@book{WeberKaminskyKallweitetal.2005, author = {Weber, Hans-Joachim and Kaminsky, Radoslav and Kallweit, Stephan and Simons, Antoine}, title = {PIV measurements with high temporal resolution behind artificial heart valves}, pages = {9 S.}, year = {2005}, language = {en} } @article{WeberLacoKunetal.2009, author = {Weber, Hans-Joachim and Laco, Filip and Kun, Ma and Ramakrishna, S.}, title = {The dose effect of human bone marrow-derived mesenchymal stem cells on epidermal development in organotypic co-culture / Laco, Filip ; Kun, Ma ; Weber, Hans Joachim ; Ramakrishna, S. ; Chan, Casey K.}, series = {Journal of Dermatological Science. 55 (2009), H. 3}, journal = {Journal of Dermatological Science. 55 (2009), H. 3}, isbn = {0923-1811}, pages = {150 -- 160}, year = {2009}, language = {en} } @article{WeberMo2004, author = {Weber, Hans-Joachim and Mo, Xiumei}, title = {Electrospinning P(LLA-CL) nanofiber: a tubular scaffold fabrication with circumferential alignment / Xiumei Mo, Hans-Joachim Weber}, series = {Contributions from 6th Austrian Polymer Meeting : Vienna, Austria, September 15 - 17, 2003 / Symposium ed.: W. H. Binder}, journal = {Contributions from 6th Austrian Polymer Meeting : Vienna, Austria, September 15 - 17, 2003 / Symposium ed.: W. H. Binder}, publisher = {Wiley-VCH}, address = {Weinheim}, pages = {413 -- 416}, year = {2004}, language = {en} } @article{WeberMoChen2007, author = {Weber, Hans-Joachim and Mo, Xiumei and Chen, Zonggang}, title = {Electrospun nanofibers of collagen-chitosan and P(LLA-CL) for tissue engineering / Mo Xiumei, Chen Zonggang, Hans J. Weber}, series = {Frontiers of materials science in China. 1 (2007), H. 1}, journal = {Frontiers of materials science in China. 1 (2007), H. 1}, publisher = {-}, isbn = {1673-7377}, pages = {20 -- 23}, year = {2007}, language = {en} } @article{WeberMoRamakrishna2006, author = {Weber, Hans-Joachim and Mo, Xiumei and Ramakrishna, S.}, title = {PCL-PGLA composite tubular scaffold preparation and biocompatibility investigation / X. Mo, H.-J. Weber, S. Ramakrishna}, series = {The International journal of artificial organs. 29 (2006), H. 8}, journal = {The International journal of artificial organs. 29 (2006), H. 8}, publisher = {-}, pages = {790 -- 799}, year = {2006}, language = {en} } @inproceedings{WeberPorschenDietzeletal.1978, author = {Weber, Hans-Joachim and Porschen, W. and Dietzel, F. and [u.a.],}, title = {In vivo analysis of the influence of combined hyperthermia and gamma irradiation on euoxic and hypoxic tumor cells}, series = {Cancer therapy by hyperthermia and radiation : [proceedings of the 2. International Symposium on Cancer Therapy by Hyperthermia and Radiation, Essen, 2.-4.6.1977]}, booktitle = {Cancer therapy by hyperthermia and radiation : [proceedings of the 2. International Symposium on Cancer Therapy by Hyperthermia and Radiation, Essen, 2.-4.6.1977]}, editor = {Streffer, Christian}, publisher = {Urban and Schwarzenberg}, address = {Baltimore ; Munich [u.a.]}, isbn = {0-8067-1701-7}, pages = {276 -- 277}, year = {1978}, language = {en} } @article{WeberSchmittJahn1988, author = {Weber, Hans-Joachim and Schmitt, W. and Jahn, D.}, title = {Thermische Untersuchungen beim Bohren in kortikalem Knochen unter Verwendung verschiedener K{\"u}hlsysteme / Schmitt, W. ; Weber, H. J. ; Jahn, D.}, series = {Deutsche zahn{\"a}rztliche Zeitschrift : DZZ. 43 (1988), H. 7}, journal = {Deutsche zahn{\"a}rztliche Zeitschrift : DZZ. 43 (1988), H. 7}, isbn = {0012-1029}, pages = {802 -- 805}, year = {1988}, language = {de} } @article{WeberSchmittJahnetal.1989, author = {Weber, Hans-Joachim and Schmitt, W. and Jahn, D. and Euringer, H.}, title = {Ein Versuch zur theoretischen Temperaturermittlung im Schneidbereich bei Bohrungen in kortikalem Knochen - An Experiment to Calculate the Theoretical Temperature at the Drill - Cortical Bone Interface / Schmitt, W. ; Weber, H. J. ; Jahn, D. ; Euringer, H.