@article{HonarvarfardGamellaChannaveerappaetal.2017, author = {Honarvarfard, Elham and Gamella, Maria and Channaveerappa, Devika and Darie, Costel C. and Poghossian, Arshak and Sch{\"o}ning, Michael Josef and Katz, Evgeny}, title = {Electrochemically Stimulated Insulin Release from a Modified Graphene-functionalized Carbon Fiber Electrode}, series = {Electroanalysis}, volume = {29}, journal = {Electroanalysis}, number = {6}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-4109}, doi = {10.1002/elan.201700095}, pages = {1543 -- 1553}, year = {2017}, abstract = {A graphene-functionalized carbon fiber electrode was modified with adsorbed polyethylenimine to introduce amino functionalities and then with trigonelline and 4-carboxyphenylboronic acid covalently bound to the amino groups. The trigonelline species containing quarterized pyridine groups produced positive charge on the electrode surface regardless of the pH value, while the phenylboronic acid species were neutral below pH 8 and negatively charged above pH 9 (note that their pKa=8.4). The total charge on the monolayer-modified electrode was positive at the neutral pH and negative at pH > 9. Note that 4-carboxyphenylboronic acid was attached to the electrode surface in molar excess to trigonelline, thus allowing the negative charge to dominate on the electrode surface at basic pH. Negatively charged fluorescent dye-labeled insulin (insulin-FITC) was loaded on the modified electrode surface at pH 7.0 due to its electrostatic attraction to the positively charged interface. The local pH in close vicinity to the electrode surface was increased to ca. 9-10 due to consumption of H+ ions upon electrochemical reduction of oxygen proceeding at the potential of -1.0 V (vs. Ag/AgCl) applied on the modified electrode. The process resulted in recharging of the electrode surface to the negative value due to the formation of the negative charge on the phenylboronic acid groups, thus resulting in the electrostatic repulsion of insulin-FITC and stimulating its release from the electrode surface. The insulin release was characterized by fluorescence spectroscopy (using the FITC-labeled insulin), by electrochemical measurements on an iridium oxide, IrOx, electrode and by mass spectrometry. The graphene-functionalized carbon fiber electrode demonstrated significant advantages in the signal-stimulated insulin release comparing with the carbon fiber electrode without the graphene species.}, language = {en} } @inproceedings{AbelBoninAlbrachtetal.2010, author = {Abel, Thomas and Bonin, Dominik and Albracht, Kirsten and Zeller, Sebastian and Br{\"u}ggemann, Gert-Peter and Burkett, Brendan and Str{\"u}der, Heiko K.}, title = {Kinematic profile of the elite handcyclist}, series = {28th International Conference on Biomechanics in Sports, Marquette, Michigan, USA, July 19 - 23, 2010}, booktitle = {28th International Conference on Biomechanics in Sports, Marquette, Michigan, USA, July 19 - 23, 2010}, issn = {1999-4168}, pages = {140 -- 141}, year = {2010}, language = {en} } @inproceedings{BraunsteinGoldmannAlbrachtetal.2013, author = {Braunstein, Bjoern and Goldmann, Jan-Peter and Albracht, Kirsten and Sanno, Maximilian and Willwacher, Steffen and Heinrich, Kai and Herrmann, Volker and Br{\"u}ggemann, Gert-Peter}, title = {Joint specific contribution of mechanical power and work during acceleration and top speed in elite sprinters}, series = {31 International Conference on Biomechanics in Sports, Taipei, Taiwan, July 07 - July 22, 2013}, booktitle = {31 International Conference on Biomechanics in Sports, Taipei, Taiwan, July 07 - July 22, 2013}, issn = {1999-4168}, year = {2013}, language = {en} } @inproceedings{DroszezSannoGoldmannetal.2016, author = {Droszez, Anna and Sanno, Maximilian and Goldmann, Jan-Peter and Albracht, Kirsten and Br{\"u}ggemann, Gerd-Peter and Braunstein, Bjoern}, title = {Differences between take-off behavior during vertical jumps and two artistic elements}, series = {34th International Conference of Biomechanics in Sport, Tsukuba, Japan, July 18-22, 2016}, booktitle = {34th International Conference of Biomechanics in Sport, Tsukuba, Japan, July 18-22, 2016}, issn = {1999-4168}, pages = {577 -- 580}, year = {2016}, language = {en} } @inproceedings{GoldmannBraunsteinHeinrichetal.2015, author = {Goldmann, Jan-Peter and Braunstein, Bjoern and Heinrich, Kai and Sanno, Maximilian and St{\"a}udle, Benjamin and Ritzdorf, Wolfgang and Br{\"u}ggemann, Gert-Peter and Albracht, Kirsten}, title = {Joint work of the take-off leg during elite high jump}, series = {Proceedings of the 33th International Conference on Biomechanics in Sports (ISBS)}, booktitle = {Proceedings of the 33th International Conference on Biomechanics in Sports (ISBS)}, pages = {3 S.