@article{SchwagerFleschSchwarzboezletal.2022, author = {Schwager, Christian and Flesch, Robert and Schwarzb{\"o}zl, Peter and Herrmann, Ulf and Teixeira Boura, Cristiano Jos{\´e}}, title = {Advanced two phase flow model for transient molten salt receiver system simulation}, series = {Solar Energy}, volume = {232}, journal = {Solar Energy}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0038-092X (print)}, doi = {10.1016/j.solener.2021.12.065}, pages = {362 -- 375}, year = {2022}, abstract = {In order to realistically predict and optimize the actual performance of a concentrating solar power (CSP) plant sophisticated simulation models and methods are required. This paper presents a detailed dynamic simulation model for a Molten Salt Solar Tower (MST) system, which is capable of simulating transient operation including detailed startup and shutdown procedures including drainage and refill. For appropriate representation of the transient behavior of the receiver as well as replication of local bulk and surface temperatures a discretized receiver model based on a novel homogeneous two-phase (2P) flow modelling approach is implemented in Modelica Dymola®. This allows for reasonable representation of the very different hydraulic and thermal properties of molten salt versus air as well as the transition between both. This dynamic 2P receiver model is embedded in a comprehensive one-dimensional model of a commercial scale MST system and coupled with a transient receiver flux density distribution from raytracing based heliostat field simulation. This enables for detailed process prediction with reasonable computational effort, while providing data such as local salt film and wall temperatures, realistic control behavior as well as net performance of the overall system. Besides a model description, this paper presents some results of a validation as well as the simulation of a complete startup procedure. Finally, a study on numerical simulation performance and grid dependencies is presented and discussed.}, language = {en} } @article{GrossTimmer1998, author = {Groß, Rolf Fritz and Timmer, H.}, title = {Energetische und betriebswirtschaftliche Bewertung von K{\"u}hlsystemen f{\"u}r K{\"u}hllager}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {49}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {9}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {74 -- 77}, year = {1998}, language = {de} } @article{ThulfautGross2000, author = {Thulfaut, Christian and Groß, Rolf Fritz}, title = {Experimentelle Untersuchung der Luftstromvermischung in Hybridzellenk{\"u}hlt{\"u}rmen}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {51}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {8}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {48 -- 49}, year = {2000}, abstract = {Zwangsbel{\"u}ftete Nassk{\"u}hlt{\"u}rme haben im Gegensatz zur Trockenk{\"u}hlung bei naßkaltem Wetter Nebelschwaden zur Folge. Dagegen ist bei Naßk{\"u}hlung die spezifische K{\"u}hlleistung durch abgef{\"u}hrte Kondensationsw{\"a}rme h{\"o}her als bei der Trockenk{\"u}hlung. Hybridzellenk{\"u}hlt{\"u}rme kombinieren beide Methoden, so daß ein Mischstrom beider Abluftstr{\"o}me die Wasserdampf-S{\"a}ttigungsgrenze nicht {\"u}berschreitet. Durch das Mischungsverh{\"a}ltnis kann man den gew{\"u}nschten S{\"a}ttigungsgrad einstellen. Je dichter dieser an der S{\"a}ttigungsgrenze liegt, desto h{\"o}her ist die K{\"u}hlleistung. Der von unten zugef{\"u}hrte Luftstrom der Naßk{\"u}hlung und der seitlich zugef{\"u}hrte trockene Abluftstrom m{\"u}ssen sehr gut durchmischt werden, um {\"u}ber den gesamten Austrittsquerschnitt des K{\"u}hlturms die S{\"a}ttigungsgrenze nicht zu {\"u}berschreiten. In einem maßstabsgerechten Modell wurde der Mischungsgrad mit und ohne Einbauten untersucht. {\"U}ber ein Raster von 10 mal 10 Punkten wurde die {\"o}rtliche Temperaturverteilung ermittelt. W{\"a}rmebilanzen