@incollection{AtmaneHirechKassmietal.2020, author = {Atmane, Ilias and Hirech, Kamal and Kassmi, K. and Mahdi, Zahra and Alexopoulos, Spiros and Schwarzer, Klemens and Chayeb, H. and Bachiri, N.}, title = {Design and realization of a pilot solar desalination plant in Douar El Hamri in the province of Berkane (Morocco)}, series = {Sustainable entrepreneurship, renewable energy-based projects, and digitalization}, booktitle = {Sustainable entrepreneurship, renewable energy-based projects, and digitalization}, editor = {Omrane, Amina and Kassmi, Khalil and Akram, Muhammad Wasim and Khanna, Ashish and Mostafiz, Imtiaz}, publisher = {CRC Press}, address = {Boca Raton, Fa.}, isbn = {9781000292541 (E-Book)}, pages = {18 Seiten}, year = {2020}, abstract = {Producing fresh water from saline water has become one of the most difficult challenges to overcome especially with the high demand and shortage of fresh water. In this context, as part of a collaboration with Germany, the authors propose a design and implementation of a pilot multi-stage solar desalination system (MSD), remotely controlled, at Douar Al Hamri in the rural town of Boughriba in the province of Berkane, Morocco. More specifically, they present their contribution on the remote control and supervision system, which makes the functioning of the MSD system reliable and guarantees the production of drinking water for the population of Douar. The results obtained show that the electronic cards and computer communication software implemented allow the acquisition of all electrical (currents, voltages, powers, yields), thermal (temperatures of each stage), and meteorological (irradiance and ambient temperature), remote control and maintenance (switching on, off, data transfer). By comparing with the literature carried out in the field of solar energy, the authors conclude that the MSD and electronic desalination systems realized during this work represent a contribution in terms of the reliability and durability of providing drinking water in rural and urban areas.}, language = {en} } @book{LabischWaehlisch2020, author = {Labisch, Susanna and W{\"a}hlisch, Georg}, title = {Technisches Zeichnen: Eigenst{\"a}ndig lernen und effektiv {\"u}ben}, edition = {6th ed.}, publisher = {Springer Vieweg}, address = {Wiesbaden}, isbn = {978-3-658-30650-2 (E-Book)}, doi = {10.1007/978-3-658-30650-2}, pages = {Online-Ressource (XI, 296 S. 300 Abb., 81 Abb. in Farbe)}, year = {2020}, language = {de} } @inproceedings{MarinkovicButenweg2020, author = {Marinkovic, Marko and Butenweg, Christoph}, title = {Seismic behaviour of RC frames with uncoupled masonry infills having two storeys or two bays}, series = {Brick and Block Masonry - From Historical to Sustainable Masonry. Proceedings of the 17th International Brick/Block Masonry Conference}, booktitle = {Brick and Block Masonry - From Historical to Sustainable Masonry. Proceedings of the 17th International Brick/Block Masonry Conference}, publisher = {CRC Press}, address = {London}, doi = {10.1201/9781003098508-72}, pages = {1 -- 7}, year = {2020}, abstract = {Reinforced concrete (RC) structures with masonry infills are widely used for several types of buildings all over the world. However, it is well known that traditional masonry infills constructed with rigid contact to the surrounding RC frame performed rather poor in past earthquakes. Masonry infills showed severe in-plane damages and failed in many cases under out-of-plane seismic loading. As the undesired interactions between frames and infills changes the load transfer on building level, complete collapses of buildings were observed. A possible solution is uncoupling of masonry infills to the frame to reduce the infill contribution activated by the frame deformation under horizontal loading. The paper presents numerical simulations on RC frames equipped with the innovative decoupling system