}, year = {2015}, language = {en} } @article{ZangeSchopenAlbrachtetal.2017, author = {Zange, Jochen and Schopen, Kathrin and Albracht, Kirsten and Gerlach, Darius A. and Frings-Meuthen, Petra and Maffiuletti, Nicola A. and Bloch, Wilhelm and Rittweger, J{\"o}rn}, title = {Using the Hephaistos orthotic device to study countermeasure effectiveness of neuromuscular electrical stimulation and dietary lupin protein supplementation, a randomised controlled trial}, series = {Plos one}, volume = {12}, journal = {Plos one}, number = {2}, doi = {10.1371/journal.pone.0171562}, year = {2017}, language = {en} } @inproceedings{KolditzAlbinFasseetal.2015, author = {Kolditz, Melanie and Albin, Thivaharan and Fasse, Alessandro and Br{\"u}ggemann, Gert-Peter and Abel, Dirk and Albracht, Kirsten}, title = {Simulative Analysis of Joint Loading During Leg Press Exercise for Control Applications}, series = {IFAC-PapersOnLine}, volume = {48}, booktitle = {IFAC-PapersOnLine}, number = {20}, doi = {10.1016/j.ifacol.2015.10.179}, pages = {435 -- 440}, year = {2015}, language = {en} } @inproceedings{KolditzAlbrachtFasseetal.2015, author = {Kolditz, Melanie and Albracht, Kirsten and Fasse, Alessandro and Albin, Thivaharan and Br{\"u}ggemann, Gert-Peter and Abel, Dirk}, title = {Evaluation of an industrial robot as a leg press training device}, series = {XV International Symposium on Computer Simulation in Biomechanics July 9th - 11th 2015, Edinburgh, UK}, booktitle = {XV International Symposium on Computer Simulation in Biomechanics July 9th - 11th 2015, Edinburgh, UK}, pages = {41 -- 42}, year = {2015}, language = {en} } @phdthesis{Albracht2010, author = {Albracht, Kirsten}, title = {Influence of mechanical properties of the leg extensor muscletendon units on running economy}, publisher = {Deutsche Sporthochschule K{\"o}ln}, address = {K{\"o}ln}, pages = {X, 1221 Bl. : graph. Darst.}, year = {2010}, language = {en} } @article{HacklWegmannKahmannetal.2017, author = {Hackl, Michael and Wegmann, Kilian and Kahmann, Stephanie Lucina and Heinze, Nicolai and Staat, Manfred and Neiss, Wolfram F. and Scaal, Martin and M{\"u}ller, Lars P.}, title = {Radial shortening osteotomy reduces radiocapitellar contact pressures while preserving valgus stability of the elbow}, series = {Knee Surgery, Sports Traumatology, Arthroscopy}, volume = {25}, journal = {Knee Surgery, Sports Traumatology, Arthroscopy}, number = {7}, publisher = {Springer}, address = {Berlin}, issn = {1433-7347}, doi = {10.1007/s00167-017-4468-z}, pages = {2280 -- 2288}, year = {2017}, language = {en} } @article{PoghossianWernerBuniatyanetal.2017, author = {Poghossian, Arshak and Werner, Frederik and Buniatyan, V. V. and Wagner, Torsten and Miamoto, K. and Yoshinobu, T. and Sch{\"o}ning, Michael Josef}, title = {Towards addressability of light-addressable potentiometric sensors: Shunting effect of non-illuminated region and cross-talk}, series = {Sensor and Actuators B: Chemical}, journal = {Sensor and Actuators B: Chemical}, number = {244}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2017.01.047}, pages = {1071 -- 1079}, year = {2017}, abstract = {The LAPS (light-addressable potentiometric sensor) platform is one of the most attractive approaches for chemical and biological sensing with many applications ranging from pH and ion/analyte concentration measurements up to cell metabolism detection and chemical imaging. However, although it is generally accepted that LAPS measurements are spatially resolved, the light-addressability feature of LAPS devices has not been discussed in detail so far. In this work, an extended electrical equivalent-circuit model of the LAPS has been presented, which takes into account possible cross-talk effects due to the capacitive coupling of the non-illuminated region. A shunting effect of the non-illuminated area on the measured photocurrent and addressability of LAPS devices has been studied. It has been shown, that the measured photocurrent will be determined not only by the local interfacial potential in the illuminated region but also by possible interfacial potential changes in the non-illuminated region, yielding cross-talk effects. These findings were supported by the experimental investigations of a penicillin-sensitive multi-spot LAPS and a metal-insulator-semiconductor LAPS as model systems.