ergeben dann die Mischungsg{\"u}te in einer Ebene oberhalb der Zellenkrone. W{\"a}hrend ohne Mischeinbauten der Trockenluftanteil in der Mitte des Querschnitts bei unter 15 \% liegt erh{\"o}hen Einbauten den Trockenluftanteil auf 30 \% bis {\"u}ber 40 \%. Dabei wurde die Trockenluft auf jeder K{\"u}hlturmseite durch 4 konisch zulaufende, unten offene und oben geschlitzte Einbauten kanalisiert. Die Nassluft wurde durch eine im Querschnitt dreieckige Rinne in Richtung der Trockenluftausl{\"a}sse umgelenkt. Im Raster leicht zu lokalisierende Abweichungen vom gew{\"u}nschten Mittelwert zeigen Potential f{\"u}r die weitere Verbesserung der Einbauten.}, language = {de} } @article{GrossBergerGross2003, author = {Groß, Rolf Fritz and Berger, J. and Groß, H.}, title = {Geb{\"a}udeautomation - Betriebsdatenerfassung und Geb{\"a}udeleittechnik im Klartext}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {54}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {2}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {81}, year = {2003}, language = {de} } @article{GrossBerger2005, author = {Groß, Rolf Fritz and Berger, J.}, title = {Quo Vadis - Ausblick in die Geb{\"a}udeleittechnik der Zukunft}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {56}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {1}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {39 -- 41}, year = {2005}, abstract = {Auf dem Weg zum vernetzten Haus stoßen Hersteller und Planer, insbesondere im privaten Wohnungsbau, zur Zeit noch auf erhebliche Widerst{\"a}nde bei der Durchdringung des Marktes.}, language = {de} } @article{PeereBlanke2022, author = {Peere, Wouter and Blanke, Tobias}, title = {GHEtool: An open-source tool for borefield sizing in Python}, series = {Journal of Open Source Software}, volume = {7}, journal = {Journal of Open Source Software}, number = {76}, editor = {Vernon, Chris}, issn = {2475-9066}, doi = {10.21105/joss.04406}, pages = {1 -- 4, 4406}, year = {2022}, abstract = {GHEtool is a Python package that contains all the functionalities needed to deal with borefield design. It is developed for both researchers and practitioners. The core of this package is the automated sizing of borefield under different conditions. The sizing of a borefield is typically slow due to the high complexity of the mathematical background. Because this tool has a lot of precalculated data, GHEtool can size a borefield in the order of tenths of milliseconds. This sizing typically takes the order of minutes. Therefore, this tool is suited for being implemented in typical workflows where iterations are required. GHEtool also comes with a graphical user interface (GUI). This GUI is prebuilt as an exe-file because this provides access to all the functionalities without coding. A setup to install the GUI at the user-defined place is also implemented and available at: https://www.mech.kuleuven.be/en/tme/research/thermal_systems/tools/ghetool.}, language = {en} } @article{GorzalkaSchmiedtSchorn2021, author = {Gorzalka, Philip and Schmiedt, Jacob Estevam and Schorn, Christian}, title = {Automated Generation of an Energy Simulation Model for an Existing Building from UAV Imagery}, series = {Buildings}, volume = {11}, journal = {Buildings}, number = {9}, publisher = {MDPI}, address = {Basel}, issn = {2075-5309}, doi = {10.3390/buildings11090380}, pages = {15 Seiten}, year = {2021}, abstract = {An approach to automatically generate a dynamic energy simulation model in Modelica for a single existing building is presented. It aims at collecting data about the status quo in the preparation of energy retrofits with low effort and costs. The proposed method starts from a polygon model of the outer building envelope obtained from photogrammetrically generated point clouds. The open-source tools TEASER and AixLib are used for data enrichment and model generation. A case study was conducted on a single-family