@inproceedings{ButenwegKleemannAltayetal.2013, author = {Butenweg, Christoph and Kleemann, Anne and Altay, Okyay and Renault, Philippe}, title = {Simulation of impact-loads on reinforced concrete structural elements}, series = {22nd International Conference on Structural Mechanics in Reactor Technology 2013 : (SMiRT 22) ; San Francisco, California, USA, 18 - 23 August 2013}, booktitle = {22nd International Conference on Structural Mechanics in Reactor Technology 2013 : (SMiRT 22) ; San Francisco, California, USA, 18 - 23 August 2013}, organization = {International Conference on Structural Mechanics in Reactor Technology, SMIRT <22, 2013, San Francisco, Calif.>}, pages = {1 -- 10}, year = {2013}, language = {en} } @inproceedings{ButenwegRosinKubalski2013, author = {Butenweg, Christoph and Rosin, Julia and Kubalski, Thomas}, title = {Seismic response of conventional and base-isolated liquid storage tanks}, series = {International Conference on Earthquake Engineering : 29.-31.05.2013, Skopje, Mazedonien}, booktitle = {International Conference on Earthquake Engineering : 29.-31.05.2013, Skopje, Mazedonien}, organization = {International Conference on Earthquake Engineering <2013, Skopje>}, pages = {1 -- 8}, year = {2013}, language = {en} } @inproceedings{GellertNordaButenweg2008, author = {Gellert, Christoph and Norda, Hannah and Butenweg, Christoph}, title = {Nonlinear behaviour of masonry under cyclic loading}, series = {7th European Conference on Structural Dynamics, EURODYN 2008 : 7-9 July 2008, Southampton}, booktitle = {7th European Conference on Structural Dynamics, EURODYN 2008 : 7-9 July 2008, Southampton}, organization = {European Conference on Structural Dynamics, EURODYN <7, 2008, Southampton>}, pages = {1 -- 12}, year = {2008}, language = {en} } @inproceedings{RenaultButenweg2005, author = {Renault, Philippe and Butenweg, Christoph}, title = {Seismic vulnerability assessment of bridges}, series = {First Munich Bridge Assessment Conference, MBAC 2005 : Munich, 20.-25. June 2005}, booktitle = {First Munich Bridge Assessment Conference, MBAC 2005 : Munich, 20.-25. June 2005}, organization = {Munich Bridge Assessment Conference <1, 2005>}, pages = {1 -- 16}, year = {2005}, language = {en} } @inproceedings{ButenwegSadeghAzarMeskouris2004, author = {Butenweg, Christoph and Sadegh-Azar, H. and Meskouris, Konstantin}, title = {Seismische Vulnerabilit{\"a}t von bestehenden Bauwerken}, series = {5. Forum und Gefahrentag : auf der Suche nach dem Risiko : ein aktuelles Symposium zu Fragen der Risikowahrnehmung und Katastrophenvorsorge in Deutschland, ZDF Mainz Lerchenberg, 13. - 14. Oktober, 2004}, booktitle = {5. Forum und Gefahrentag : auf der Suche nach dem Risiko : ein aktuelles Symposium zu Fragen der Risikowahrnehmung und Katastrophenvorsorge in Deutschland, ZDF Mainz Lerchenberg, 13. - 14. Oktober, 2004}, pages = {1}, year = {2004}, language = {de} } @inproceedings{ButenwegKuhlmannLopezetal.2003, author = {Butenweg, Christoph and Kuhlmann, Winfried and Lopez, M. and Fernandez, S.}, title = {Seismic vulnerability assessment of the Aachen Cathedral based on measurements and numerical simulations}, series = {International Conference on Earthquake Engineering to mark 40 years from Catastrophic 1963 Skopje Earthquake, Skopje 2003}, booktitle = {International Conference on Earthquake Engineering to mark 40 years from Catastrophic 1963 Skopje Earthquake, Skopje 2003}, organization = {International conference in earthquake engineering to mark 40 years from catastrophic 1963 Skopje earthquake <2003, Skopje>}, pages = {1 -- 8}, year = {2003}, language = {en} } @inproceedings{ChudobaButenwegKuhlmann2002, author = {Chudoba, Rostislav and Butenweg, Christoph and Kuhlmann, Wolfram}, title = {Technical information system for collaborative material research}, series = {Sixth International Conference on Computational Structures Technology : [Prague, Czech Republic, 4 - 6 September 2002]}, booktitle = {Sixth International Conference on Computational Structures Technology : [Prague, Czech Republic, 4 - 6 September 2002]}, organization = {International Conference on Computational Structures