@article{AltayButenwegTaddei2013, author = {Altay, Okyay and Butenweg, Christoph and Taddei, Francesca}, title = {Effektivit{\"a}t von Schwingungsd{\"a}mpfern bei Windenergieanlagen}, series = {Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen ; offizielle Zeitschrift der VDI-Gesellschaft Bautechnik. Beilage: D-A-CH-Mitteilungsblatt}, volume = {Band 88}, journal = {Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen ; offizielle Zeitschrift der VDI-Gesellschaft Bautechnik. Beilage: D-A-CH-Mitteilungsblatt}, number = {Heft 10}, publisher = {VDI Fachmedien}, address = {D{\"u}sseldorf}, issn = {1436-4867 (E-Journal); 0005-6650 (Print)}, pages = {S11 -- S17}, year = {2013}, language = {de} } @article{BaumgartnerFidlerWethetal.2008, author = {Baumgartner, Werner and Fidler, Florian and Weth, Agnes and Habbecke, Martin and Jakob, Peter and Butenweg, Christoph and B{\"o}hme, Wolfgang}, title = {Investigating the locomotion of the sandfish in desert sand using NMR-Imaging}, series = {PLOS ONE}, volume = {3}, journal = {PLOS ONE}, number = {10}, publisher = {Plos}, address = {San Francisco, California, US}, issn = {1932-6203}, doi = {10.1371/journal.pone.0003309}, pages = {e3309}, year = {2008}, abstract = {The sandfish (Scincus scincus) is a lizard having the remarkable ability to move through desert sand for significant distances. It is well adapted to living in loose sand by virtue of a combination of morphological and behavioural specializations. We investigated the bodyform of the sandfish using 3D-laserscanning and explored its locomotion in loose desert sand using fast nuclear magnetic resonance (NMR) imaging. The sandfish exhibits an in-plane meandering motion with a frequency of about 3 Hz and an amplitude of about half its body length accompanied by swimming-like (or trotting) movements of its limbs. No torsion of the body was observed, a movement required for a digging-behaviour. Simple calculations based on the Janssen model for granular material related to our findings on bodyform and locomotor behaviour render a local decompaction of the sand surrounding the moving sandfish very likely. Thus the sand locally behaves as a viscous fluid and not as a solid material. In this fluidised sand the sandfish is able to "swim" using its limbs.}, language = {en} } @article{BeckerFrauenrathHezeletal.2010, author = {Becker, Meike and Frauenrath, Tobias and Hezel, Fabian and Krombach, Gabriele A. and Kremer, Ute and Koppers, Benedikt and Butenweg, Christoph and Goemmel, Andreas and Utting, Jane F. and Schulz-Menger, Jeanette and Niendorf, Thoralf}, title = {Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T}, series = {European Radiology}, volume = {20}, journal = {European Radiology}, publisher = {Springer}, address = {Berlin}, issn = {1432-1084 (Onlineausgabe)}, doi = {10.1007/s00330-009-1676-z}, pages = {1344 -- 1355}, year = {2010}, abstract = {Objective: As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n=14). Methods: Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT's performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Results: Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct Rwave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects—even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), endsystolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived fromVCG-triggered acquisitions (1.5 T: ESVVCG=(56± 17) ml, EDVVCG=(151±32)ml, LVMVCG=(97±27) g, SVVCG=(94± 19)ml, EFVCG=(63±5)\% cf. ESVACT= (56±18) ml, EDVACT=(147±36) ml, LVMACT=(102±29) g, SVACT=(91± 22) ml, EFACT=(62±6)\%; 3.0 T: ESVVCG=(55±21) ml, EDVVCG=(151±32) ml, LVMVCG=(101±27) g, SVVCG=(96±15) ml, EFVCG=(65±7)\% cf. ESVACT=(54±20) ml, EDVACT=(146±35) ml, LVMACT= (101±30) g, SVACT=(92±17) ml, EFACT=(64±6)\%). Conclusions: ACT's intrinsic insensitivity to interference from electromagnetic fields renders}, language = {en} } @article{Butenweg2017, author = {Butenweg, Christoph}, title = {Die neue Erdbebenfibel. Neue Hilfsmittel