@article{YoshinobuMiyamotoWerneretal.2017, author = {Yoshinobu, Tatsuo and Miyamoto, Ko-ichiro and Werner, Frederik and Poghossian, Arshak and Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Light-addressable potentiometric sensors for quantitative spatial imaging of chemical species}, series = {Annual Review of Analytical Chemistry}, volume = {10}, journal = {Annual Review of Analytical Chemistry}, publisher = {Annual Reviews}, address = {Palo Alto, Calif.}, issn = {1936-1327}, doi = {10.1146/annurev-anchem-061516-045158}, pages = {225 -- 246}, year = {2017}, abstract = {A light-addressable potentiometric sensor (LAPS) is a semiconductor-based chemical sensor, in which a measurement site on the sensing surface is defined by illumination. This light addressability can be applied to visualize the spatial distribution of pH or the concentration of a specific chemical species, with potential applications in the fields of chemistry, materials science, biology, and medicine. In this review, the features of this chemical imaging sensor technology are compared with those of other technologies. Instrumentation, principles of operation, and various measurement modes of chemical imaging sensor systems are described. The review discusses and summarizes state-of-the-art technologies, especially with regard to the spatial resolution and measurement speed; for example, a high spatial resolution in a submicron range and a readout speed in the range of several tens of thousands of pixels per second have been achieved with the LAPS. The possibility of combining this technology with microfluidic devices and other potential future developments are discussed.}, language = {en} } @article{YoshinobuEckenPoghossianetal.2001, author = {Yoshinobu, T. and Ecken, H. and Poghossian, Arshak and Simonis, A. and Iwasaki, H. and L{\"u}th, H. and Sch{\"o}ning, Michael Josef}, title = {Constant-current-mode LAPS (CLAPS) for the detection of penicillin}, series = {Electroanalysis. 13 (2001), H. 8-9}, journal = {Electroanalysis. 13 (2001), H. 8-9}, isbn = {1040-0397}, pages = {733 -- 736}, year = {2001}, language = {en} } @article{YoshinobuEckenPoghossianetal.2001, author = {Yoshinobu, T. and Ecken, H. and Poghossian, Arshak and L{\"u}th, H. and Iwasaki, H. and Sch{\"o}ning, Michael Josef}, title = {Alternative sensor materials for light-addressable potentiometric sensors}, series = {Sensors and Actuators B. 76 (2001), H. 1-3}, journal = {Sensors and Actuators B. 76 (2001), H. 1-3}, isbn = {0925-4005}, pages = {388 -- 392}, year = {2001}, language = {en} } @article{WuPoghossianBronderetal.2016, author = {Wu, Chunsheng and Poghossian, Arshak and Bronder, Thomas and Sch{\"o}ning, Michael Josef}, title = {Sensing of double-stranded DNA molecules by their intrinsic molecular charge using the light-addressable potentiometric sensor}, series = {Sensors and Actuators B: Chemical}, journal = {Sensors and Actuators B: Chemical}, number = {229}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2016.02.004}, pages = {506 -- 512}, year = {2016}, abstract = {A multi-spot light-addressable potentiometric sensor (LAPS), which belongs to the family of semiconductor field-effect devices, was applied for label-free detection of double-stranded deoxyribonucleic acid (dsDNA) molecules by their intrinsic molecular charge. To reduce the distance between the DNA charge and sensor surface and thus, to enhance the electrostatic coupling between the dsDNA molecules and the LAPS, the negatively charged dsDNA molecules were electrostatically adsorbed onto the gate surface of the LAPS covered with a positively charged weak polyelectrolyte layer of PAH (poly(allylamine hydrochloride)). The surface potential changes in each spot of the LAPS, induced by the layer-by-layer adsorption of a PAH/dsDNA bilayer, were recorded by means of photocurrent-voltage and constant-photocurrent measurements. In addition, the surface morphology of the gate surface before and after consecutive electrostatic adsorption of PAH and dsDNA layers was studied by atomic force microscopy measurements. Moreover, fluorescence microscopy was used to verify the successful adsorption of dsDNA molecules onto the PAH-modified LAPS surface. A high sensor signal of 25 mV was registered after adsorption of 10 nM dsDNA molecules. The lower detection limit is down to 0.1 nM dsDNA. The obtained results demonstrate that the PAH-modified LAPS device provides a convenient and rapid platform for the direct label-free electrical detection of in-solution hybridized dsDNA molecules.