@inproceedings{AridaKloockSchoening2006, author = {Arida, Hassan A. and Kloock, Joachim P. and Sch{\"o}ning, Michael Josef}, title = {Novel organic membrane-based thin-film microsensors for the determination of heavy metal cations}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1545}, year = {2006}, abstract = {A first step towards the fabrication and electrochemical evaluation of thin-film microsensors based on organic PVC membranes for the determination of Hg(II), Cd(II), Pb(II) and Cu(II) ions in solutions has been realised. The membrane-coating mixture used in the preparation of this new type of microsensors is incorporating PVC as supporting matrix, o-nitrophenyloctylether (o-NPOE) as solvent mediator and a recently synthesized Hg[dimethylglyoxime(phene)]2+ and Bis-(4-hydroxyacetophenone)-ethylenediamine as electroactive materials for Hg(II) and Cd(II), respectively. A set of three commercialised ionophores for Cd(II), Pb(II) and Cu(II) has been also used for comparison. Thin-film microsensors based on these membranes showed a Nernstian response of slope (26-30 mV/dec.) for the respective tested cations. The potentiometric response characteristics (linear range, pH range, detection limit and response time) are comparable with those obtained by conventional membranes as well as coated wire electrodes prepared from the same membrane. The realisation of the new organic membrane-based thin-film microsensors overcomes the problem of an insufficient selectivity of solid-state-based thinfilm sensors.}, subject = {Biosensor}, language = {en} } @inproceedings{O'HerasDigelTemizArtmann2009, author = {O\'Heras, Carlos and Digel, Ilya and Temiz Artmann, Ayseg{\"u}l}, title = {Nanostructured carbon-based column for LPS/protein adsorption : [abstract]}, year = {2009}, abstract = {The absence of a general method for endotoxin removal from liquid interfaces gives an opportunity to find new methods and materials to overcome this gap. Activated nanostructured carbon is a promising material that showed good adsorption properties due to its vast pore network and high surface area. The aim of this study is to find the adsorption rates for a carboneous material produced at different temperatures, as well as to reveal possible differences between the performance of the material for each of the adsorbates used during the study (hemoglobin, serum albumin and lipopolysaccharide, LPS).}, subject = {Kohlenstofffaser}, language = {en} } @inproceedings{SchoeningAbdelghani2012, author = {Sch{\"o}ning, Michael Josef and Abdelghani, Adnane}, title = {Nanoscale Science and Technology (NS\&T'12) : Proceedings Book Humboldt Kolleg <2012, Tunisia> ; Tunisia, 17-19 March, 2012 / ed. by Michael J. Sch{\"o}ning ; Adnane Abdelghani}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-3544}, year = {2012}, abstract = {Proceedings of the 2nd Humboldt Kolleg, Hammamet, Tunisia Organizer: Alexander von Humboldt Stiftung, Germany. pdf 184 p. Welcome Address Dear Participants, Welcome to the 2nd Humboldt Kolleg in "Nanoscale Science and Technology" (NS\&T'12) in Tunisia, sponsored by the "Alexander von Humboldt" foundation. The NS\&T'12 multidisciplinary scientific program includes seven "hot" topics dealing with "Nanoscale Science and Technology" covering basic and application-oriented research as well as industrial (market) aspects: - Molecular Biophyics, Spectroscopy Techniques, Imaging Microscopy - Nanomaterials Synthesis for Medicine and Bio-chemical Sensors - Nanostructures, Semiconductors, Photonics and Nanodevices - New Technologies in Market Industry - Environment, Electro-chemistry, Bio-polymers and Fuel Cells - Nanomaterials, Photovoltaic, Modelling, Quantum Physics - Microelectronics, Sensors Networks and Embedded Systems We are deeply indebted to all members of the Scientific Committee and General Chairs for joint Sessions and to all speakers and chairmen, who have dedicated invaluable time and efforts for the realization of this event. On behalf of the Organizing Committee, we are cordially inviting you to join the conference and hope that your stay will be fruitful, rewarding and enjoyable. Prof. Dr. Michael J. Sch{\"o}ning, Prof. Dr. Adnane Abdelghani}, subject = {Biosensor}, language = {en} } @article{KarschuckSchmidtAchtsnichtetal.2023, author = {Karschuck, Tobias and Schmidt, Stefan and Achtsnicht, Stefan and Poghossian, Arshak and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Multiplexing system for automated characterization of a capacitive field-effect sensor array}, series = {Physica Status Solidi A}, volume = {220}, journal = {Physica Status Solidi A}, number = {22}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6300 (Print)}, doi = {10.1002/pssa.202300265}, pages = {7 Seiten}, year = {2023}, abstract = {In comparison to single-analyte devices, multiplexed systems for a multianalyte detection offer a reduced assay time and sample volume, low cost, and high throughput. Herein, a multiplexing platform for an automated quasi-simultaneous characterization of multiple (up to 16) capacitive field-effect sensors by the capacitive-voltage (C-V) and the constant-capacitance (ConCap) mode is presented. The sensors are mounted in a newly designed multicell arrangement with one common reference electrode and are electrically connected to the impedance analyzer via the base station. A Python script for the automated characterization of the sensors executes the user-defined measurement protocol. The developed multiplexing system is tested for pH measurements and the label-free detection of ligand-stabilized, charged gold nanoparticles.}, language = {en} } @inproceedings{BukhariYang2006, author = {Bukhari, Syed Faisal Ahmed and Yang, Wuqiang}, title = {Multi-interface level sensors and new development in monitoring and control of oil separators}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1498}, year = {2006}, abstract = {In the oil industry, huge saving may be made if suitable multi-interface level measurement systems are employed for effectively monitoring crude oil separators and efficient control of their operation. A number of techniques, e.g. externally mounted displacers, differential pressure transmitters and capacitance rod devices, have been developed to measure the separation process with gas, oil, water and other components. Because of the unavailability of suitable multi-interface level measurement systems, oil separators are currently operated by the trial-and-error approach. In this paper some conventional techniques, which have been used for level measurement in industry, and new development are discussed.}, subject = {Biosensor}, language = {en} } @inproceedings{ChaiybounTrauteKiesewetteretal.2006, author = {Chaiyboun, Ali and Traute, R{\"u}diger and Kiesewetter, Olaf and Ahlers, Simon and M{\"u}ller, Gerhard and Doll, Theodor}, title = {Modular analytical multicomponent analysis in gas sensor arrays}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1358}, year = {2006}, abstract = {A multi-sensor system is a chemical sensor system which quantitatively and qualitatively records gases with a combination of cross-sensitive gas sensor arrays and pattern recognition software. This paper addresses the issue of data analysis for identification of gases in a gas sensor array. We introduce a software tool for gas sensor array configuration and simulation. It concerns thereby about a modular software package for the acquisition of data of different sensors. A signal evaluation algorithm referred to as matrix method was used specifically for the software tool. This matrix method computes the gas concentrations from the signals of a sensor array. The software tool was used for the simulation of an array of five sensors to determine gas concentration of CH4, NH3, H2, CO and C2H5OH. The results of the present simulated sensor array indicate that the software tool is capable of the following: (a) identify a gas independently of its concentration; (b) estimate the concentration of the gas, even if the system was not previously exposed to this concentration; (c) tell when a gas concentration exceeds a certain value. A gas sensor data base was build for the configuration of the software. With the data base one can create, generate and manage scenarios and source files for the simulation. With the gas sensor data base and the simulation software an on-line Web-based version was developed, with which the user can configure and simulate sensor arrays on-line.