@article{MurganBeyerKotliaretal.2013, author = {Murgan, Ilina and Beyer, Sonja and Kotliar, Konstantin and Weber, Lutz and Bechtold-Dalla Pozza, Susanne and Dalla Pozza, Robert and Wegner, Aharon and Sitnikova, Diana and Stock, Konrad and Heemann, Uwe and Schmaderer, Christoph and Baumann, M.}, title = {Arterial and Retinal Vascular Changes in Hypertensive and Prehypertensive Adolescents}, series = {American Journal of Hypertension}, volume = {26}, journal = {American Journal of Hypertension}, number = {3}, publisher = {Oxford University Press}, address = {Oxford}, issn = {1941-7225}, pages = {400 -- 408}, year = {2013}, language = {de} } @article{KotliarHanssenEberhardtetal.2013, author = {Kotliar, Konstantin and Hanssen, Henner and Eberhardt, Karla and Vilser, Walthard and Schmaderer, Christoph and Halle, Martin and Heemann, Uwe and Baumann, M.}, title = {Retinal pulse wave velocity in young male normotensive and mildly hypertensive subjects}, series = {Microcirculation}, journal = {Microcirculation}, publisher = {Wiley}, address = {Malden}, issn = {1549-8719}, year = {2013}, language = {en} } @article{ReisertSchneiderGeissleretal.2013, author = {Reisert, Steffen and Schneider, Benno and Geissler, Hanno and Gompel, Matthias van and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Multi-sensor chip for the investigation of different types of metal oxides for the detection of H2O2 in the ppm range}, series = {physica status solidi (a)}, volume = {210}, journal = {physica status solidi (a)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, pages = {898 -- 904}, year = {2013}, abstract = {In this work, a multi-sensor chip for the investigation of the sensing properties of different types of metal oxides towards hydrogen peroxide in the ppm range is presented. The fabrication process and physical characterization of the multi-sensor chip are described. Pure SnO2 and WO3 as well as Pd- and Pt-doped SnO2 films are characterized in terms of their sensitivity to H2O2. The sensing films have been prepared by drop-coating of water-dispensed nano-powders. A physical characterization, including scanning electron microscopy and X-ray diffraction analysis of the deposited metal-oxide films, was done. From the measurements in hydrogen peroxide atmosphere, it could be shown, that all of the tested metal oxide films are suitable for the detection of H2O2 in the ppm range. The highest sensitivity and reproducibility was achieved using Pt-doped SnO2. Calibration plot of a SnO2, WO3, Pt-, and Pd-doped SnO2 gas sensor for H2O2 concentrations in the ppm range.}, language = {en} } @article{HennemannKohlReisertetal.2013, author = {Hennemann, J{\"o}rg and Kohl, Claus-Dieter and Reisert, Steffen and Kirchner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Copper oxide nanofibres for detection of hydrogen peroxide vapour at high concentrations}, series = {physica status solidi (a)}, volume = {210}, journal = {physica status solidi (a)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201200775}, pages = {859 -- 863}, year = {2013}, abstract = {We present a sensor concept based on copper(II)oxide (CuO) nanofibres for the detection of hydrogen peroxide (H2O2) vapour in the percent per volume (\% v/v) range. The fibres were produced by using the electrospinning technique. To avoid water condensation in the pores, the fibres were initially modified by an exposure to H2S to get an enclosed surface. By a thermal treatment at 350 °C the fibres were oxidised back to CuO. Thereby, the visible pores disappear which was verified by SEM analysis. The fibres show a decrease of resistance with increasing H2O2 concentration which is due to the fact that hydrogen peroxide is an oxidising gas and CuO a p-type semiconductor. The sensor shows a change of resistance within the minute range to the exposure until the maximum concentration of 6.9\% v/v H2O2. At operating temperatures below 450 °C the corresponding sensor response to a concentration of 4.1\% v/v increases. The sensor shows a good reproducibility of the signal at different measurements. CuO seems to be a suitable candidate for the detection of H2O2 vapour at high concentrations. Resistance behaviour of the sensor under exposure to H2O2 vapours between 2.3 and 6.9\% v/v at an operating temperature of 450 °C.}, language = {en} } @incollection{RoethKampkerReisgenetal.2013, author = {R{\"o}th, Thilo and Kampker, Achim and Reisgen, Uwe and Hameyer, Kay and De Doncker, R. W.