@article{PrumeRoelofsSchmitzetal.2002, author = {Prume, Klaus and Roelofs, Andreas and Schmitz, Thorsten and Reichenberg, Bernd}, title = {Compensation of the Parasitic Capacitance of a Scanning Force Microscope Cantilever Used for Measurements on Ferroelectric Capacitors of Submicron Size by Means of Finite Element Simulations / Prume, Klaus ; Roelofs, Andreas ; Schmitz, Thorsten ; Reichenb}, series = {Japanese Journal of Applied Physics. 41 (2002), H. 11B}, journal = {Japanese Journal of Applied Physics. 41 (2002), H. 11B}, isbn = {0021-4922}, pages = {7198 -- 7201}, year = {2002}, language = {en} } @article{PrumeMeyerWaseretal.2005, author = {Prume, Klaus and Meyer, Ren{\´e} and Waser, Rainer and Schmitz, Torsten}, title = {Dynamic leakage current compensation in ferroelectric thin-film capacitor structures / Meyer, Ren{\´e} ; Waser, Rainer ; Prume, Klaus ; Schmitz, Torsten ; Tiedke, Stephan}, series = {Applied Physics Letters . 86 (2005), H. 14}, journal = {Applied Physics Letters . 86 (2005), H. 14}, isbn = {0003-6951}, pages = {142907-1 -- 142907-3}, year = {2005}, language = {en} } @article{PrumeFrankenMaieretal.2000, author = {Prume, Klaus and Franken, Klaus and Maier, Horst R. and Waser, Rainer}, title = {Finite-Element Analysis of Ceramic Multilayer Capacitors: Failure Probability Caused by Wave Soldering and Bending Loads / Franken, Klaus ; Maier, Horst R. ; Prume, Klaus ; Waser, Rainer}, series = {Journal of the American Ceramic Society. 83 (2000), H. 6}, journal = {Journal of the American Ceramic Society. 83 (2000), H. 6}, isbn = {0002-7820}, pages = {1433 -- 1440}, year = {2000}, language = {en} } @article{PrumeWaserFrankenetal.2000, author = {Prume, Klaus and Waser, Rainer and Franken, Klaus and Maier, Horst R.}, title = {Finite-Element Analysis of Ceramic Multilayer Capacitors: Modeling and Electrical Impedance Spectroscopy for a Nondestructive Failure Test / Prume, Klaus ; Waser, Rainer ; Franken, Klaus ; Maier, Horst R. ;}, series = {Journal of the American Ceramic Society. 83 (2000), H. 5}, journal = {Journal of the American Ceramic Society. 83 (2000), H. 5}, isbn = {0002-7820}, pages = {1153 -- 1159}, year = {2000}, language = {en} } @article{PrumeReichenbergRoelofsetal.2004, author = {Prume, Klaus and Reichenberg, B. and Roelofs, A. and Waser, R.}, title = {In-situ compensation of the parasitic capacitance for nanoscale hysteresis measurements / Schmitz, T. ; Prume, K. ; Reichenberg, B. ; Roelofs, A. ; Waser, R. ; Tiedke, S.}, series = {Journal of the European Ceramic Society. 24 (2004), H. 6}, journal = {Journal of the European Ceramic Society. 24 (2004), H. 6}, isbn = {0955-2219}, pages = {1145 -- 1147}, year = {2004}, language = {en} } @article{EnningBaier2009, author = {Enning, Manfred and Baier, M.}, title = {Energetic and operational use of FlexCargoRail freight wagons in the single wagon load traffic / Baier, M. ; Enning, M.}, series = {Towards zero emission : EVS 24, the 24th International Battery, Hybrid and Fuel Cell Electric Vehicle Symposium \& Exhibition, Stavanger, Norway, May 13 - 16, 2009 ; symposium proceedings / organised by AVERE ... Robert St{\"u}ssi [Hrsg.]}, journal = {Towards zero emission : EVS 24, the 24th International Battery, Hybrid and Fuel Cell Electric Vehicle Symposium \& Exhibition, Stavanger, Norway, May 13 - 16, 2009 ; symposium proceedings / organised by AVERE ... Robert St{\"u}ssi [Hrsg.]}, address = {Stavanger}, pages = {CD-Rom}, year = {2009}, language = {en} } @article{EnningBernhardRake1994, author = {Enning, Manfred and Bernhard, S. and Rake, H.}, title = {Automation of a laboratory plant for direct casting of thin steel strips / Bernhard, S. ; Enning, M. ; Rake, H.}, series = {Control Engineering Practice. 2 (1994), H. 6}, journal = {Control Engineering Practice. 