@article{SavitskayaKistaubayevaDigeletal.2017, author = {Savitskaya, I. S. and Kistaubayeva, A. S. and Digel, Ilya and Shokatayeva, D. H.}, title = {Physicochemical and Antibacterial Properties of Composite Films Based on Bacterial Cellulose and Chitosan for Wound Dressing Materials}, series = {Eurasian Chemico-Technological Journal}, volume = {19}, journal = {Eurasian Chemico-Technological Journal}, number = {3}, issn = {2522-4867}, doi = {10.18321/ectj670}, pages = {255 -- 264}, year = {2017}, language = {en} } @phdthesis{BassamAbduljabbar2015, author = {Bassam Abduljabbar, Rasha}, title = {Physikalisch-chemische Steuerung der Proteinstabilit{\"a}t in biologischen Systemen}, year = {2015}, language = {de} } @article{KotliarKoshitzSvetlovaetal.2006, author = {Kotliar, Konstantin and Koshitz, I. N. and Svetlova, O. V. and Zaseeva, M. V.}, title = {Physiological principles of hypotensive therapy of open-angle glaucoma during presbyopic period. Part I Initial theoretical presuppositions, hypotheses and facts / Koshitz, I. N. ; Svetlova, O. V. ; Zaseeva, M. V. ; Shuhaev, S. V. ; Makarov, F. N. ; Kotli}, series = {Glaukoma (2006)}, journal = {Glaukoma (2006)}, publisher = {-}, pages = {35 -- 53}, year = {2006}, language = {en} } @article{KotliarKoshitzSvetlowaetal.2006, author = {Kotliar, Konstantin and Koshitz, I. N. and Svetlowa, O. V. and Zaseeva, M. V.}, title = {Physiological principles of hypotensive therapy of open-angle glaucoma during presbyopic period. Part II Promising algorithms of practical sparing applications / Koshitz, I. N. ; Svetlova, O. V. ; Zaseeva, M. V. ; Shuhaev, S. V. ; Makarov, F. N. ; Kotliar}, series = {Glaukoma (2006)}, journal = {Glaukoma (2006)}, publisher = {-}, pages = {51 -- 70}, year = {2006}, language = {en} } @article{StadlerGarveyEmbsetal.2014, author = {Stadler, Alexander Maximilian and Garvey, Christopher J. and Embs, Jan Peter and Koza, Michael Marek and Unruh, Tobias and Artmann, Gerhard and Zaccai, Guiseppe}, title = {Picosecond dynamics in haemoglobin from different species: A quasielastic neutron scattering study}, series = {Biochimica et biophysica acta (BBA): General Subjects}, volume = {1840}, journal = {Biochimica et biophysica acta (BBA): General Subjects}, number = {10}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1872-8006 (E-Journal); 0304-4165 (Print)}, doi = {10.1016/j.bbagen.2014.06.007}, pages = {2989 -- 2999}, year = {2014}, language = {en} } @techreport{Artmann2011, author = {Artmann, Gerhard}, title = {Plant mutant scanner : Hochdurchsatzscanner zur Charakterisierung von Pflanzenmutanten. Abschlussbericht ; FHprofUnd ; PhytoScan ; Laufzeit des Vorhabens: 01.07.2008 - 30.06.2011}, publisher = {Technische Informationsbibliothek u. Universit{\"a}tsbibliothek}, address = {Aachen}, doi = {10.2314/GBV:747569150}, year = {2011}, language = {de} } @inproceedings{DigelTemizArtmannArtmannetal.2003, author = {Digel, Ilya and Temiz Artmann, Ayseg{\"u}l and Artmann, Gerhard and Nojima, H.}, title = {Plasma cluster ions (PCI) influence on microbial cells viability : [abstract]}, year = {2003}, abstract = {Recently, SHARP corporation has developed the world's first "Plasma Cluster Ions (PCI)" air purification technology, which uses plasma discharge to generate cluster ions. The new plasma cluster device releases into the air positive and negative ions, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. A lot of phenomenological tests of the PCI air purification technology on microbial cells have been conducted. And, in most cases, it has been shown that PCI demonstrate strongly pronounced killing effect. Although, the particular mechanisms of PCI action are still not evident. We studied variations in resistance to PCI among gram-positive airborne microorganisms, as well as some dose-dependent, spatial, cultural and biochemical properties of PCI action in respect of Staphylococcus spp, Enterococcus spp, Micrococcus spp.