@inproceedings{PoghossianAbouzarSchoening2012, author = {Poghossian, Arshak and Abouzar, Maryam H. and Sch{\"o}ning, Michael Josef}, title = {(Bio-­)chemical sensor array based on nanoplate SOI capacitors}, series = {Nanoscale Science and Technology (NS\&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012}, booktitle = {Nanoscale Science and Technology (NS\&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012}, editor = {Abdelghani, Adnane and Sch{\"o}ning, Michael Josef}, pages = {31 -- 31}, year = {2012}, language = {en} } @inproceedings{BohrnStuetzFleischeretal.2012, author = {Bohrn, U. and St{\"u}tz, E. and Fleischer, M. and Sch{\"o}ning, Michael Josef and Wagner, P.}, title = {Towards a paradigm change - mammalian cells as sensitive biosensor layers for the detection of unexpected toxic substances in air}, series = {Nanoscale Science and Technology (NS\&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012}, booktitle = {Nanoscale Science and Technology (NS\&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012}, editor = {Abdelghani, Adnane and Sch{\"o}ning, Michael Josef}, pages = {44 -- 44}, year = {2012}, language = {en} } @inproceedings{ReisertGeisslerFloerkeetal.2012, author = {Reisert, Steffen and Geissler, H. and Fl{\"o}rke, R. and Weiler, C. and Wagner, P. and Sch{\"o}ning, Michael Josef}, title = {Characterisation of aseptic sterilisation processes using an electronic nose}, series = {Nanoscale Science and Technology (NS\&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012}, booktitle = {Nanoscale Science and Technology (NS\&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012}, editor = {Abdelghani, Adnane and Sch{\"o}ning, Michael Josef}, pages = {45 -- 45}, year = {2012}, language = {en} } @inproceedings{SchusserLeinhosPoghossianetal.2012, author = {Schusser, Sebastian and Leinhos, Marcel and Poghossian, Arshak and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Biopolymer-degradation monitoring by chip-­based impedance spectroscopy technique}, series = {Nanoscale Science and Technology (NS\&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012}, booktitle = {Nanoscale Science and Technology (NS\&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012}, editor = {Abdelghani, Adnane and Sch{\"o}ning, Michael Josef}, pages = {47 -- 47}, year = {2012}, language = {en} } @article{AbouzarPoghossianCherstvyetal.2012, author = {Abouzar, Maryam H. and Poghossian, Arshak and Cherstvy, Andrey G. and Pedraza, Angela M. and Ingebrandt, Sven and Sch{\"o}ning, Michael Josef}, title = {Label-free electrical detection of DNA by means of field-effect nanoplate capacitors: Experiments and modeling}, series = {Physica Status Solidi (a)}, volume = {209}, journal = {Physica Status Solidi (a)}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201100710}, pages = {925 -- 934}, year = {2012}, abstract = {Label-free electrical detection of consecutive deoxyribonucleic acid (DNA) hybridization/denaturation by means of an array of individually addressable field-effect-based nanoplate silicon-on-insulator (SOI) capacitors modified with gold nanoparticles (Au-NP) is investigated. The proposed device detects charge changes on Au-NP/DNA hybrids induced by the hybridization or denaturation event. DNA hybridization was performed in a high ionic-strength solution to provide a high hybridization efficiency. On the other hand, to reduce the screening of the DNA charge by counter ions and to achieve a high sensitivity, the sensor signal induced by the hybridization and denaturation events was measured in a low ionic-strength solution. High sensor signals of about 120, 90, and 80 mV were registered after the DNA hybridization, denaturation, and re-hybridization events, respectively. Fluorescence microscopy has been applied as reference method to verify the DNA immobilization, hybridization, and denaturation processes. An electrostatic charge-plane model for potential changes at the gate surface of a nanoplate field-effect sensor induced by the DNA hybridization has been developed taking into account both the Debye length and the distance of the DNA charge from the gate surface.}, language = {en} } @article{SchubaHoefkenSchaefer2012, author = {Schuba, Marko and H{\"o}fken, H. and Schaefer, T.