f{\"u}r die Leichtbetonindustrie}, series = {Tagungsband 61. Ulmer Beton Tage 2017}, journal = {Tagungsband 61. Ulmer Beton Tage 2017}, year = {2017}, language = {de} } @article{Butenweg2010, author = {Butenweg, Christoph}, title = {Bewertung der Erdbebensicherheit von bestehenden Bauwerken}, series = {{\"O}sterreichische Ingenieur- und Architekten-Zeitschrift : {\"O}IAZ ; Zeitschr. d. {\"O}IAV / {\"O}sterreichischer Ingenieur- und Architekten-Verein}, volume = {155}, journal = {{\"O}sterreichische Ingenieur- und Architekten-Zeitschrift : {\"O}IAZ ; Zeitschr. d. {\"O}IAV / {\"O}sterreichischer Ingenieur- und Architekten-Verein}, number = {1-3 und 4-6}, publisher = {{\"O}AIV}, address = {Wien}, issn = {0721-9415}, pages = {11 -- 17}, year = {2010}, language = {de} } @article{ButenwegBursiPaolaccietal.2021, author = {Butenweg, Christoph and Bursi, Oreste S. and Paolacci, Fabrizio and Marinković, Marko and Lanese, Igor and Nardin, Chiara and Quinci, Gianluca}, title = {Seismic performance of an industrial multi-storey frame structure with process equipment subjected to shake table testing}, series = {Engineering Structures}, volume = {243}, journal = {Engineering Structures}, number = {15}, editor = {Yang, J.}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0141-0296}, doi = {10.1016/j.engstruct.2021.112681}, year = {2021}, abstract = {Past earthquakes demonstrated the high vulnerability of industrial facilities equipped with complex process technologies leading to serious damage of process equipment and multiple and simultaneous release of hazardous substances. Nonetheless, current standards for seismic design of industrial facilities are considered inadequate to guarantee proper safety conditions against exceptional events entailing loss of containment and related consequences. On these premises, the SPIF project -Seismic Performance of Multi-Component Systems in Special Risk Industrial Facilities- was proposed within the framework of the European H2020 SERA funding scheme. In detail, the objective of the SPIF project is the investigation of the seismic behaviour of a representative industrial multi-storey frame structure equipped with complex process components by means of shaking table tests. Along this main vein and in a performance-based design perspective, the issues investigated in depth are the interaction between a primary moment resisting frame (MRF) steel structure and secondary process components that influence the performance of the whole system; and a proper check of floor spectra predictions. The evaluation of experimental data clearly shows a favourable performance of the MRF structure, some weaknesses of local details due to the interaction between floor crossbeams and process components and, finally, the overconservatism of current design standards w.r.t. floor spectra predictions.}, language = {en} } @article{ButenwegEbenauKarvaneketal.2003, author = {Butenweg, Christoph and Ebenau, C. and Karvanek, E. and Thierauf, G.}, title = {Bautechnische Pr{\"u}fung und Bau{\"u}berwachung der Arena 'Auf Schalke'}, series = {Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen ; offizielle Zeitschrift der VDI-Gesellschaft Bautechnik}, volume = {Bd. 78}, journal = {Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen ; offizielle Zeitschrift der VDI-Gesellschaft Bautechnik}, number = {Nr. 5}, issn = {0005-6650}, pages = {215 -- 220}, year = {2003}, language = {de} } @article{ButenwegFehling2012, author = {Butenweg, Christoph and Fehling, Ekkehard}, title = {Hintergrund f{\"u}r die vereinfachten Regeln bei Mauerwerksgeb{\"a}uden im Erdbebenfall}, series = {Mauerwerk : European journal of masonry}, volume = {Volume 16}, journal = {Mauerwerk : European journal of masonry}, number = {Issue 3}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1022 (E-Journal); 1432-3427 (Print)}, doi = {10.1002/dama.201200537}, pages = {127 -- 137}, year = {2012}, abstract = {Bei der Ausarbeitung des nationalen Anwendungsdokumentes zur DIN