INODIS. The system was developed within the European project INSYSME and allows an effective uncoupling of frame and infill. The simulations are carried out with a micro-modelling approach, which is able to predict the complex nonlinear behaviour resulting from the different materials and their interaction. Each brick is modelled individually and connected taking into account nonlinearity of a brick mortar interface. The calibration of the model is based on small specimen tests and experimental results for one bay one storey frame are used for the validation. The validated model is further used for parametric studies on two storey and two bay infilled frames. The response and change of the structural stiffness are analysed and compared to the traditionally infilled frame. The results confirm the effectiveness of the INODIS system with less damage and relatively low contribution of the infill at high drift levels. In contrast to the uncoupled system configurations, traditionally infilled frames experienced brittle failure at rather low drift levels.}, language = {en} } @inproceedings{MichelRosinButenwegetal.2020, author = {Michel, Philipp and Rosin, Julia and Butenweg, Christoph and Klinkel, Sven}, title = {Soil-dependent earthquake spectra in the analysis of liquid-storage-tanks on compliant soil}, series = {Seismic design of industrial facilities 2020}, booktitle = {Seismic design of industrial facilities 2020}, publisher = {Apprimus Verlag}, address = {Aachen}, isbn = {978-3-86359-729-0}, pages = {245 -- 254}, year = {2020}, abstract = {A further development of the Added-Mass-Method allows the combined representation of the effects of both soil-structure-interaction and fluid-structure interaction on a liquid-filled-tank in one model. This results in a practical method for describing the dynamic fluid pressure on the tank shell during joint movement. The fluid pressure is calculated on the basis of the tank's eigenform and the earthquake acceleration and represented by additional masses on the shell. The bearing on compliant ground is represented by replacement springs, which are calculated dependent on the local soil composition. The influence of the shear modulus of the compliant soil is clearly visible in the pressure curves and the stress distribution in the shell. The acceleration spectra are also dependent on soil stiffness. According to Eurocode-8 the acceleration spectra are determined for fixed soil-classes, instead of calculating the accelerations for each site in direct dependence on the soil composition. This leads to unrealistic sudden changes in the system's response. Therefore, earthquake spectra are calculated for different soil models in direct dependence of the shear modulus. Thus, both the acceleration spectra and the replacement springs match the soil composition. This enables a reasonable and consistent calculation of the system response for the actual conditions at each site.}, language = {en} } @inproceedings{MarkinkovicButenwegPaveseetal.2020, author = {Markinkovic, Marko and Butenweg, Christoph and Pavese, A. and Lanese, I. and Hoffmeister, B. and Pinkawa, M. and Vulcu, C. and Bursi, O. and Nardin, C. and Paolacci, F. and Quinci, G. and Fragiadakis, M. and Weber, F. and Huber, P. and Renault, P. and G{\"u}ndel, M. and Dyke, S. and Ciucci, M. and Marino, A.