}, title = {Smartphone Forensik}, series = {Hakin9 : Practical Protection (2012)}, journal = {Hakin9 : Practical Protection (2012)}, publisher = {-}, isbn = {1733-7186}, pages = {10 -- 20}, year = {2012}, language = {de} } @inproceedings{YoshinobuMiyamotoWagneretal.2012, author = {Yoshinobu, Tatsuo and Miyamoto, Ko-Ichiro and Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Miniaturized and high-speed chemical imaging systems}, series = {Nano-Biomedical Engineering 2012. Proceedings of the Tohoku University Global Centre of Excellence Programme, Sakura Hall, Tohoku University, Sendai Japan, 5 - 6 March 2012}, booktitle = {Nano-Biomedical Engineering 2012. Proceedings of the Tohoku University Global Centre of Excellence Programme, Sakura Hall, Tohoku University, Sendai Japan, 5 - 6 March 2012}, editor = {Yamaguchi, Takami}, publisher = {World Scientific}, address = {Singapur}, doi = {10.1142/9781848169067_0045}, pages = {386 -- 395}, year = {2012}, language = {en} } @article{ChwallekEngelenOswaldetal.2012, author = {Chwallek, Constanze and Engelen, Andreas and Oswald, Monika and Brettel, Malte}, title = {Die Wir­kung des F{\"u}h­rungs­ver­hal­tens des Top-Ma­nage­ments auf die un­ter­neh­me­ri­sche Ori­en­tie­rung - ein 5-L{\"a}n­der-Ver­gleich}, series = {Zfbf : Schmalenbachs Zeitschrift f{\"u}r betriebswirtschaftliche Forschung}, journal = {Zfbf : Schmalenbachs Zeitschrift f{\"u}r betriebswirtschaftliche Forschung}, number = {2}, publisher = {Springer Fachmedien}, address = {Wiesbaden}, issn = {0341-2687}, pages = {138 -- 165}, year = {2012}, language = {de} } @article{BackesAdamGottschaldetal.2012, author = {Backes, Klaus and Adam, Mario and Gottschald, Beng Jonas and Faber, Christian and Henneb{\"o}hl, Friedrich-Gregor and Lanz, Marco and Anthrakidis, Anette}, title = {KWKK-Anlagen im Feldtest. Optimaler Betrieb durch Verbesserungen bei Regelung und Hydraulik}, series = {Die K{\"a}lte- und Klimatechnik}, journal = {Die K{\"a}lte- und Klimatechnik}, number = {2}, publisher = {Gentner}, address = {Stuttgart}, issn = {0343-2246}, year = {2012}, language = {de} } @article{StaatTrenzLohmannetal.2012, author = {Staat, Manfred and Trenz, Eva and Lohmann, Philipp and Frotscher, Ralf and Klinge, Uwe and Tabaza, Ruth and Kirschner-Hermanns, Ruth}, title = {New measurements to compare soft tissue anchoring systems in pelvic floor surgery}, series = {Journal of Biomedical Materials Research Part B: Applied Biomaterials}, volume = {100B}, journal = {Journal of Biomedical Materials Research Part B: Applied Biomaterials}, number = {4}, publisher = {Wiley}, address = {Hoboken, NJ}, issn = {1552-4981}, doi = {10.1002/jbm.b.32654}, pages = {924 -- 933}, year = {2012}, abstract = {Suburethral slings as well as different meshes are widely used treating stress urinary incontinence and prolaps in women. With the development of MiniSlings and special meshes using less alloplastic material anchorage systems become more important to keep devices in place and to put some tension especially on the MiniSlings. To date, there are many different systems of MiniSlings of different companies on the market which differ in the structure of the used meshes and anchors. A new objective measurement method to compare different properties of MiniSling systems (mesh and anchor) is presented in this article. Ballistic gelatine acts as soft tissue surrogate. Significant differences in parameters like pull-out strength of anchors or shrinkage of meshes under loading conditions have been determined. The form and size of the anchors as well as the structural stability of the meshes are decisive for a proper integration. The tested anchorings sytems showed markedly different mechanical function at their respective load bearing capacity. As the stable fixation of the device in tissue is a prerequisite for a permanet reinforcement, the proposed test system permits further optimisation of anchor and mesh devices to improve the success of the surgical treatment}, language = {en} } @article{BaeckerRaueSchusseretal.2012, author = {B{\"a}cker, Matthias and Raue, Markus and Schusser, Sebastian and Jeitner, C. and Breuer, L. and Wagner, P. and Poghossian, Arshak and F{\"o}rster, Arnold and Mang, Thomas and Sch{\"o}ning, Michael Josef}, title = {Microfluidic chip with integrated microvalves based on temperature- and pH-responsive hydrogel thin films}, series = {Physica Status Solidi (a)}, volume = {209}, journal = {Physica Status Solidi (a)}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201100763}, pages = {839 -- 845}, year = {2012}, abstract = {Two types of microvalves based on temperature-responsive poly(N-isopropylacrylamide) (PNIPAAm) and pH-responsive poly(sodium acrylate) (PSA) hydrogel films have been developed and tested. The PNIPAAm and PSA hydrogel films were prepared by means of in situ photopolymerization directly inside the fluidic channel of a microfluidic chip fabricated by combining Si and SU-8 technologies. The swelling/shrinking properties and height changes of the PNIPAAm and PSA films inside the fluidic channel were studied at temperatures of deionized water from 14 to 36 °C and different pH values (pH 3-12) of Titrisol buffer, respectively. Additionally, in separate experiments, the lower critical solution temperature (LCST) of the PNIPAAm hydrogel was investigated by means of a differential scanning calorimetry (DSC) and a surface plasmon resonance (SPR) method. Mass-flow measurements have shown the feasibility of the prepared hydrogel films to work as an on-chip integrated temperature- or pH-responsive microvalve capable to switch the flow channel on/off.