@incollection{HelsperDressler2012, author = {Helsper, Christoph and Dressler, J{\"o}rg}, title = {Partikelmesstechnik}, series = {Reinraumtechnik}, volume = {2012}, booktitle = {Reinraumtechnik}, editor = {Gail, Lothar and Gommel, Udo and Hortig, Hans-Peter}, edition = {3}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-642-19435-1}, doi = {10.1007/978-3-642-19435-1_3}, pages = {69 -- 95}, year = {2012}, abstract = {Der Schutz von Produkten vor der Kontamination durch Partikel gilt als eine zentrale Aufgabe der Reinraumtechnik. Da es dabei um Kontaminationseffekte weit unterhalb der visuellen Wahrnehmbarkeit geht, braucht es leistungsf{\"a}hige Verfahren, um die Messgr{\"o}ße „Partikelkontamination" {\"u}ber den gesamten Bereich, den Anwender fordern, pr{\"a}zise zu bestimmen. Neben der Partikelh{\"a}ufigkeit ist dabei die Gr{\"o}ße der Partikel, die sowohl das Transportverhalten wie auch die m{\"o}gliche Wirkung auf das Produkt beeinflusst, von entscheidender Bedeutung. Ferner kann es f{\"u}r die Ermittlung von Kontaminationsquellen von Interesse sein, die Form und die chemische Natur der Partikel zu bestimmen (z. B. textile Fasern, Metallabrieb, fl{\"u}ssige Tr{\"o}pfchen). Die Partikelh{\"a}ufigkeit wird {\"u}blicherweise als Konzentration, d. h. bezogen auf das analysierte Gasvolumen angegeben. Bei den in reinen Technologien {\"u}blichen niedrigen Konzentrationen dient als H{\"a}ufigkeitsmaß die Partikelanzahlkonzentration, also die Partikelanzahl pro Volumeneinheit des Tr{\"a}germediums.}, language = {de} } @article{Frings2012, author = {Frings, Michael}, title = {Immobilienfinanzierung und Verbraucherkredit : Das neue Verbraucherkreditrecht nach der Verbraucherkreditrichtlinie}, series = {NWB : Steuer- und Wirtschaftsrecht}, volume = {2012}, journal = {NWB : Steuer- und Wirtschaftsrecht}, number = {15}, publisher = {NWB-Verlag}, address = {Herne}, issn = {0028-3460}, pages = {1237 -- 1247}, year = {2012}, abstract = {Mit Gesetz vom 29.7.2009 (BGBl 2009 I S. 2355) hat der deutsche Gesetzgeber die EU-Verbraucherkreditrichtlinie 2008/48/EG vom 23.4.2008 NWB PAAAD-28762 in nationales Recht umgesetzt. In diesem Gesetz ist auch der Immobiliardarlehensvertrag neu geregelt worden. Auf diese besondere Kreditform sind grds. die Vorschriften zum Verbraucherkredit anzuwenden, so dass der Darlehensgeber auch im Fall einer Immobilienfinanzierung zu vorvertraglicher Information des Verbrauchers verpflichtet ist. Beim finanzierten Immobilienerwerb werden Ver{\"a}ußerer und kreditgebende Bank h{\"a}ufig in Abstimmung und Zusammenarbeit t{\"a}tig, so dass f{\"u}r die Bank besondere Aufkl{\"a}rungspflichten gegen{\"u}ber dem Verbraucher entstehen. Im Fall der Verletzung dieser Pflichten drohen ihr Schadensersatzanspr{\"u}che oder ein Widerrufsrecht des Verbrauchers.}, language = {de} } @article{SchusserPoghossianBaeckeretal.2012, author = {Schusser, Sebastian and Poghossian, Arshak and B{\"a}cker, Matthias and Leinhos, Marcel and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Characterization of biodegradable polymers with capacitive field-effect sensors}, series = {Sensors and actuators B: Chemical}, volume = {187}, journal = {Sensors and actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2012.07.099}, pages = {2 -- 7}, year = {2012}, abstract = {In vitro studies of the degradation kinetic of biopolymers are essential for the design and optimization of implantable biomedical devices. In the presented work, a field-effect capacitive sensor has been applied for the real-time and in situ monitoring of degradation processes of biopolymers for the first time. The polymer-covered field-effect sensor is, in principle, capable to detect any changes in bulk, surface and interface properties of the polymer induced by degradation processes. The feasibility of this approach has been experimentally proven by using the commercially available biomedical polymer poly(D,L-lactic acid) (PDLLA) as a model system. PDLLA films of different thicknesses were deposited on the Ta₂O₅-gate surface of the field-effect structure from a polymer solution by means of spin-coating method. The polymer-modified field-effect sensors have been characterized by means of capacitance-voltage and impedance-spectroscopy method. The degradation of the PDLLA was accelerated by changing the degradation medium from neutral (pH 7.2) to alkaline (pH 9) condition, resulting in drastic changes in the capacitance and impedance spectra of the polymer-modified field-effect sensor.