@incollection{AkimbekovZhanadilovnaUalievaetal.2020, author = {Akimbekov, Nuraly S. and Zhanadilovna, Abdieva G. and Ualieva, Perizat S. and Abaihanovna, Zhusipova D. and Digel, Ilya and Savitskaya, Irina S. and Zhubanova, Azhar Achmet}, title = {Functionalization of Carbon Based Wound Dressings with Antimicrobial Phytoextracts for Bioactive Treatment of Septic Wounds}, series = {Carbon Nanomaterials in Biomedicine and the Environment}, booktitle = {Carbon Nanomaterials in Biomedicine and the Environment}, publisher = {Jenny Stanford Publishing}, address = {Singapore}, isbn = {978-981-4800-27-3}, doi = {10.1201/9780429428647-11}, pages = {211 -- 228}, year = {2020}, abstract = {The treatment of septic wounds with curative dressings based on biocomposites containing sage and marigold phytoextracts was effective in in vitro and in vivo experiments. These dressings caused the purification of the wound surface from purulent-necrotic masses three days earlier than in the other experimental groups. The consequence of an increase in incidents of severe course of the wound and the observed tendency to increase the number of adverse effects is the development of long-term recurrent wound processes. To treat purulent wounds, the following tactics were used: The purulent wounds of animals were covered with the examined wound dressing, and then the next day samples were taken, the procedure was performed once in 2 days. To obtain the active nanostructured sorbents such as carbonized rice husks, they are functionalized with biologically active components possessing antimicrobial, anti-inflammatory, antitoxic, immunomodulating, antiallergic and other types of properties.}, language = {en} } @article{AkimbekovZhubanovaMansurovetal.2010, author = {Akimbekov, Nuraly S. and Zhubanova, A. A. and Mansurov, Z. A. and Digel, Ilya and Artmann, Gerhard and Temiz Artmann, Ayseg{\"u}l}, title = {Use of Carbonized Rise Shell for the local treatment of wounds}, series = {Eurasian ChemTech Journal}, volume = {12}, journal = {Eurasian ChemTech Journal}, number = {2}, publisher = {Institute of Combustion Problems}, address = {Almaty}, issn = {2522-4867}, doi = {10.18321/ectj35}, pages = {133 -- 138}, year = {2010}, abstract = {On the model of musculocutaneous wound in rats, the effect of applicative sorption by carbonized rise shell (CRS) on the healing of festering wound was studied. It has been shown, that cytological changes end with rapid scar formation. The use of CRS at the period of severe purulent wound contributes to its favorable course, prevents the development of complications of the animals from sepsis.}, language = {en} } @misc{AlKaidyTippkoetterKaiseretal.2014, author = {Al-Kaidy, H. and Tippk{\"o}tter, Nils and Kaiser, P. and Wollny, S. and Ulber, Roland}, title = {Aufreinigung von Cytochrom P450BMP mittels magnetischer Partikel und die enzymatische Synthese von 9, 10-Dihydroxystearins{\"a}ure}, series = {Chemie Ingenieur Technik}, volume = {86}, journal = {Chemie Ingenieur Technik}, number = {9}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.201450420}, pages = {1420}, year = {2014}, abstract = {Cytochrom P450 sind H{\"a}m-Proteine, die zur Enzymklasse der Oxidoreduktasen (EC 1.14.xy) geh{\"o}ren. Eine wichtige Reaktion ist die Hydroxylierung nichtaktivierter C-H-Bindungen, die in technischen Systemen von großem Interesse ist. Durch die Verwendung von M-IDA-2-Partikeln ist eine direkte Aufreinigung mit gleichzeitiger Immobilisierung und die Applikation der Enzyme aus dem Zelllysat m{\"o}glich. Damit ist das Verfahren mehr als f{\"u}nf Stunden schneller als die konventionelle Chromatographie und mehr als 80 \% der Aufreinigungszeit wird gespart. Mit dem isolierten nativen