}, language = {en} } @article{JahnkeRousselHombachetal.2016, author = {Jahnke, Siegfried and Roussel, Johanna and Hombach, Thomas and Kochs, Johannes and Fischbach, Andreas and Huber, Gregor and Scharr, Hanno}, title = {phenoSeeder - A robot system for automated handling and phenotyping of individual seeds}, series = {Plant physiology}, volume = {172}, journal = {Plant physiology}, number = {3}, publisher = {Oxford University Press}, address = {Oxford}, issn = {0032-0889}, doi = {10.1104/pp.16.01122}, pages = {1358 -- 1370}, year = {2016}, abstract = {The enormous diversity of seed traits is an intriguing feature and critical for the overwhelming success of higher plants. In particular, seed mass is generally regarded to be key for seedling development but is mostly approximated by using scanning methods delivering only two-dimensional data, often termed seed size. However, three-dimensional traits, such as the volume or mass of single seeds, are very rarely determined in routine measurements. Here, we introduce a device named phenoSeeder, which enables the handling and phenotyping of individual seeds of very different sizes. The system consists of a pick-and-place robot and a modular setup of sensors that can be versatilely extended. Basic biometric traits detected for individual seeds are two-dimensional data from projections, three-dimensional data from volumetric measures, and mass, from which seed density is also calculated. Each seed is tracked by an identifier and, after phenotyping, can be planted, sorted, or individually stored for further evaluation or processing (e.g. in routine seed-to-plant tracking pipelines). By investigating seeds of Arabidopsis (Arabidopsis thaliana), rapeseed (Brassica napus), and barley (Hordeum vulgare), we observed that, even for apparently round-shaped seeds of rapeseed, correlations between the projected area and the mass of seeds were much weaker than between volume and mass. This indicates that simple projections may not deliver good proxies for seed mass. Although throughput is limited, we expect that automated seed phenotyping on a single-seed basis can contribute valuable information for applications in a wide range of wild or crop species, including seed classification, seed sorting, and assessment of seed quality.}, language = {en} } @inproceedings{PoghossianBronderSchejaetal.2016, author = {Poghossian, Arshak and Bronder, Thomas and Scheja, S. and Wu, Chunsheng and Metzger-Boddien, C. and Keusgen, M. and Sch{\"o}ning, Michael Josef}, title = {Label-free Electrostatic Detection of DNA Amplification by PCR Using Capacitive Field-effect Devices}, series = {Procedia Engineering}, volume = {Vol. 168}, booktitle = {Procedia Engineering}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2016.11.512}, pages = {514 -- 517}, year = {2016}, abstract = {A capacitive field-effect EIS (electrolyte-insulator-semiconductor) sensor modified with a positively charged weak polyelectrolyte of poly(allylamine hydrochloride) (PAH)/single-stranded probe DNA (ssDNA) bilayer has been used for a label-free electrostatic detection of pathogen-specific DNA amplification via polymerase chain reaction (PCR). The sensor is able to distinguish between positive and negative PCR solutions, to detect the existence of target DNA amplicons in PCR samples and thus, can be used as tool for a quick verification of DNA amplification and the successful PCR process.}, language = {en} } @article{KatzPoghossianSchoening2017, author = {Katz, Evgeny and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Enzyme-based logic gates and circuits - analytical applications and interfacing with electronics}, series = {Analytical and Bioanalytical Chemistry}, volume = {409}, journal = {Analytical and Bioanalytical Chemistry}, publisher = {Springer}, address = {Berlin}, issn = {1618-2650}, doi = {10.1007/s00216-016-0079-7}, pages = {81 -- 94}, year = {2017}, abstract = {The paper is an overview of enzyme-based logic gates and their short circuits, with specific examples of Boolean AND and OR gates, and concatenated logic gates composed of multi-step enzyme-biocatalyzed reactions. Noise formation in the biocatalytic reactions and its decrease by adding a "filter" system, converting convex to sigmoid response function, are discussed. Despite the fact that the enzyme-based logic gates are primarily considered as components of future biomolecular computing systems, their biosensing applications are promising for immediate practical use. Analytical use of the enzyme logic systems in biomedical and forensic applications is discussed and exemplified with the logic analysis of biomarkers of various injuries, e.g., liver injury, and with analysis of biomarkers characteristic of different ethnicity found in blood samples on a crime scene. Interfacing of enzyme logic systems with modified electrodes and semiconductor devices is discussed, giving particular attention to the interfaces functionalized with signal-responsive materials. Future perspectives in the design of the biomolecular logic systems and their applications are discussed in the conclusion.