house. The resulting model can accurately reproduce the internal air temperatures during synthetical heating up and cooling down. Modelled and measured whole building heat transfer coefficients (HTC) agree within a 12\% range. A sensitivity analysis emphasises the importance of accurate window characterisations and justifies the use of a very simplified interior geometry. Uncertainties arising from the use of archetype U-values are estimated by comparing different typologies, with best- and worst-case estimates showing differences in pre-retrofit heat demand of about ±20\% to the average; however, as the assumptions made are permitted by some national standards, the method is already close to practical applicability and opens up a path to quickly estimate possible financial and energy savings after refurbishment.}, language = {en} } @article{HagenkampBlankeDoering2021, author = {Hagenkamp, Markus and Blanke, Tobias and D{\"o}ring, Bernd}, title = {Thermoelectric building temperature control: a potential assessment}, series = {International Journal of Energy and Environmental Engineering}, volume = {13}, journal = {International Journal of Energy and Environmental Engineering}, publisher = {Springer}, address = {Berlin}, doi = {10.1007/s40095-021-00424-x}, pages = {241 -- 254}, year = {2021}, abstract = {This study focuses on thermoelectric elements (TEE) as an alternative for room temperature control. TEE are semi-conductor devices that can provide heating and cooling via a heat pump effect without direct noise emissions and no refrigerant use. An efficiency evaluation of the optimal operating mode is carried out for different numbers of TEE, ambient temperatures, and heating loads. The influence of an additional heat recovery unit on system efficiency and an unevenly distributed heating demand are examined. The results show that TEE can provide heat at a coefficient of performance (COP) greater than one especially for small heating demands and high ambient temperatures. The efficiency increases with the number of elements in the system and is subject to economies of scale. The best COP exceeds six at optimal operating conditions. An additional heat recovery unit proves beneficial for low ambient temperatures and systems with few TEE. It makes COPs above one possible at ambient temperatures below 0 ∘C. The effect increases efficiency by maximal 0.81 (from 1.90 to 2.71) at ambient temperature 5 K below room temperature and heating demand Q˙h=100W but is subject to diseconomies of scale. Thermoelectric technology is a valuable option for electricity-based heat supply and can provide cooling and ventilation functions. A careful system design as well as an additional heat recovery unit significantly benefits the performance. This makes TEE superior to direct current heating systems and competitive to heat pumps for small scale applications with focus on avoiding noise and harmful refrigerants.}, language = {en} } @article{BlankeRegerDoeringetal.2021, author = {Blanke, Tobias and Reger, Vitali and D{\"o}ring, Bernd and G{\"o}ttsche, Joachim and Kuhnhenne, Markus}, title = {Koaxiale Stahlenergiepf{\"a}hle}, series = {Stahlbau}, volume = {90. 2021}, journal = {Stahlbau}, number = {6}, publisher = {Wiley}, address = {Weinheim}, pages = {417 -- 424}, year = {2021}, abstract = {Ein entscheidender Teil der Energiewende ist die W{\"a}rmewende im Geb{\"a}udesektor. Ein Schl{\"u}sselelement sind hier W{\"a}rmepumpen. Diese ben{\"o}tigen eine W{\"a}rmequelle, der sie Energie entziehen k{\"o}nnen, um sie auf ein h{\"o}heres Temperaturniveau zu transformieren. Diese W{\"a}rmequelle kann bspw. das Erdreich sein, dessen W{\"a}rme durch Erdsonden erschlossen werden kann. In diesem Beitrag werden in Stahlpf{\"a}hle integrierte Koaxialsonden mit dem Stand der Technik von Erdsonden gleichen Durchmessers bez{\"u}glich ihrer thermischen Leistungsmerkmale verglichen. Die