Enzym konnte die Plattformchemikalie 9,10-Dihydroxystearins{\"a}ure aus {\"O}ls{\"a}ure hergestellt werden. Unter anderem f{\"u}r die Kunststoffindustrie k{\"o}nnen aus diesem Produkt wichtige Monomere wie z. B. Azelains{\"a}ure hergestellt werden. Die Bildung des Produkts erfolgt in einem zweiphasigen Reaktionssystem an der Grenzfl{\"a}che zwischen dem {\"O}l und der w{\"a}ssrigen Phase als Feststoff. Um das immobilisierte Enzym aktiv in die obere Phase zu transportieren, wurde eine neue magnetische Mischvorrichtung entwickelt. Das Reaktionsprodukt wurde mit NMR, GC-MS und HPLC-MS analysiert und mit einem chemisch synthetisierten Standard von 9,10-Dihydroxystearins{\"a}ure verglichen. Derzeit werden Studien des immobilisierten H{\"a}ms des Enzyms durchgef{\"u}hrt.}, language = {de} } @inproceedings{AlKaidyUlberTippkoetter2014, author = {Al-Kaidy, H. and Ulber, Roland and Tippk{\"o}tter, Nils}, title = {A platform technology for the automated reaction control in magnetizable micro-fluidic droplets}, series = {Biomaterials - made in bioreactors : book of abstracts, May 26 - 28, 2014, Radisson Blu Park Hotel and Conference Dentre, Radebeul, Germany}, booktitle = {Biomaterials - made in bioreactors : book of abstracts, May 26 - 28, 2014, Radisson Blu Park Hotel and Conference Dentre, Radebeul, Germany}, publisher = {DECHEMA}, address = {Frankfurt am Main}, pages = {21 -- 22}, year = {2014}, language = {en} } @misc{AlKaidyUlberTippkoetter2014, author = {Al-Kaidy, H. and Ulber, Roland and Tippk{\"o}tter, Nils}, title = {Eine Plattform-Technologie f{\"u}r die automatisierte Reaktionsf{\"u}hrung in magnetisierbaren mikrofluidischen Tropfen}, series = {Chemie Ingenieur Technik}, volume = {86}, journal = {Chemie Ingenieur Technik}, number = {9}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.201450424}, pages = {1419 -- 1420}, year = {2014}, abstract = {{\"U}blicherweise werden biotechnologische Reaktionssysteme im mikrofluidischen Maßstab in vorstrukturierten Bauteilen oder mit auf Wellplatten basierenden Robotersystemen realisiert. In dem hier vorgestellten System werden chemische oder biologische Reaktionen mit magnetischen Mikroreaktoren (MR) durchgef{\"u}hrt, bei denen hydrophobe magnetische Mikropartikel einen w{\"a}ssrigen Kern umschließen. Solche MR bieten eine gute Kontrolle der Reaktionsbedingungen, eine verbesserte Sicherheit und Portabilit{\"a}t. Die neue Plattformtechnologie erm{\"o}glicht die zweidimensionale Bewegung der magnetischen MR auf einer planaren Ebene. Oberhalb oder unterhalb der Plattform werden Magnetfeldgradienten zum Manipulieren und Bewegen eines oder mehrerer magnetischer MR erzeugt. Die optimal auf die MR wirkenden magnetischen Kr{\"a}fte werden experimentell ermittelt und simuliert. Die Aktivierung der Magnetfelder wird automatisiert durch elektrische Spulen mit Eisenkern bzw. Neodymmagnet gesteuert. Angewendet wurde das System beim reversiblen {\"O}ffnen von MR, um z. B. Reaktionspartner in den w{\"a}ssrigen Kern zu injizieren oder Proben zu entnehmen. Ferner wurde Lac-case A und b-Glucosidase auf einer Quarzglasoberfl{\"a}che immobilisiert und mit einem MR zum Reagieren gebracht. Weiterhin wurden MR fusioniert und so ein w{\"a}ssriger Kern bestehend aus Laccase mit einem aus dem entsprechenden Substrat Syringaldazin vereint.