}, subject = {Biosensor}, language = {en} } @misc{Schreiber2016, author = {Schreiber, Marc}, title = {Mit Maximum-Entropie das Parsing nat{\"u}rlicher Sprache erlernen}, publisher = {FH Aachen}, address = {Aachen}, pages = {23 Seiten}, year = {2016}, abstract = {F{\"u}r die Verarbeitung von nat{\"u}rlicher Sprache ist ein wichtiger Zwischenschritt das Parsing, bei dem f{\"u}r S{\"a}tze der nat{\"u}rlichen Sprache Ableitungsb{\"a}ume bestimmt werden. Dieses Verfahren ist vergleichbar zum Parsen formaler Sprachen, wie z. B. das Parsen eines Quelltextes. Die Parsing-Methoden der formalen Sprachen, z. B. Bottom-up-Parser, k{\"o}nnen nicht auf das Parsen der nat{\"u}rlichen Sprache {\"u}bertragen werden, da keine Formalisierung der nat{\"u}rlichen Sprachen existiert [3, 12, 23, 30]. In den ersten Programmen, die nat{\"u}rliche Sprache verarbeiten [32, 41], wurde versucht die nat{\"u}rliche Sprache mit festen Regelmengen zu verarbeiten. Dieser Ansatz stieß jedoch schnell an seine Grenzen, da die Regelmenge nicht vollst{\"a}ndig sowie nicht minimal ist und wegen der ben{\"o}tigten Menge an Regeln schwer zu verwalten ist. Die Korpuslinguistik [22] bot die M{\"o}glichkeit, die Regelmenge durch Supervised-Machine-Learning-Verfahren [2] abzul{\"o}sen. Teil der Korpuslinguistik ist es, große Textkorpora zu erstellen und diese mit sprachlichen Strukturen zu annotieren. Zu diesen Strukturen geh{\"o}ren sowohl die Wortarten als auch die Ableitungsb{\"a}ume der S{\"a}tze. Vorteil dieser Methodik ist es, dass repr{\"a}sentative Daten zur Verf{\"u}gung stehen. Diese Daten werden genutzt, um mit Supervised-Machine-Learning-Verfahren die Gesetzm{\"a}ßigkeiten der nat{\"u}rliche Sprachen zu erlernen. Das Maximum-Entropie-Verfahren ist ein Supervised-Machine-Learning-Verfahren, das genutzt wird, um nat{\"u}rliche Sprache zu erlernen. Ratnaparkhi [25] nutzt Maximum-Entropie, um Ableitungsb{\"a}ume f{\"u}r S{\"a}tze der nat{\"u}rlichen Sprache zu erlernen. Dieses Verfahren macht es m{\"o}glich, die nat{\"u}rliche Sprache (abgebildet als Σ∗) trotz einer fehlenden formalen Grammatik zu parsen.}, language = {de} } @inproceedings{TymeckiGlabKoncki2006, author = {Tymecki, Lukasz and Glab, Stanislaw and Koncki, Robert}, title = {Miniaturized, planar ion-selective electrodes fabricated by means of thick-film technology}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1506}, year = {2006}, abstract = {Various planar technologies are employed for developing solid-state sensors having low cost, small size and high reproducibility; thin- and thick-film technologies are most suitable for such productions. Screen-printing is especially suitable due to its simplicity, low-cost, high reproducibility and efficiency in large-scale production. This technology enables the deposition of a thick layer and allows precise pattern control. Moreover, this is a highly economic technology, saving large amounts of the used inks. In the course of repetitions of the film-deposition procedure there is no waste of material due to additivity of this thick-film technology. Finally, the thick films can be easily and quickly deposited on inexpensive substrates. In this contribution, thick-film ion-selective electrodes based on ionophores as well as crystalline ion-selective materials dedicated for potentiometric measurements are demonstrated. Analytical parameters of these sensors are comparable with those reported for conventional potentiometric electrodes. All mentioned thick-film strip electrodes have been totally fabricated in only one, fully automated thickfilm technology, without any additional manual, chemical or electrochemical steps. In all cases simple, inexpensive, commercially available materials, i.e. flexible, plastic substrates and easily cured polymer-based pastes were used.