}, language = {en} } @article{KirchnerOberlaenderFriedrichetal.2012, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Friedrich, Peter and Berger, J{\"o}rg and Rysstad, Gunnar and Sch{\"o}ning, Michael Josef and Keusgen, Michael}, title = {Realisation of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry}, series = {Sensors and Actuators B: Chemical}, volume = {170}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2011.01.032}, pages = {60 -- 66}, year = {2012}, abstract = {A calorimetric gas sensor is presented for the monitoring of vapour-phase H2O2 at elevated temperature during sterilisation processes in aseptic food industry. The sensor was built up on a flexible polyimide foil (thickness: 25 μm) that has been chosen due to its thermal stability and low thermal conductivity. The sensor set-up consists of two temperature-sensitive platinum thin-film resistances passivated by a layer of SU-8 photo resist and catalytically activated by manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilises the elevated temperature of the evaporated H2O2 aerosol. In an experimental test rig, the sensor has shown a sensitivity of 4.78 °C/(\%, v/v) in a H2O2 concentration range of 0\%, v/v to 8\%, v/v. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied medium temperatures between 210 °C and 270 °C of the gas stream. At flow rates of the gas stream from 8 m3/h to 12 m3/h, the sensor has shown only a slightly reduced sensitivity at a low flow rate of 8 m3/h. The sensor characterisation demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of industrial sterilisation processes.}, language = {en} } @article{MiyamotoKanekoMatsuoetal.2012, author = {Miyamoto, Ko-ichiro and Kaneko, Kazumi and Matsuo, Akira and Wagner, Torsten and Kanoh, Shin{\´i}chiro and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Miniaturized chemical imaging sensor system using an OLED display panel}, series = {Sensors and Actuators B: Chemical}, volume = {170}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2011.02.029}, pages = {82 -- 87}, year = {2012}, abstract = {The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the current-voltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated.}, language = {en} } @article{KotliarLanzlHanssenetal.2012, author = {Kotliar, Konstantin and Lanzl, Ines M. and Hanssen, Henner and Eberhardt, Karla and Vilser, Walthard and Halle, Martin and Heemann, Uwe and Schmidt-Trucks{\"a}ss, Arno and Baumann, Marcus}, title = {Does increased blood pressure rather than aging influence retinal pulse wave velocity?}, series = {Investigative Ophthalmology \& Visual Science, IOVS}, volume = {53}, journal = {Investigative Ophthalmology \& Visual Science, IOVS}, number = {4}, publisher = {ARVO}, address = {Rockville, Md.}, issn = {0146-0404}, doi = {10.1167/iovs.11-8815}, pages = {2119 -- 2126}, year = {2012}, abstract = {Purpose: It was demonstrated previously that retinal pulse wave velocity (rPWV) as a measure of retinal arterial stiffness is increased in aged anamnestically healthy volunteers compared with young healthy subjects. Using novel methodology of rPWV assessment this finding was confirmed and investigated whether it might relate to the increased blood pressure usually accompanying the aging process, rather than to the aging itself. Methods: A total of 12 young 25.5-year-old (24.0-28.8) [median(1st quartile-3rd quartile)] and 12 senior 68.5-year-old (63.8-71.8) anamnestically healthy volunteers; and 12 senior 63.0-year-old (60.8-65.0) validated healthy volunteers and 12 young 33.0-year-old (29.5-35.0) hypertensive patients were examined. Time-dependent alterations of vessel diameter were assessed by the Dynamic Vessel Analyzer in a retinal artery of each subject. The data were filtered and processed using mathematical signal analysis and rPWVs were calculated. Results: rPWV amounted to 1200 (990-1470) RU (relative units)/s in the hypertensive group and to 1040 (700-2230) RU/s in anamnestically healthy seniors. These differed significantly from rPWVs in young healthy group (410 [280-500] RU/s) and in validated healthy seniors (400 [320-510] RU/s). rPWV associated with age and mean arterial pressure (MAP) in the pooled cohort excluded validated healthy seniors. In a regression model these associations remain when alternately adjusted for MAP and age. When including validated healthy seniors in the pooled cohort only association with MAP remains. Conclusions: Both aging (with not excluded cardiovascular risk factors) and mild hypertension are associated with elevated rPWV. rPWV increases to a similar extent both in young mildly hypertensive subjects and in aged anamnestically healthy persons. Healthy aging is not associated with increased rPWV.