}, language = {de} } @article{AlKaidyDuweHusteretal.2014, author = {Al-Kaidy, Huschyar and Duwe, Anna and Huster, Manuel and Muffler, Kai and Schlegel, Christin and Sieker, Tim and Stadtm{\"u}ller, Ralf and Tippk{\"o}tter, Nils and Ulber, Roland}, title = {Biotechnologie und Bioverfahrenstechnik - Vom ersten Ullmanns Artikel bis hin zu aktuellen Forschungsthemen}, series = {Chemie Ingenieur Technik}, volume = {86}, journal = {Chemie Ingenieur Technik}, number = {12}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.201400083}, pages = {2215 -- 2225}, year = {2014}, abstract = {Biotechnologie und die mit ihr verbundenen technischen Prozesse pr{\"a}gen seit Jahrtausenden die Entwicklung der Menschheit. Ausgehend von empirischen Verfahren, insbesondere zur Herstellung von Lebensmitteln und t{\"a}glichen Gebrauchsg{\"u}tern, haben sich diese Disziplinen zu einem der innovativsten Zukunftsfelder entwickelt. Durch das immer detailliertere Verst{\"a}ndnis zellul{\"a}rer Vorg{\"a}nge k{\"o}nnen mittlerweile Produktionsst{\"a}mme gezielt optimiert werden. Im Zusammenspiel mit moderner Prozesstechnik k{\"o}nnen so eine Vielzahl von Bulk- und Feinchemikalien sowie Pharmazeutika effizient hergestellt werden. In diesem Artikel werden exemplarisch einige der aktuellen Trends vorgestellt.}, language = {de} } @article{AlKaidyDuweHusteretal.2015, author = {Al-Kaidy, Huschyar and Duwe, Anna and Huster, Manuel and Muffler, Kai and Schlegel, Christin and Tim, Sieker and Stadtm{\"u}ller, Ralf and Tippk{\"o}tter, Nils and Ulber, Roland}, title = {Biotechnology and bioprocess engineering - from the first ullmann's article to recent trends}, series = {ChemBioEng Reviews}, volume = {2}, journal = {ChemBioEng Reviews}, number = {3}, publisher = {Wiley}, address = {Weinheim}, doi = {10.1002/cben.201500008}, pages = {175 -- 184}, year = {2015}, abstract = {For several thousand years, biotechnology and its associated technical processes have had a great impact on the development of mankind. Based on empirical methods, in particular for the production of foodstuffs and daily commodities, these disciplines have become one of the most innovative future issues. Due to the increasing detailed understanding of cellular processes, production strains can now be optimized. In combination with modern bioprocesses, a variety of bulk and fine chemicals as well as pharmaceuticals can be produced efficiently. In this article, some of the current trends in biotechnology are discussed.}, language = {en} } @article{AlKaidyKuthanHeringetal.2016, author = {Al-Kaidy, Huschyar and Kuthan, Kai and Hering, Thomas and Tippk{\"o}tter, Nils}, title = {Aqueous droplets used as enzymatic microreactors and their electromagnetic actuation}, series = {Journal of Visualized Experiments}, journal = {Journal of Visualized Experiments}, number = {Issue 126}, issn = {1940-087X}, doi = {10.3791/54643}, year = {2016}, abstract = {For the successful implementation of microfluidic reaction systems, such as PCR and electrophoresis, the movement of small liquid volumes is essential. In conventional lab-on-a-chip-platforms, solvents and samples are passed through defined microfluidic channels with complex flow control installations. The droplet actuation platform presented here is a promising alternative. With it, it is possible to move a liquid drop (microreactor) on a planar surface of a reaction platform (lab-in-a-drop). The actuation of microreactors on the hydrophobic surface of the platform is based on the use of magnetic forces acting on the outer shell of the liquid drops which is made of a thin layer of superhydrophobic magnetite particles. The hydrophobic surface of the platform is needed to avoid any contact between the liquid core and the surface to allow a smooth movement of the microreactor. On the platform, one or more microreactors with volumes of 10 µL can be positioned and moved simultaneously. The platform itself consists of a 3 x 3 matrix of electrical double coils which accommodate either neodymium or iron cores. The magnetic field gradients are automatically controlled. By variation of the magnetic field gradients, the microreactors' magnetic hydrophobic shell can be manipulated automatically to move the microreactor or open the shell reversibly. Reactions of substrates and corresponding enzymes can be initiated by merging the microreactors or bringing them into contact with surface immobilized catalysts.