@article{Kern2007, author = {Kern, Alexander}, title = {Neue deutsche Blitzschutz-Normung. Reihe DIN EN 62305 / VDE 01 85-305-x:2006}, series = {Der Eisenbahningenieur. 58 (2007), H. 8}, journal = {Der Eisenbahningenieur. 58 (2007), H. 8}, isbn = {0013-2810}, pages = {18 -- 22}, year = {2007}, language = {de} } @article{FoersterDarmoDubeckyetal.1996, author = {F{\"o}rster, Arnold and Darmo, J. and Dubeck{\´y}, F. and Kordos, P.}, title = {Annealing characteristics of native defects in low-temperature-grown MBE GaAs / J. Darmo ; F. Dubecky ; P. Kordos ; A. F{\"o}rster}, series = {Semiconducting and insulating materials 1996 : proceedings of the 9th Conference on Semiconducting and Insulating Materials (SIMC '9), April 29 - May 3, 1996, Toulouse, France / [IEEE]}, journal = {Semiconducting and insulating materials 1996 : proceedings of the 9th Conference on Semiconducting and Insulating Materials (SIMC '9), April 29 - May 3, 1996, Toulouse, France / [IEEE]}, address = {Piscataway, NJ [u.a.]}, isbn = {0-7803-3095-1}, pages = {67 -- ff.}, year = {1996}, language = {en} } @article{Dielmann2002, author = {Dielmann, Klaus-Peter}, title = {Kraft-W{\"a}rme-K{\"a}lte-Kopplung mit Mikrogasturbinen : Abschlussbericht ; [01.09.2000 - 31.01.2002]}, publisher = {Fachhochsch. Aachen, Abt. J{\"u}lich, FB 7, NOWUM-Energy}, address = {J{\"u}lich}, pages = {15 Bl : Ill., graph. Darst.}, year = {2002}, language = {de} } @article{DielmannMehlkopfCudina2004, author = {Dielmann, Klaus-Peter and Mehlkopf, Marcus and Cudina, Boris}, title = {Erfahrungen mit der Software Risa-Gen}, series = {BWK : das Energie-Fachmagazin}, volume = {56}, journal = {BWK : das Energie-Fachmagazin}, number = {3}, isbn = {0006-9612}, issn = {1618-193X}, pages = {24 -- 25}, year = {2004}, language = {de} } @article{Kern2000, author = {Kern, Alexander}, title = {Aktueller Stand zu Risikoabsch{\"a}tzungen bei Blitzeinschl{\"a}gen - Was ist neu in der IEC 61662 Edition 2?}, year = {2000}, language = {de} } @article{KernLanders2002, author = {Kern, Alexander and Landers, E.-U.}, title = {Die neuen Blitzschutz-Vornormen der Reihe VDE-V 0185:2002}, year = {2002}, language = {de} } @article{KernKaiser1995, author = {Kern, Alexander and Kaiser, Ludwig}, title = {Auswirkungen des EMVG auf leittechnische Einrichtungen in großfl{\"a}chigen Industrieanlagen / von Ludwig Kaiser ; Alexander Kern}, series = {ETZ : Elektrotechnik + Automation. 116 (1995), H. 9}, journal = {ETZ : Elektrotechnik + Automation. 116 (1995), H. 9}, isbn = {0170-1711}, pages = {16 -- 18}, year = {1995}, language = {de} } @article{Kern1995, author = {Kern, Alexander}, title = {Blitz-St{\"o}rschutz als Maßnahme der EMV am Beispiel einer ausgedehnten Industrieanlage}, year = {1995}, language = {de} } @article{Kern1996, author = {Kern, Alexander}, title = {Blitz-Schutzzonen mit Schirmungen und Schnittstellen}, series = {Blitzschutz f{\"u}r Geb{\"a}ude und elektrische Anlagen : Vortr{\"a}ge der VDE/ABB-Fachtagung am 29. Februar und 1. M{\"a}rz 1996 in Kassel / Veranst.: Ausschuß Blitzschutz und Blitzforschung (ABB) im VDE-Verband Dt. Elektrotechniker e.V. Wiss. Tagungsleit.: F. Noack. - (Verband Deutscher Elektrotechniker: VDE-Fachbericht ; 49)}, journal = {Blitzschutz f{\"u}r Geb{\"a}ude und elektrische Anlagen : Vortr{\"a}ge der VDE/ABB-Fachtagung am 29. Februar und 1. M{\"a}rz 1996 in Kassel / Veranst.: Ausschuß Blitzschutz und Blitzforschung (ABB) im VDE-Verband Dt. Elektrotechniker e.V. Wiss. Tagungsleit.: F. Noack. - (Verband Deutscher Elektrotechniker: VDE-Fachbericht ; 49)}, publisher = {VDE-Verl.}, address = {Berlin [u.a.]}, isbn = {3-8007-2161-9}, pages = {239 S. : graph. Darst.}, year = {1996}, language = {de} } @article{Kern1998, author = {Kern, Alexander}, title = {Ert{\"u}chtigung des Blitzschutzsystems f{\"u}r ein B{\"u}rogeb{\"a}ude auf der Basis von VDE V 0185 Teil 100 (ENV 61024-1) und VDE 0185 Teil 103 (IEC 1312-1)}, year = {1998}, language = {de} } @article{KernHasseWiesingeretal.1991, author = {Kern, Alexander and Hasse, P. and Wiesinger, J. and Zischank, Wolfgang J.}, title = {Aktuelles aus der Blitzforschung}, series = {ETZ : Elektrotechnik + Automation. 112 (1991), H. 1}, journal = {ETZ : Elektrotechnik + Automation. 112 (1991), H. 1}, isbn = {0170-1711}, year = {1991}, language = {de} } @article{KernHeidlerZahlmannetal.1993, author = {Kern, Alexander and Heidler, Fridolin and Zahlmann, P. and Zischank, Wolfgang J.}, title = {Blitzschutz}, series = {ETZ : Elektrotechnik + Automation. 114 (1993), H. 2}, journal = {ETZ : Elektrotechnik + Automation. 