}, subject = {Biosensor}, language = {en} } @article{MolinnusIkenJohnenetal.2022, author = {Molinnus, Denise and Iken, Heiko and Johnen, Anna Lynn and Richstein, Benjamin and Hellmich, Lena and Poghossian, Arshak and Knoch, Joachim and Sch{\"o}ning, Michael Josef}, title = {Miniaturized pH-Sensitive Field-Effect Capacitors with Ultrathin Ta₂O₅ Films Prepared by Atomic Layer Deposition}, series = {physica status solidi (a) applications and materials science}, volume = {219}, journal = {physica status solidi (a) applications and materials science}, number = {8}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.202100660}, pages = {7 Seiten}, year = {2022}, abstract = {Miniaturized electrolyte-insulator-semiconductor capacitors (EISCAPs) with ultrathin gate insulators have been studied in terms of their pH-sensitive sensor characteristics: three different EISCAP systems consisting of Al-p-Si-Ta2O5(5 nm), Al-p-Si-Si3N4(1 or 2 nm)-Ta2O5 (5 nm), and Al-p-Si-SiO2(3.6 nm)-Ta2O5(5 nm) layer structures are characterized in buffer solution with different pH values by means of capacitance-voltage and constant capacitance method. The SiO2 and Si3N4 gate insulators are deposited by rapid thermal oxidation and rapid thermal nitridation, respectively, whereas the Ta2O5 film is prepared by atomic layer deposition. All EISCAP systems have a clear pH response, favoring the stacked gate insulators SiO2-Ta2O5 when considering the overall sensor characteristics, while the Si3N4(1 nm)-Ta2O5 stack delivers the largest accumulation capacitance (due to the lower equivalent oxide thickness) and a higher steepness in the slope of the capacitance-voltage curve among the studied stacked gate insulator systems.}, language = {en} } @inproceedings{PlatenPoghossianSchoening2006, author = {Platen, Johannes and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Microstructured Nanostructures - nanostructuring by means of conventional photolithography and layer-expansion technique}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1477}, year = {2006}, abstract = {A new and simple method for nanostructuring using conventional photolithography and layer expansion or pattern-size reduction technique is presented, which can further be applied for the fabrication of different nanostructures and nano-devices. The method is based on the conversion of a photolithographically patterned metal layer to a metal-oxide mask with improved pattern-size resolution using thermal oxidation. With this technique, the pattern size can be scaled down to several nanometer dimensions. The proposed method is experimentally demonstrated by preparing nanostructures with different configurations and layouts, like circles, rectangles, trapezoids, "fluidic-channel"-, "cantilever"- and meander-type structures.}, subject = {Biosensor}, language = {en} } @inproceedings{SchreiberKraftZuendorf2017, author = {Schreiber, Marc and Kraft, Bodo and Z{\"u}ndorf, Albert}, title = {Metrics Driven Research Collaboration: Focusing on Common Project Goals Continuously}, series = {39th International Conference on Software Engineering, May 20-28, 2017 - Buenos Aires, Argentina}, booktitle = {39th International Conference on Software Engineering, May 20-28, 2017 - Buenos Aires, Argentina}, pages = {8 Seiten}, year = {2017}, abstract = {Research collaborations provide opportunities for both practitioners and researchers: practitioners need solutions for difficult business challenges and researchers are looking for hard problems to solve and publish. Nevertheless, research collaborations carry the risk that practitioners focus on quick solutions too much and that researchers tackle theoretical problems, resulting in products which do not fulfill the project requirements. In this paper we introduce an approach extending the ideas of agile and lean software development. It helps practitioners and researchers keep track of their common research collaboration goal: a scientifically enriched software product which fulfills the needs of the practitioner's business model. This approach gives first-class status to application-oriented metrics that measure progress and success of a research collaboration continuously. Those metrics are derived from the collaboration requirements and help to focus on a commonly defined goal. An appropriate tool set evaluates and visualizes those metrics with minimal effort, and all participants will be pushed to focus on their tasks with appropriate effort. Thus project status, challenges and progress are transparent to all research collaboration members at any time.