}, title = {Entwicklung von elektrofahrzeugspezifischen Systemen}, series = {Elektromobilit{\"a}t : Grundlagen einer Zukunftstechnologie}, booktitle = {Elektromobilit{\"a}t : Grundlagen einer Zukunftstechnologie}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-642-31986-0}, pages = {235 -- 336}, year = {2013}, abstract = {Die Fahrzeugkarosserie bildet als gr{\"o}ßte funktionale und organisatorische Systemeinheit ein zentrales Kompetenzfeld der OEMs. F{\"u}r den Fahrzeughersteller stellt der Karosserierohbau eine hohe Kernkompetenz sowohl in der Produktentwicklung als auch in der Produktion dar. Neue, innovative Karosseriebauweisen, bspw. aufgrund eines neuen Fahrzeugkonzeptes oder neuer Anforderungen, bedeuten f{\"u}r den OEM auch gleichzeitig die intensive Auseinandersetzung mit Kompetenzfokussierung bzw. Wertsch{\"o}pfungsverlagerungen.}, language = {de} } @article{KirchnerOberlaenderSusoetal.2013, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Suso, Henri-Pierre and Rysstad, Gunnar and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Towards a wireless sensor system for real-time H2O2 monitoring in aseptic food processes}, series = {Physica status solidi (a)}, volume = {210}, journal = {Physica status solidi (a)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201200920}, pages = {877 -- 883}, year = {2013}, abstract = {A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests.}, language = {en} } @article{GebhardtFateri2013, author = {Gebhardt, Andreas and Fateri, Miranda}, title = {3D printing and its applications}, series = {RTejournal - Forum f{\"u}r Rapid Technologie}, volume = {10}, journal = {RTejournal - Forum f{\"u}r Rapid Technologie}, number = {1}, publisher = {Fachhochschule Aachen}, address = {Aachen}, issn = {1614-0923}, url = {http://nbn-resolving.de/urn:nbn:de:0009-2-35626}, year = {2013}, abstract = {Eine zunehmende Anzahl von Artikeln in Publikumszeitschriften und Journalen r{\"u}ckt die direkte Herstellung von Bauteilen und Figuren immer mehr in das Bewusstsein einer breiten {\"O}ffentlichkeit. Leider ergibt sich nur selten ein einigermaßen vollst{\"a}ndiges Bild davon, wie und in welchen Lebensbereichen diese Techniken unseren Alltag ver{\"a}ndern werden. Das liegt auch daran, dass die meisten Artikel sehr technisch gepr{\"a}gt sind und sich nur punktuell auf Beispiele st{\"u}tzen. Dieser Beitrag geht von den Bed{\"u}rfnissen der Menschen aus, wie sie z.B. in der Maslow'schen Bed{\"u}rfnispyramide strukturiert dargestellt sind und unterstreicht dadurch, dass 3D Printing (oder Additive Manufacturing resp. Rapid Prototyping) bereits alle Lebensbereiche erfasst hat und im Begriff ist, viele davon zu revolutionieren.}, language = {en} } @book{Hoever2013, author = {Hoever, Georg}, title = {Arbeitsbuch h{\"o}here Mathematik : Aufgaben mit vollst{\"a}ndig durchgerechneten L{\"o}sungen}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-642-30336-4}, pages = {XII, 524 S.}, year = {2013}, language = {de} } @book{Hoever2013, author = {Hoever, Georg}, title = {H{\"o}here Mathematik kompakt}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-642-30334-0}, pages = {X, 245 S.}, year = {2013}, language = {de} } @article{KirchnerOberlaenderSucoetal.2013, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Suco, Henri-Pierre and Rysstad, Gunnar and Sch{\"o}ning, Michael Josef}, title = {Monitoring the microbicidal effectiveness of gaseous hydrogen peroxide in sterilisation processes by means of a calorimetric gas sensor}, series = {Food control}, volume = {31}, journal = {Food control}, number = {2}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0956-7135}, doi = {10.1016/j.foodcont.2012.11.048}, pages = {530 -- 538}, year = {2013}, abstract = {In the present work, a novel method for monitoring sterilisation processes with gaseous H2O2 in combination with heat activation by means of a specially designed calorimetric gas sensor was evaluated. Therefore, the sterilisation process was extensively studied by using test specimens inoculated with Bacillus atrophaeus spores in order to identify the most influencing process factors on its microbicidal effectiveness. Besides the contact time of the test specimens with gaseous H2O2 varied between 0.2 and 0.5 s, the present H2O2 concentration in a range from 0 to 8\% v/v (volume percent) had a strong influence on the microbicidal effectiveness, whereas the change of the vaporiser temperature, gas flow and humidity were almost negligible. Furthermore, a calorimetric H2O2 gas sensor was characterised in the sterilisation process with gaseous H2O2 in a wide range of parameter settings, wherein the measurement signal has shown a linear response against the H2O2 concentration with a sensitivity of 4.75 °C/(\% v/v). In a final step, a correlation model by matching the measurement signal of the gas sensor with the microbial inactivation kinetics was established that demonstrates its suitability as an efficient method for validating the microbicidal effectiveness of sterilisation processes with gaseous H2O2.}, language = {en} }