}, language = {en} } @inproceedings{BaeckerKochGeigeretal.2016, author = {B{\"a}cker, Matthias and Koch, C. and Geiger, F. and Eber, F. and Gliemann, H. and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {A New Class of Biosensors Based on Tobacco Mosaic Virus and Coat Proteins as Enzyme Nanocarrier}, series = {Procedia Engineering}, volume = {Vol. 168}, booktitle = {Procedia Engineering}, issn = {1877-7058}, doi = {10.1016/j.proeng.2016.11.228}, pages = {618 -- 621}, year = {2016}, language = {en} } @article{AlbrachtArampatzis2006, author = {Albracht, Kirsten and Arampatzis, Adamantios}, title = {Influence of the mechanical properties of the muscle-tendon unit on force generation in runners with different running economy}, series = {Biological Cybernetics}, volume = {95}, journal = {Biological Cybernetics}, number = {1}, issn = {1432-0770}, doi = {10.1007/s00422-006-0070-z}, pages = {87 -- 96}, year = {2006}, language = {en} } @article{ArampatzisKaramanidisAlbracht2007, author = {Arampatzis, Adamantios and Karamanidis, Kiros and Albracht, Kirsten}, title = {Adaptational responses of the human Achilles tendon by modulation of the applied cyclic strain magnitude}, series = {Journal of Experimental Biology}, volume = {210}, journal = {Journal of Experimental Biology}, number = {15}, issn = {0022-0949}, doi = {10.1242/jeb.003814}, pages = {2743 -- 2753}, year = {2007}, language = {en} } @article{AlbrachtArampatzisBaltzopoulos2008, author = {Albracht, Kirsten and Arampatzis, A. and Baltzopoulos, V.}, title = {Assessment of muscle volume and physiological cross-sectional area of the human triceps surae muscle in vivo}, series = {Journal of Biomechanics}, volume = {41}, journal = {Journal of Biomechanics}, issn = {0021-9290}, doi = {10.1016/j.jbiomech.2008.04.020}, pages = {2211 -- 2218}, year = {2008}, language = {en} } @article{ArampatzisKaramanidisMademlietal.2009, author = {Arampatzis, Adamantios and Karamanidis, Kiros and Mademli, Lida and Albracht, Kirsten}, title = {Plasticity of the human tendon to short and long-term mechanical loading}, series = {Exercise and Sport Sciences Reviews}, volume = {37}, journal = {Exercise and Sport Sciences Reviews}, number = {2}, issn = {1538-3008}, doi = {10.1097/JES.0b013e31819c2e1d}, pages = {66 -- 72}, year = {2009}, language = {en} } @article{AggeloussisGiannakouAlbrachtetal.2010, author = {Aggeloussis, Nickos and Giannakou, Erasmia and Albracht, Kirsten and Arampatzis, Adamantios}, title = {Reproducibility of fascicle length and pennation angle of gastrocnemius medialis in human gait in vivo}, series = {Gait and Posture}, volume = {31}, journal = {Gait and Posture}, number = {1}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0966-6362}, doi = {10.1016/j.gaitpost.2009.08.249}, pages = {73 -- 77}, year = {2010}, abstract = {The purpose of the current study was to examine the reproducibility of fascicle length and pennation angle of gastrocnemius medialis while human walking. To the best of our knowledge, this is the first study of the reproducibility of fascicle length and pennation angle of gastrocnemius medialis in vivo during human gait. Twelve males performed 10 gait trials on a treadmill, in 2 separate days. B-mode ultrasonography, with the ultrasound probe firmly adjusted in the transverse and frontal planes using a special cast, was used to measure the fascicle length and the pennation angle of the gastrocnemius medialis (GM). A Vicon 624 system with three cameras operating at 120 Hz was also used to record the ankle and knee joint angles. The results showed that measurements of fascicle length and pennation angle showed high reproducibility during the gait cycle, both within the same day and between different days. Moreover, the root mean square differences between the repeated waveforms of both variables were very small, compared with their ranges (fascicle length: RMS = ∼3 mm, range: 38-63 mm; pennation angle: RMS = ∼1.5°, range: 22-32°). However, their reproducibility was lower compared to the joint angles. It was found that representative data have to be derived by a wide number of gait trials (fascicle length ∼six trials, pennation angle more than 10 trials), to assure the reliability of the fascicle length and pennation angle in human gait.}, language = {en} }