}, language = {en} } @inproceedings{BaronasIvanauskasKulys2006, author = {Baronas, Romas and Ivanauskas, Feliksas and Kulys, Juozas}, title = {Mathematical modeling of biosensors based on an array of enzyme microreactors}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1569}, year = {2006}, abstract = {This paper presents a two-dimensional-in-space mathematical model of biosensors based on an array of enzyme microreactors immobilised on a single electrode. The modeling system acts under amperometric conditions. The microreactors were modeled by particles and by strips. The model is based on the diffusion equations containing a nonlinear term related to the Michaelis-Menten kinetics of the enzymatic reaction. The model involves three regions: an array of enzyme microreactors where enzyme reaction as well as mass transport by diffusion takes place, a diffusion limiting region where only the diffusion takes place, and a convective region, where the analyte concentration is maintained constant. Using computer simulation, the influence of the geometry of the microreactors and of the diffusion region on the biosensor response was investigated. The digital simulation was carried out using the finite difference technique.}, subject = {Biosensor}, language = {en} } @inproceedings{KatzWillner2006, author = {Katz, Eugenii and Willner, Itamar}, title = {Magneto-controlled quantized electron transfer to surface-confined redox units and metal nanoparticles}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1528}, year = {2006}, abstract = {Hydrophobic magnetic nanoparticles (NPs) consisting of undecanoate-capped magnetite (Fe3O4, average diameter ca. 5 nm) are used to control quantized electron transfer to surface-confined redox units and metal NPs. A two-phase system consisting of an aqueous electrolyte solution and a toluene phase that includes the suspended undecanoatecapped magnetic NPs is used to control the interfacial properties of the electrode surface. The attracted magnetic NPs form a hydrophobic layer on the electrode surface resulting in the change of the mechanisms of the surface-confined electrochemical processes. A quinone-monolayer modified Au electrode demonstrates an aqueous-type of the electrochemical process (2e-+2H+ redox mechanism) for the quinone units in the absence of the hydrophobic magnetic NPs, while the attraction of the magnetic NPs to the surface results in the stepwise single-electron transfer mechanism characteristic of a dry nonaqueous medium. Also, the attraction of the hydrophobic magnetic NPs to the Au electrode surface modified with Au NPs (ca. 1.4 nm) yields a microenvironment with a low dielectric constant that results in the single-electron quantum charging of the Au NPs.}, subject = {Biosensor}, language = {en} } @article{Staat2005, author = {Staat, Manfred}, title = {Local and global collapse pressure of longitudinally flawed pipes and cylindrical vessels}, year = {2005}, abstract = {Limit loads can be calculated with the finite element method (FEM) for any component, defect geometry, and loading. FEM suggests that published long crack limit formulae for axial defects under-estimate the burst pressure for internal surface defects in thick pipes while limit loads are not conservative for deep cracks and for pressure loaded crack-faces. Very deep cracks have a residual strength, which is modelled by a global collapse load. These observations are combined to derive new analytical local and global collapse loads. The global collapse loads are close to FEM limit analyses for all crack dimensions.}, subject = {Finite-Elemente-Methode}, language = {en} } @inproceedings{StaatHeitzerHicken1998, author = {Staat, Manfred and Heitzer, M. and Hicken, E. F.}, title = {LISA, ein europ{\"a}isches Projekt zur direkten Berechnung der Tragf{\"a}higkeit duktiler Strukturen}, year = {1998}, abstract = {Traglast- und Einspielanalysen sind vereinfachte doch exakte Verfahren der Plastizit{\"a}t, die neben ausreichender Verformbarkeit keine einschr{\"a}nkenden Voraussetzungen beinhalten. Die Vereinfachungen betreffen die Beschaffung der Daten und Modelle f{\"u}r Details der Lastgeschichte und des Stoffverhaltens. Anders als die klassische Behandlung nichtlinearer Probleme der Strukturmechanik f{\"u}hrt die Methode auf Optimierungsprobleme. Diese sind bei realistischen FEM-Modellen sehr groß. Das hat die industrielle