}, subject = {Clusterion}, language = {en} } @inproceedings{DigelTemizArtmannNojimaetal.2003, author = {Digel, Ilya and Temiz Artmann, Ayseg{\"u}l and Nojima, H. and Artmann, Gerhard}, title = {Plasma-generated cluster ions' effects on indoor microflora : [abstract]}, year = {2003}, abstract = {Recently, SHARP corporation has developed the world's first "Plasma Cluster Ions® (PCI)" air purification technology, which uses plasma discharge to generate cluster ions. The new Plasma Cluster Device releases positive and negative ions into the air, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. In the past, phenomenological tests on the efficacy of the PCI air purification technology on microbial cells have been conducted. In most cases, it has been shown that PCI demonstrated strongly pronounced killing effects on microorganisms. However, the particular mechanisms of PCI action still have to be uncovered.}, subject = {Clusterion}, language = {en} } @article{Staat2004, author = {Staat, Manfred}, title = {Plastic collapse analysis of longitudinally flawed pipes and vessels}, year = {2004}, abstract = {Improved collapse loads of thick-walled, crack containing pipes and vessels are suggested. Very deep cracks have a residual strength which is better modelled by a global limit load. In all burst tests, the ductility of pressure vessel steels was sufficiently high whereby the burst pressure could be predicted by limit analysis with no need to apply fracture mechanics. The relative prognosis error increases however, for long and deep defects due to uncertainties of geometry and strength data.}, subject = {Druckbeh{\"a}lter}, language = {en} } @article{Staat2004, author = {Staat, Manfred}, title = {Plastic collapse analysis of longitudinally flawed pipes and vessels}, series = {Nuclear Engineering and Design. 234 (2004), H. 1-3}, journal = {Nuclear Engineering and Design. 234 (2004), H. 1-3}, isbn = {0029-5493}, pages = {25 -- 43}, year = {2004}, language = {en} } @article{ArampatzisPeperBierbaumetal.2010, author = {Arampatzis, Adamantios and Peper, Andreas and Bierbaum, Stefanie and Albracht, Kirsten}, title = {Plasticity of human Achilles tendon mechanical and morphological properties in response to cyclic strain}, series = {Journal of Biomechanics}, volume = {43}, journal = {Journal of Biomechanics}, number = {16}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0021-9290}, doi = {10.1016/j.jbiomech.2010.08.014}, pages = {3073 -- 3079}, year = {2010}, abstract = {The purpose of the current study in combination with our previous published data (Arampatzis et al., 2007) was to examine the effects of a controlled modulation of strain magnitude and strain frequency applied to the Achilles tendon on the plasticity of tendon mechanical and morphological properties. Eleven male adults (23.9±2.2 yr) participated in the study. The participants exercised one leg at low magnitude tendon strain (2.97±0.47\%), and the other leg at high tendon strain magnitude (4.72±1.08\%) of similar frequency (0.5 Hz, 1 s loading, 1 s relaxation) and exercise volume (integral of the plantar flexion moment over time) for 14 weeks, 4 days per week, 5 sets per session. The exercise volume was similar to the intervention of our earlier study (0.17 Hz frequency; 3 s loading, 3 s relaxation) allowing a direct comparison of the results. Before and after the intervention ankle joint moment has been measured by a dynamometer, tendon-aponeurosis elongation by ultrasound and cross-sectional area of the Achilles tendon by magnet resonance images (MRI). We found a decrease in strain at a given tendon force, an increase in tendon-aponeurosis stiffness and tendon elastic modulus of the Achilles tendon only in the leg exercised at high strain magnitude. The cross-sectional area (CSA) of the Achilles tendon did not show any statistically significant (P>0.05) differences to the pre-exercise values in both legs. The results indicate a superior improvement in tendon properties (stiffness, elastic modulus and CSA) at the low frequency (0.17 Hz) compared to the high strain frequency (0.5 Hz) protocol. These findings provide evidence that the strain magnitude applied to the Achilles tendon should exceed the value, which occurs during habitual activities to trigger adaptational effects and that higher tendon strain duration per contraction leads to superior tendon adaptational responses.