}, language = {en} } @inproceedings{GerhardsSanderBelloum2012, author = {Gerhards, Michael and Sander, Volker and Belloum, Adam}, title = {About the flexible Migration of Workflow Tasks to Clouds : Combining on- and off-premise Executions of Applications}, series = {CLOUD COMPUTING 2012 : The Third International Conference on Cloud Computing, GRIDs, and Virtualization ; July 22-27, 2012 - Nice, France}, booktitle = {CLOUD COMPUTING 2012 : The Third International Conference on Cloud Computing, GRIDs, and Virtualization ; July 22-27, 2012 - Nice, France}, editor = {Zimmermann, Wolf and Lee, Yong Woo and Demchenko, Yuri}, publisher = {IARIA Journals}, isbn = {978-1-61208-216-5}, pages = {82 -- 87}, year = {2012}, abstract = {An increasing number of applications target their executions on specific hardware like general purpose Graphics Processing Units. Some Cloud Computing providers offer this specific hardware so that organizations can rent such resources. However, outsourcing the whole application to the Cloud causes avoidable costs if only some parts of the application benefit from the specific expensive hardware. A partial execution of applications in the Cloud is a tradeoff between costs and efficiency. This paper addresses the demand for a consistent framework that allows for a mixture of on- and off-premise calculations by migrating only specific parts to a Cloud. It uses the concept of workflows to present how individual workflow tasks can be migrated to the Cloud whereas the remaining tasks are executed on-premise.}, language = {en} } @article{NovacekTranKlingeetal.2012, author = {Novacek, V. and Tran, Thanh Ngoc and Klinge, U. and Tolba, R. H. and Staat, Manfred and Bronson, D. G. and Miesse, A. M. and Whiffen, J. and Turquier, F.}, title = {Finite element modelling of stapled colorectal end-to-end anastomosis : Advantages of variable height stapler design}, series = {Journal of Biomechanics}, volume = {45}, journal = {Journal of Biomechanics}, number = {115}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-2380}, doi = {10.1016/j.jbiomech.2012.07.021}, pages = {2693 -- 2697}, year = {2012}, abstract = {The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge.}, language = {en} } @article{NguyenDuongTranetal.2012, author = {Nguyen, Nhu Huynh and Duong, Minh Tuan and Tran, Thanh Ngoc and Pham, Phu Tinh and Grottke, O. and Tolba, R. and Staat, Manfred}, title = {Influence of a freeze-thaw cycle on the stress-stretch curves of tissues of porcine abdominal organs}, series = {Journal of Biomechanics}, volume = {45}, journal = {Journal of Biomechanics}, number = {14}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-2380}, doi = {10.1016/j.jbiomech.2012.07.008}, pages = {2382 -- 2386}, year = {2012}, abstract = {The paper investigates both fresh porcine spleen and liver and the possible decomposition of these organs under a freeze-thaw cycle. The effect of tissue preservation condition is an important factor which should be taken into account for protracted biomechanical tests. In this work, tension tests were conducted for a large number of tissue specimens from twenty pigs divided into two groups of 10. Concretely, the first group was tested in fresh state; the other one was tested after a freeze-thaw cycle which simulates the conservation conditions before biomechanical experiments. A modified Fung model for isotropic behavior was adopted for the curve fitting of each kind of tissues. Experimental results show strong effects of the realistic freeze-thaw cycle on the capsule of elastin-rich spleen but negligible effects on the liver which virtually contains no elastin. This different behavior could be explained by the autolysis of elastin by elastolytic enzymes during the warmer period after thawing. Realistic biomechanical properties of elastin-rich organs can only be expected if really fresh tissue is tested. The observations are supported by tests of intestines.