@article{AuffrayBruyndonckxDevroedeetal.2004, author = {Auffray, E. and Bruyndonckx, P. and Devroede, O. and Fedorov, A. and Ziemons, Karl}, title = {The ClearPET project}, series = {Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, volume = {527}, journal = {Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, number = {1-2}, isbn = {0168-9002}, pages = {171 -- 174}, year = {2004}, abstract = {The Crystal Clear Collaboration has designed and is building a high-resolution small animal PET scanner. The design is based on the use of the Hamamatsu R7600-M64 multi-anode photomultiplier tube and a LSO/LuYAP phoswich matrix with one to one coupling between the crystals and the photo-detector. The complete system will have 80 PM tubes in four rings with an inner diameter of 137 mm and an axial field of view of 110 mm. The PM pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. Simulations, and measurements a 2×4 module test set-up predict a spatial resolution of 1.5 mm in the centre of the field of view and a sensitivity of 5.9\% for a point source in the centre of the field of view.}, language = {en} } @article{BeerStreunHombachetal.2010, author = {Beer, S. and Streun, M. and Hombach, T. and Buehler, J. and Jahnke, S. and Khodaverdi, M. and Larue, H. and Minwuyelet, S. and Parl, C. and Roeb, G. and Schurr, U. and Ziemons, Karl}, title = {Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants}, series = {Physics in Medicine and Biology}, volume = {55}, journal = {Physics in Medicine and Biology}, number = {3}, publisher = {IOP}, address = {Bristol}, issn = {1361-6560}, doi = {10.1088/0031-9155/55/3/006}, pages = {635 -- 646}, year = {2010}, abstract = {Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements.}, language = {en} } @article{BerghoffLanskeSchultzeetal.1988, author = {Berghoff, G. and Lanske, D. and Schultze, K. and Ziemons, Karl}, title = {Jets and QCD-effects in muon-nuclean scattering}, series = {Verhandlungen der Deutschen Physikalischen Gesellschaft}, volume = {23}, journal = {Verhandlungen der Deutschen Physikalischen Gesellschaft}, number = {5}, isbn = {0420-0195}, year = {1988}, language = {en} } @article{BoeckerKuwertLangenetal.1994, author = {Boecker, Henning and Kuwert, Torsten and Langen, Karl-J. and Lange, Herwig W. and Czech, Norbert and Ziemons, Karl and Herzog, Hans and Shikare, Shekar and Weindl, Anton and Feinendegen, Ludwig E.}, title = {SPECT with HMPAO compared to PET with FDG in Huntington disease}, series = {Journal of Computer Assisted Tomography}, volume = {18}, journal = {Journal of Computer Assisted Tomography}, number = {4}, isbn = {1532-3145}, pages = {542 -- 548}, year = {1994}, language = {en} } @article{BussmannEngelsFussetal.2000, author = {Bussmann, N. and Engels, R. and Fuss, L. and Kemmerling, G. and Reinartz, R. and Langen, K.-J. and Schelten, J. and Ziemons, Karl}, title = {Performance measurement of a new high resolution detector system for I-131 thyroid studies}, series = {2000 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, journal = {2000 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, issn = {1082-3654}, pages = {22/35 -- 22/37}, year = {2000}, abstract = {A 2-dimensional detector system for high resolution thyroid I-131 scintigraphy was developed. It has a sensitive area of 4 cm×4 cm and consists of a lead-collimator and an array of 10×10 EGO crystals combined with a position sensitive photomultiplier. The spatial resolution and the sensitivity of the detector has been measured and compared to two commercially available gamma-cameras. Furthermore first patient measurements have been carried out}, language = {de} } @article{ChoiFelderFelderetal.2020, author = {Choi, Chang-Hoon and Felder, Tim and Felder, J{\"o}rg and Tellmann, Lutz and Hong, Suk-Min and Wegener, Hans-Peter and Shah, N Jon and Ziemons, Karl}, title = {Design, evaluation and comparison of endorectal coils for hybrid MR-PET imaging of the prostate}, series = {Physics in Medicine \& Biology}, volume = {65}, journal = {Physics in Medicine \& Biology}, number = {11}, publisher = {IOP}, address = {Bristol}, issn = {0031-9155}, doi = {10.1088/1361-6560/ab87f8}, year = {2020}, abstract = {Prostate cancer is one of the most common cancers among men and its early detection is critical for its successful treatment. The use of multimodal