}, series = {Biomedizinische Technik/Biomedical Engineering. 34 (1989), H. 3}, journal = {Biomedizinische Technik/Biomedical Engineering. 34 (1989), H. 3}, isbn = {0013-5585}, pages = {53 -- 56}, year = {1989}, language = {de} } @article{WeberSchulteLauterbachetal.1999, author = {Weber, Hans-Joachim and Schulte, A. and Lauterbach, Gerhard and S{\"u}dkamp, Michael [u.a.]}, title = {Studien{\"u}berblick zu transienten Druckexkursionen bei Membranoxygenatoren / A. Schulte, G. Lauterbach, M. S{\"u}dkamp, H.-J. Weber}, series = {Kardiotechnik. 8 (1999), H. 1}, journal = {Kardiotechnik. 8 (1999), H. 1}, isbn = {0941-2670}, pages = {14 -- 16}, year = {1999}, language = {de} } @inproceedings{WeberTersteggeEngelsetal.1996, author = {Weber, S. and Terstegge, Andreas and Engels, R. and Herzog, H. and Reinartz, R. and Reinhart, P. and Rongen, F. and M{\"u}ller-G{\"a}rtner, H. W. and Halling, H.}, title = {The KFA TierPET: performance characteristics and measurements}, series = {Conference record / 1996 IEEE Nuclear Science Symposium [and Medical Imaging], November 2 - 9, 1996, Anaheim, California ; vol. 2}, booktitle = {Conference record / 1996 IEEE Nuclear Science Symposium [and Medical Imaging], November 2 - 9, 1996, Anaheim, California ; vol. 2}, publisher = {IEEE}, address = {Piscataway, NJ}, organization = {Institute of Electrical and Electronics Engineers}, isbn = {0-7803-3534-1}, issn = {1082-3654}, pages = {1117 -- 1119}, year = {1996}, language = {en} } @inproceedings{WeberTersteggeHallingetal.1995, author = {Weber, S. and Terstegge, Andreas and Halling, H. and Herzog, H. and Reinartz, R. and Reinhart, P. and Rongen, F. and M{\"u}ller-G{\"a}rtner, H.-W.}, title = {The design of an animal PET: flexible geometry for achieving optimal spatial resolution or high sensitivity}, series = {Conference record / 1995 IEEE Nuclear Science Symposium and Medical Imaging, October 21 - 28, 1995, San Francisco ; vol. 2}, booktitle = {Conference record / 1995 IEEE Nuclear Science Symposium and Medical Imaging, October 21 - 28, 1995, San Francisco ; vol. 2}, publisher = {IEEE}, address = {Piscataway, NJ}, organization = {Institute of Electrical and Electronics Engineers}, isbn = {078033180X ; 0780331818 ; 0780331826}, pages = {1002 -- 1005}, year = {1995}, language = {en} } @article{WeckesserGriessmeierSchmidtetal.1998, author = {Weckesser, Martin and Grießmeier, Martin and Schmidt, Daniela and Sonnenberg, Frank and Ziemons, Karl and Kemna, Lars and Holschbach, Marcus and Langen, Karl-J. and M{\"u}ller-G{\"a}rtner, Hans-W.}, title = {Iodine-123 α-methyl tyrosine single-photon emission tomography of cerebral gliomas: standardised evaluation of tumour uptake and extent}, series = {European Journal of Nuclear Medicine}, volume = {25}, journal = {European Journal of Nuclear Medicine}, number = {2}, isbn = {1619-7089}, pages = {150 -- 156}, year = {1998}, abstract = {Single-photon emission tomography (SPET) with the amino acid analogue l-3-[123I]iodo-α-methyl tyrosine (IMT) is helpful in the diagnosis and monitoring of cerebral gliomas. Radiolabelled amino acids seem to reflect tumour infiltration more specifically than conventional methods like magnetic resonance imaging and computed tomography. Automatic tumour delineation based on maximal tumour uptake may cause an overestimation of mean tumour uptake and an underestimation of tumour extension in tumours with circumscribed peaks. The aim of this study was to develop a program for tumour delineation and calculation of mean tumour uptake which takes into account the mean background activity and is thus optimised to the problem of tumour definition in IMT SPET. Using the frequency distribution of pixel intensities of the tomograms a program was developed which automatically detects a reference brain region and draws an isocontour region around the tumour taking into account mean brain radioactivity. Tumour area and