114 (1993), H. 2}, isbn = {0170-1711}, year = {1993}, language = {de} } @article{Kern1993, author = {Kern, Alexander}, title = {Physik der Blitzentladung und Blitzstrom-Parameter bei nat{\"u}rlichen Blitzen}, year = {1993}, language = {de} } @article{Kern1990, author = {Kern, Alexander}, title = {The heating of metal sheets caused by direct lightning strikes-model and measurement}, series = {20th ICPL / International Conference on Lightning Protection, Congress-Center Casino Interlaken, Switzerland, September 24-28, 1990 = Internationale Blitzschutzkonferenz, Congress-Center Casino Interlaken, Schweiz, 24.-28. September 1990}, journal = {20th ICPL / International Conference on Lightning Protection, Congress-Center Casino Interlaken, Switzerland, September 24-28, 1990 = Internationale Blitzschutzkonferenz, Congress-Center Casino Interlaken, Schweiz, 24.-28. September 1990}, publisher = {Schweizerischer Elektrotechnischer Verein}, address = {[Z{\"u}rich]}, pages = {[522] S. (getr. Z{\"a}hl.) : Ill.}, year = {1990}, language = {en} } @article{Kern1989, author = {Kern, Alexander}, title = {Time dependent temperature distribution in metal sheets caused by direct lightning strikes}, series = {Proceedings / Sixth International Symposium on High Voltage Engineering : 28. August - 1. September, 1989, Westin Canal Place Hotel, New Orleans, Louisiana, USA}, journal = {Proceedings / Sixth International Symposium on High Voltage Engineering : 28. August - 1. September, 1989, Westin Canal Place Hotel, New Orleans, Louisiana, USA}, publisher = {Mississippi State University}, address = {Mississippi State, Miss.}, year = {1989}, language = {en} } @article{KernLangWiesingeretal.1989, author = {Kern, Alexander and Lang, U. and Wiesinger, J. and Zischank, Wolfgang J.}, title = {The longitudinal voltage of cable tubes with a screening mesh caused by partial lightning currents}, series = {Proceedings / Sixth International Symposium on High Voltage Engineering : 28. August - 1. September, 1989, Westin Canal Place Hotel, New Orleans, Louisiana, USA}, journal = {Proceedings / Sixth International Symposium on High Voltage Engineering : 28. August - 1. September, 1989, Westin Canal Place Hotel, New Orleans, Louisiana, USA}, publisher = {Mississippi State University}, address = {Mississippi State, Miss.}, year = {1989}, language = {en} } @article{KernZischank1988, author = {Kern, Alexander and Zischank, Wolfgang J.}, title = {Melting effects on metal sheets and air termination wires caused by direct lightning strikes}, series = {Conference proceedings : Graz, {\"O}sterreich, 25. - 29. April 1988 / Gesamtorganisation: {\"O}sterr. Verb. f{\"u}r Elektrotechnik ({\"O}VE), Fachausschuß Blitzschutz ... [Red.: G. Diendorfer ...]}, journal = {Conference proceedings : Graz, {\"O}sterreich, 25. - 29. April 1988 / Gesamtorganisation: {\"O}sterr. Verb. f{\"u}r Elektrotechnik ({\"O}VE), Fachausschuß Blitzschutz ... [Red.: G. Diendorfer ...]}, publisher = {Eigenverl. des {\"O}VE}, address = {Wien}, isbn = {3-85133-001-3}, year = {1988}, language = {en} } @article{KernRothWiedmann1992, author = {Kern, Alexander and Roth, J. and Wiedmann, J.}, title = {Comparison of the damage for various types of fibre reinforced composites due to different lightning test standards (MIL-STD 1757 A, German military VG-standard 96903)}, series = {Proceedings of the 1992 International Aerospace and Ground Conference on Lightning and Static Electricity : October 6-8, 1992, Trump Taj Mahal, Atlantic City, NJ.}, journal = {Proceedings of the 1992 International Aerospace and Ground Conference on Lightning and Static Electricity : October 6-8, 1992, Trump Taj Mahal, Atlantic City, NJ.}, publisher = {U.S. Dept. of Transportation, Federal Aviation Administration}, address = {[Atlantic City, N.J.]}, pages = {Getr. Z{\"a}hl. : Ill. + addendum}, year = {1992}, language = {en} } @article{KernZischank1992, author = {Kern, Alexander and Zischank, Wolfgang J.}, title = {The effect of parallel wires on the longitudinal voltage drop along shielded cables}, series = {Conference proceedings : 21st International Conference on Lightning Protection, Berlin Congress Center (BCC) Germany, September 22 - 25, 1992 = 21. Internationale Blitzschutzkonferenz / [proceedings ed. staff: J. Pilling ...]}, journal = {Conference proceedings : 21st International Conference on Lightning Protection, Berlin Congress Center (BCC) Germany, September 22 - 25, 1992 = 21. Internationale Blitzschutzkonferenz / [proceedings ed. staff: J. Pilling ...]}, publisher = {VDE-Verl.}, address = {Berlin [u.a.]}, isbn = {3-8007-1885-5}, pages = {570 S : Ill., graph. Darst., Kt.