}, language = {en} } @article{WuBronderPoghossianetal.2015, author = {Wu, Chunsheng and Bronder, Thomas and Poghossian, Arshak and Werner, Frederik and Sch{\"o}ning, Michael Josef}, title = {Label-free detection of DNA using light-addressable potentiometric sensor modified with a positively charged polyelectrolyte layer}, series = {Nanoscale}, volume = {14}, journal = {Nanoscale}, number = {7}, publisher = {Royal Society of Chemistry (RSC)}, address = {Cambridge}, doi = {10.1039/C4NR07225A}, pages = {6143 -- 6150}, year = {2015}, abstract = {A multi-spot (16 spots) light-addressable potentiometric sensor (MLAPS) consisting of an Al-p-Si-SiO2 structure modified with a weak polyelectrolyte layer of PAH (poly(allylamine hydrochloride)) was applied for the label-free electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge for the first time. To achieve a preferentially flat orientation of DNA strands and thus, to reduce the distance between the DNA charge and MLAPS surface, the negatively charged probe single-stranded DNAs (ssDNA) were electrostatically adsorbed onto the positively charged PAH layer using a simple layer-by-layer (LbL) technique. In this way, more DNA charge can be positioned within the Debye length, yielding a higher sensor signal. The surface potential changes in each spot induced due to the surface modification steps (PAH adsorption, probe ssDNA immobilization, hybridization with complementary target DNA (cDNA), non-specific adsorption of mismatched ssDNA) were determined from the shifts of photocurrent-voltage curves along the voltage axis. A high sensor signal of 83 mV was registered after immobilization of probe ssDNA onto the PAH layer. The hybridization signal increases from 5 mV to 32 mV with increasing the concentration of cDNA from 0.1 nM to 5 μM. In contrast, a small signal of 5 mV was recorded in the case of non-specific adsorption of fully mismatched ssDNA (5 μM). The obtained results demonstrate the potential of the MLAPS in combination with the simple and rapid LbL immobilization technique as a promising platform for the future development of multi-spot light-addressable label-free DNA chips with direct electrical readout.}, language = {en} } @article{WuBronderPoghossianetal.2014, author = {Wu, Chunsheng and Bronder, Thomas and Poghossian, Arshak and Werner, Frederik and B{\"a}cker, Matthias and Sch{\"o}ning, Michael Josef}, title = {Label-free electrical detection of DNA with a multi-spot LAPS: First step towards light-addressable DNA chips}, series = {Physica status solidi A : Applications and materials science}, volume = {211}, journal = {Physica status solidi A : Applications and materials science}, number = {6}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-396X (E-Journal); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print)}, doi = {10.1002/pssa.201330442}, pages = {1423 -- 1428}, year = {2014}, abstract = {A multi-spot (4 × 4 spots) light-addressable potentiometric sensor (MLAPS) consisting of an Al-p-Si-SiO2 structure has been applied for the label-free electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge for the first time. Single-stranded probe ssDNA molecules (20 bases) were covalently immobilized onto the silanized SiO2 gate surface. The unspecific adsorption of mismatch ssDNA on the MLAPS gate surface was blocked by bovine serum albumin molecules. To reduce the screening effect and to achieve a high sensor signal, the measurements were performed in a low ionic-strength solution. The photocurrent-voltage (I-V) curves were simultaneously recorded on all 16 spots after each surface functionalization step. Large shifts of I-V curves of 25 mV were registered after the DNA immobilization and hybridization event. In contrast, a small potential shift (∼5 mV) was observed in case of mismatch ssDNA, revealing good specificity of the sensor. The obtained results demonstrate the potential of the MLAPS as promising transducer platform for the multi-spot label-free electrical detection of DNA molecules by their intrinsic molecular charge.