Technology <6, 2002, Prag>}, pages = {1 -- 11}, year = {2002}, language = {en} } @inproceedings{DalguerRenaultChurilovetal.2016, author = {Dalguer, Luis A. and Renault, Philippe and Churilov, Sergey and Butenweg, Christoph}, title = {Evaluation of fragility curves for a three-storey-reinforced-concrete mock-up of SMART 2013 project}, series = {Transactions, SMiRT-23 : 23rd Conference on Structural Mechanics in Reactor Technology : Manchester, United Kingdom - August 10-14, 2015}, booktitle = {Transactions, SMiRT-23 : 23rd Conference on Structural Mechanics in Reactor Technology : Manchester, United Kingdom - August 10-14, 2015}, organization = {Conference on Structural Mechanics in Reactor Technology <23, 2015, Manchester>}, pages = {1 -- 9}, year = {2016}, language = {en} } @incollection{BorchertHeimannSchemm2011, author = {Borchert, J{\"o}rg and Heimann, Thorsten and Schemm, Ralf}, title = {Speicheroptimierung}, series = {Gashandel und Gasbeschaffung}, booktitle = {Gashandel und Gasbeschaffung}, publisher = {Euroforum Verl.}, address = {D{\"u}sseldorf}, publisher = {Fachhochschule Aachen}, pages = {1 -- 69}, year = {2011}, abstract = {In dieser Lektion wurden beginnend mit der Darstellung des fundamentalen Wandels des Gasmarktes die daraus folgenden Implikationen f{\"u}r die Einsatzweise von Gasspeichern abgeleitet. Anschließend wurden zwei Bewertungs- und Steuerungsverfahren f{\"u}r einen Gasspeicher an den beiden Marktstufen Termin- und Spotmarkt methodisch vorgestellt und anhand von Beispielrechnungen illustriert. Das Verfahren zur Bewertung und Steuerung im Terminmarkt stellt ein sehr robustes und methodisch einfaches Verfahren dar. Hierbei wird die Saisonalit{\"a}t der Forwardkurve bzw. deren Ver{\"a}nderungen arbitragefrei mithilfe des Speichers ausgenutzt. Dieses Verfahren kann nicht den gesamten Zeitwert des Speichers ausweisen. Es zieht in jedem Zeitpunkt nur die aktuellen Informationen der Forwardkurve zur Entscheidung heran. Es bildet aber keine bedingte Erwartung {\"u}ber zuk{\"u}nftige Ertr{\"a}ge und deren Beeinflussung durch die aktuelle Speicherfahrweise, um hieraus eine optimale Entscheidung zu formulieren. Bei der Bewertung gegen{\"u}ber dem Spotmarkt mithilfe der Least-Squares-Monte- Carlo-Simulation wird in einer stochastischen Optimierung dagegen der volle Zeitwert des Speichers und damit der gesamte Zusatznutzen der Flexibilit{\"a}t ermittelt. Hierdurch leiten sich auch wesentlich andere Hedging-Empfehlungen als im ersten Verfahren ab, um diesen zu sichern. Der Einsatz der beiden Verfahren im Alltag zur Bewirtschaftung des Speichers h{\"a}ngt insbesondere vom Know-how, den Speicherparametern und der Risikobereitschaft des Handels ab. Beide Strategien liefern hierzu Hedging-Empfehlungen ab, mit welchem der zugrunde liegende Wert gesichert werden kann. Risikoaverse H{\"a}ndler, die einen Großteil des inneren Wertes sichern wollen, k{\"o}nnten im Terminmarkt einen Großteil des Speichers mithilfe des „Intrinsic Rolling"-Verfahrens bewirtschaften. Sie w{\"u}rden hierdurch den saisonalen Spread in der Forwardkurve rollierend sichern. Gleichzeitig kann ein kleinerer Anteil mithilfe der stochastischen Optimierung und den damit verbundenen Aus{\"u}bungsgrenzen gegen{\"u}ber dem Spotmarkt bewirtschaftet werden. In einem liquiden vollst{\"a}ndigen Markt wird eine Steuerung des Speichers allein gegen{\"u}ber den vorhandenen Marktstufen vorgenommen und der Wert f{\"u}r alle Marktteilnehmer objektiv messbar. F{\"u}r den Fall, dass der Markt illiquide ist und hierdurch z. B. eine Kundenlast nicht allein am Termin- und Spotmarkt jederzeit gedeckt werden kann, erscheint es notwendig, den Speicher im Kontext einer Portfoliooptimierung zu bewerten. Dies wird in der n{\"a}chsten Lektion vorgenommen. Hierbei ist aber zu beachten, dass der Speicher dadurch eine individualisierte Wertkomponente erh{\"a}lt, die von der konkreten Ausgestaltung des jeweiligen Portfolios abh{\"a}ngt.