Anwendung der Traglast- und Einspielanalysen stark verz{\"o}gert. Diese Situation wird durch das Brite-EuRam Projekt LISA grundlegend ge{\"a}ndert. Die Autoren m{\"o}chten der Europ{\"a}ischen Kommission an dieser Stelle f{\"u}r die F{\"o}rderung ausdr{\"u}cklich danken. In LISA entsteht auf der Basis des industriellen FEM-Programms PERMAS ein Verfahren zur direkten Berechnung der Tragf{\"a}higkeit duktiler Strukturen. Damit kann der Betriebsbereich von Komponenten und Bauwerken auf den plastischen Bereich erweitert werden, ohne den Aufwand gegen{\"u}ber elastischen Analysen wesentlich zu erh{\"o}hen. Die beachtlichen Rechenzeitgewinne erlauben Parameterstudien und die Berechnung von Interaktionsdiagrammen, die einen schnellen {\"U}berblick {\"u}ber m{\"o}gliche Betriebsbereiche vermitteln. Es zeigt sich, daß abh{\"a}ngig von der Komponente und ihren Belastungen teilweise entscheidende Sicherheitsgewinne zur Erweiterung der Betriebsbereiche erzielt werden k{\"o}nnen. Das Vorgehen erfordert vom Anwender oft ein gewisses Umdenken. Es werden keine Spannungen berechnet, um damit Sicherheit und Lebensdauer zu interpretieren. Statt dessen berechnet man direkt die gesuchte Sicherheit. Der Post-Prozessor wird nur noch zur Modell- und Rechenkontrolle ben{\"o}tigt. Das Vorgehen ist {\"a}nhlich der Stabilit{\"a}tsanalyse (Knicken, Beulen). Durch namhafte industrielle Projektpartner werden Validierung und die Anwendbarkeit auf eine breite Palette technischer Probleme garantiert. Die ebenfalls in LISA geplante Zuverl{\"a}ssigkeitsanalyse ist erst auf der Basis direkter Verfahren effektiv m{\"o}glich. Ohne Traglast- und Einspielanalyse ist plastische Strukturoptimierung auch heute kaum durchf{\"u}hrbar.}, subject = {Finite-Elemente-Methode}, language = {de} } @inproceedings{StaatHeitzerHicken1999, author = {Staat, Manfred and Heitzer, Michael and Hicken, E. F.}, title = {LISA - ein europ{\"a}isches Projekt zur FEM-basierten Traglast- und Einspielanalyse}, year = {1999}, abstract = {Traglast- und Einspielanalysen sind vereinfachte doch exakte Verfahren der Plastizit{\"a}t, die neben ausreichender Verformbarkeit keine einschr{\"a}nkenden Voraussetzungen beinhalten. Die Vereinfachungen betreffen die Beschaffung der Daten und Modelle f{\"u}r Details der Lastgeschichte und des Stoffverhaltens. Anders als die klassische Behandlung nichtlinearer Probleme der Strukturmechanik f{\"u}hrt die Methode auf Optimierungsprobleme. Diese sind bei realistischen FEM-Modellen sehr groß. Das hat die industrielle Anwendung der Traglast- und Einspielanalysen stark verz{\"o}gert. Diese Situation wird durch das Brite-EuRam Projekt LISA grundlegend ge{\"a}ndert. In LISA entsteht auf der Basis des industriellen FEM-Programms PERMAS ein Verfahren zur direkten Berechnung der Tragf{\"a}higkeit duktiler Strukturen. Damit kann der Betriebsbereich von Komponenten und Bauwerken auf den plastischen Bereich erweitert werden, ohne den Aufwand gegen{\"u}ber elastischen Analysen wesentlich zu erh{\"o}hen. Die beachtlichen Rechenzeitgewinne erlauben Parameterstudien und die Berechnung von Interaktionsdiagrammen, die einen schnellen {\"U}berblick {\"u}ber m{\"o}gliche Betriebsbereiche vermitteln. Es zeigt sich, daß abh{\"a}ngig von der Komponente und ihren Belastungen teilweise entscheidende Sicherheitsgewinne zur Erweiterung der Betriebsbereiche erzielt werden k{\"o}nnen. Das Vorgehen erfordert vom Anwender oft ein gewisses Umdenken. Es werden keine Spannungen berechnet, um damit Sicherheit und Lebensdauer zu interpretieren. Statt dessen berechnet man direkt die gesuchte Sicherheit. Der Post-Prozessor wird nur noch zur Modell- und Rechenkontrolle ben{\"o}tigt. Das Vorgehen ist {\"a}hnlich der Stabilit{\"a}tsanalyse (Knicken, Beulen). Durch namhafte industrielle Projektpartner werden Validierung und die Anwendbarkeit auf eine breite Palette technischer Probleme garantiert. Die ebenfalls in LISA entwickelten Zuverl{\"a}ssigkeitsanalysen sind nichlinear erst auf der Basis direkter Verfahren effektiv m{\"o}glich. Ohne Traglast- und Einspielanalyse ist plastische Strukturoptimierung auch heute kaum durchf{\"u}hrbar. Auf die vorgesehenen Erweiterungen der Werkstoffmodellierung f{\"u}r nichtlineare Verfestigung und f{\"u}r Sch{\"a}digung konnte hier nicht eingegangen werden. Es herrscht ein deutlicher Mangel an Experimenten zum Nachweis der Grenzen zwischen elastischem Einspielen und dem Versagen durch LCF oder durch Ratchetting.