2 (1994), H. 6}, isbn = {0967-0661}, pages = {961 -- 967}, year = {1994}, language = {en} } @article{StaatSponagelNguyen2010, author = {Staat, Manfred and Sponagel, Stefan and Nguyen, Nhu Huynh}, title = {Experiment and material model for soft tissue materials}, series = {Constitutive models for rubber VI}, journal = {Constitutive models for rubber VI}, publisher = {Taylor \& Francis}, address = {London}, isbn = {9780429206597 (eBook)}, doi = {10.1201/NOE0415563277-90}, pages = {6 Seiten}, year = {2010}, abstract = {Biomechanics studies biological soft tissue materials (growth, remodeling) in vivo. For this objective, the detailed information of material properties must be well defined to construct reliable constitutive models. In the paper, the bulge test is carried out with elastomers in order to develop a test method. Then, application of the test for soft tissue materials is straightforward due to the similarities between elastomers with soft tissue materials as proved in Holzapfel 2005, Ogden 2009. It means, after the preliminary experiments and parameter identification with rubber materials has been setup, experiments on soft tissue materials can be similarly carried out. Elastomers have a complex behavior which strongly depends on the largest previous load cycle. For simplicity we consider only the first loading.}, language = {en} } @article{PrumeWaser2000, author = {Prume, Klaus and Waser, Rainer}, title = {Finite-element simulation of coupled characteristics of ceramic multilayer capacitors under transient electrical loading / Prume, Klaus ; Waser, Rainer}, series = {Proceedings of the 2000 12th IEEE International Symposium on Applications of Ferroelectrics. Vol. 2}, journal = {Proceedings of the 2000 12th IEEE International Symposium on Applications of Ferroelectrics. Vol. 2}, pages = {675 -- 678}, year = {2000}, language = {en} } @article{Prume2007, author = {Prume, Klaus}, title = {Electrical and electromechanical characterization of piezoelectric thin films in view of MEMS application / Tiedke, S. ; Prume, K. ; Schmitz-Kempen, T.;}, pages = {702}, year = {2007}, language = {en} } @article{PrumeMuraltCalameetal.2007, author = {Prume, Klaus and Muralt, P. and Calame, F. and Schmitz-Kempen, T.}, title = {Piezoelectric thin films: evaluation of electrical and electromechanical characteristics for MEMS devices / Prume, K. ; Muralt, P. ; Calame, F. ; Schmitz-Kempen, T. ; Tiedke, S. ;}, series = {IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. 54 (2007), H. 1}, journal = {IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. 54 (2007), H. 1}, isbn = {0885-3010}, pages = {81 -- 14}, year = {2007}, language = {en} } @article{PrumeTiedkeSchmitzetal.2001, author = {Prume, Klaus and Tiedke, S. and Schmitz, T. and Roelofs, A.}, title = {Direct hysteresis measurements of single nanosized ferroelectric capacitors contacted with an atomic force microscope / Tiedke, S. ; Schmitz, T. ; Prume, K. ; Roelofs, A. ; Schneller, T. ; Kall, U. ; Waser, R. ; Ganpule, C. S. ; Nagarajan, V. ; Stanishevs}, series = {Applied Physics Letters. 79 (2001), H. 22}, journal = {Applied Physics Letters. 79 (2001), H. 22}, isbn = {0003-6951}, pages = {3678 -- 3680}, year = {2001}, language = {en} } @article{PrumeGerberRoelofsetal.2004, author = {Prume, Klaus and Gerber, P. and Roelofs, A. and K{\"u}geler, C.}, title = {Effects of the top-electrode size on the piezoelectric properties (d33 and S) of lead zirconate titanate thin films / Gerber, P. ; Roelofs, A. ; K{\"u}geler, C.; B{\"o}ttger, U. ; Waser, R. ; Prume, K. ;}, series = {Journal of Applied Physics . 96 (2004), H. 5}, journal = {Journal of Applied Physics . 96 (2004), H. 5}, isbn = {0021-8979}, pages = {2800 -- 2804}, year = {2004}, language = {en} } @article{PrumePeterRuedigeretal.2005, author = {Prume, Klaus and Peter, F. and R{\"u}diger, A. and Dittmann, R.}, title = {Analysis of shape effects on the piezoresponse in ferroelectric nanograins with and without adsorbates / Peter, F. ; R{\"u}diger, A. ; Dittmann, R. ; Waser, R. ; Szot, K. ; Reichenberg, B. ; Prume, K. ;}, series = {Applied Physics Letters . 87 (2005), H. 8}, journal = {Applied Physics Letters . 