}, language = {en} } @article{SpelthahnSchubertSchoening2012, author = {Spelthahn, Heiko and Schubert, J{\"u}rgen and Sch{\"o}ning, Michael Josef}, title = {D{\"u}nnschichtsensoren f{\"u}r die Schwermetallanalytik}, series = {GIT : Labor-Fachzeitschrift}, volume = {56}, journal = {GIT : Labor-Fachzeitschrift}, number = {4}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0016-3538}, pages = {285 -- 287}, year = {2012}, abstract = {Die Detektion von Schadstoffen repr{\"a}sentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte D{\"u}nnschichtsensoren bieten eine kosteng{\"u}nstige M{\"o}glichkeit, „online"-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuf{\"u}hren. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgl{\"a}sern zur Detektion von Schwermetallen in w{\"a}ssrigen Medien vorgestellt.}, language = {en} } @article{Huening2012, author = {H{\"u}ning, Felix}, title = {Using Trench PowerMOSFETs in Linear Mode}, series = {Power Electronics Europe (2012)}, journal = {Power Electronics Europe (2012)}, publisher = {DFA Media}, address = {Tonbridge}, issn = {1748-3530}, pages = {27 -- 29}, year = {2012}, abstract = {If we think about applications for modern Power MOSFETs using trench technology, running them in linear mode may not be top of the priority list. Yet there are multiple uses for Trench Power MOSFETs in linear mode. In fact, even turning the device on and off in switching applications is a form of linear operation. Also, these components can be run in linear mode to protect the device against voltage surges. This article will illustrate the factors that need to be considered for linear operation and show how Trench Power MOSFETs are suited to it.}, language = {en} } @incollection{Huening2012, author = {H{\"u}ning, Felix}, title = {PowerMOSFETs f{\"u}r Elektromotoren im Automobil : Vom Fensterheber zum EPS}, series = {Elektronik im Kraftfahrzeug : Innovationen bei Systemen und Komponenten ; mit 7 Tabellen}, booktitle = {Elektronik im Kraftfahrzeug : Innovationen bei Systemen und Komponenten ; mit 7 Tabellen}, editor = {Schmitz, G{\"u}nter}, publisher = {Expert Verlag}, address = {Renningen}, isbn = {978-3-8169-3110-2}, pages = {71 -- 81}, year = {2012}, language = {de} } @article{BohrnStuetzFuchsetal.2012, author = {Bohrn, U. and St{\"u}tz, E. and Fuchs, K. and Fleischer, M. and Sch{\"o}ning, Michael Josef and Wagner, P.}, title = {Monitoring of irritant gas using a whole-cell-based sensor system}, series = {Sensors and Actuators B: Chemical}, volume = {175}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2012.05.088}, pages = {208 -- 217}, year = {2012}, abstract = {Cell-based sensors for the detection of gases have long been underrepresented, due to the cellular requirement of being cultured in a liquid environment. In this work we established a cell-based gas biosensor for the detection of toxic substances in air, by adapting a commercial sensor chip (Bionas®), previously used for the measurement of pollutants in liquids. Cells of the respiratory tract (A549, RPMI 2650, V79), which survive at a gas phase in a natural context, are used as biological receptors. The physiological cell parameters acidification, respiration and morphology are continuously monitored in parallel. Ammonia was used as a highly water-soluble model gas to test the feasibility of the sensor system. Infrared measurements confirmed the sufficiency of the medium draining method. This sensor system provides a basis for many sensor applications such as environmental monitoring, building technology and public security.}, language = {en} } @article{SchneiderSchneider2012, author = {Schneider, Bettina and Schneider, Wilhelm}, title = {Due Diligence - Grundlagen und Checkliste f{\"u}r KMU}, series = {Betriebswirtschaft im Blickpunkt}, journal = {Betriebswirtschaft im Blickpunkt}, publisher = {IWW Institut f{\"u}r Wissen in der Wirtschaft}, address = {Nordkirchen}, issn = {2191-1118}, pages = {148 -- 149}, year = {2012}, abstract = {Im Folgenden sollen Anlass und Inhalt einer Due Diligence erl{\"a}utert werden. Im Rahmen einer Checkliste werden Beratern und Unternehmen Hinweise zu m{\"o}glichen Pr{\"u}fungsgebieten sowie zu vorzuhaltenden oder zu pr{\"u}fenden Unterlagen gegeben. Entstanden ist die Checkliste aus der langj{\"a}hrigen praktischen T{\"a}tigkeit der Autoren bei einer großen Wirtschaftspr{\"u}fungsgesellschaft bzw. einer deutschen Großbank.