}, language = {en} } @article{AlKaidyTippkoetter2016, author = {Al-Kaidy, Huschyar and Tippk{\"o}tter, Nils}, title = {Superparamagnetic hydrophobic particles as shell material for digital microfluidic droplets and proof-of-principle reaction assessments with immobilized laccase}, series = {Engineering in Life Sciences}, volume = {16}, journal = {Engineering in Life Sciences}, number = {3}, publisher = {Wiley-VCH}, address = {Weinheim}, doi = {10.1002/elsc.201400124}, pages = {222 -- 230}, year = {2016}, abstract = {In the field of biotechnology and molecular biology, the use of small liquid volumes has significant advantages. In particular, screening and optimization runs with acceptable amounts of expensive and hardly available catalysts, reagents, or biomolecules are feasible with microfluidic technologies. The presented new microfluidic system is based on the inclusion of small liquid volumes by a protective shell of magnetizable microparticles. Hereby, discrete aqueous microreactor drops with volumes of 1-30 μL can be formed on a simple planar surface. A digital movement and manipulation of the microreactor is performed by overlapping magnetic forces. The magnetic forces are generated by an electrical coil matrix positioned below a glass plate. With the new platform technology, several discrete reaction compartments can be moved simultaneously on one surface. Due to the magnetic fields, the reactors can even be merged to initiate reactions by mixing or positioned above surface-immobilized catalysts and then opened by magnetic force. Comparative synthesis routes of the magnetizable shell particles and superhydrophobic glass slides including their performance and stability with the reaction platform are described. The influence of diffusive mass transport during the catalyzed reaction is discussed by evaluation finite element model of the microreactor. Furthermore, a first model dye reaction of the enzyme laccase has been established.}, language = {en} } @misc{AlKaidyTippkoetterUlber2016, author = {Al-Kaidy, Huschyar and Tippk{\"o}tter, Nils and Ulber, Roland}, title = {Vorrichtung und Verfahren zur Bestimmung des Kontaktwinkels eines Fl{\"u}ssigk{\"o}rpers mit einer Festk{\"o}rperoberfl{\"a}che}, year = {2016}, abstract = {Die vorliegende Erfindung betrifft eine Vorrichtung und ein Verfahren zur Bestimmung des Kontaktwinkels eines fl{\"u}ssigen oder mit Fl{\"u}ssigkeit gef{\"u}llten K{\"o}rpers. Dieser besteht aus einem Tr{\"a}ger (1) und einer damit verbundenen, in einem Winkelbereich von mehr als 0 ° bis maximal 90 ° neigbaren Ebene (8) mit einer darin ausgebildeten Abrollbahn (9) f{\"u}r den fl{\"u}ssigen oder mit Fl{\"u}ssigkeit gef{\"u}llten K{\"o}rper. An der Ebene (8) sind mehrere Sensoren (11,12) zur Erfassung der Rolldauer des K{\"o}rpers entlang der Rollstrecke angeordnet. Erfindungsgem{\"a}ß ist vorgesehen, dass die Einstellung des Neigungswinkels der Ebene (8) {\"u}ber ein Winkelmessger{\"a}t (10) erfolgt, wodurch ein Abrollwinkel erfassbar ist, bei dem der K{\"o}rper in Bewegung ger{\"a}t. Aus der Rolldauer, der Rollstrecke und dem Abrollwinkel wird der Kontaktwinkel des K{\"o}rpers ermittelt.