}, year = {1992}, language = {en} } @article{KernWiesingerZischank1991, author = {Kern, Alexander and Wiesinger, J. and Zischank, Wolfgang J.}, title = {Calculation of the longitudinal voltage along metal tubes caused by lightning currents and protection measures}, series = {Seventh International Symposium on High Voltage Engineering : Dresden, August 26 - 30 1991}, journal = {Seventh International Symposium on High Voltage Engineering : Dresden, August 26 - 30 1991}, publisher = {Techn. Univ.}, address = {Dresden}, year = {1991}, language = {en} } @article{Kern1991, author = {Kern, Alexander}, title = {Simulation and measurement of melting effects on metal sheets caused by direct lightning strikes}, series = {1991 International Aerospace and Ground Conference on Lightning and Static Electricity : proceedings of a conference ... held at Cocoa Beach, Florida, April 16-19, 1991 / NASA}, journal = {1991 International Aerospace and Ground Conference on Lightning and Static Electricity : proceedings of a conference ... held at Cocoa Beach, Florida, April 16-19, 1991 / NASA}, address = {Washington, DC}, year = {1991}, language = {en} } @article{KernZischankHeidleretal.1998, author = {Kern, Alexander and Zischank, Wolfgang J. and Heidler, Fridolin and Wiesinger, J. [u.a.]}, title = {Shielding effectiveness of reinforced concrete cable ducts carrying partial lightning currents}, series = {Conference proceedings : 14th - 18th September 1998, [Burlington Hotel, Birmingham, United Kingdom] / organised by: School of Engineering and Advanced Technology, Staffordshire University, United Kingdom}, journal = {Conference proceedings : 14th - 18th September 1998, [Burlington Hotel, Birmingham, United Kingdom] / organised by: School of Engineering and Advanced Technology, Staffordshire University, United Kingdom}, address = {Birmingham}, year = {1998}, language = {en} } @article{KernThomsen1994, author = {Kern, Alexander and Thomsen, M.}, title = {Comparison of single point and equipotential bonding for I\&C systems of large-area industrial sites}, series = {Volume of proceedings : Budapest, Hungary, September 19-23, 1994 / organized by: Technical University of Budapest}, journal = {Volume of proceedings : Budapest, Hungary, September 19-23, 1994 / organized by: Technical University of Budapest}, publisher = {Techn. Univ.}, address = {Budapest}, pages = {Getr. Z{\"a}hlung [ca. 610 S.]}, year = {1994}, language = {en} } @article{KernDrumm1994, author = {Kern, Alexander and Drumm, F.}, title = {Survey of the lightning threat for aircraft based on natural lightning data and fixed in the German Standard DIN VG 95371 / Part 10}, series = {Proceedings of the 1994 International Aerospace and Ground Conference on Lightning and Static Electricity : May 14 - 27, 1994, Bundesakademie f{\"u}r Wehrverwaltung und Wehrtechnik Mannheim ; final report / [conference chairman Jan Luiken TerHaseborg]}, journal = {Proceedings of the 1994 International Aerospace and Ground Conference on Lightning and Static Electricity : May 14 - 27, 1994, Bundesakademie f{\"u}r Wehrverwaltung und Wehrtechnik Mannheim ; final report / [conference chairman Jan Luiken TerHaseborg]}, publisher = {Bundesakad. f{\"u}r Wehrverwaltung und Wehrtechnik}, address = {Mannheim}, pages = {IX, 492 S : Ill., graph. Darst}, year = {1994}, language = {en} } @article{KernZischank1993, author = {Kern, Alexander and Zischank, Wolfgang J.}, title = {L{\"a}ngsspannung an blitzstromdurchflossenen Schirmkabeln - Einfluß paralleler Entlastungsleitungen}, series = {Elektrie : wissenschaftlich-technische Zeitschrift der Elektrotechnik. 47 (1993), H. 6}, journal = {Elektrie : wissenschaftlich-technische Zeitschrift der Elektrotechnik. 47 (1993), H. 6}, isbn = {0013-5399}, year = {1993}, language = {de} } @article{KernKrichel2004, author = {Kern, Alexander and Krichel, Frank}, title = {Considerations about the lightning protection system of mains independent renewable energy hybrid-systems - practical experiences}, series = {Journal of electrostatics. 60 (2004), H. 2-4}, journal = {Journal of electrostatics. 60 (2004), H. 2-4}, isbn = {0304-3886}, pages = {257 -- 263}, year = {2004}, language = {en} } @article{ZischankHeidlerWiesingeretal.2004, author = {Zischank, Wolfgang J. and Heidler, Fridolin and Wiesinger, J. and Metwally, I. and Kern, Alexander and Seevers, M.}, title = {Laboratory simulation of direct lightning strokes to a modeled building : measurement of magnetic fields and included voltages}, series = {Journal of electrostatics. 60 (2004), H. 2 - 4}, journal = {Journal of electrostatics. 