}, language = {en} } @book{Vismann2012, author = {Vismann, Ulrich}, title = {Wendehorst Bautechnische Zahlentafeln / hrsg. von Ulrich Vismann in Verbindung mit dem DIN Deutsches Institut f{\"u}r Normung e.V. Herwig Baumgartner ...}, edition = {34., vollst. {\"u}berarb. und erw. Aufl.}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2}, pages = {1688 S. : graph. Darst.}, year = {2012}, language = {de} } @incollection{Vismann2012, author = {Vismann, Ulrich}, title = {Stahlbeton- und Spannbetonbau nach Eurocode 2}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_12}, pages = {601 -- 775}, year = {2012}, abstract = {Die bauaufsichtliche Einf{\"u}hrung der Eurocodes steht unmittelbar bevor. F{\"u}r den Bereich des Stahl- und Spannbetonbaus soll die Anwendung zum 1. Juli 2012 verbindlich sein, d. h. mit diesem Stichtag sollte nur noch der Eurocode 2 (DIN EN 1992-1-1, Ausgabe Januar 2011) mit seinem zugeh{\"o}rigen nationalen Anhang (DIN EN 1992-1-1/NA, Ausgabe Januar 2011) Verwendung finden, die DIN 1045-1 wird zur{\"u}ckgezogen. Bereits seit M{\"a}rz 2010 gilt eine {\"U}bergangsphase, ist der die Anwendung des Eurocodes alternativ zur DIN 1045-1 als bauaufsichtlich gleichwertige L{\"o}sung m{\"o}glich.}, language = {de} } @incollection{Vismann2012, author = {Vismann, Ulrich}, title = {Beton nach DIN 1045-2}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_11}, pages = {571 -- 600}, year = {2012}, language = {de} } @incollection{Feiser2012, author = {Feiser, Johannes}, title = {Geotechnik}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_17}, pages = {1221 -- 1332}, year = {2012}, abstract = {In der nationalen und der europ{\"a}ischen Normung werden die geotechnischen Aufgaben zwecks Mindestanforderungen an Baugrunduntersuchung, rechnerische Nachweise und {\"U}berwachung der Ausf{\"u}hrung in drei Klassen (Kategorien) eingeteilt. Sie richten sich nach der zu erwartenden Reaktion des Baugrundes, nach dem geotechnischen Schwierigkeitsgrad des Tragwerks und seiner Einfl{\"u}sse auf dieUmgebung.}, language = {de} } @incollection{Strohmeier2012, author = {Strohmeier, Andreas}, title = {Siedlungswasserwirtschaft}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_19}, pages = {1393 -- 1498}, year = {2012}, language = {de} } @incollection{Biener2012, author = {Biener, Ernst}, title = {Abfallwirtschaft}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_20}, pages = {1499 -- 1540}, year = {2012}, language = {de} } @incollection{LohseStroetmann2012, author = {Lohse, Wolfram and Stroetmann, Richard}, title = {Stahlbau}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_13}, pages = {777 -- 1019}, year = {2012}, language = {de} } @article{AggarwalDhimanKumaretal.2012, author = {Aggarwal, P. and Dhiman, S. and Kumar, G. and Scherer, Ulrich W. and Singla, M. L. and Srivastava, A.}, title = {Optical study of poly(ethyleneterephthalate) modified by different ionizing radiation dose}, series = {Indian Journal of Pure and Applied Physics}, volume = {50}, journal = {Indian Journal of Pure and Applied Physics}, number = {2}, issn = {0019-5596}, pages = {129 -- 132}, year = {2012}, abstract = {Thin films of poly(ethyleneterephthalate) [PET]were exposed to radiation dose ranging from 10 to 30 kGy by using gamma rays in the range 12.8-177.8 MGy using swift light ions of hydrogen. There was no effect of the radiation dose on the optical behaviour of PET as a result of exposure to radiation dose up to 30 kGy brought about by gamma rays but a significant decrease in the optical band gap values was observed when PET was exposed to swift light ions of hydrogen. The data obtained are discussed in terms of optical studies carried out on PET using swift heavy ions.}, language = {en} } @article{SpelthahnSchubertSchoening2012, author = {Spelthahn, Heiko and Schubert, J{\"u}rgen and Sch{\"o}ning, Michael Josef}, title = {D{\"u}nnschichtsensoren f{\"u}r die Schwermetallanalytik}, series = {GIT : Labor-Fachzeitschrift}, volume = {56}, journal = {GIT : Labor-Fachzeitschrift}, number = {4}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0016-3538}, pages = {285 -- 287}, year = {2012}, abstract = {Die Detektion von Schadstoffen repr{\"a}sentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte D{\"u}nnschichtsensoren bieten eine kosteng{\"u}nstige M{\"o}glichkeit, „online"-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuf{\"u}hren. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgl{\"a}sern zur Detektion von Schwermetallen in w{\"a}ssrigen Medien vorgestellt.}, language = {en} }