tumour/brain ratios were calculated. A three-compartment phantom was simulated to test the program. The program was applied to IMT SPET studies of 20 patients with cerebral gliomas and was compared to the results of manual analysis by three different investigators. Activity ratios and chamber extension of the phantom were correctly calculated by the automatic analysis. A method based on image maxima alone failed to determine chamber extension correctly. Manual region of interest analysis in patient studies resulted in a mean inter-observer standard deviation of 8.7\%±6.1\% (range 2.7\%-25.0\%). The mean value of the results of the manual analysis showed a significant correlation to the results of the automatic analysis (r = 0.91, P<0.0001 for the uptake ratio; r = 0.87, P<0.0001 for the tumour area). We conclude that the algorithm proposed simplifies the calculation of uptake ratios and may be used for observer-independent evaluation of IMT SPET studies. Three-dimensional tumour recognition and transfer to co-registered morphological images based on this program may be useful for the planning of surgical and radiation treatment.}, language = {en} } @article{WeckesserHufnagelZiemonsetal.1997, author = {Weckesser, Matthias and Hufnagel, Andreas and Ziemons, Karl and Grießmeier, Martin and Sonnenberg, Frank and Hackl{\"a}nder, Thomas and Langen, Karl-J. and Holschbach, Markus and Elger, Christian E. and M{\"u}ller-G{\"a}rtner, Hans-W.}, title = {Effect of partial volume correction on muscarinic cholinergic receptor imaging with single-photon emission tomography in patients with temporal lobe epilepsy}, series = {European Journal of Nuclear Medicine}, volume = {24}, journal = {European Journal of Nuclear Medicine}, number = {9}, isbn = {1619-7089}, pages = {1156 -- 1161}, year = {1997}, abstract = {Animal experiments and preliminary results in humans have indicated alterations of hippocampal muscarinic acetylcholine receptors (mAChR) in temporal lobe epilepsy. Patients with temporal lobe epilepsy often present with a reduction in hippocampal volume. The aim of this study was to investigate the influence of hippocampal atrophy on the quantification of mAChR with single photon emission tomography (SPET) in patients with temporal lobe epilepsy. Cerebral uptake of the muscarinic cholinergic antagonist [123I]4-iododexetimide (IDex) was investigated by SPET in patients suffering from temporal lobe epilepsy of unilateral (n=6) or predominantly unilateral (n=1) onset. Regions of interest were drawn on co-registered magnetic resonance images. Hippocampal volume was determined in these regions and was used to correct the SPET results for partial volume effects. A ratio of hippocampal IDex binding on the affected side to that on the unaffected side was used to detect changes in muscarinic cholinergic receptor density. Before partial volume correction a decrease in hippocampal IDex binding on the focus side was found in each patient. After partial volume no convincing differences remained. Our results indicate that the reduction in hippocampal IDex binding in patients with epilepsy is due to a decrease in hippocampal volume rather than to a decrease in receptor concentration.}, language = {en} } @article{WedrowskiBruyndonckxTavernieretal.2009, author = {Wedrowski, M. and Bruyndonckx, P. and Tavernier, S. and Zhi, L. and Dang, J. and Mendes, P. R. and Perez, J. M. and Ziemons, Karl}, title = {Robustness of neural networks algorithm for gamma detection in monolithic block detector, positron emission tomography}, series = {2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)}, journal = {2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)}, isbn = {1082-3654}, pages = {2625 -- 2628}, year = {2009}, abstract = {The monolithic scintillator block approach for gamma detection in the Positron Emission Tomography (PET) avoids estimating Depth of Interaction (DOI), reduces dead zones in detector and diminishes costs of detector production. Neural Networks (NN) are very efficient to determine the entrance point of a gamma incident on a scintillator block. This paper presents results on the robustness of the spatial resolution as a function of the random fraction in the data, temperature and HV fluctuations. This is important when implementing the method in a real scanner. Measurements were done with two Hamamatsu S8550 APD arrays, glued on a 20 {\~A}— 20 {\~A}— 10 mm3 monolithic LSO crystal block.