}, title = {Investigation of the seismic behaviour of structural and nonstructural components in industrial facilities by means of shaking table tests}, series = {Seismic design of industrial facilities 2020}, booktitle = {Seismic design of industrial facilities 2020}, publisher = {Apprimus Verlag}, address = {Aachen}, isbn = {978-3-86359-729-0}, pages = {159 -- 172}, year = {2020}, language = {en} } @inproceedings{CacciatoreButenweg2020, author = {Cacciatore, Pamela and Butenweg, Christoph}, title = {Seismic safety of cylindrical granular material steel silos under seismic loading}, series = {Seismic design of industrial facilities 2020}, booktitle = {Seismic design of industrial facilities 2020}, publisher = {Apprimus Verlag}, address = {Aachen}, isbn = {978-3-86359-729-0}, pages = {231 -- 244}, year = {2020}, language = {en} } @inproceedings{TomićPennaDeJongetal.2020, author = {Tomić, Igor and Penna, Andrea and DeJong, Matthew and Butenweg, Christoph and Correia, Ant{\´o}nio A. and Candeias, Paulo X. and Senaldi, Ilaria and Guerrini, Gabriele and Malomo, Daniele and Beyer, Katrin}, title = {Seismic testing of adjacent interacting masonry structures}, series = {12th International Conference on Structural Analysis of Historical Constructions (SAHC 2020)}, booktitle = {12th International Conference on Structural Analysis of Historical Constructions (SAHC 2020)}, doi = {10.23967/sahc.2021.234}, pages = {1 -- 12}, year = {2020}, abstract = {In many historical centres in Europe, stone masonry buildings are part of building aggregates, which developed when the layout of the city or village was densified. In these aggregates, adjacent buildings share structural walls to support floors and roofs. Meanwhile, the masonry walls of the fa{\c{c}}ades of adjacent buildings are often connected by dry joints since adjacent buildings were constructed at different times. Observations after for example the recent Central Italy earthquakes showed that the dry joints between the building units were often the first elements to be damaged. As a result, the joints opened up leading to pounding between the building units and a complicated interaction at floor and roof beam supports. The analysis of such building aggregates is very challenging and modelling guidelines do not exist. Advances in the development of analysis methods have been impeded by the lack of experimental data on the seismic response of such aggregates. The objective of the project AIMS (Seismic Testing of Adjacent Interacting Masonry Structures), included in the H2020 project SERA, is to provide such experimental data by testing an aggregate of two buildings under two horizontal components of dynamic excitation. The test unit is built at half-scale, with a two-storey building and a one-storey building. The buildings share one common wall while the fa{\c{c}}ade walls are connected by dry joints. The floors are at different heights leading to a complex dynamic response of this smallest possible building aggregate. The shake table test is conducted at the LNEC seismic testing facility. The testing sequence comprises four levels of shaking: 25\%, 50\%, 75\% and 100\% of nominal shaking table capacity. Extensive instrumentation, including accelerometers, displacement transducers and optical measurement systems, provides detailed information on the building aggregate response. Special attention is paid to the interface opening, the globa}, language = {en} } @article{MarinkovicButenweg2020, author = {Marinkovic, Marko and Butenweg, Christoph}, title = {Earthquake-proof system for masonry infills in RC frame structures}, series = {International Journal of Masonry Research and Innovation}, volume = {5}, journal = {International Journal of Masonry Research and Innovation}, number = {2}, publisher = {Inderscience Enterprises}, address = {Olney, Bucks}, issn = {2056-9467}, doi = {10.1504/IJMRI.2020.106328}, pages = {185 -- 208}, year = {2020}, language = {de} } @article{ElDeibButenwegKlinkel2020, author = {El-Deib, Khaled and Butenweg, Christoph and Klinkel, Sven}, title = {Erdbebennachweis von Mauerwerksbauten mit realistischen Modellen und erh{\"o}hten Verhaltensbeiwerten}, series = {Bautechnik}, volume = {97}, journal = {Bautechnik}, number = {11}, publisher = {Ernst \& Sohn}, address = {Berlin}, doi = {10.1002/bate.202000016}, pages = {756 -- 765}, year = {2020}, abstract = {Die Anwendung des linearen Nachweiskonzepts auf Mauerwerksbauten