}, language = {de} } @inproceedings{HellmannsHesse2007, author = {Hellmanns, Mark and Hesse, Joachim}, title = {Ger{\"a}uschminderung und Leichtbau in Leistungsgetrieben durch den Einsatz von Werkstoffverbunden}, series = {Hybride Maschinenkonzepte und intelligente Verfahren zur Fertigung von High-Tech-Produkten : Erfolgsbeispiele zur Standortsicherung in Hochlohnl{\"a}ndern : InnoNet Kolloquium am 7. und 8.11.2007, Technologiezentrum am Europaplatz Aachen}, booktitle = {Hybride Maschinenkonzepte und intelligente Verfahren zur Fertigung von High-Tech-Produkten : Erfolgsbeispiele zur Standortsicherung in Hochlohnl{\"a}ndern : InnoNet Kolloquium am 7. und 8.11.2007, Technologiezentrum am Europaplatz Aachen}, pages = {1 -- 46}, year = {2007}, language = {de} } @inproceedings{BehrensFrentzelKern2009, author = {Behrens, J{\"o}rg and Frentzel, Ralf and Kern, Alexander}, title = {Simulation der transienten Spannungsverl{\"a}ufe im Eigenbedarfsnetz eines Großkraftwerks bei einem kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung}, isbn = {978-3-8007-3197-8}, year = {2009}, abstract = {8. VDE/ABB-Blitzschutztagung, 29. - 30. Oktober 2009 in Neu-Ulm. Blitzschutztagung <8, 2009, Neu-Ulm> Berlin : VDE Verl. 2009 Großkraftwerke k{\"o}nnen durch Blitzentladungen mit potentiellen Auswirkungen auf deren Verf{\"u}gbarkeit und Sicherheit gef{\"a}hrdet werden. Ein sehr spezielles Szenario, welches aus aktuellem Anlass zu untersuchen war, betrifft den kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung am Netzanschluss der Anlage. Wird nun noch ein sogenannter Schirmfehler unterstellt, d.h. der direkte Blitzeinschlag erfolgt in ein Leiterseil des Hoch- bzw. H{\"o}chstspannungsnetzes und nicht in das dar{\"u}ber gespannte Erdseil, so bedeutet dies eine extreme elektromagnetische Einwirkung. Der vorliegende Beitrag befasst sich mit der Simulation eines solchen Blitzeinschlages und dessen Auswirkungen auf den Netzanschluss und die Komponenten der elektrischen Eigenbedarfsanlagen eines Kraftwerks auf den unterlagerten Spannungsebenen. Die dabei gewonnenen Erkenntnisse lassen sich ohne Einschr{\"a}nkungen auf Industrieanlagen mit Mittelspannungs-Netzanschluss und ohne eigener Stromversorgung {\"u}bertragen.}, subject = {Blitzschutz}, language = {de} } @inproceedings{KernBeierlZischank2009, author = {Kern, Alexander and Beierl, Ottmar and Zischank, Wolfgang}, title = {Calculation of the separation distance according to IEC 62305-3: 2006-10 - Remarks for the application and simplified methods}, year = {2009}, abstract = {[Paper of the X International Symposium on Lightning Protection 9th - 13th November, 2009 - Curitiba, Brazil. 6 pages] The international standard IEC 62305-3, published in 2006, requires as an integral part of the lightning protection system (LPS) the consideration of a separation distance between the conductors of the LPS and metal and electrical installations inside the structure to be protected. IEC 62305-3 gives two different methods for this calculation: a standard, simplified approach and a more detailed approach, which differ especially regarding the treatment of the current sharing effect on the LPS conductors. Hence, different results for the separation distance are possible, leading to some discrepancies in the use of the standard. The standard approach defined in the main part (Clause 6.3) and in Annex C of the standard in some cases may lead to a severe oversizing of the required separation distance. The detailed approach described in Annex E naturally gives more correct results. However, a calculation of the current sharing amongst all parts of the air-termination and downconductor network is necessary, in many cases requiring the use of network analysis programs. In this paper simplified methods for the assessment of the current sharing are presented, which are easy to use as well as sufficiently adequate.}, subject = {Blitzschutz}, language = {de} } @article{WettingfeldKernKraemeretal.2009, author = {Wettingfeld, J{\"u}rgen and Kern, Alexander and Kr{\"a}mer, Heinz-Josef and Thorm{\"a}hlen, Reyno}, title = {International anerkannte Blitzschutznormen : Ausgewogener und sicherer Schutz}, publisher = {Fachhochschule Aachen}, address = {Aachen}, year = {2009}, abstract = {Die Einleitung zur Norm DIN EN 62305-3 beschreibt klar und ein - deutig: Der vorliegende Teil der IEC 62305 behandelt den Schutz von baulichen Anlagen gegen materielle Sch{\"a}den und den Schutz von Personen gegen Verletzungen durch Ber{\"u}hrungs- und Schrittspannungen. Als das wesentlichste und effektivste Mittel zum Schutz von baulichen Anlagen gegen materielle Sch{\"a}den gilt das Blitz - schutzsystem (LPS).