}, language = {en} } @article{ArampatzisKaramanidisMademlietal.2009, author = {Arampatzis, Adamantios and Karamanidis, Kiros and Mademli, Lida and Albracht, Kirsten}, title = {Plasticity of the human tendon to short and long-term mechanical loading}, series = {Exercise and Sport Sciences Reviews}, volume = {37}, journal = {Exercise and Sport Sciences Reviews}, number = {2}, issn = {1538-3008}, doi = {10.1097/JES.0b013e31819c2e1d}, pages = {66 -- 72}, year = {2009}, language = {en} } @article{MichaelMayerWeberetal.2017, author = {Michael, Hackl and Mayer, Katharina and Weber, Mareike and Staat, Manfred and van Riet, Roger and Burkhart, Klau Josef and M{\"u}ller, Lars Peter and Wegmann, Kilian}, title = {Plate osteosynthesis of proximal ulna fractures : a biomechanical micromotion analysis}, series = {The journal of hand surgery}, volume = {42}, journal = {The journal of hand surgery}, number = {10}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0363-5023}, doi = {10.1016/j.jhsa.2017.05.014}, pages = {834.e1 -- 834.e7}, year = {2017}, language = {en} } @techreport{StoelzleFeixThomasEngelstaedteretal.2021, author = {St{\"o}lzle-Feix, Sonja and Thomas, Ulrich and Engelst{\"a}dter, Max and Goßmann, Matthias and Linder, Peter and Staat, Manfred and Raman, Aravind Hariharan and Jung, Alexander and Fertig, Niels}, title = {Plattformtechnologie f{\"u}r kardiale Sicherheitspharmakologie basierend auf teilsynthetischem Herzmuskelgewebe (FLEXcyte) : gemeinsamer FuE-Abschlussbericht aller Partner des Verbundprojektes : Projektlaufzeit: 01.10.2018 bis 30.09.2020}, publisher = {Nanion Technologies GmbH}, address = {M{\"u}nchen}, doi = {10.2314/KXP:1813208581}, pages = {IV, 85 Seiten, 2 ungez{\"a}hlte Seiten}, year = {2021}, language = {de} } @article{MaggakisKelemenDigelArtmann2005, author = {Maggakis-Kelemen, Christina and Digel, Ilya and Artmann, Gerhard}, title = {Polystyrene sulfonate/Polyallylamine hydrochloride microcapsules as potential artificial red blood cells - improvement of capsule flexibility}, series = {Biomedizinische Technik. 50 (2005), H. Erg.-Bd. 1}, journal = {Biomedizinische Technik. 50 (2005), H. Erg.-Bd. 1}, pages = {324 -- 326}, year = {2005}, language = {en} } @article{CiritsisHorbachStaatetal.2018, author = {Ciritsis, Alexander and Horbach, Andreas and Staat, Manfred and Kuhl, Christiane K. and Kraemer, Nils Andreas}, title = {Porosity and tissue integration of elastic mesh implants evaluated in vitro and in vivo}, series = {Journal of Biomedical Materials Research: Part B: Applied Biomaterials}, volume = {106}, journal = {Journal of Biomedical Materials Research: Part B: Applied Biomaterials}, number = {2}, publisher = {Wiley}, address = {New York, NY}, issn = {1552-4981}, doi = {10.1002/jbm.b.33877}, pages = {827 -- 833}, year = {2018}, abstract = {Purpose In vivo, a loss of mesh porosity triggers scar tissue formation and restricts functionality. The purpose of this study was to evaluate the properties and configuration changes as mesh deformation and mesh shrinkage of a soft mesh implant compared with a conventional stiff mesh implant in vitro and in a porcine model. Material and Methods Tensile tests and digital image correlation were used to determine the textile porosity for both mesh types in vitro. A group of three pigs each were treated with magnetic resonance imaging (MRI) visible conventional stiff polyvinylidene fluoride meshes (PVDF) or with soft thermoplastic polyurethane meshes (TPU) (FEG Textiltechnik mbH, Aachen, Germany), respectively. MRI was performed with a pneumoperitoneum at a pressure of 0 and 15 mmHg, which resulted in bulging of the abdomen. The mesh-induced signal voids were semiautomatically segmented and the mesh areas were determined. With the deformations assessed in both mesh types at both pressure conditions, the porosity change of the meshes after 8 weeks of ingrowth was calculated as an indicator of preserved elastic properties. The explanted specimens were examined histologically for the maturity of the scar (collagen I/III ratio). Results In TPU, the in vitro porosity increased constantly, in PVDF, a loss of porosity was observed under mild stresses. In vivo, the mean mesh areas of TPU were 206.8 cm2 (± 5.7 cm2) at 0 mmHg pneumoperitoneum and 274.6 cm2 (± 5.2 cm2) at 15 mmHg; for PVDF the mean areas were 205.5 cm2 (± 8.8 cm2) and 221.5 cm2 (± 11.8 cm2), respectively. The pneumoperitoneum-induced pressure increase resulted in a calculated porosity increase of 8.4\% for TPU and of 1.2\% for PVDF. The mean collagen I/III ratio was 8.7 (± 0.5) for TPU and 4.7 (± 0.7) for PVDF. Conclusion The elastic properties of TPU mesh implants result in improved tissue integration compared to conventional PVDF meshes, and they adapt more efficiently to the abdominal wall. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 827-833, 2018.