}, subject = {Einspielen }, language = {de} } @article{Staat2001, author = {Staat, Manfred}, title = {LISA - a European project for FEM-based limit and shakedown analysis}, year = {2001}, abstract = {The load-carrying capacity or the safety against plastic limit states are the central questions in the design of structures and passive components in the apparatus engineering. A precise answer is most simply given by limit and shakedown analysis. These methods can be based on static and kinematic theorems for lower and upper bound analysis. Both may be formulated as optimization problems for finite element discretizations of structures. The problems of large-scale analysis and the extension towards realistic material modelling will be solved in a European research project. Limit and shakedown analyses are briefly demonstrated with illustrative examples.}, subject = {Einspielen }, language = {en} } @inproceedings{StaatTranPham2008, author = {Staat, Manfred and Tran, Thanh Ngoc and Pham, Phu Tinh}, title = {Limit and shakedown reliability analysis by nonlinear programming}, year = {2008}, abstract = {7th International Conference on Reliability of Materials and Structures (RELMAS 2008). June 17 - 20, 2008 ; Saint Petersburg, Russia. pp 354-358. Reprint with corrections in red Introduction Analysis of advanced structures working under extreme heavy loading such as nuclear power plants and piping system should take into account the randomness of loading, geometrical and material parameters. The existing reliability are restricted mostly to the elastic working regime, e.g. allowable local stresses. Development of the limit and shakedown reliability-based analysis and design methods, exploiting potential of the shakedown working regime, is highly needed. In this paper the application of a new algorithm of probabilistic limit and shakedown analysis for shell structures is presented, in which the loading and strength of the material as well as the thickness of the shell are considered as random variables. The reliability analysis problems may be efficiently solved by using a system combining the available FE codes, a deterministic limit and shakedown analysis, and the First and Second Order Reliability Methods (FORM/SORM). Non-linear sensitivity analyses are obtained directly from the solution of the deterministic problem without extra computational costs.}, subject = {Finite-Elemente-Methode}, language = {en} } @article{StaatHeitzer1997, author = {Staat, Manfred and Heitzer, M.}, title = {Limit and Shakedown Analysis Using a General Purpose Finite Element Code}, series = {Proceedings of NAFEMS World Congress '97 on Design, Simulation \& Optimisation : reliability \& applicability of computational methods ; Stuttgart, Germany, 9 - 11 April 1997}, journal = {Proceedings of NAFEMS World Congress '97 on Design, Simulation \& Optimisation : reliability \& applicability of computational methods ; Stuttgart, Germany, 9 - 11 April 1997}, publisher = {NAFEMS}, address = {Glasgow}, isbn = {1-87437-620-4}, pages = {522 -- 533}, year = {1997}, language = {en} } @inproceedings{StaatHeitzer1997, author = {Staat, Manfred and Heitzer, Michael}, title = {Limit and shakedown analysis for plastic design}, year = {1997}, abstract = {Limit and shakedown theorems are exact theories of classical plasticity for the direct computation of safety factors or of the load carrying capacity under constant and varying loads. Simple versions of limit and shakedown analysis are the basis of all design codes for pressure vessels and pipings. Using Finite Element Methods more realistic modeling can be used for a more rational design. The methods can be extended to yield optimum plastic design. In this paper we present a first implementation in FE of limit and shakedown analyses for perfectly plastic material. Limit and shakedown analyses are done of a pipe-junction and a interaction diagram is calculated. The results are in good correspondence with the analytic solution we give in the appendix.}, subject = {Einspielen }, language = {en} }