}, subject = {Blitzschutz}, language = {de} } @misc{Kaster2009, author = {Kaster, Jan Mathis}, title = {Untersuchungen zur Specklereduktion bei der Infrarot-Laser gest{\"u}tzten Ferndetektion von TNT-Oberfl{\"a}chenkontaminationen}, year = {2009}, abstract = {Das Ziel der vorliegenden Arbeit ist die Specklereduktion bei der Infrarotlaser-gest{\"u}tzten abbildenden Ferndetektion von TNT-Oberfl{\"a}chenkontaminationen. F{\"u}r die Detektion wird die Probenoberfl{\"a}che mit einem abstimmbaren Quantenkaskadenlaser bei verschiedenen Wellenzahlen im Spektralbereich von 1340cm-1 bis 1380cm-1 bestrahlt, w{\"a}hrend eine Infrarot-Kamera Bilder der bestrahlten Fl{\"a}che aufzeichnet. Diese Bilder werden dann so verarbeitet, dass im Ausgabebild die chemisch spezifische TNT-Absorption durch eine {\"A}nderung der Helligkeit {\"o}rtlich aufgel{\"o}st erkennbar werden. Da koh{\"a}rente Strahlung, welche beispielsweise an optisch rauen Oberfl{\"a}chen reflektiert wird, aufgrund der stochastischen Verteilung der Oberfl{\"a}chenrautiefe mit der einfallenden Strahlung lateral unterschiedlich interferiert, entsteht ein „Rauschen" in der aufgezeichneten Strahlungsleistungsverteilung, das sog. Speckle-Ph{\"a}nomen. Die Empfindlichkeit der oben skizzierten Lasergest{\"u}tzten Messtechnik wird im Wesentlichen durch diesen Effekt limitiert. Um die durch Laserspeckles verursachten Rauschanteile zu reduzieren, gibt es verschiedene M{\"o}glichkeiten. Durch Reduktion von zeitlicher und r{\"a}umlicher Koh{\"a}renz der Strahlung wird deren Interferenzf{\"a}higkeit reduziert und durch Variieren des Specklemusters w{\"a}hrend einer Bildaufzeichnung f{\"u}hren Mittelungen unkorrelierter Rauschanteile zu einer Specklekontrastreduktion. Letztere M{\"o}glichkeit resultiert daraus, dass Laserspeckles statistisch durch die Familie der Gammaverteilungen beschrieben werden k{\"o}nnen. Demnach verbessert sich das Signal-zu-Rausch-Verh{\"a}ltnis mit der Anzahl gemittelter, unkorrelierter Rauschmuster proportional zur Wurzel dieser Anzahl. Ein im MIR-Spektralbereich umsetzbarer Ansatz, der all diese M{\"o}glichkeiten ber{\"u}cksichtigt, wurde bereits 1971 von Lowenthal und Joyeaux vorgeschlagen und im Rahmen der vorliegenden Arbeit f{\"u}r den infraroten Spektralbereich adaptiert. Dazu wird die Strahlung mit zwei CVD-Diamant-Wafern moduliert; ein Wafer ist dabei station{\"a}r und der andere rotiert mit ca. 70Hz. In der vorliegenden Arbeit konnte mit diesem Ansatz eine Verbesserung des Signal-zu-Rausch-Verh{\"a}ltnisses in der betrachteten Strahlungsleistungs¬verteilung von urspr{\"u}nglich 3 auf etwa 45 erzielt werden. So konnten erstmals TNT-Kontaminationen von bis zu 10µg/cm² in einem Abstand von 5m abbildend nachgewiesen werden. Dies entspricht der Kontamination durch einen mit TNT leicht verunreinigten Fingerabdruck.}, subject = {Speckle}, language = {de} } @inproceedings{KernDikta2009, author = {Kern, Alexander and Dikta, Gerhard}, title = {Probability of damage of electrical and electronic systems due to indirect lightning flashes - investigation of data from German insurance companies}, year = {2009}, abstract = {In the presented paper data collected from the field related to damage statistics of electrical and electronic apparatus in household are reported and investigated. These damages (total number approx. 