}, language = {de} } @misc{AlKaidyTippkoetterUlber2014, author = {Al-Kaidy, Huschyar and Tippk{\"o}tter, Nils and Ulber, Roland}, title = {Vorrichtung und Verfahren zur Bestimmung des Kontaktwinkels eines fl{\"u}ssigen oder mit Fl{\"u}ssigkeit gef{\"u}llten K{\"o}rpers [Offenlegungsschrift]}, publisher = {Deutsches Patent- und Markenamt}, address = {M{\"u}nchen}, pages = {13 Seiten}, year = {2014}, abstract = {Die vorliegende Erfindung betrifft eine Vorrichtung und ein Verfahren zur Bestimmung des Kontaktwinkels eines fl{\"u}ssigen oder mit Fl{\"u}ssigkeit gef{\"u}llten K{\"o}rpers. Dieser besteht aus einem Tr{\"a}ger (1) und einer damit verbundenen, in einem Winkelbereich von mehr als 0° bis maximal 90° neigbaren Ebene (8) mit einer darin ausgebildeten Abrollbahn (9) f{\"u}r den fl{\"u}ssigen oder mit Fl{\"u}ssigkeit gef{\"u}llten K{\"o}rper. An der Ebene (8) sind mehrere Sensoren (11, 12) zur Erfassung der Rolldauer des K{\"o}rpers entlang der Rollstrecke angeordnet. Erfindungsgem{\"a}ß ist vorgesehen, dass die Einstellung des Neigungswinkels der Ebene (8) {\"u}ber ein Winkelmessger{\"a}t (10) erfolgt, wodurch ein Abrollwinkel erfassbar ist, bei dem der K{\"o}rper in Bewegung ger{\"a}t. Aus der Rolldauer, der Rollstrecke und dem Abrollwinkel wird der Kontaktwinkel des K{\"o}rpers ermittelt.}, language = {de} } @misc{AlKaidyTippkoetterUlber2013, author = {Al-Kaidy, Huschyar and Tippk{\"o}tter, Nils and Ulber, Roland}, title = {A system and a method for the implementation of chemical, biological or physical reactions [Europ{\"a}ische Patentanmeldung]}, publisher = {Europ{\"a}isches Patentamt}, address = {Den Hague}, pages = {16 Seiten}, year = {2013}, abstract = {The invention relates to a system for the implementation of chemical, biological or physical reactions, consisting of - one or more magnetic micro-reactors, each comprising a shell made of hydrophobic magnetic nanoparticles encapsulating an aqueous core, - a plane platform comprising a surface to receive the micro-reactors, - a source that generates a magnetic field above or underneath the platform for manipulating the one or more hydrophobic magnetic micro-reactors, or for moving them along the surface of the platform from one position to another position, characterized in that the aqueous core of the one or more magnetic micro-reactors contains a reaction solution or buffer, and wherein the magnetic field generated by the source correlates to a defined position on the surface of the platform.}, language = {en} } @article{AlbannaConzenWeissetal.2016, author = {Albanna, W. and Conzen, C. and Weiss, M. and Clusmann, H. and Fuest, M. and Mueller, M. and Brockmann, M.A. and Vilser, W. and Schmidt-Trucks{\"a}ss, A. and Hoellig, A. and Seiz, M. and Thom{\´e}, C. and Kotliar, Konstantin and Schubert, G.A.}, title = {Retinal Vessel Analysis (RVA) in the context of subarachnoid hemorrhage: A proof of concept study}, series = {PLoS ONE}, volume = {11}, journal = {PLoS ONE}, number = {7}, publisher = {PLOS}, address = {San Francisco}, issn = {1932-6203}, doi = {10.1371/journal.pone.0158781}, pages = {13 Seiten}, year = {2016}, abstract = {Background Timely detection of impending delayed cerebral ischemia after subarachnoid hemorrhage (SAH) is essential to improve outcome, but poses a diagnostic challenge. Retinal vessels as an embryological part of the intracranial vasculature are easily accessible for analysis and may hold the key to a new and non-invasive monitoring technique. This investigation aims to determine the feasibility of standardized retinal vessel analysis (RVA) in the context of SAH. Methods In a prospective pilot study, we performed RVA in six patients awake and cooperative with SAH in the acute phase (day 2-14) and eight patients at the time of follow-up (mean 4.6±1.7months after SAH), and included 33 age-matched healthy controls. Data was acquired using a manoeuvrable Dynamic Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and neurovascular coupling. Results