f{\"u}hrt dazu, dass bereits heute Standsicherheitsnachweise f{\"u}r Geb{\"a}ude mit {\"u}blichen Grundrissen in Gebieten mit moderaten Erdbebeneinwirkungen nicht mehr gef{\"u}hrt werden k{\"o}nnen. Diese Problematik wird sich in Deutschland mit der Einf{\"u}hrung kontinuierlicher probabilistischer Erdbebenkarten weiter versch{\"a}rfen. Aufgrund der Erh{\"o}hung der seismischen Einwirkungen, die sich vielerorts ergibt, ist es erforderlich, die vorhandenen, bislang nicht ber{\"u}cksichtigten Tragf{\"a}higkeitsreserven in nachvollziehbaren Nachweiskonzepten in der Baupraxis verf{\"u}gbar zu machen. Der vorliegende Beitrag stellt ein Konzept f{\"u}r die geb{\"a}udespezifische Ermittlung von erh{\"o}hten Verhaltensbeiwerten vor. Die Verhaltensbeiwerte setzen sich aus drei Anteilen zusammen, mit denen die Lastumverteilung im Grundriss, die Verformungsf{\"a}higkeit und Energiedissipation sowie die {\"U}berfestigkeiten ber{\"u}cksichtigt werden. F{\"u}r die rechnerische Ermittlung dieser drei Anteile wird ein nichtlineares Nachweiskonzept auf Grundlage von Pushover-Analysen vorgeschlagen, in denen die Interaktionen von W{\"a}nden und Geschossdecken durch einen Einspanngrad beschrieben werden. F{\"u}r die Bestimmung der Einspanngrade wird ein nichtlinearer Modellierungsansatz eingef{\"u}hrt, mit dem die Interaktion von W{\"a}nden und Decken abgebildet werden kann. Die Anwendung des Konzepts mit erh{\"o}hten geb{\"a}udespezifischen Verhaltensbeiwerten wird am Beispiel eines Mehrfamilienhauses aus Kalksandsteinen demonstriert. Die Ergebnisse der linearen Nachweise mit erh{\"o}hten Verhaltensbeiwerten f{\"u}r dieses Geb{\"a}ude liegen deutlich n{\"a}her an den Ergebnissen nichtlinearer Nachweise und somit bleiben {\"u}bliche Grundrisse in Erdbebengebieten mit den traditionellen linearen Rechenans{\"a}tzen nachweisbar.}, language = {de} } @article{MarinkovicButenweg2020, author = {Marinkovic, Marko and Butenweg, Christoph}, title = {Ausfachungen aus Ziegelmauerwerk in Stahlbetonrahmentragwerken unter Erdbebenbeanspruchung}, series = {Mauerwerk}, volume = {24}, journal = {Mauerwerk}, number = {4}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1022}, doi = {10.1002/dama.202000011}, pages = {194 -- 205}, year = {2020}, abstract = {Stahlbetonrahmentragwerke mit Ausfachungen aus Mauerwerk weisen nach Erdbeben h{\"a}ufig schwere Sch{\"a}den auf. Gr{\"u}nde hierf{\"u}r sind die Beanspruchungen der Ausfachungsw{\"a}nde durch die aufgezwungenen Rahmenverformungen in Wandebene und die gleichzeitig auftretenden Tr{\"a}gheitskr{\"a}fte senkrecht zur Wandebene in Kombination mit der konstruktiven Ausf{\"u}hrung des Ausfachungsmauerwerks. Die Ausfachung wird in der Regel knirsch gegen die Rahmenst{\"u}tzen gemauert, wobei der Verschluss der oberen Fuge mit M{\"o}rtel oder Montageschaum erfolgt. Dadurch kommt es im Erdbebenfall zu lokalen Interaktionen zwischen Ausfachung und Rahmen, die in der Folge zu einem Versagen einzelner Ausfachungsw{\"a}nde oder zu einem sukzessiven Versagen des Gesamtgeb{\"a}udes f{\"u}hren k{\"o}nnen. Die beobachteten Sch{\"a}den waren die Motivation daf{\"u}r, in dem europ{\"a}ischen Forschungsprojekt INSYSME f{\"u}r Stahlbetonrahmentragwerke mit Ausfachungen aus hochw{\"a}rmed{\"a}mmenden Ziegelmauerwerk innovative L{\"o}sungen zur Verbesserung des seismischen Verhaltens zu entwickeln. Der vorliegende Beitrag stellt die im Rahmen des Projekts von den deutschen Projektpartnern (Universit{\"a}t Kassel, SDA-engineering GmbH) entwickelten L{\"o}sungen vor und vergleicht deren seismisches Verhalten mit der traditionellen Ausf{\"u}hrung der Ausfachungsw{\"a}nde. Grundlage f{\"u}r den Vergleich sind statisch-zyklische Wandversuche und Simulationen auf Wandebene. Aus den Ergebnissen werden Empfehlungen f{\"u}r die erdbebensichere Auslegung von Stahlbetonrahmentragwerken mit Ausfachungen aus Ziegelmauerwerk abgeleitet.}, language = {de} }