014, author = {Siqueira, Jose R. and Molinnus, Denise and Beging, Stefan and Sch{\"o}ning, Michael Josef}, title = {Incorporating a hybrid urease-carbon nanotubes sensitive nanofilm on capacitive field-effect sensors for urea detection}, series = {Analytical chemistry}, volume = {86}, journal = {Analytical chemistry}, number = {11}, publisher = {ACS Publications}, address = {Columbus}, issn = {1520-6882 (E-Journal); 0003-2700 (Print); 0096-4484 (Print)}, doi = {10.1021/ac500458s}, pages = {5370 -- 5375}, year = {2014}, abstract = {The ideal combination among biomolecules and nanomaterials is the key for reaching biosensing units with high sensitivity. The challenge, however, is to find out a stable and sensitive film architecture that can be incorporated on the sensor's surface. In this paper, we report on the benefits of incorporating a layer-by-layer (LbL) nanofilm of polyamidoamine (PAMAM) dendrimer and carbon nanotubes (CNTs) on capacitive electrolyte-insulator-semiconductor (EIS) field-effect sensors for detecting urea. Three sensor arrangements were studied in order to investigate the adequate film architecture, involving the LbL film with the enzyme urease: (i) urease immobilized directly onto a bare EIS [EIS-urease] sensor; (ii) urease atop the LbL film over the EIS [EIS-(PAMAM/CNT)-urease] sensor; and (iii) urease sandwiched between the LbL film and another CNT layer [EIS-(PAMAM/CNT)-urease-CNT]. The surface morphology of all three urea-based EIS biosensors was investigated by atomic force microscopy (AFM), while the biosensing abilities were studied by means of capacitance-voltage (C/V) and dynamic constant-capacitance (ConCap) measureaments at urea concentrations ranging from 0.1 mM to 100 mM. The EIS-urease and EIS-(PAMAM/CNT)-urease sensors showed similar sensitivity (∼18 mV/decade) and a nonregular signal behavior as the urea concentration increased. On the other hand, the EIS-(PAMAM/CNT)-urease-CNT sensor exhibited a superior output signal performance and higher sensitivity of about 33 mV/decade. The presence of the additional CNT layer was decisive to achieve a urea based EIS sensor with enhanced properties. Such sensitive architecture demonstrates that the incorporation of an adequate hybrid enzyme-nanofilm as sensing unit opens new prospects for biosensing applications using the field-effect sensor platform.}, language = {en} } @article{MuribYeapMartensetal.2014, author = {Murib, Mohammed Sharif and Yeap, Weng-Siang and Martens, Daan and Bienstman, Peter and Ceuninck, Ward de and Grinsven, Bart van and Sch{\"o}ning, Michael Josef and Michiels, Luc and Haenen, Ken and Ameloot, Marcel and Serpeng{\"u}zel, Ali and Wagner, Patrick}, title = {Photonic detection and characterization of DNA using sapphire microspheres}, series = {Journal of biomedical optics}, volume = {19}, journal = {Journal of biomedical optics}, number = {9}, publisher = {SPIE}, address = {Bellingham}, issn = {1560-2281 (E-Journal); 1083-3668 (Print)}, doi = {10.1117/1.JBO.19.9.097006}, pages = {097006}, year = {2014}, abstract = {A microcavity-based deoxyribonucleic acid (DNA) optical biosensor is demonstrated for the first time using synthetic sapphire for the optical cavity. Transmitted and elastic scattering intensity at 1510 nm are analyzed from a sapphire microsphere (radius 500  μm, refractive index 1.77) on an optical fiber half coupler. The 0.43 nm angular mode spacing of the resonances correlates well with the optical size of the sapphire sphere. Probe DNA consisting of a 36-mer fragment was covalently immobilized on a sapphire microsphere and hybridized with a 29-mer target DNA. Whispering gallery modes (WGMs) were monitored before the sapphire was functionalized with DNA and after it was functionalized with single-stranded DNA (ssDNA) and double-stranded DNA (dsDNA). The shift in WGMs from the surface modification with DNA was measured and correlated well with the estimated thickness of the add-on DNA layer. It is shown that ssDNA is more uniformly oriented on the sapphire surface than dsDNA. In addition, it is shown that functionalization of the sapphire spherical surface with DNA does not affect the quality factor (Q≈104) of the sapphire microspheres. The use of sapphire is especially interesting because this material is chemically resilient, biocompatible, and widely used for medical implants.}, language = {en} }