Stahlenergiepf{\"a}hle bieten neben der W{\"a}rmegewinnung weitere Vorteile, da sie auch eine statische Funktion {\"u}bernehmen und r{\"u}ckstandsfrei zur{\"u}ckgebaut werden k{\"o}nnen. Es werden analytische und numerische Berechnungen vorgestellt, um die thermischen Potenziale beider Systeme zu vergleichen. Außerdem wird ein Testaufbau gezeigt, bei dem Stahlenergiepf{\"a}hle in zwei verschiedenen L{\"a}ngen mit vorhandenen g{\"a}ngigen Erdsonden verglichen werden k{\"o}nnen. Die Berechnungen zeigen einen deutlichen thermischen Mehrertrag zwischen 26 \% und 148 \% der Stahlenergiepf{\"a}hle gegen{\"u}ber dem Stand der Technik abh{\"a}ngig vom Erdreich. Die Messergebnisse zeigen einen thermischen Mehrertrag von {\"u}ber 100 \%. Es l{\"a}sst sich also signifikante Erdsondenl{\"a}nge einsparen. Dabei ist zu beachten, dass sich damit der thermisch genutzte Bereich des Erdreichs reduziert, wodurch die thermische Regeneration und/oder das Langzeitverhalten des Erdreichs an Bedeutung gewinnt.}, language = {de} } @article{HerrmannSchwarzenbartDittmannGabrieletal.2019, author = {Herrmann, Ulf and Schwarzenbart, Marc and Dittmann-Gabriel, S{\"o}ren and May, Martin}, title = {Hochtemperatur-W{\"a}rmespeicher f{\"u}r die Strom- und W{\"a}rmewende}, series = {Solarzeitalter : Politik, Kultur und {\"O}konomie erneuerbarer Energien}, volume = {31}, journal = {Solarzeitalter : Politik, Kultur und {\"O}konomie erneuerbarer Energien}, number = {2}, issn = {0937-3802}, pages = {18 -- 23}, year = {2019}, language = {de} } @article{MeyerHaenelBeehetal.2020, author = {Meyer, S. and H{\"a}nel, Matthias and Beeh, B. and Dittmann-Gabriel, S{\"o}ren and Dluhosch, R. and May, Martin and Herrmann, Ulf and [und 5 weitere],}, title = {Multifunktionaler thermischer Stromspeicher f{\"u}r die Strom- und W{\"a}rmeversorgung der Industrie von morgen}, series = {ETG Journal / Energietechnische Gesellschaft im VDE (ETG)}, volume = {2020}, journal = {ETG Journal / Energietechnische Gesellschaft im VDE (ETG)}, number = {1}, issn = {2625-9907}, pages = {6 -- 9}, year = {2020}, language = {de} } @article{BlankeHagenkampDoeringetal.2021, author = {Blanke, Tobias and Hagenkamp, Markus and D{\"o}ring, Bernd and G{\"o}ttsche, Joachim and Reger, Vitali and Kuhnhenne, Markus}, title = {Net-exergetic, hydraulic and thermal optimization of coaxial heat exchangers using fixed flow conditions instead of fixed flow rates}, series = {Geothermal Energy}, volume = {9}, journal = {Geothermal Energy}, number = {Article number: 19}, publisher = {Springer}, address = {Berlin}, issn = {2195-9706}, doi = {10.1186/s40517-021-00201-3}, pages = {23 Seiten}, year = {2021}, abstract = {Previous studies optimized the dimensions of coaxial heat exchangers using constant mass fow rates as a boundary condition. They show a thermal optimal circular ring width of nearly zero. Hydraulically optimal is an inner to outer pipe radius ratio of 0.65 for turbulent and 0.68 for laminar fow types. In contrast, in this study, fow conditions in the circular ring are kept constant (a set of fxed Reynolds numbers) during optimization. This approach ensures fxed fow conditions and prevents inappropriately high or low mass fow rates. The optimization is carried out for three objectives: Maximum energy gain, minimum hydraulic efort and eventually optimum net-exergy balance. The optimization changes the inner pipe radius and mass fow rate but not the Reynolds number of the circular ring. The thermal calculations base on Hellstr{\"o}m's borehole resistance and the hydraulic optimization on individually calculated linear loss of head coefcients. Increasing the inner pipe radius results in decreased hydraulic losses in the inner pipe but increased losses in the circular ring. The net-exergy diference is a key performance indicator and combines thermal and hydraulic calculations. It is the difference between thermal exergy fux and hydraulic efort. The Reynolds