}, language = {en} } @article{WegmannHacklStaatetal.2016, author = {Wegmann, Kilian and Hackl, Michael and Staat, Manfred and Mayer, Katharina and M{\"u}ller, Lars-Peter}, title = {Double plate osteosynthesis of proximal ulna fractures: biomechanical and clinical results}, series = {Knee surgery, sports traumatology, arthroscopy}, volume = {Volume 24}, journal = {Knee surgery, sports traumatology, arthroscopy}, number = {Supplement 1}, publisher = {Springer}, address = {Berlin}, issn = {0942-2056}, doi = {10.1007/s00167-016-4079-0}, pages = {58 -- 59}, year = {2016}, abstract = {While plate fixation of proximal ulna fractures might lead to superior clinical results compared to tension band wiring, regular plates represent an established risk factor for wound complications. The olecranon double plates (Medartis, Basel, CH) might decrease complications related to the osteosynthesis because of their low profile and better anatomical fit. This study aimed to evaluate the biomechanical performance and clinical results of the olecranon double plates.}, language = {en} } @inproceedings{WeilPoghossianSchoeningetal.2012, author = {Weil, M. and Poghossian, Arshak and Sch{\"o}ning, Michael Josef and Cherstvy, A.}, title = {Electrical monitoring of layer-by-layer adsorption of oppositely charged macromolecules by means of capacitive field-effect devices}, isbn = {978-3-9813484-2-2}, doi = {10.5162/IMCS2012/P2.5.2}, pages = {1575 -- 1578}, year = {2012}, language = {en} } @inproceedings{WeldenSeverinsPoghossianetal.2022, author = {Welden, Melanie and Severins, Robin and Poghossian, Arshak and Wege, Christina and Siegert, Petra and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Studying the immobilization of acetoin reductase with Tobacco mosaic virus particles on capacitive field-effect sensors}, series = {2022 IEEE International Symposium on Olfaction and Electronic Nose (ISOEN)}, booktitle = {2022 IEEE International Symposium on Olfaction and Electronic Nose (ISOEN)}, publisher = {IEEE}, isbn = {978-1-6654-5860-3 (Online)}, doi = {10.1109/ISOEN54820.2022.9789657}, pages = {4 Seiten}, year = {2022}, abstract = {A capacitive electrolyte-insulator-semiconductor (EISCAP) biosensor modified with Tobacco mosaic virus (TMV) particles for the detection of acetoin is presented. The enzyme acetoin reductase (AR) was immobilized on the surface of the EISCAP using TMV particles as nanoscaffolds. The study focused on the optimization of the TMV-assisted AR immobilization on the Ta 2 O 5 -gate EISCAP surface. The TMV-assisted acetoin EISCAPs were electrochemically characterized by means of leakage-current, capacitance-voltage, and constant-capacitance measurements. The TMV-modified transducer surface was studied via scanning electron microscopy.}, language = {en} } @article{WeldenNagamineKomesuWagneretal.2021, author = {Welden, Rene and Nagamine Komesu, Cindy A. and Wagner, Patrick H. and Sch{\"o}ning, Michael Josef and Wagner, Torsten}, title = {Photoelectrochemical enzymatic penicillin biosensor: A proof-of-concept experiment}, series = {Electrochemical Science Advances}, volume = {2}, journal = {Electrochemical Science Advances}, number = {4}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {2698-5977}, doi = {10.1002/elsa.202100131}, pages = {1 -- 5}, year = {2021}, abstract = {Photoelectrochemical (PEC) biosensors are a rather novel