@article{HeierliPurvesFelberetal.2004, author = {Heierli, Joachim and Purves, Ross S. and Felber, Andreas and Kowalski, Julia}, title = {Verification of nearest-neighbours interpretations in avalanche forecasting}, series = {Annals of Glaciology}, volume = {38}, journal = {Annals of Glaciology}, number = {1}, isbn = {1727-5644}, pages = {84 -- 88}, year = {2004}, abstract = {This paper examines the positive and negative aspects of a range of interpretations of nearest-neighbours models. Measures-oriented and distributionoriented verification methods are applied to categorial, probabilistic and descriptive interpretations of nearest neighbours used operationally in avalanche forecasting in Scotland and Switzerland. The dependence of skill and accuracy measures on base rate is illustrated. The purpose of the forecast and the definition of events are important variables in determining the quality of the forecast. A discussion of the application of different interpretations in operational avalanche forecasting is presented.}, language = {en} } @article{ZiemonsHeinrichsStreunetal.2004, author = {Ziemons, Karl and Heinrichs, U. and Streun, M. and Pietrzyk, U.}, title = {Validation of GEANT3 simulation studies with a dual-head PMT ClearPET™ prototype}, series = {2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5}, journal = {2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5}, issn = {1082-3654}, pages = {3053 -- 3056}, year = {2004}, abstract = {The ClearPET™ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2nd generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET™ camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0\% the simulated intrinsic resolution is about (1.41±0.11)mm compared to the measured of (1.48±0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6\% in axial direction and 3.6\% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry.}, language = {en} } @article{HoffschmidtFendPitzPaaletal.2004, author = {Hoffschmidt, Bernhard and Fend, Thomas and Pitz-Paal, Robert and Reutter, Oliver}, title = {Two novel high-porosity materials as volumetric receivers for concentrated solar radiation / Thomas Fend ; Robert Pitz-Paal ; Oliver Reutter ... Bernhard Hoffschmidt}, series = {Solar energy materials \& solar cells. 84 (2004), H. 1}, journal = {Solar energy materials \& solar cells. 84 (2004), H. 1}, isbn = {0927-0248}, pages = {291 -- 304}, year = {2004}, language = {en} } @article{DerschGeyerHerrmannetal.2004, author = {Dersch, J{\"u}rgen and Geyer, Michael and Herrmann, Ulf and Jones, Scott A. and Kelly, Bruce and Kistner, Rainer and Ortmanns, Winfried and Pitz-Paal, Robert and Price, Henry}, title = {Trough integration into power plants—a study on the performance and economy of integrated solar combined cycle systems}, series = {Energy : the international journal}, volume = {29}, journal = {Energy : the international journal}, number = {5-6 (Special Issue SolarPaces)}, issn = {0360-5442}, doi = {10.1016/S0360-5442(03)00199-3}, pages = {947 -- 959}, year = {2004}, language = {en} } @article{Mang2004, author = {Mang, Thomas}, title = {Thermosensitive Magnetic Nanoparticles for Bioanalytical and Therapeutical Applications}, series = {Biomedizinische Technik = Biomedical Engineering. 49 (2004), H. 2}, journal = {Biomedizinische Technik = Biomedical Engineering. 49 (2004), H. 2}, isbn = {0013-5585}, pages = {1006 -- 1007}, year = {2004}, language = {en} } @article{DigelZhubanovaNojimaetal.2004, author = {Digel, Ilya and Zhubanova, Azhar A. and Nojima, H. and Artmann, Gerhard}, title = {The use of bactericidal effects of cluster ions generated by plasma in medical biotechnology}, series = {Biotechnologija : teorija i praktika (2004)}, journal = {Biotechnologija : teorija i praktika (2004)}, isbn = {1028-9399}, pages = {46 -- 52}, year = {2004}, language = {en} } @article{BlomeWilson2004, author = {Blome, Hans-Joachim and Wilson, Thomas L.}, title = {The entangled Universe}, series = {Relativistic Astrophysics and Cosmology, Proceedings of the 13th Course of the International School of Cosmic Ray Astrophysics, held in Erice, Italy, 2-14 June 2002 / edited by Maurice M. Shapiro ... [et al.]}, journal = {Relativistic Astrophysics and Cosmology, Proceedings of the 13th Course of the International School of Cosmic Ray Astrophysics, held in Erice, Italy, 2-14 June 2002 / edited by Maurice M. Shapiro ... [et al.]