Image quality was satisfactory in the majority of cases (93.3\%). In the acute phase after SAH, retinal arteries were significantly dilated when compared to the control group (124.2±4.3MU vs 110.9±11.4MU, p<0.01), a difference that persisted to a lesser extent in the later stage of the disease (122.7±17.2MU, p<0.05). Testing for neurovascular coupling showed a trend towards impaired primary vasodilation and secondary vasoconstriction (p = 0.08, p = 0.09 resp.) initially and partial recovery at the time of follow-up, indicating a relative improvement in a time-dependent fashion. Conclusion RVA is technically feasible in patients with SAH and can detect fluctuations in vessel diameter and autoregulation even in less severely affected patients. Preliminary data suggests potential for RVA as a new and non-invasive tool for advanced SAH monitoring, but clinical relevance and prognostic value will have to be determined in a larger cohort.}, language = {en} } @article{AlbannaConzenWeissetal.2021, author = {Albanna, Walid and Conzen, Catharina and Weiss, Miriam and Seyfried, Katharina and Kotliar, Konstantin and Schmidt, Tobias Philip and Kuerten, David and Hescheler, J{\"u}rgen and Bruecken, Anne and Schmidt-Trucks{\"a}ss, Arno and Neumaier, Felix and Wiesmann, Martin and Clusmann, Hans and Schubert, Gerrit Alexander}, title = {Non-invasive assessment of neurovascular coupling after aneurysmal subarachnoid hemorrhage: a prospective observational trial using retinal vessel analysis}, series = {Frontiers in Neurology}, volume = {12}, journal = {Frontiers in Neurology}, number = {12}, issn = {1664-2295}, doi = {10.3389/fneur.2021.690183}, pages = {1 -- 15}, year = {2021}, abstract = {Delayed cerebral ischemia (DCI) is a common complication after aneurysmal subarachnoid hemorrhage (aSAH) and can lead to infarction and poor clinical outcome. The underlying mechanisms are still incompletely understood, but animal models indicate that vasoactive metabolites and inflammatory cytokines produced within the subarachnoid space may progressively impair and partially invert neurovascular coupling (NVC) in the brain. Because cerebral and retinal microvasculature are governed by comparable regulatory mechanisms and may be connected by perivascular pathways, retinal vascular changes are increasingly recognized as a potential surrogate for altered NVC in the brain. Here, we used non-invasive retinal vessel analysis (RVA) to assess microvascular function in aSAH patients at different times after the ictus.}, language = {en} } @article{AlbannaKotliarLuekeetal.2018, author = {Albanna, Walid and Kotliar, Konstantin and L{\"u}ke, Jan Niklas and Alpdogan, Serdar and Conzen, Catharina and Lindauer, Ute and Clusmann, Hans and Hescheler, J{\"u}rgen and Vilser, Walthard and Schneider, Toni and Schubert, Gerrit Alexander}, title = {Non-invasive evaluation of neurovascular coupling in the murine retina by dynamic retinal vessel analysis}, series = {Plos one}, volume = {13}, journal = {Plos one}, number = {10}, publisher = {PLOS}, address = {San Francisco}, doi = {10.1371/journal.pone.0204689}, pages = {e0204689}, year = {2018}, abstract = {Background Impairment of neurovascular coupling (NVC) was recently reported in the context of subarachnoid hemorrhage and may correlate with disease severity and outcome. However, previous techniques to evaluate NVC required invasive procedures. Retinal vessels may represent an alternative option for non-invasive assessment of NVC. Methods A prototype of an adapted retinal vessel analyzer was used to assess retinal vessel diameter in mice. Dynamic vessel analysis (DVA) included an application of monochromatic flicker light impulses in predefined frequencies for