87 (2005), H. 8}, isbn = {0003-6951}, pages = {082901 -- 082901-3}, year = {2005}, language = {en} } @article{PrumeGerberKuegeleretal.2004, author = {Prume, Klaus and Gerber, Peter and K{\"u}geler, Carsten and Roelofs, Andreas}, title = {Simulation and measurements of the piezoelectric properties response (d33) of piezoelectric layered thin film structures influenced by the top-electrode size / Prume, K. ; Gerber, P. ; K{\"u}geler, C. ; Roelofs, A. ; B{\"o}ttger, U. ; Waser, R. ; Schmitz-Kempen,}, isbn = {0-7803-8410-5}, pages = {7 -- 10}, year = {2004}, language = {en} } @article{BuniatyanMatirosyanAbouzaretal.2009, author = {Buniatyan, V. V. and Matirosyan, N. W. and Abouzar, Maryam H. and Sch{\"o}ning, Michael Josef and Poghossian, Arshak and Schubert, J. and Khachatryan, V. R. and Soukiassyan, G. R.}, title = {(Ba,Sr)TiO3 based electrolyte-insulator-semiconductor pHsensors: comparitive study}, series = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, journal = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, pages = {71 -- 74}, year = {2009}, language = {en} } @article{AbouzarIngebrandtPoghossianetal.2009, author = {Abouzar, Maryam H. and Ingebrandt, S. and Poghossian, Arshak and Zhang, Y. and Moritz, W. and Sch{\"o}ning, Michael Josef}, title = {Field-effect nanoplate capacitive pH sensor based on SOI structure}, series = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, journal = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, pages = {55 -- 58}, year = {2009}, language = {en} } @article{SchoeningPoghossian2009, author = {Sch{\"o}ning, Michael Josef and Poghossian, Arshak}, title = {Silicon-based field-effect devices with nanostructured surfaces for bio-/chemical sensing}, series = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, journal = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, pages = {51 -- 53}, year = {2009}, language = {en} } @article{EngelsDoege1998, author = {Engels, Elmar and Doege, E.}, title = {Optimizing the number of strokes for punching machines using a fuzzy controlled electrohydraulic damping system / Doege, E. ; Engels, E.}, series = {ICME 98, CIRP International Seminar on Intelligent Computation in Manufacturing Engineering, Proceedings, Capri, IT, Jul 1-3, 1998}, journal = {ICME 98, CIRP International Seminar on Intelligent Computation in Manufacturing Engineering, Proceedings, Capri, IT, Jul 1-3, 1998}, address = {Capri}, pages = {471 -- 478}, year = {1998}, language = {en} } @article{MautnerForsterKornhuberetal.2008, author = {Mautner, Karin and Forster, Ralf and Kornhuber, Ralf and Sander, Oliver}, title = {Fast and Reliable Pricing of American Options with Local Volatility / Forster, Ralf ; Kornhuber, Ralf ; Mautner, Karin ; Sander, Oliver}, series = {Domain Decomposition Methods in Science and Engineering XVII}, journal = {Domain Decomposition Methods in Science and Engineering XVII}, isbn = {978-3-540-75198-4}, pages = {383 -- 390}, year = {2008}, language = {en} } @article{Jeromin2009, author = {Jeromin, G{\"u}nter Erich}, title = {Superabsorbed alcohol dehydrogenase—a new catalyst for asymmetric reductions}, series = {Biotechnology Letters. 31 (2009), H. 11}, journal = {Biotechnology Letters. 31 (2009), H. 11}, isbn = {0141-5492}, pages = {1717 -- 1721}, year = {2009}, language = {en} } @article{SelmerPinkenburg2008, author = {Selmer, Thorsten and Pinkenburg, Olaf}, title = {Method of cloning at least one nucleic acid molecule of interest using type IIS restriction endonucleases, and corresponding cloning vectors, kits and system using type IIS restriction endonucleases / Selmer, Thorsten ; Pinkenburg, Olaf}, year = {2008}, language = {en} } @article{Elbers2009, author = {Elbers, Gereon}, title = {Identification of marker peptides in hair for discrimination with regard to species and breed / Koerner, Andrea ; Ring, Maike ; Fabry, Marlies ; Elbers, Gereon ; Moeller, Martin}, series = {Proceedings of the Aachen-Dresden International Textile