60 (2004), H. 2 - 4}, isbn = {0304-3886}, pages = {223 -- 232}, year = {2004}, language = {en} } @article{KernHeidlerZischanketal.2002, author = {Kern, Alexander and Heidler, Fridolin and Zischank, Wolfgang J. and Frentzel, Ralf}, title = {Lightning current distribution and coupling to control cables in power plants or large industrial facilites}, year = {2002}, language = {en} } @article{KernKrichelNeskakisetal.2001, author = {Kern, Alexander and Krichel, Frank and Neskakis, Apostolos and M{\"u}ller, Klaus-Peter (u.a.)}, title = {Lightning protection design of a renewable energy hybrid-system without power mains connection}, year = {2001}, language = {en} } @book{Kern2004, author = {Kern, Alexander}, title = {Blitz- und {\"U}berspannungsschutz f{\"u}r Anlagen der regenerativen Energietechnik}, publisher = {Fachhochschule Aachen, Abt. J{\"u}lich}, address = {Aachen}, year = {2004}, language = {de} } @article{Kern1998, author = {Kern, Alexander}, title = {Beispiele f{\"u}r EMV-Maßnahmen in großfl{\"a}chigen Anlagen}, series = {EMV von Geb{\"a}uden, Anlagen und Ger{\"a}ten : praktische Umsetzung der technischen, wirtschaftlichen und gesetzlichen Anforderungen f{\"u}r die CE-Kennzeichnung / Anton Kohling (Hrsg.). Gerd Balzer...}, journal = {EMV von Geb{\"a}uden, Anlagen und Ger{\"a}ten : praktische Umsetzung der technischen, wirtschaftlichen und gesetzlichen Anforderungen f{\"u}r die CE-Kennzeichnung / Anton Kohling (Hrsg.). Gerd Balzer...}, publisher = {VDE-Verl.}, address = {Berlin [u.a.]}, isbn = {3-8007-2261-5}, pages = {408 S. : Ill., zahlr. graph. Darst.}, year = {1998}, language = {de} } @book{Kern1990, author = {Kern, Alexander}, title = {Theoretische und experimentelle Untersuchung der Erw{\"a}rmung von Metallblechen bei Blitzeinschlag}, publisher = {Univ. der Bundeswehr}, address = {M{\"u}nchen}, pages = {219 S. : Ill., graph. Darst.}, year = {1990}, language = {de} } @inproceedings{BehrensFrentzelKern2009, author = {Behrens, J{\"o}rg and Frentzel, Ralf and Kern, Alexander}, title = {Simulation der transienten Spannungsverl{\"a}ufe im Eigenbedarfsnetz eines Großkraftwerks bei einem kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung}, isbn = {978-3-8007-3197-8}, year = {2009}, abstract = {8. VDE/ABB-Blitzschutztagung, 29. - 30. Oktober 2009 in Neu-Ulm. Blitzschutztagung <8, 2009, Neu-Ulm> Berlin : VDE Verl. 2009 Großkraftwerke k{\"o}nnen durch Blitzentladungen mit potentiellen Auswirkungen auf deren Verf{\"u}gbarkeit und Sicherheit gef{\"a}hrdet werden. Ein sehr spezielles Szenario, welches aus aktuellem Anlass zu untersuchen war, betrifft den kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung am Netzanschluss der Anlage. Wird nun noch ein sogenannter Schirmfehler unterstellt, d.h. der direkte Blitzeinschlag erfolgt in ein Leiterseil des Hoch- bzw. H{\"o}chstspannungsnetzes und nicht in das dar{\"u}ber gespannte Erdseil, so bedeutet dies eine extreme elektromagnetische Einwirkung. Der vorliegende Beitrag befasst sich mit der Simulation eines solchen Blitzeinschlages und dessen Auswirkungen auf den Netzanschluss und die Komponenten der elektrischen Eigenbedarfsanlagen eines Kraftwerks auf den unterlagerten Spannungsebenen. Die dabei gewonnenen Erkenntnisse lassen sich ohne Einschr{\"a}nkungen auf Industrieanlagen mit Mittelspannungs-Netzanschluss und ohne eigener Stromversorgung {\"u}bertragen.}, subject = {Blitzschutz}, language = {de} } @inproceedings{KernBeierlZischank2009, author = {Kern, Alexander and Beierl, Ottmar and Zischank, Wolfgang}, title = {Calculation of the separation distance according to IEC 62305-3: 2006-10 - Remarks for the application and simplified methods}, year = {2009}, abstract = {[Paper of the X International Symposium on Lightning Protection 9th - 13th November, 2009 - Curitiba, Brazil. 6 pages] The international standard IEC 62305-3, published in 2006, requires as an integral part of the lightning protection system (LPS) the consideration of a separation distance between the conductors of the LPS and metal and electrical installations inside the structure to be protected. IEC 62305-3 gives two different methods for this calculation: a standard, simplified approach and a more detailed approach, which differ especially regarding the treatment of the current sharing effect on the LPS conductors. Hence, different results for the separation distance are possible, leading to some discrepancies in the use of the standard. The standard approach defined in the main part (Clause 6.3) and in Annex C of the standard in some cases may lead to a severe oversizing of the required separation distance. The detailed approach described in Annex E naturally gives more correct results. However, a calculation of the current sharing amongst all parts of the air-termination and downconductor network is necessary, in many cases requiring the use of network analysis programs. In this paper simplified methods for the assessment of the current sharing are presented, which are easy to use as well as sufficiently adequate.