}, language = {en} } @article{WendlandtKochBritzetal.2023, author = {Wendlandt, Tim and Koch, Claudia and Britz, Beate and Liedek, Anke and Schmidt, Nora and Werner, Stefan and Gleba, Yuri and Vahidpour, Farnoosh and Welden, Melanie and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Facile Purification and Use of Tobamoviral Nanocarriers for Antibody-Mediated Display of a Two-Enzyme System}, series = {Viruses}, volume = {9}, journal = {Viruses}, number = {15}, publisher = {MDPI}, address = {Basel}, issn = {1999-4915}, doi = {doi.org/10.3390/v15091951}, pages = {Artikel 1951}, year = {2023}, abstract = {Immunosorbent turnip vein clearing virus (TVCV) particles displaying the IgG-binding domains D and E of Staphylococcus aureus protein A (PA) on every coat protein (CP) subunit (TVCVPA) were purified from plants via optimized and new protocols. The latter used polyethylene glycol (PEG) raw precipitates, from which virions were selectively re-solubilized in reverse PEG concentration gradients. This procedure improved the integrity of both TVCVPA and the wild-type subgroup 3 tobamovirus. TVCVPA could be loaded with more than 500 IgGs per virion, which mediated the immunocapture of fluorescent dyes, GFP, and active enzymes. Bi-enzyme ensembles of cooperating glucose oxidase and horseradish peroxidase were tethered together on the TVCVPA carriers via a single antibody type, with one enzyme conjugated chemically to its Fc region, and the other one bound as a target, yielding synthetic multi-enzyme complexes. In microtiter plates, the TVCVPA-displayed sugar-sensing system possessed a considerably increased reusability upon repeated testing, compared to the IgG-bound enzyme pair in the absence of the virus. A high coverage of the viral adapters was also achieved on Ta2O5 sensor chip surfaces coated with a polyelectrolyte interlayer, as a prerequisite for durable TVCVPA-assisted electrochemical biosensing via modularly IgG-assembled sensor enzymes.}, language = {en} } @article{WagnerMarisAckermannetal.2007, author = {Wagner, Torsten and Maris, Rob J. and Ackermann, Hans-Josef and Otto, Ralph and Beging, Stefan and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Handheld measurement device for field-effect sensor structures: Practical evaluation and limitations}, series = {Sensors and Actuators B: Chemical . 127 (2007), H. 1}, journal = {Sensors and Actuators B: Chemical . 127 (2007), H. 1}, isbn = {0925-4005}, pages = {217 -- 223}, year = {2007}, language = {en} } @article{WagnerBegingRotteretal.2007, author = {Wagner, Torsten and Beging, Stefan and Rotter, L. and Poghossian, Arshak and Biselli, Manfred and Zang, Werner and Sch{\"o}ning, Michael Josef}, title = {Online-Messsysteme f{\"u}r die automatisierte Charakterisierung von feldeffektbasierten Biosensoren}, series = {8. Dresdner Sensor-Symposium : Sensoren f{\"u}r Umwelt, Klima und Sicherheit, Biosensoren und Biosysteme, Sensoren und Sensorsysteme f{\"u}r die Prozesstechnik, Trends in der Sensortechnik, Materialentwicklung f{\"u}r die Sensorik; 8. Dresdner Sensor-Symposium, 10. - 12. Dezember 2007, Dresden / Gerald Gerlach ... (Hg.)}, journal = {8. Dresdner Sensor-Symposium : Sensoren f{\"u}r Umwelt, Klima und Sicherheit, Biosensoren und Biosysteme, Sensoren und Sensorsysteme f{\"u}r die Prozesstechnik, Trends in der Sensortechnik, Materialentwicklung f{\"u}r die Sensorik; 8. Dresdner Sensor-Symposium, 10. - 12. Dezember 2007, Dresden / Gerald Gerlach ... (Hg.)}, publisher = {TUDpress, Verl. der Wissenschaften}, address = {Dresden}, isbn = {978-3-940046-45-1}, pages = {257 -- 260}, year = {2007}, language = {de} } @article{TurekKeusgenPoghossianetal.2008, author = {Turek, M. and Keusgen, M. and Poghossian, Arshak and Mulchandani, A. and Wang, J. and Sch{\"o}ning, Michael Josef}, title = {Enzyme-modified electrolyte-insulator-semiconductor sensors}, series = {Journal of Contemporary Physics. 43 (2008), H. 2}, journal = {Journal of Contemporary Physics. 43 (2008), H. 2}, isbn = {1934-9378}, pages = {82 -- 85}, year = {2008}, language = {en} } @article{ThustPoghossianSchoeningetal.1999, author = {Thust, M. and Poghossian, Arshak and Sch{\"o}ning, Michael Josef and Naser, S. and M{\"u}ller-Veggian, Mattea and Kordos, P. and L{\"u}th, H.}, title = {Crosssensitivity of a capacitive penicillin sensor combined with a diffusion barrier}, series = {Proceedings : The Hague, The Netherlands, September 12 - 15, 1999 / [ed. by M. Bartek]. Vol 1.}, journal = {Proceedings : The Hague, The Netherlands, September 12 - 15, 1999 / [ed. by M. Bartek]. Vol 1.}, address = {The Hague, The Netherlands}, isbn = {90-76699-02-X}, pages = {573 -- 576}, year = {1999}, language = {en} } @article{ThustPoghossianSchoeningetal.1999, author = {Thust, M. and Poghossian, Arshak and Sch{\"o}ning, Michael Josef and Naser, S. and M{\"u}ller-Veggian, Mattea and Kordos, P. and L{\"u}th, H.