type of biosensors thatutilizelighttoprovideinformationaboutthecompositionofananalyte,enablinglight-controlled multi-analyte measurements. For enzymatic PEC biosensors,amperometric detection principles are already known in the literature. In con-trast, there is only a little information on H+-ion sensitive PEC biosensors. Inthis work, we demonstrate the detection of H+ions emerged by H+-generatingenzymes, exemplarily demonstrated with penicillinase as a model enzyme on atitanium dioxide photoanode. First, we describe the pH sensitivity of the sensorand study possible photoelectrocatalytic reactions with penicillin. Second, weshow the enzymatic PEC detection of penicillin.}, language = {en} } @article{WeldenSchejaSchoeningetal.2018, author = {Welden, Rene and Scheja, Sabrina and Sch{\"o}ning, Michael Josef and Wagner, Patrick and Wagner, Torsten}, title = {Electrochemical Evaluation of Light-Addressable Electrodes Based on TiO2 for the Integration in Lab-on-Chip Systems}, series = {physica status solidi a : applications and materials sciences}, volume = {215}, journal = {physica status solidi a : applications and materials sciences}, number = {15}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201800150}, pages = {Article number 1800150}, year = {2018}, abstract = {In lab-on-chip systems, electrodes are important for the manipulation (e.g., cell stimulation, electrolysis) within such systems. An alternative to commonly used electrode structures can be a light-addressable electrode. Here, due to the photoelectric effect, the conducting area can be adjusted by modification of the illumination area which enables a flexible control of the electrode. In this work, titanium dioxide based light-addressable electrodes are fabricated by a sol-gel technique and a spin-coating process, to deposit a thin film on a fluorine-doped tin oxide glass. To characterize the fabricated electrodes, the thickness, and morphological structure are measured by a profilometer and a scanning electron microscope. For the electrochemical behavior, the dark current and the photocurrent are determined for various film thicknesses. For the spatial resolution behavior, the dependency of the photocurrent while changing the area of the illuminated area is studied. Furthermore, the addressing of single fluid compartments in a three-chamber system, which is added to the electrode, is demonstrated.}, language = {en} } @article{WeldenSchoeningWagneretal.2020, author = {Welden, Rene and Sch{\"o}ning, Michael Josef and Wagner, Patrick H. and Wagner, Torsten}, title = {Light-Addressable Electrodes for Dynamic and Flexible Addressing of Biological Systems and Electrochemical Reactions}, series = {Sensors}, volume = {20}, journal = {Sensors}, number = {6}, publisher = {MDPI}, address = {Basel}, issn = {1424-8220}, doi = {10.3390/s20061680}, pages = {Artikel 1680}, year = {2020}, abstract = {In this review article, we are going to present an overview on possible applications of light-addressable electrodes (LAE) as actuator/manipulation devices besides classical electrode structures. For LAEs, the electrode material consists of a semiconductor. Illumination with a light source with the appropiate wavelength leads to the generation of electron-hole pairs which can be utilized for further photoelectrochemical reaction. Due to recent progress in light-projection technologies, highly dynamic and flexible illumination patterns can be generated, opening new possibilities for light-addressable electrodes. A short introduction on semiconductor-electrolyte interfaces with light stimulation is given together with electrode-design approaches. Towards applications, the stimulation of cells with different electrode materials and fabrication designs is explained, followed by analyte-manipulation strategies and spatially resolved photoelectrochemical deposition of different material types.}, language = {en} }