evaluating NVC. All retinae were harvested after DVA and electroretinograms were performed. Results A total of 104 retinal scans were conducted in 21 male mice (90 scans). Quantitative arterial recordings were feasible only in a minority of animals, showing an emphasized reaction to flicker light impulses (8 mice; 14 scans). A characteristic venous response to flicker light, however, could observed in the majority of animals. Repeated measurements resulted in a significant decrease of baseline venous diameter (7 mice; 7 scans, p < 0.05). Ex-vivo electroretinograms, performed after in-vivo DVA, demonstrated a significant reduction of transretinal signaling in animals with repeated DVA (n = 6, p < 0.001). Conclusions To the best of our knowledge, this is the first non-invasive study assessing murine retinal vessel response to flicker light with characteristic changes in NVC. The imaging system can be used for basic research and enables the investigation of retinal vessel dimension and function in control mice and genetically modified animals.}, language = {en} } @article{AlbannaLuekeSjapicetal.2017, author = {Albanna, Walid and Lueke, Jan Niklas and Sjapic, Volha and Kotliar, Konstantin and Hescheler, J{\"u}rgen and Clusmann, Hans and Sjapic, Sergej and Alpdogan, Serdan and Schneider, Toni and Schubert, Gerrit Alexander and Neumaier, Felix}, title = {Electroretinographic Assessment of Inner Retinal Signaling in the Isolated and Superfused Murine Retina}, series = {Current Eye Research}, journal = {Current Eye Research}, number = {Article in press}, publisher = {Taylor \& Francis}, address = {London}, issn = {1460-2202}, doi = {10.1080/02713683.2017.1339807}, pages = {1 -- 9}, year = {2017}, language = {en} } @article{AlbannaLuekeSchubertetal.2019, author = {Albanna, Walid and L{\"u}ke, Jan Niklas and Schubert, Gerrit Alexander and Dibu{\´e}-Adjei, Maxine and Kotliar, Konstantin and Hescheler, J{\"u}rgen and Clusmann, Hans and Steiger, Hans-Jakob and H{\"a}nggi, Daniel and Kamp, Marcel A. and Schneider, Toni and Neumaier, Felix}, title = {Modulation of Ca v 2.3 channels by unconjugated bilirubin (UCB) - Candidate mechanism for UCB-induced neuromodulation and neurotoxicity}, series = {Molecular and Cellular Neuroscience}, volume = {96}, journal = {Molecular and Cellular Neuroscience}, number = {4}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1044-7431}, doi = {10.1016/j.mcn.2019.03.003}, pages = {35 -- 46}, year = {2019}, language = {en} } @phdthesis{Albracht2010, author = {Albracht, Kirsten}, title = {Influence of mechanical properties of the leg extensor muscletendon units on running economy}, publisher = {Deutsche Sporthochschule K{\"o}ln}, address = {K{\"o}ln}, pages = {X, 1221 Bl. : graph. Darst.}, year = {2010}, language = {en} } @article{AlbrachtArampatzisBaltzopoulos2008, author = {Albracht, Kirsten and Arampatzis, A. and Baltzopoulos, V.}, title = {Assessment of muscle volume and physiological cross-sectional area of the human triceps surae muscle in vivo}, series = {Journal of Biomechanics}, volume = {41}, journal = {Journal of Biomechanics}, issn = {0021-9290}, doi = {10.1016/j.jbiomech.2008.04.020}, pages = {2211 -- 2218}, year = {2008}, language = {en} } @article{AlbrachtArampatzis2013, author = {Albracht, Kirsten and Arampatzis, Adamantios}, title = {Exercise-induced changes in triceps surae tendon stiffness and muscle strength affect running economy in humans}, series = {European Journal of Applied Physiology}, volume = {113}, journal = {European Journal of Applied Physiology}, number = {6}, publisher = {Springer}, address = {Berlin}, issn = {1439-6327}, doi = {10.1007/s00421-012-2585-4}, pages = {1605 -- 1615}, year = {2013}, language = {en} }