}, title = {Cross-sensitivity of a capacitive penicillin sensor combined with a diffusion barrier}, series = {Proceedings : The Hague, The Netherlands, September 12 - 15, 1999 / [ed. by M. Bartek]. - Vol 1.}, journal = {Proceedings : The Hague, The Netherlands, September 12 - 15, 1999 / [ed. by M. Bartek]. - Vol 1.}, address = {The Hague, The Netherlands}, isbn = {90-76699-02-X}, pages = {573 -- 576}, year = {1999}, language = {en} } @article{SpelthahnPoghossianSchoening2009, author = {Spelthahn, Heiko and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Self-aligned nanogaps and nanochannels via conventional photolithography and pattern-size reduction technique}, series = {Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI}, journal = {Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI}, isbn = {0013-4686}, pages = {6010 -- 6014}, year = {2009}, language = {en} } @article{SiqueiraBaeckerPoghossianetal.2010, author = {Siqueira, Jos{\´e} R. Jr. and B{\"a}cker, Matthias and Poghossian, Arshak and Zucolotto, Valtencir and Oliveira, Osvaldo N. Jr. and Sch{\"o}ning, Michael Josef}, title = {Associating biosensing properties with the morphological structure of multilayers containing carbon nanotubes on field-effect devices}, series = {Physica status solidi (a). 207 (2010), H. 4}, journal = {Physica status solidi (a). 207 (2010), H. 4}, isbn = {1862-6300}, pages = {781 -- 786}, year = {2010}, language = {en} } @article{SiqueiraAbouzarPoghossianetal.2009, author = {Siqueira, Jos{\´e} R. Jr. and Abouzar, Maryam H. and Poghossian, Arshak and Zucolotto, Valtencir and Oliveira, Osvaldo N. Jr. and Sch{\"o}ning, Michael Josef}, title = {Penicillin biosensor based on a capacitive field-effect structure functionalized with a dendrimer/carbon nanotube multilayer}, series = {Biosensors and Bioelectronics. 25 (2009), H. 2}, journal = {Biosensors and Bioelectronics. 25 (2009), H. 2}, isbn = {0956-5663}, pages = {497 -- 501}, year = {2009}, language = {en} } @article{SiqueiraAbouzarBaeckeretal.2009, author = {Siqueira, Jos{\´e} R. Jr. and Abouzar, Maryam H. and B{\"a}cker, Matthias and Zucolotto, Valtencir and Poghossian, Arshak and Oliveira, Osvaldo N. Jr. and Sch{\"o}ning, Michael Josef}, title = {Carbon nanotubes in nanostructured films: Potential application as amperometric and potentiometric field-effect (bio-)chemical sensors}, series = {physica status solidi (a) . 206 (2009), H. 3}, journal = {physica status solidi (a) . 206 (2009), H. 3}, publisher = {Wiley}, address = {Weinheim}, isbn = {1862-6319}, pages = {462 -- 467}, year = {2009}, language = {en} } @article{SiqueiraWernerBaeckeretal.2009, author = {Siqueira, Jose R. and Werner, Frederik and B{\"a}cker, Matthias and Poghossian, Arshak and Zucolotto, Valtencir and Oliveira, Osvaldo N. Jr. and Sch{\"o}ning, Michael Josef}, title = {Layer-by-Layer Assembly of Carbon Nanotubes Incorporated in Light-Addressable Potentiometric Sensors}, series = {Journal of Physical Chemistry C. 113 (2009), H. 33}, journal = {Journal of Physical Chemistry C. 113 (2009), H. 33}, publisher = {American Chemical Society}, address = {Washington, DC}, isbn = {1932-7455}, pages = {14765 -- 14770}, year = {2009}, language = {en} } @article{SiqueiraMakiPaulovichetal.2010, author = {Siqueira, Jose R. and Maki, Rafael M. and Paulovich, Fernando V. and Werner, Frederik and Poghossian, Arshak and Oliveira, Maria C. F. de and Zucolotto, Valtencir and Oliveira, Osvaldo N. Jr. and Sch{\"o}ning, Michael Josef}, title = {Use of Information Visualization Methods Eliminating Cross Talk in Multiple Sensing Units Investigated for a Light-Addressable Potentiometric Sensor}, series = {Analytical Chemistry (2010)}, journal = {Analytical Chemistry (2010)}, isbn = {0003-2700}, pages = {61 -- 65}, year = {2010}, language = {en} } @article{SchoeningPoghossianYoshinobuetal.2001, author = {Sch{\"o}ning, Michael Josef and Poghossian, Arshak and Yoshinobu, Tatsuo and L{\"u}th, Hans}, title = {Semiconductor-based field-effect structures for chemical sensing}, pages = {188 -- 198}, year = {2001}, language = {en} } @article{SchoeningPoghossianSchultze2003, author = {Sch{\"o}ning, Michael Josef and Poghossian, Arshak and Schultze, Joachim W.}, title = {Measuring seven parameters by two ISFET modules in a microcell set-up}, series = {Int. Journal of Computational Engineering Science. 4 (2003), H. 2}, journal = {Int. Journal of Computational Engineering Science. 4 (2003), H. 2}, isbn = {1465-8763}, pages = {257 -- 260}, year = {2003}, language = {en} }