}, language = {en} } @article{KotliarKozlovaLanzl2009, author = {Kotliar, Konstantin and Kozlova, Tatiana V. and Lanzl, Ines M.}, title = {Postoperative aqueous outflow in the human eye after glaucoma filtration surgery: biofluidmechanical considerations}, series = {Biomedizinische Technik = Biomedical Engineering}, volume = {54}, journal = {Biomedizinische Technik = Biomedical Engineering}, number = {1}, publisher = {-}, isbn = {1862-278X}, pages = {14 -- 22}, year = {2009}, language = {en} } @article{JayaramanMummidisettyLoeschetal.2019, author = {Jayaraman, Chandrasekaran and Mummidisetty, Chaitanya Krishna and Loesch, Alexandra and Kaur, Sandi and Hoppe-Ludwig, Shenan and Staat, Manfred and Jayaraman, Arun}, title = {Postural and metabolic benefits of using a forearm support walker in older adults with impairments}, series = {Archives of Physical Medicine and Rehabilitation}, volume = {Volume 100}, journal = {Archives of Physical Medicine and Rehabilitation}, number = {Issue 4}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0003-9993}, doi = {10.1016/j.apmr.2018.10.001}, pages = {638 -- 647}, year = {2019}, language = {en} } @article{DachwaldBaturkinCoverstoneetal.2006, author = {Dachwald, Bernd and Baturkin, Volodymyr and Coverstone, Victoria L. and Dietrich, Benjamin and Garbe, Gregory P. and G{\"o}rlich, Marianne and Leipold, Manfred and Lura, Franz and Macdonald, Malcolm and McInnes, Colin R. and Mengali, Giovanni and Quatra, Alessandro A. and Rios-Reyes, Leonel and Scheeres, Daniel J. and Seboldt, Wolfgang and Wie, Bong}, title = {Potential Effects of Optical Solar Sail Degradation on Interplanetary Trajectory Design}, series = {Astrodynamics 2005 : proceedings of the AAS/AIAA astrodynamics conference held August 7 - 11, 2005, South Lake Tahoe, California / ed. by Bobby G. Williams. - Pt. 3. - (Advances in the astronautical sciences ; 123,3)}, journal = {Astrodynamics 2005 : proceedings of the AAS/AIAA astrodynamics conference held August 7 - 11, 2005, South Lake Tahoe, California / ed. by Bobby G. Williams. - Pt. 3. - (Advances in the astronautical sciences ; 123,3)}, publisher = {Univelt}, address = {San Diego, Calif.}, isbn = {0-87703-527-X}, pages = {2569 -- 2592}, year = {2006}, language = {en} } @inproceedings{DachwaldBaturkinCoverstoneetal.2005, author = {Dachwald, Bernd and Baturkin, Volodymyr and Coverstone, Victoria and Diedrich, Ben and Garbe, Gregory and G{\"o}rlich, Marianne and Leipold, Manfred and Lura, Franz and Macdonald, Malcolm and McInnes, Colin and Mengali, Giovanni and Quarta, Alessandro and Rios-Reyes, Leonel and Scheeres, Daniel J. and Seboldt, Wolfgang and Wie, Bong}, title = {Potential effects of optical solar sail degredation on trajectory design}, series = {AAS/AIAA Astrodynamics Specialist}, booktitle = {AAS/AIAA Astrodynamics Specialist}, pages = {1 -- 23}, year = {2005}, abstract = {The optical properties of the thin metalized polymer films that are projected for solar sails are assumed to be affected by the erosive effects of the space environment. Their degradation behavior in the real space environment, however, is to a considerable degree indefinite, because initial ground test results are controversial and relevant inspace tests have not been made so far. The standard optical solar sail models that are currently used for trajectory design do not take optical degradation into account, hence its potential effects on trajectory design have not been investigated so far. Nevertheless, optical degradation is important for high-fidelity solar sail mission design, because it decreases both the magnitude of the solar radiation pressure force acting on the sail and also the sail control authority. Therefore, we propose a simple parametric optical solar sail degradation model that describes the variation of the sail film's optical coefficients with time, depending on the sail film's environmental history, i.e., the radiation dose. The primary intention of our model is not to describe the exact behavior of specific film-coating combinations in the real space environment, but to provide a more general parametric framework for describing the general optical degradation behavior of solar sails. Using our model, the effects of different optical degradation behaviors on trajectory design are investigated for various exemplary missions.}, language = {en} }