Conference, 3rd, Aachen, Germany, Nov. 26-27, 2009}, journal = {Proceedings of the Aachen-Dresden International Textile Conference, 3rd, Aachen, Germany, Nov. 26-27, 2009}, publisher = {DWI}, address = {Aachen}, pages = {1 CD-ROM}, year = {2009}, language = {en} } @article{BalakrishnanAndreiSelmerSelmeretal.2010, author = {Balakrishnan, Karthikeyan and Andrei-Selmer, Luminita-Cornelia and Selmer, Thorsten and Bacher, Michael and Dodel, Richard}, title = {Comparison of intravenous immunoglobulins for naturally occurring autoantibodies against amyloid-β}, series = {Journal of Alzheimer's Disease}, volume = {20}, journal = {Journal of Alzheimer's Disease}, number = {1}, publisher = {IOS Press}, address = {Amsterdam}, issn = {1387-2877}, doi = {10.3233/JAD-2010-1353}, pages = {135 -- 143}, year = {2010}, abstract = {Intravenous immunoglobulins (IVIG) are currently used for therapeutic purposes in autoimmune disorders. Recently, we demonstrated the presence of naturally occurring antibodies against amyloid- β (nAbs-Aβ) within the pool of IVIG. In this study, we compared different brands of IVIG for nAbs-Aβ and have found differences in the specificity of the nAbs-Aβ towards Aβ1-40 and Aβ1-42 . We analyzed the influence of a pH-shift over the course of antibody storage using ELISA and investigated antibody dimerization at acidic and neutral pH as well as differences in the IgG subclass distributions among the IVIG using both HPLC and a nephelometric assay. Furthermore, we investigated the epitope region of purified nAbs-Aβ. The differences found in Aβ specificity are not directly proportionate to the binding nature of these antibodies when administered in vivo. This information, however, may serve as a guide when choosing the commercial source of IVIG for therapeutic applications in Alzheimer's disease}, language = {en} } @article{AlexopoulosHoffschmidt2010, author = {Alexopoulos, Spiros and Hoffschmidt, Bernhard}, title = {Solar tower power plant in Germany and future perspectives of the development of the technology in Greece and Cyprus}, series = {Renewable Energy}, volume = {35}, journal = {Renewable Energy}, number = {7}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0960-1481}, doi = {10.1016/j.renene.2009.11.003}, pages = {1352 -- 1356}, year = {2010}, abstract = {Since the 80s power production with solar thermal power plants has been a way to substitute fossil fuels. By concentrating direct solar radiation from heliostats very high temperatures of a thermal fluid can be reached. The resulting heat is converted to mechanical energy in a steam cycle which generates electricity. High efficiencies and fast start-up are reached by using air as a heat medium, as well as using porous ceramic materials as solar receiver of the concentrated sunlight. In Germany the construction of a 1.5 MWe solar tower power plant began in 2008. It is operational since December 2008 and started production of electricity in the spring of 2009. In Greece and Cyprus, countries with high solar potential, the development of this competitive solar thermal technology is imperative, since it has already been implemented in other Mediterranean countries.}, language = {en} } @article{PhamVuTranetal.2010, author = {Pham, Phu Tinh and Vu, Khoi Duc and Tran, Thanh Ngoc and Staat, Manfred}, title = {A primal-dual algorithm for shakedown analysis of elastic-plastic bounded linearly kinematic hardening bodies}, year = {2010}, language = {en} } @article{NguyenRaatschenStaat2010, author = {Nguyen, N.