}, subject = {Blitzschutz}, language = {de} } @article{WettingfeldKernKraemeretal.2009, author = {Wettingfeld, J{\"u}rgen and Kern, Alexander and Kr{\"a}mer, Heinz-Josef and Thorm{\"a}hlen, Reyno}, title = {International anerkannte Blitzschutznormen : Ausgewogener und sicherer Schutz}, publisher = {Fachhochschule Aachen}, address = {Aachen}, year = {2009}, abstract = {Die Einleitung zur Norm DIN EN 62305-3 beschreibt klar und ein - deutig: Der vorliegende Teil der IEC 62305 behandelt den Schutz von baulichen Anlagen gegen materielle Sch{\"a}den und den Schutz von Personen gegen Verletzungen durch Ber{\"u}hrungs- und Schrittspannungen. Als das wesentlichste und effektivste Mittel zum Schutz von baulichen Anlagen gegen materielle Sch{\"a}den gilt das Blitz - schutzsystem (LPS).}, subject = {Blitzschutz}, language = {de} } @misc{Kaster2009, author = {Kaster, Jan Mathis}, title = {Untersuchungen zur Specklereduktion bei der Infrarot-Laser gest{\"u}tzten Ferndetektion von TNT-Oberfl{\"a}chenkontaminationen}, year = {2009}, abstract = {Das Ziel der vorliegenden Arbeit ist die Specklereduktion bei der Infrarotlaser-gest{\"u}tzten abbildenden Ferndetektion von TNT-Oberfl{\"a}chenkontaminationen. F{\"u}r die Detektion wird die Probenoberfl{\"a}che mit einem abstimmbaren Quantenkaskadenlaser bei verschiedenen Wellenzahlen im Spektralbereich von 1340cm-1 bis 1380cm-1 bestrahlt, w{\"a}hrend eine Infrarot-Kamera Bilder der bestrahlten Fl{\"a}che aufzeichnet. Diese Bilder werden dann so verarbeitet, dass im Ausgabebild die chemisch spezifische TNT-Absorption durch eine {\"A}nderung der Helligkeit {\"o}rtlich aufgel{\"o}st erkennbar werden. Da koh{\"a}rente Strahlung, welche beispielsweise an optisch rauen Oberfl{\"a}chen reflektiert wird, aufgrund der stochastischen Verteilung der Oberfl{\"a}chenrautiefe mit der einfallenden Strahlung lateral unterschiedlich interferiert, entsteht ein „Rauschen" in der aufgezeichneten Strahlungsleistungsverteilung, das sog. Speckle-Ph{\"a}nomen. Die Empfindlichkeit der oben skizzierten Lasergest{\"u}tzten Messtechnik wird im Wesentlichen durch diesen Effekt limitiert. Um die durch Laserspeckles verursachten Rauschanteile zu reduzieren, gibt es verschiedene M{\"o}glichkeiten. Durch Reduktion von zeitlicher und r{\"a}umlicher Koh{\"a}renz der Strahlung wird deren Interferenzf{\"a}higkeit reduziert und durch Variieren des Specklemusters w{\"a}hrend einer Bildaufzeichnung f{\"u}hren Mittelungen unkorrelierter Rauschanteile zu einer Specklekontrastreduktion. Letztere M{\"o}glichkeit resultiert daraus, dass Laserspeckles statistisch durch die Familie der Gammaverteilungen beschrieben werden k{\"o}nnen. Demnach verbessert sich das Signal-zu-Rausch-Verh{\"a}ltnis mit der Anzahl gemittelter, unkorrelierter Rauschmuster proportional zur Wurzel dieser Anzahl. Ein im MIR-Spektralbereich umsetzbarer Ansatz, der all diese M{\"o}glichkeiten ber{\"u}cksichtigt, wurde bereits 1971 von Lowenthal und Joyeaux vorgeschlagen und im Rahmen der vorliegenden Arbeit f{\"u}r den infraroten Spektralbereich adaptiert. Dazu wird die Strahlung mit zwei CVD-Diamant-Wafern moduliert; ein Wafer ist dabei station{\"a}r und der andere rotiert mit ca. 70Hz. In der vorliegenden Arbeit konnte mit diesem Ansatz eine Verbesserung des Signal-zu-Rausch-Verh{\"a}ltnisses in der betrachteten Strahlungsleistungs¬verteilung von urspr{\"u}nglich 3 auf etwa 45 erzielt werden. So konnten erstmals TNT-Kontaminationen von bis zu 10µg/cm² in einem Abstand von 5m abbildend nachgewiesen werden. Dies entspricht der Kontamination durch einen mit TNT leicht verunreinigten Fingerabdruck.}, subject = {Speckle}, language = {de} } @inproceedings{KernDikta2009, author = {Kern, Alexander and Dikta, Gerhard}, title = {Probability of damage of electrical and electronic systems due to indirect lightning flashes - investigation of data from German insurance companies}, year = {2009}, abstract = {In the presented paper data collected from the field related to damage statistics of electrical and electronic apparatus in household are reported and investigated. These damages (total number approx. 