number in the circular ring is instead of the mass fow rate constant during all optimizations. The result from a thermal perspective is an optimal width of the circular ring of nearly zero. The hydraulically optimal inner pipe radius is 54\% of the outer pipe radius for laminar fow and 60\% for turbulent fow scenarios. Net-exergetic optimization shows a predominant infuence of hydraulic losses, especially for small temperature gains. The exact result depends on the earth's thermal properties and the fow type. Conclusively, coaxial geothermal probes' design should focus on the hydraulic optimum and take the thermal optimum as a secondary criterion due to the dominating hydraulics.}, language = {en} } @article{GoettscheAlexopoulosDuemmleretal.2019, author = {G{\"o}ttsche, Joachim and Alexopoulos, Spiros and D{\"u}mmler, Andreas and Maddineni, S. K.}, title = {Multi-Mirror Array Calculations With Optical Error}, pages = {1 -- 6}, year = {2019}, abstract = {The optical performance of a 2-axis solar concentrator was simulated with the COMSOL Multiphysics® software. The concentrator consists of a mirror array, which was created using the application builder. The mirror facets are preconfigured to form a focal point. During tracking all mirrors are moved simultaneously in a coupled mode by 2 motors in two axes, in order to keep the system in focus with the moving sun. Optical errors on each reflecting surface were implemented in combination with the solar angular cone of ± 4.65 mrad. As a result, the intercept factor of solar radiation that is available to the receiver was calculated as a function of the transversal and longitudinal angles of incidence. In addition, the intensity distribution on the receiver plane was calculated as a function of the incidence angles.}, language = {en} } @article{ElMoussaouiTalbiAtmaneetal.2020, author = {El Moussaoui, Noureddine and Talbi, Sofian and Atmane, Ilyas and Kassmi, Khalil and Schwarzer, Klemens and Chayeb, Hamid and Bachiri, Najib}, title = {Feasibility of a new design of a Parabolic Trough Solar Thermal Cooker (PSTC)}, series = {Solar Energy}, volume = {201}, journal = {Solar Energy}, number = {Vol. 201 (May 2020)}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0038-092X}, doi = {10.1016/j.solener.2020.03.079}, pages = {866 -- 871}, year = {2020}, abstract = {In this article, we describe the structure, the functioning, and the tests of parabolic trough solar thermal cooker (PSTC). This oven is designed to meet the needs of rural residents, including Urban, which requires stable cooking temperatures above 200 °C. The cooking by this cooker is based on the concentration of the sun's rays on a glass vacuum tube and heating of the oil circulate in a big tube, located inside the glass tube. Through two small tubes, associated with large tube, the heated oil, rise and heats the pot of cooking pot containing the food to be cooked (capacity of 5 kg). This cooker is designed in Germany and extensively tested in Morocco for use by the inhabitants who use wood from forests. During a sunny day, having a maximum solar radiation around 720 W/m2 and temperature ambient around 26 °C, maximum temperatures recorded of the small tube, the large tube and the center of the pot are respectively: 370 °C, 270 °C and 260 °C. The cooking process with food at high (fries, ..), we show that the cooking oil temperature rises to 200 °C, after 1 h of heating, the cooking is done at a temperature of 120 °C for 20 min. These temperatures are practically stable following variations and decreases in the intensity of irradiance during the day. The comparison of these results with those of the literature shows an improvement of 30-50 \% on the maximum value of the temperature with a heat storage that could reach 60 min of autonomy. All the results obtained show the good functioning of the PSTC and the feasibility of cooking food at high temperature (>200 °C).