}, publisher = {World Scientific Publishing}, address = {New Jersey, NJ}, isbn = {981-238-727-7}, pages = {23 -- 38}, year = {2004}, language = {en} } @article{ZiemonsAchtenAuffrayetal.2004, author = {Ziemons, Karl and Achten, R. and Auffray, E. and M{\"u}ller-Veggian, Mattea}, title = {The ClearPET™ neuro scanner: a dedicated LSO/LuYAP phoswich small animal PET scanner}, series = {2004 IEEE Nuclear Science Symposium conference record : Nuclear Science Symposium, Medical Imaging Conference ; 16 - 22 October 2004, Rome, Italy ; [including the Symposium on Nuclear Power System (SNPS), 14th Room Temperature Semiconductor X- and Gamma-Ray Detectors Workshop and special focus workshops] / NPSS, Nuclear \& Plasma Sciences Society. Guest ed.: J. Anthony Seibert}, journal = {2004 IEEE Nuclear Science Symposium conference record : Nuclear Science Symposium, Medical Imaging Conference ; 16 - 22 October 2004, Rome, Italy ; [including the Symposium on Nuclear Power System (SNPS), 14th Room Temperature Semiconductor X- and Gamma-Ray Detectors Workshop and special focus workshops] / NPSS, Nuclear \& Plasma Sciences Society. Guest ed.: J. Anthony Seibert}, publisher = {IEEE Operations Center}, address = {Piscataway, NJ}, issn = {1082-3654}, pages = {2430 -- 2433}, year = {2004}, language = {en} } @article{ZiemonsAuffrayBarbieretal.2004, author = {Ziemons, Karl and Auffray, E. and Barbier, R. and Brandenburg, G.}, title = {The ClearPET TM LSO/LuYAP phoswich scanner: a high performance small animal PET system}, series = {2003 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, journal = {2003 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, issn = {1082-3654}, pages = {1728 -- 1732}, year = {2004}, abstract = {A 2nd generation high performance small animal PET scanner, called ClearPET™, has been designed and a first prototype is built by working groups of the Crystal Clear Collaboration (CCC). In order to achieve high sensitivity and maintain good uniform spatial resolution over the field of view in high resolution PET systems, it is necessary to extract the depth of interaction (DOI) information and correct for spatial degradation. The design of the first ClearPET™ Demonstrator based on the use of the multi-anode photomultiplier tube (Hamamatsu R7600-M64) and a LSO/LuYAP phoswich matrix. The two crystal layers of 8*8 crystals (2*2*10 mm3) are stacked on each other and mounted without light guide as one to one on the PMT. A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the crystal ring is 137 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. The measurements have been done using the first LSO/LuYAP detector cassettes.}, language = {en} } @article{AuffrayBruyndonckxDevroedeetal.2004, author = {Auffray, E. and Bruyndonckx, P. and Devroede, O. and Fedorov, A. and Ziemons, Karl}, title = {The ClearPET project}, series = {Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, volume = {527}, journal = {Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, number = {1-2}, isbn = {0168-9002}, pages = {171 -- 174}, year = {2004}, abstract = {The Crystal Clear Collaboration has designed and is building a high-resolution small animal PET scanner. The design is based on the use of the Hamamatsu R7600-M64 multi-anode photomultiplier tube and a LSO/LuYAP phoswich matrix with one to one coupling between the crystals and the photo-detector. The complete system will have 80 PM tubes in four rings with an inner diameter of 137 mm and an axial field of view of 110 mm. The PM pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. Simulations, and measurements a 2×4 module test set-up predict a spatial resolution of 1.5 mm in the centre of the field of view and a sensitivity of 5.9\% for a point source in the centre of the field of view.}, language = {en} } @article{StreunBrandenburgBroekeletal.2004, author = {Streun, M. and Brandenburg, G. and Br{\"o}kel, M. and Fuss, L. and Larue, H. and Parl, C. and Zimmermann, E. and Ziemons, Karl and Halling, H.}, title = {The ClearPET data acquisition}, series = {2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5}, journal = {2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5}, issn = {1082-3654}, pages = {3097 -- 3100}, year = {2004}, abstract = {Within the Crystal Clear Collaboration a modular system for a small animal PET scanner (ClearPET™) has been developed. The modularity allows the assembly of scanners of different sizes and characteristics in order to fit the specific needs of the individual member institutions. Now a first demonstrator is being completed in Julich. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to multi-channel photomultipliers (PMTs). A free-running ADC digitizes the signal from the PMT and the complete scintillation pulses are sampled by an FPGA and sent with 20 MB/S to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. An advantage of that is that the coincidence window and the dimensions of the field of view can be adjusted easily. The ClearPET™ demonstrator is equipped with 10240 crystals on 80 PMTs. This paper presents an overview of the data acquisition system.