74000 cases), registered by five German insurance companies in 2005 and 2006, were adviced by customers as caused by lightning overvoltages. With the use of stochastical methods it is possible, to reasses the collected data and to distinguish between cases, which are with high probability caused by lightning overvoltages, and those, which are not. If there was an indication for a direct strike, this case was excluded, so the focus was only on indirect lightning flashes, i.e. only flashes to ground near the structure and flashes to or nearby an incoming service line were investigated. The data from the field contain the location of damaged apparatus (residence of the policy holder) and the distances of the nearest cloud-to-ground stroke to the location of the damage registered by the German lightning location network BLIDS at the date of damage. The statistical data along with some complementary numerical simulations allow to verify the correspondence of the Standards rules used for IEC 62305-2 with the field data and to define some correction needs. The results could lead to a better understanding whether a damage reported to an insurance company is really caused by indirect lightning, or not.}, subject = {Blitzschutz}, language = {en} } @inproceedings{BruessermannDeuster2005, author = {Br{\"u}ssermann, Klaus and Deuster, M.}, title = {Temperature measurement to optimise the burning process}, year = {2005}, abstract = {One of the most important parameters in a burning chamber - in power stations, in waste to energy plants - is the temperature. This temperature is in the range of 700-1500 °C - one of the most advanced measuring methods being the acoustic pyrometry with the possibility of producing temperature mapping in one level of the burning chamber - comparable to computer tomography. The results of these measurements discussed in the presentation can be used - to fulfil the legal requirements in the FRG or in the EU - to equalise the temperature in one level of the burning chamber to optimise the steam production (better efficiency of the plant) and to minimise the production of temperature controlled flue gas components (NO, CO a. o.) - to control the SNCR-process if used.}, subject = {Pyrometrie}, language = {en} } @inproceedings{Bruessermann2005, author = {Br{\"u}ssermann, Klaus}, title = {Platform of Excellence in "Energy and Environment"}, year = {2005}, abstract = {The Ministry of Science and Research in North Rhine-Westphalia created eight platforms of excellence, one in the research area „Energy and Environment" in 2002 at ACUAS. This platform concentrates the research and development of 13 professors in J{\"u}lich and Aachen and of two scientific institutes with different topics: - NOWUM-Energy with emphasis on efficient and economic energy conversion - The Solar Institute J{\"u}lich - SIJ - being the largest research institute in the field of renewables at a University of Applied Sciences in Germany With this platform each possible energy conversion - nuclear, fossil, renewable- can be dealt with to help solving the two most important problems of mankind, energy and potable water. At the CSE are presented the historical development, some research results and the combined master studies in „Energy Systems" and „Nuclear Applications"}, subject = {Energietechnik}, language = {en} } @inproceedings{DielmannSchieke2000, author = {Dielmann, Klaus-Peter and Schieke, Wolf}, title = {Mikrogasturbinen - Aufbau und Anwendungen}, year = {2000}, abstract = {Mikrogasturbinen: Funktion, Aufbau, Hersteller, Bauformen, Rekuperatorparameter, Besonderheit der Konstruktion, Regelung, Regelbarkeit, Vergleich mit anderen Systemen, Wirkungs- und Nutzungsgrade, Schadstoffemissionen, Nutzung in Kraft-W{\"a}rme-Kopplung, Kraft-W{\"a}rme-K{\"a}lte-Kopplung}, subject = {Gasturbine}, language = {de} } @inproceedings{Dielmann2001, author = {Dielmann, Klaus-Peter}, title = {Umsetzung Strom-/Gasmarkt nach der Liberalisierung}, year = {2001}, abstract = {Neues Energierecht Strom Neues Energierecht Gas Emissionshandel in Europa - ein interessanter Markt?