imaging, such as MR-PET, is most advantageous as it is able to provide detailed information about the prostate. However, as the human prostate is flexible and can move into different positions under external conditions, it is important to localise the focused region-of-interest using both MRI and PET under identical circumstances. In this work, we designed five commonly used linear and quadrature radiofrequency surface coils suitable for hybrid MR-PET use in endorectal applications. Due to the endorectal design and the shielded PET insert, the outer face of the coils investigated was curved and the region to be imaged was outside the volume of the coil. The tilting angles of the coils were varied with respect to the main magnetic field direction. This was done to approximate the various positions from which the prostate could be imaged. The transmit efficiencies and safety excitation efficiencies from simulations, together with the signal-to-noise ratios from the MR images were calculated and analysed. Overall, it was found that the overlapped loops driven in quadrature were superior to the other types of coils we tested. In order to determine the effect of the different coil designs on PET, transmission scans were carried out, and it was observed that the differences between attenuation maps with and without the coils were negligible. The findings of this work can provide useful guidance for the integration of such coil designs into MR-PET hybrid systems in the future.}, language = {en} } @article{ChristHollendungLarueetal.2004, author = {Christ, D. and Hollendung, A. and Larue, H. and Parl, C. and Streun, M. and Weber, S. and Ziemons, Karl and Halling, H.}, title = {Homogenization of the MultiChannel PM gain by inserting light attenuating masks}, series = {2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4}, journal = {2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4}, issn = {1082-3654}, pages = {2382 -- 2385}, year = {2004}, abstract = {MultiChannel Photomultipliers (PM), like the R7600-00-M64 or R5900-00-M64 from Hamamatsu, are often chosen as photodetectors in high-resolution positron emission tomography (PET). A major problem of this PM is the nonuniform channel gain. In order to solve this problem, light attenuating masks were created. The aim of the masks is a homogenization of the output of all 64 channels using different hole sizes at the channel positions. The hole area, which is individually defined for the different channels, is inversely proportional to the channel gain. The measurements by inserting light attenuating masks improved a homogenization to a ratio of 1:1.2.}, language = {en} } @article{ErkiKleinesZiemonsetal.1997, author = {Erki, I. and Kleines, H. and Ziemons, Karl and Zwoll, K.}, title = {Interaktives System zur Darstellung funktionaler Bilddaten}, series = {Bildverarbeitung f{\"u}r die Medizin : Algorithmen - Systeme - Anwendungen}, journal = {Bildverarbeitung f{\"u}r die Medizin : Algorithmen - Systeme - Anwendungen}, editor = {Lehmann, Thomas}, publisher = {Verl. der. Augustinus-Buchh.}, address = {Aachen}, isbn = {3-86073-519-5}, pages = {249 -- 254}, year = {1997}, language = {de} } @article{FinkMarshallShahetal.2000, author = {Fink, G. R. and Marshall, J. C. and Shah, N. J. and Weiss, P.H. and Halligan, P. W. and Grosse-Ruyken, M. and Ziemons, Karl and Zilles, K. and Freund, H. J.}, title = {Line bisection judgments implicate right parietal cortex and cerebellum as assessed by fMRI}, series = {Neurology}, volume = {54}, journal = {Neurology}, number = {6}, isbn = {1526-632X}, pages = {1324 -- 1331}, year = {2000}, language = {en} } @article{GaribaldiBegingCaneseetal.2017, author = {Garibaldi, F. and Beging, Stefan and Canese, R. and Carpinelli, G. and Clinthorne, N. and Colilli, S. and Cosentino, L. and Finocchiaro, P. and Giuliani, F. and Gricia, M. and Lucentini, M. and Majewski, S. and Monno, E. and Musico, P. and Santavenere, F. and T{\"o}dter, J. and Wegener, Hans-Peter and Ziemons, Karl}, title = {A novel TOF-PET MRI detector for diagnosis and follow up of the prostate cancer}, series = {European Physical Journal Plus}, volume = {132}, journal = {European Physical Journal Plus}, number = {9}, publisher = {Springer}, address = {Berlin}, issn = {2190-5444}, doi = {10.1140/epjp/i2017-11662-x}, year = {2017}, language = {en} }