}, language = {en} } @article{SattlerRoegerSchwarzboezletal.2020, author = {Sattler, Johannes, Christoph and R{\"o}ger, Marc and Schwarzb{\"o}zl, Peter and Buck, Reiner and Macke, Ansgar and Raeder, Christian and G{\"o}ttsche, Joachim}, title = {Review of heliostat calibration and tracking control methods}, series = {Solar Energy}, volume = {207}, journal = {Solar Energy}, publisher = {Elsevier}, address = {Amsterdam}, doi = {10.1016/j.solener.2020.06.030}, pages = {110 -- 132}, year = {2020}, abstract = {Large scale central receiver systems typically deploy between thousands to more than a hundred thousand heliostats. During solar operation, each heliostat is aligned individually in such a way that the overall surface normal bisects the angle between the sun's position and the aim point coordinate on the receiver. Due to various tracking error sources, achieving accurate alignment ≤1 mrad for all the heliostats with respect to the aim points on the receiver without a calibration system can be regarded as unrealistic. Therefore, a calibration system is necessary not only to improve the aiming accuracy for achieving desired flux distributions but also to reduce or eliminate spillage. An overview of current larger-scale central receiver systems (CRS), tracking error sources and the basic requirements of an ideal calibration system is presented. Leading up to the main topic, a description of general and specific terms on the topics heliostat calibration and tracking control clarifies the terminology used in this work. Various figures illustrate the signal flows along various typical components as well as the corresponding monitoring or measuring devices that indicate or measure along the signal (or effect) chain. The numerous calibration systems are described in detail and classified in groups. Two tables allow the juxtaposition of the calibration methods for a better comparison. In an assessment, the advantages and disadvantages of individual calibration methods are presented.}, language = {en} } @article{RegerKuhnhenneEbbertetal.2020, author = {Reger, Vitali and Kuhnhenne, Markus and Ebbert, Thiemo and Hachul, Helmut and Blanke, Tobias and D{\"o}ring, Bernd}, title = {Nutzung erneuerbarer Energien durch thermische Aktivierung von Komponenten aus Stahl}, series = {Stahlbau}, volume = {2020}, journal = {Stahlbau}, number = {Volume 89, Issue 6512-519}, publisher = {Ernst \& Sohn}, address = {Berlin}, issn = {1437-1049}, doi = {10.1002/stab.202000031}, pages = {512 -- 519}, year = {2020}, abstract = {Die Versorgung von Neubauten soll m{\"o}glichst weitgehend unabh{\"a}ngig von fossilen Energietr{\"a}gern erfolgen. Erneuerbare Energien spielen daf{\"u}r eine gewichtige Rolle. Eine gute M{\"o}glichkeit, erneuerbare Energien ohne viel zus{\"a}tzlichen Aufwand nutzbar zu machen, ist, bereits vorhandenen Komponenten im Geb{\"a}ude zus{\"a}tzliche Funktionen zu geben. Hier kann bspw. die Fassade oder das Dach solarthermisch aktiviert oder durch Fotovoltaikmodule erg{\"a}nzt werden. Auch Tiefgr{\"u}ndungen k{\"o}nnen neben der statischen Funktion noch eine geothermische Funktion zur Aufnahme oder Abgabe von W{\"a}rme erhalten. Neben der Erzeugung bietet sich auch f{\"u}r die Verteilung der W{\"a}rme oder K{\"a}lte im Geb{\"a}ude die Integration in Bauteile an. Hier kann bspw. der Boden durch eine Fußbodenheizung oder die Decke durch Deckenstrahlplatten aktiviert werden. Im Rahmen der Ver{\"o}ffentlichung wird auf die thermische Aktivierung von Stahlkomponenten eingegangen. Es wird eine L{\"o}sung vorgestellt, die vorgeh{\"a}ngte hinterl{\"u}ftete Stahlfassade (VHF) solarthermisch zu aktivieren. Außerdem werden zwei M{\"o}glichkeiten zur geothermischen Aktivierung von Tiefgr{\"u}ndungen mittels Stahlpf{\"a}hlen gezeigt. Zuletzt wird ein System zur thermischen Aktivierung von Stahltrapezprofilen an der Decke erl{\"a}utert, welches W{\"a}rme zuf{\"u}hren oder bei Bedarf abf{\"u}hren kann.