}, subject = {Energierecht}, language = {de} } @inproceedings{Dielmann2002, author = {Dielmann, Klaus-Peter}, title = {Darstellung des Erneuerbaren Energiegesetzes (EEG) und dessen Auswirkungen}, year = {2002}, abstract = {Erneuerbares Energien-Gesetz: Anwendungsbereich, Abnahme- und Verg{\"u}tungspflicht, Verg{\"u}tungss{\"a}tze, Netzkosten, Ausgleichsregelungen Auswirkungen des EEG: Photovoltaik, Windkraft, Biomasse, Wasserkraft, Kl{\"a}r-, Deponie- und Grubengas, Geothermie Zusammenfassung und Ausblick}, subject = {Energierecht}, language = {de} } @inproceedings{DielmannPeters2002, author = {Dielmann, Klaus-Peter and Peters, Bernhard}, title = {Micro Turbine Using Different Gases and Liquid Fuels}, year = {2002}, abstract = {Micro turbine using different gases and liquid fuels}, subject = {Gasturbine}, language = {en} } @inproceedings{DielmannVelden2003, author = {Dielmann, Klaus-Peter and Velden, Alwin van der}, title = {Virtuelle Kraftwerke - Stand der Technik}, year = {2003}, abstract = {Ausgangslage, Funktionsprinzip des virtuellen Kraftwerkes, Energiemanagementsysteme (EMS), Einsatzgebiete, Anlagesysteme eines VKW's, Einsatzbereich der verschiedenen dezentralen Energieanlagen, Vorteile des virtuellen Kraftwerkes, Auswirkungen auf das elektrische Netz, Wirtschaftliche Aspekte, Beispielprojekte}, language = {de} } @inproceedings{DielmannCudina2003, author = {Dielmann, Klaus-Peter and Cudina, Boris}, title = {Emissionsrechtehandel in Europa - ein neues Instrument f{\"u}r den Umweltschutz}, year = {2003}, abstract = {Funktionsprinzip Emissionsrechtehandel, Betroffene Anlagen und Branchen, Erstverteilung der Emissionsrechte, Bereits erbrachte Emissionsreduktionen (early actions), Ausstieg von betroffenen Unternehmen (opt-out), Teilnahme von nicht betroffenen Unternehmen, Einsatz von Biobrennstoffen, Erfassung und Dokumentation der Emissionen}, subject = {Umweltzertifikathandel}, language = {de} } @inproceedings{Kern2002, author = {Kern, Alexander}, title = {Risikomanagement : Absch{\"a}tzung des Schadensrisikos f{\"u}r bauliche Anlagen - Die neue Vornorm DIN V VDE V 0185 Teil 2 : 2002}, year = {2002}, abstract = {Alle Unternehmen sind vielf{\"a}ltigen Risiken ausgesetzt, die Finanz- und Betriebsbereiche einschließlich Dienstleistungen betreffen k{\"o}nnen. Die Firmen m{\"u}ssen {\"u}blicherweise Risiken eingehen, um im Wettbewerb bestehen zu k{\"o}nnen. Entscheidend ist, dass man sich {\"u}ber die Risiken bewusst ist, diese einsch{\"a}tzen und kontrollieren kann. Falsche Einsch{\"a}tzungen, Vers{\"a}umnisse und Fehlentscheidungen k{\"o}nnen empfindliche finanzielle Sch{\"a}den bis hin zum Totalverlust nach sich ziehen. Ein effektives Risikomanagement ist heute als wichtiger Sicherheitsfaktor anzusehen und sollte zur strategischen Unternehmensf{\"u}hrung geh{\"o}ren. Ein vorausschauendes Risikomanagement beinhaltet, Risiken f{\"u}r das Unternehmen zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent, welche Risiken sinnvollerweise {\"u}ber Versicherungen abgedeckt werden sollten. Beim Versicherungsmanagement ist jedoch zu bedenken, dass zur Erreichung bestimmter Ziele Versicherungen nicht geeignet sind (z.B. Erhaltung der Lieferf{\"a}higkeit). Eintrittswahrscheinlichkeiten bestimmter Risiken lassen sich durch Versicherungen nicht ver{\"a}ndern. Bei Unternehmen, die mit umfangreichen elektronischen Einrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Ber{\"u}cksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nicht-Verf{\"u}gbarkeit der elektronischen Einrichtungen und damit der Produktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardware-Schaden an der betroffenen Anlage oft bei weitem {\"u}bersteigt. Im Blitzschutz gewinnt innovatives Denken in Schadensrisiken langsam an Bedeutung. Risikoanalysen haben die Objektivierung und Quantifizierung der Gef{\"a}hrdung von baulichen Anlagen und ihrer Inhalte durch direkte und indirekte Blitzeinschl{\"a}ge zum Ziel. Seinen Niederschlag hat dieses neue Denken in der neuen deutschen Norm DIN V 0185-2 VDE V 0185 Teil 2 gefunden. Die hier vorgegebene Risikoanalyse gew{\"a}hrleistet, dass ein f{\"u}r alle Beteiligten nachvollziehbares Blitzschutz-Konzept erstellt werden kann, das technisch und wirtschaftlich optimiert ist, d.h. bei m{\"o}glichst geringem Aufwand den notwendigen Schutz gew{\"a}hrleisten kann. Die sich aus der Risikoanalyse ergebenden Schutzmaßnahmen sind dann in den weiteren Normenteilen der neuen Reihe VDE V 0185 detailliert beschrieben.}, language = {de} } @article{Kern2003, author = {Kern, Alexander}, title = {Risikomanagement f{\"u}r den Blitzschutz - Absch{\"a}tzung des Blitzschadensrisikos nach der neuen Vornorm VDE V 0185 Teil 2 : 2002}, year = {2003}, abstract = {Ein vorausschauendes Risikomanagement beinhaltet, Risiken zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent,welche Risiken sinnvoll {\"u}ber Versicherungen abgedeckt werden sollten. Bei Unternehmen, die mit umfangreichen elektronischenEinrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Ber{\"u}cksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nichtverf{\"u}gbarkeit der elektronischen Einrichtungen und damit derProduktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardwareschaden an der betroffenen Anlage oft bei weitem {\"u}bersteigt.