74000 cases), registered by five German insurance companies in 2005 and 2006, were adviced by customers as caused by lightning overvoltages. With the use of stochastical methods it is possible, to reasses the collected data and to distinguish between cases, which are with high probability caused by lightning overvoltages, and those, which are not. If there was an indication for a direct strike, this case was excluded, so the focus was only on indirect lightning flashes, i.e. only flashes to ground near the structure and flashes to or nearby an incoming service line were investigated. The data from the field contain the location of damaged apparatus (residence of the policy holder) and the distances of the nearest cloud-to-ground stroke to the location of the damage registered by the German lightning location network BLIDS at the date of damage. The statistical data along with some complementary numerical simulations allow to verify the correspondence of the Standards rules used for IEC 62305-2 with the field data and to define some correction needs. The results could lead to a better understanding whether a damage reported to an insurance company is really caused by indirect lightning, or not.}, subject = {Blitzschutz}, language = {en} } @inproceedings{BruessermannDeuster2005, author = {Br{\"u}ssermann, Klaus and Deuster, M.}, title = {Temperature measurement to optimise the burning process}, year = {2005}, abstract = {One of the most important parameters in a burning chamber - in power stations, in waste to energy plants - is the temperature. This temperature is in the range of 700-1500 °C - one of the most advanced measuring methods being the acoustic pyrometry with the possibility of producing temperature mapping in one level of the burning chamber - comparable to computer tomography. The results of these measurements discussed in the presentation can be used - to fulfil the legal requirements in the FRG or in the EU - to equalise the temperature in one level of the burning chamber to optimise the steam production (better efficiency of the plant) and to minimise the production of temperature controlled flue gas components (NO, CO a. o.) - to control the SNCR-process if used.}, subject = {Pyrometrie}, language = {en} } @inproceedings{Bruessermann2005, author = {Br{\"u}ssermann, Klaus}, title = {Platform of Excellence in "Energy and Environment"}, year = {2005}, abstract = {The Ministry of Science and Research in North Rhine-Westphalia created eight platforms of excellence, one in the research area „Energy and Environment" in 2002 at ACUAS. This platform concentrates the research and development of 13 professors in J{\"u}lich and Aachen and of two scientific institutes with different topics: - NOWUM-Energy with emphasis on efficient and economic energy conversion - The Solar Institute J{\"u}lich - SIJ - being the largest research institute in the field of renewables at a University of Applied Sciences in Germany With this platform each possible energy conversion - nuclear, fossil, renewable- can be dealt with to help solving the two most important problems of mankind, energy and potable water. At the CSE are presented the historical development, some research results and the combined master studies in „Energy Systems" and „Nuclear Applications"}, subject = {Energietechnik}, language = {en} } @inproceedings{DielmannSchieke2000, author = {Dielmann, Klaus-Peter and Schieke, Wolf}, title = {Mikrogasturbinen - Aufbau und Anwendungen}, year = {2000}, abstract = {Mikrogasturbinen: Funktion, Aufbau, Hersteller, Bauformen, Rekuperatorparameter, Besonderheit der Konstruktion, Regelung, Regelbarkeit, Vergleich mit anderen Systemen, Wirkungs- und Nutzungsgrade, Schadstoffemissionen, Nutzung in Kraft-W{\"a}rme-Kopplung, Kraft-W{\"a}rme-K{\"a}lte-Kopplung}, subject = {Gasturbine}, language = {de} } @inproceedings{DielmannPeters2002, author = {Dielmann, Klaus-Peter and Peters, Bernhard}, title = {Micro Turbine Using Different Gases and Liquid Fuels}, year = {2002}, abstract = {Micro turbine using different gases and liquid fuels}, subject = {Gasturbine}, language = {en} } @inproceedings{DielmannVelden2003, author = {Dielmann, Klaus-Peter and Velden, Alwin van der}, title = {Virtuelle Kraftwerke - Stand der Technik}, year = {2003}, abstract = {Ausgangslage, Funktionsprinzip des virtuellen Kraftwerkes, Energiemanagementsysteme (EMS), Einsatzgebiete, Anlagesysteme eines VKW's, Einsatzbereich der verschiedenen dezentralen Energieanlagen, Vorteile des virtuellen Kraftwerkes, Auswirkungen auf das elektrische Netz, Wirtschaftliche Aspekte, Beispielprojekte}, language = {de} }