}, language = {de} } @article{HerrmannSchwarzenbartDittmannGabriel2019, author = {Herrmann, Ulf and Schwarzenbart, Marc and Dittmann-Gabriel, S{\"o}ren}, title = {Speicher statt Kohle. Integration thermischer Stromspeicher in vorhandene Kraftwerksstandorte}, series = {BWK : Das Energie-Fachmagazin}, volume = {71}, journal = {BWK : Das Energie-Fachmagazin}, number = {4}, publisher = {Springer-VDI-Verl.}, address = {D{\"u}sseldorf}, issn = {1436-4883}, pages = {42 -- 45}, year = {2019}, language = {de} } @article{WoliszSchuetzBlankeetal.2017, author = {Wolisz, Henryk and Sch{\"u}tz, Thomas and Blanke, Tobias and Hagenkamp, Markus and Kohrn, Markus and Wesseling, Mark and M{\"u}ller, Dirk}, title = {Cost optimal sizing of smart buildings' energy system components considering changing end-consumer electricity markets}, series = {Energy}, volume = {137}, journal = {Energy}, publisher = {Elsevier}, address = {Amsterdam}, doi = {10.1016/j.energy.2017.06.025}, pages = {715 -- 728}, year = {2017}, language = {en} } @article{RegerKuhnhenneHachuletal.2019, author = {Reger, Vitali and Kuhnhenne, Markus and Hachul, Helmut and D{\"o}ring, Bernd and Blanke, Tobias and G{\"o}ttsche, Joachim}, title = {Plusenergiegeb{\"a}ude 2.0 in Stahlleichtbauweise}, series = {Stahlbau}, volume = {88}, journal = {Stahlbau}, number = {6}, publisher = {Ernst \& Sohn}, address = {Berlin}, issn = {1437-1049 (E-journal), 0038-9145 (print)}, doi = {10.1002/stab.201900034}, pages = {522 -- 528}, year = {2019}, language = {de} } @article{PuppeGiulianoFrantzetal.2018, author = {Puppe, Michael and Giuliano, Stefano and Frantz, Cathy and Uhlig, Ralf and Schumacher, Ralph and Ibraheem, Wagdi and Schmalz, Stefan and Waldmann, Barbara and Guder, Christoph and Peter, Dennis and Schwager, Christian and Teixeira Boura, Cristiano Jos{\´e} and Alexopoulos, Spiros and Spiegel, Michael and Wortmann, J{\"u}rgen and Hinrichs, Matthias and Engelhard, Manfred and Aust, Michael}, title = {Techno-economic optimization of molten salt solar tower plants}, series = {AIP Conference Proceedings art.no. 040033}, volume = {2033}, journal = {AIP Conference Proceedings art.no. 040033}, number = {Issue 1}, publisher = {AIP Publishing}, address = {Melville, NY}, doi = {10.1063/1.5067069}, year = {2018}, abstract = {In this paper the results of a techno-economic analysis of improved and optimized molten salt solar tower plants (MSSTP plants) are presented. The potential improvements that were analyzed include different receiver designs, different designs of the HTF-system and plant control, increased molten salt temperatures (up to 640°C) and multi-tower systems. Detailed technological and economic models of the solar field, solar receiver and high temperature fluid system (HTF-system) were developed and used to find potential improvements compared to a reference plant based on Solar Two technology and up-to-date cost estimations. The annual yield model calculates the annual outputs and the LCOE of all variants. An improved external tubular receiver and improved HTF-system achieves a significant decrease of LCOE compared to the reference. This is caused by lower receiver cost as well as improvements of the HTF-system and plant operation strategy, significantly reducing the plant own consumption. A novel star receiver shows potential for further cost decrease. The cavity receiver concepts result in higher LCOE due to their high investment cost, despite achieving higher efficiencies. Increased molten salt temperatures seem possible with an adapted, closed loop HTF-system and achieve comparable results to the original improved system (with 565°C) under the given boundary conditions. In this analysis all multi tower systems show lower economic viability compared to single tower systems, caused by high additional cost for piping connections and higher cost of the receivers. REFERENCES}, language = {en} }