}, language = {de} } @inproceedings{Kern2003, author = {Kern, Alexander}, title = {Absch{\"a}tzung des Blitzschadensrisikos f{\"u}r bauliche Anlagen - Die neue Bestimmung DIN V VDE V 0185 Teil 2 : 2002 - Allgemeines, Absch{\"a}tzungsverfahren, Berechnungsbeispiele}, year = {2003}, abstract = {Ein vorausschauendes Risikomanagement beinhaltet, Risiken f{\"u}r das Unternehmen zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent, welche Risiken sinnvollerweise {\"u}ber Versicherungen abgedeckt werden sollten. Beim Versicherungsmanagement ist jedoch zu bedenken, dass zur Erreichung bestimmter Ziele Versicherungen nicht immer geeignet sind (z.B. Erhaltung der Lieferf{\"a}higkeit). Eintrittswahrscheinlichkeiten bestimmter Risiken lassen sich durch Versicherungen nicht ver{\"a}ndern. Bei Unternehmen, die mit umfangreichen elektronischen Einrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Ber{\"u}cksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nicht-Verf{\"u}gbarkeit der elektronischen Einrichtungen und damit der Produktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardware-Schaden an der betroffenen Anlage oft bei weitem {\"u}bersteigt. Im Blitzschutz gewinnt innovatives Denken in Schadensrisiken langsam an Bedeutung. Risikoanalysen haben die Objektivierung und Quantifizierung der Gef{\"a}hrdung von baulichen Anlagen und ihrer Inhalte durch direkte und indirekte Blitzeinschl{\"a}ge zum Ziel. Seinen Niederschlag hat dieses neue Denken in der neuen deutschen Vornorm DIN V 0185-2 VDE V 0185 Teil 2 [1] gefunden. Die hier vorgegebene Risikoanalyse gew{\"a}hrleistet, dass ein f{\"u}r alle Beteiligten nachvollziehbares Blitzschutz-Konzept erstellt werden kann, das technisch und wirtschaftlich optimiert ist, d.h. bei m{\"o}glichst geringem Aufwand den notwendigen Schutz gew{\"a}hrleisten kann. Die sich aus der Risikoanalyse ergebenden Schutzmaßnahmen sind dann in den weiteren Normenteilen der neuen Reihe VDE V 0185 [2, 3] detailliert beschrieben.}, language = {de} } @inproceedings{ZischankKernFrentzeletal.2000, author = {Zischank, Wolfgang J. and Kern, Alexander and Frentzel, Ralf and Heidler, Fridolin and Seevers, M.}, title = {Assessment of the lightning transient coupling to control cables interconnecting structures in large industrial facilities and power plants}, year = {2000}, abstract = {Large industrial facilities and power plants often require a huge number fo information and control cables between the differnet structures. These I\&C-cables can be routed in reinforced concrete cable ducts or in isolated buried cable runs. KTA 2206 is the German lightning protection standard for nuclear power plants. During the last several years considerable effort has been made to revise this standard. Despite the well established principles and design guidelines for the construction of the lightning protection system, this standard puts special emphasis on the coupling of transient overvoltages to I\&C-cables.}, language = {en} } @inproceedings{KernKrichelMueller2001, author = {Kern, Alexander and Krichel, Frank and M{\"u}ller, Klaus-Peter}, title = {Lightning protection design of a renewable energy hybrid-system without power mains connection}, year = {2001}, abstract = {In the year 2000 a direct lightning strike to the hybridsystem without power mains connection VATALI on the Greek island Crete results in the destruction and damage of some mechanical and electrical components. The hybrid-system VATALI was not lightning protected at that time. The hardware damage costs are approx. 60,000 €. The exposed site of the hybrid-system on top of a mountain was and still is the reason for a high risk of lightning strikes. Also in the future further lightning strikes have to be taken into consideration. In the paper a fundamental lightning protection design concept for renewable energy hybrid-systems without power mains connection and protection measures against direct strikes and overvoltages are shown in detail. The design concept was realized exemplarily for the hybrid-system VATALI. The hardware costs for the protection measures were about 15,000 €. About 50\% of the costs are due to protection measures against direct strikes, 50\% are due to overvoltage protection. Future extensions, new installations, or modifications have to be included into the lightning protection design concept of the hybrid-system.}, language = {en} }