}, language = {de} } @article{KlingeWilkeMuehl2012, author = {Klinge, Uwe and Wilke, Ralf and M{\"u}hl, Thomas}, title = {Auswahl der Herniennetze nach der "effektiven Porosit{\"a}t" - warum das Gewicht weniger wichtig ist}, series = {Chirurgische Allgemeine : CHAZ ; Zeitung f{\"u}r Klinik und Praxis}, volume = {13}, journal = {Chirurgische Allgemeine : CHAZ ; Zeitung f{\"u}r Klinik und Praxis}, number = {12}, publisher = {Kaden}, address = {Mannheim}, isbn = {1615-5378}, pages = {297 -- 301}, year = {2012}, language = {de} } @article{BleckenHolthausSellheier2012, author = {Blecken, Udo and Holthaus-Sellheier, Ursula}, title = {Quantitative Prognoseverfahren f{\"u}r Mietpreise von Bueroimmobilien am Beispiel D{\"u}sseldorf}, series = {GuG : Grundst{\"u}cksmarkt und Grundst{\"u}ckswert}, volume = {23}, journal = {GuG : Grundst{\"u}cksmarkt und Grundst{\"u}ckswert}, number = {1}, publisher = {Werner}, address = {K{\"o}ln}, issn = {0938-0175}, pages = {12 -- 21}, year = {2012}, language = {de} } @article{KurulganDemirciDemirciLinderetal.2012, author = {Kurulgan Demirci, Eylem and Demirci, Taylan and Linder, Peter and Trzewik, J{\"u}rgen and Gierkowski, Jessica Ricarda and Gossmann, Matthias and Kayser, Peter and Porst, Dariusz and Digel, Ilya and Artmann, Gerhard and Temiz Artmann, Ayseg{\"u}l}, title = {rhAPC reduces the endothelial cell permeability via a decrease of contractile tensions induced by endothelial cells}, series = {Journal of Bioscience and Bioengineering}, volume = {113}, journal = {Journal of Bioscience and Bioengineering}, number = {2}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1347-4421}, doi = {10.1016/j.jbiosc.2012.03.019}, pages = {212 -- 219}, year = {2012}, abstract = {All cells generate contractile tension. This strain is crucial for mechanically controlling the cell shape, function and survival. In this study, the CellDrum technology quantifying cell's (the cellular) mechanical tension on a pico-scale was used to investigate the effect of lipopolysaccharide (LPS) on human aortic endothelial cell (HAoEC) tension. The LPS effect during gram-negative sepsis on endothelial cells is cell contraction causing endothelium permeability increase. The aim was to finding out whether recombinant activated protein C (rhAPC) would reverse the endothelial cell response in an in-vitro sepsis model. In this study, the established in-vitro sepsis model was confirmed by interleukin 6 (IL-6) levels at the proteomic and genomic levels by ELISA, real time-PCR and reactive oxygen species (ROS) activation by florescence staining. The thrombin cellular contraction effect on endothelial cells was used as a positive control when the CellDrum technology was applied. Additionally, the Ras homolog gene family, member A (RhoA) mRNA expression level was checked by real time-PCR to support contractile tension results. According to contractile tension results, the mechanical predominance of actin stress fibers was a reason of the increased endothelial contractile tension leading to enhanced endothelium contractility and thus permeability enhancement. The originality of this data supports firstly the basic measurement principles of the CellDrum technology and secondly that rhAPC has a beneficial effect on sepsis influenced cellular tension. The technology presented here is promising for future high-throughput cellular tension analysis that will help identify pathological contractile tension responses of cells and prove further cell in-vitro models.}, language = {en} } @incollection{Laack2012, author = {Laack, Walter van}, title = {Elektro- und Ultraschalltherapie}, series = {Leitfaden Naturheilverfahren : f{\"u}r die {\"a}rztliche Praxis}, booktitle = {Leitfaden Naturheilverfahren : f{\"u}r die {\"a}rztliche Praxis}, editor = {Beer, Andr{\´e}-Michael and Adler, Martin}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {978-3-437-56103-0}, doi = {10.1016/B978-3-437-56103-0.10013-5}, pages = {285 -- 299}, year = {2012}, language = {de} } @book{Laack2012, author = {Laack, Walter van}, title = {Schnittstelle Tod: Warum auf ein Danach vertrauen?}, publisher = {Books on Demand}, address = {Norderstedt}, isbn = {978-3-936624-14-4}, pages = {120 S. : Ill.,graph. Darst.}, year = {2012}, language = {de} } @book{WosnitzaHilgers2012, author = {Wosnitza, Franz and Hilgers, Hans Gerd}, title = {Energieeffizienz und Energiemanagement : Ein {\"U}berblick heutiger M{\"o}glichkeiten und Notwendigkeiten}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-8671-2}, pages = {Elektronische Ressource}, year = {2012}, language = {de} }