EN 1998-1 waren die in der ENV-Fassung enthaltenen vereinfachten Regeln im Lichte aktueller Forschungsergebnisse zu {\"u}berpr{\"u}fen und zu {\"u}berarbeiten. Die gleiche Aufgabe stellte sich auch f{\"u}r die Neufassung der DIN 4149. In beiden F{\"a}llen sind neben konstruktiven Regeln f{\"u}r die Art und Anordnung der zur Geb{\"a}udeaussteifung heranzuziehenden W{\"a}nde im Grundriss Tabellen enthalten, die unter bestimmten Bedingungen den Entfall eines rechnerischen Nachweises der Tragw{\"a}nde im Erdbebenfall erm{\"o}glichen. Dies ist f{\"u}r Schwachbebengebiete, wie sie in Deutschland und anderen L{\"a}ndern Mitteleuropas anzutreffen sind, sinnvoll, um unn{\"o}tigen Rechenaufwand sowie Probleme mit der F{\"u}hrbarkeit von Nachweisen so weit wie m{\"o}glich auszuschalten. Im vorliegenden Beitrag werden die Hintergr{\"u}nde der vereinfachten Regeln diskutiert und die Ergebnisse der Anwendung mit verschiedenen Rechenverfahren verglichen und bewertet.}, language = {de} } @article{ButenwegFaeckeFehlingetal.2010, author = {Butenweg, Christoph and F{\"a}cke, Andreas and Fehling, Ekkehard and Gellert, Christoph and Gierga, Michael and Meyer, Udo and R{\"u}tschlin, Andreas H. and St{\"u}rz, Jochen}, title = {Energieeffizient und erdbebensicher Bauen mit monolithischem Ziegelmauerwerk}, series = {Mauerwerk : European journal of masonry}, volume = {14}, journal = {Mauerwerk : European journal of masonry}, number = {1}, publisher = {Ernst \& Sohn}, address = {Berlin}, issn = {1432-3427}, doi = {10.1002/dama.201000456}, pages = {3 -- 9}, year = {2010}, abstract = {Moderne Bauwerke m{\"u}ssen heute eine hohe energetische Leistungsf{\"a}higkeit aufweisen und gleichzeitig alle einwirkenden Lasten sicher abtragen. Dies stellt insbesondere in Erdbebengebieten hohe Anforderungen an die verwendeten Baustoffe. Am baupraktischen Beispiel einer Doppelhaush{\"a}lfte wird demonstriert, dass die Symbiose aus energieeffizientem und gleichzeitig erdbebensicherem Bauen in der h{\"o}chsten deutschen Erdbebenzone mit monolithischem Ziegelmauerwerk gut realisierbar ist. Als Ziegelmauerwerk werden f{\"u}r die Außenw{\"a}nde w{\"a}rmetechnisch optimierte Hochlochziegel verwendet, die sowohl die Anforderungen der Energieeinsparverordnung 2009 als auch die Anforderungen an Mauerwerkbaustoffe nach den aktuellen Erdbebennormen erf{\"u}llen. Der Erdbebennachweis der Doppelhaush{\"a}lfte erfolgt mit einem nichtlinearen Nachweisverfahren, das f{\"u}r eine einfache praktische Anwendung programmtechnisch umgesetzt wurde. F{\"u}r den Nachweis wurden aus zyklischen Schubwandversuchen ermittelte Last-Verformungskurven verwendet. Das gesamte in Deutschland noch nicht normativ geregelte Nachweiskonzept wurde im Rahmen einer Zustimmung im Einzelfall gepr{\"u}ft und genehmigt.}, language = {de} } @article{ButenwegGellert2012, author = {Butenweg, Christoph and Gellert, Christoph}, title = {Integrale Geb{\"a}udeplanung am Beispiel eines Geschossbaus in Ziegelmauerwerk}, series = {Mauerwerk : European journal of masonry}, volume = {Volume 16}, journal = {Mauerwerk : European journal of masonry}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1022 (E-Journal); 1432-3427 (Print)}, doi = {10.1002/dama.201200550}, pages = {247 -- 254}, year = {2012}, abstract = {Moderne Mauerwerksbauten m{\"u}ssen nach heutigen Anforderungen architektonisch, statisch, energetisch sowie schall- und brandschutztechnisch optimal ausgelegt sein. Aufgrund der Komplexit{\"a}t und engen Verzahnung der einzelnen Anforderungen ist eine integrale Geb{\"a}udeplanung zur Erzielung einer qualitativ hochwertigen Bauwerksl{\"o}sung unbedingt notwendig. Diese erfordert von den Fachplanern vertieftes Spezialwissen in den verschiedenen Bereichen, um insbesondere die Schnittstellen und Bauwerksdetails korrekt zu planen und auszuf{\"u}hren. Der Beitrag stellt die integrale Geb{\"a}udeplanung am Beispiel eines Geschossbaus in Ziegelbauweise mit L{\"o}sungen f{\"u}r wesentliche Detailpunkte vor}, language = {de} }