}, language = {en} } @article{ChudobaButenwegPeiffer2004, author = {Chudoba, Rostislav and Butenweg, Christoph and Peiffer, F.}, title = {Technical information system for collaborative material research}, series = {Advances in engineering software}, volume = {Volume 35}, journal = {Advances in engineering software}, number = {Issue 10-11}, issn = {1873-5339 (E-Journal); 0965-9978 (Print)}, doi = {10.1016/j.advengsoft.2004.03.021}, pages = {747 -- 756}, year = {2004}, language = {en} } @article{HellwigVolkmann2004, author = {Hellwig, Angelika and Volkmann, Lutz}, title = {Sufficient conditions for λ′-optimality in graphs of diameter 2}, series = {Discrete mathematics}, volume = {Vol. 283}, journal = {Discrete mathematics}, number = {Iss. 1-3}, issn = {1872-681X (E-Journal); 0012-365X (Print)}, pages = {113 -- 120}, year = {2004}, language = {en} } @article{SelmerAndreiPieriketal.2004, author = {Selmer, Thorsten and Andrei, Paula I. and Pierik, Antonio J. and Zauner, Stefan}, title = {Subunit composition of the glycyl radical enzyme p-hydroxyphenylacetate decarboxylase. A small subunit, HpdC, is essential for catalytic activity / Andrei, PI. ; Pierik, AJ. ; Zauner , S. ; Andrei-Selmer, LC. ; Selmer, T.}, series = {European Journal of Biochemistry. 271 (2004), H. 11}, journal = {European Journal of Biochemistry. 271 (2004), H. 11}, isbn = {0014-2956}, pages = {2225 -- 2230}, year = {2004}, language = {en} } @article{SrnanekGeurtsLentzeetal.2004, author = {Srnanek, R. and Geurts, J. and Lentze, M. and Irmer, G. and Donoval, D. and Brdecka, P. and Kordos, P. and F{\"o}rster, Arnold and Sciana, B. and Radziewicz, D. and Tlaczala, M.}, title = {Study of d-doped GaAs layers by micro-Raman spectroscopy on bevelled samples}, series = {Applied surface science . 230 (2004), H. 1 -4}, journal = {Applied surface science . 230 (2004), H. 1 -4}, isbn = {0169-4332}, pages = {379 -- 385}, year = {2004}, language = {en} } @article{KeusgenSchoening2004, author = {Keusgen, M. and Sch{\"o}ning, Michael Josef}, title = {Strategies for biosensoric detection of potential drugs in nature}, series = {Biomedizinische Technik. 49 (2004), H. 2}, journal = {Biomedizinische Technik. 49 (2004), H. 2}, isbn = {0932-4666}, pages = {1004 -- 1005}, year = {2004}, language = {en} } @article{SelmerScottNaeseretal.2004, author = {Selmer, Thorsten and Scott, Richard and N{\"a}ser, Ulrike and Friedrich, Peter}, title = {Stereochemistry of hydrogen removal from the 'unactivated' C-3 position of 4-hydroxybutyryl-CoA catalysed by 4-hydroxybutyryl-CoA dehydratase / Scott, R. ; N{\"a}ser, U. ; Friedrich, P. ; Selmer, T. ; Buckel, W. ; Golding, BT.}, series = {Chemical Communications : ChemCom (2004)}, journal = {Chemical Communications : ChemCom (2004)}, isbn = {1364-548X}, pages = {1210 -- 1211}, year = {2004}, language = {en} } @article{SchwarzerMuellerVieiradaSilva2004, author = {Schwarzer, Klemens and M{\"u}ller, C. and Vieira da Silva, E.}, title = {Solare Meerwasser-Entsalzungsanlagen mit mehrstufiger W{\"a}rmer{\"u}ckgewinnung / C. M{\"u}ller ; K. Schwarzer ; E. Vieira da Silva ...}, series = {14. Symposium Thermische Solarenergie : 12. bis 14. Mai, 2004, Kloster Banz / [Veranst.: OTTI Energie-Kolleg]}, journal = {14. Symposium Thermische Solarenergie : 12. bis 14. Mai, 2004, Kloster Banz / [Veranst.: OTTI Energie-Kolleg]}, publisher = {Ostbayerisches Technologie-Transfer-Institut}, address = {Regensburg}, isbn = {3-934681-33-6}, pages = {154 -- 159}, year = {2004}, language = {en} } @article{SchwarzerMuellerMertes2004, author = {Schwarzer, Klemens and M{\"u}ller, C. and Mertes, C.}, title = {Solar thermal desalination systems with multi-layer heat recovery / C. M{\"u}ller ; K. Schwarzer ; C. Mertes ...}, series = {Proceedings / organised by: ISES Europe ... [Ed.: Deutsche Gesellschaft f{\"u}r Sonnenenergie e.V. - DGS, Munich ; PSE GmbH - Forschung Entwicklung Marketing, Freiburg]. - Vol 1}, journal = {Proceedings / organised by: ISES Europe ... [Ed.: Deutsche Gesellschaft f{\"u}r Sonnenenergie e.V. - DGS, Munich ; PSE GmbH - Forschung Entwicklung Marketing, Freiburg]. - Vol 1}, publisher = {PSE}, address = {Freiburg [Breisgau]}, isbn = {3-9809656-1-9}, pages = {1-647-1-652}, year = {2004}, language = {en} } @article{PrumeGerberKuegeleretal.2004, author = {Prume, Klaus and Gerber, Peter and K{\"u}geler, Carsten and Roelofs, Andreas}, title = {Simulation and measurements of the piezoelectric properties response (d33) of piezoelectric layered thin film structures influenced by the top-electrode size / Prume, K. ; Gerber, P. ; K{\"u}geler, C. ; Roelofs, A. ; B{\"o}ttger, U. ; Waser, R. ; Schmitz-Kempen,}, isbn = {0-7803-8410-5}, pages = {7 -- 10}, year = {2004}, language = {en} }