-H. and Raatschen, Hans-J{\"u}rgen and Staat, Manfred}, title = {A hyperelastic model of biological tissue materials in tubular organs}, year = {2010}, language = {en} } @article{TranStaat2010, author = {Tran, Thanh Ngoc and Staat, Manfred}, title = {Shakedown analysis of two dimensional structures by an edge-based smoothed finite element method}, year = {2010}, language = {en} } @article{BuniatyanMatirosyanAbouzaretal.2009, author = {Buniatyan, Vahe V. and Matirosyan, N. and Abouzar, Maryam H. and Schubert, J. and Zander, W. and Gevorgian, S. and Sch{\"o}ning, Michael Josef and Poghossian, Arshak}, title = {Capacitive field-effect pH sensor based on an electrolyte-ferroelectric-insulator-semiconductor structure}, series = {SENSOR 2009 : : 14th International Conference on Sensors, Technologies, Electronics and Applications; N{\"u}rnberg, Germany, 26 - 28 May 2009; proceedings; [part of] Sensor + Test Conference 2009 / AMA, Fachverband f{\"u}r Sensorik e.V}, journal = {SENSOR 2009 : : 14th International Conference on Sensors, Technologies, Electronics and Applications; N{\"u}rnberg, Germany, 26 - 28 May 2009; proceedings; [part of] Sensor + Test Conference 2009 / AMA, Fachverband f{\"u}r Sensorik e.V}, publisher = {AMA Service}, address = {Wunstorf}, isbn = {9783981099355}, pages = {317 -- 322}, year = {2009}, language = {en} } @article{KirchnerLiSpelthahnetal.2009, author = {Kirchner, Patrick and Li, B. and Spelthahn, H. and Henkel, H. and Friedrich, P. and Kolstad, J. and Keusgen, M. and Sch{\"o}ning, Michael Josef}, title = {Thin-film calorimetric H2O2 gas sensor for the validation of germicidal effectivity in aseptic filling processes}, series = {Procedia Chemistry. 1 (2009), H. 1}, journal = {Procedia Chemistry. 1 (2009), H. 1}, isbn = {1876-6196}, pages = {983 -- 986}, year = {2009}, language = {en} } @article{AbouzarIngebrandtPoghossianetal.2009, author = {Abouzar, Maryam H. and Ingebrandt, S. and Poghossian, Arshak and Zhang, Y. and Vu, X. T. and Moritz, W. and Sch{\"o}ning, Michael Josef}, title = {Nanoplate field-effect capacitive (bio-)chemical sensor array based on SOI structure}, series = {Procedia Chemistry. 1 (2009), H. 1}, journal = {Procedia Chemistry. 1 (2009), H. 1}, isbn = {1876-6196}, pages = {670 -- 673}, year = {2009}, language = {en} } @article{GasparyanPoghossianVitusevichetal.2009, author = {Gasparyan, F. V. and Poghossian, Arshak and Vitusevich, S. A. and Petrychuk, M. V. and Sydoruk, V. A. and Surmalyan, A. V. and Siqueira, J. R. and Oliveira, O. N. and Offenh{\"a}usser, A. and Sch{\"o}ning, Michael Josef}, title = {Low Frequency Noise In Electrolyte-Gate Field-Effect Devices Functionalized With Dendrimer/Carbon-Nanotube Multilayers}, series = {Noise and fluctuations : 20th International Conference on Noise and Fluctuations, ICNF 2009, Pisa, Italy, 14 - 19 June 2009 / ed. Massimo Macucci; Giovanni Basso}, journal = {Noise and fluctuations : 20th International Conference on Noise and Fluctuations, ICNF 2009, Pisa, Italy, 14 - 19 June 2009 / ed. Massimo Macucci; Giovanni Basso}, publisher = {American Inst. of Physics}, address = {Melville, NY}, isbn = {9780735406650}, pages = {133 -- 136}, year = {2009}, language = {en} } @article{MiyamotoWagnerMimuraetal.2009, author = {Miyamoto, Ko-ichiro and Wagner, Torsten and Mimura, Shuhei and Kanoh, Shin`ichiro and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {Constant-phase-mode operation of the light-addressable potentiometric sensor}, series = {Procedia Chemistry. 1 (2009), H. 1}, journal = {Procedia Chemistry. 1 (2009), H. 1}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1876-6196}, pages = {1487 -- 1490}, year = {2009}, language = {en} } @article{PoghossianKraemerAbouzaretal.2009, author = {Poghossian, Arshak and Kr{\"a}mer, Melina and Abouzar, Maryam H. and Pita, Marcos and Katz, Evgeny and Sch{\"o}ning, Michael Josef}, title = {Interfacing of biocomputing systems with silicon chips: Enzyme logic gates based on field-effect devices}, series = {Procedia Chemistry. 1 (2009), H. 1}, journal = {Procedia Chemistry. 1 (2009), H. 1}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1876-6196}, pages = {682 -- 685}, year = {2009}, language = {en} } @article{PoghossianWagnerSchoening2009, author = {Poghossian, Arshak and Wagner, Holger and Sch{\"o}ning, Michael Josef}, title = {Functional testing and characterisation of (bio-)chemical sensors on wafer level}, series = {Procedia Chemistry. 1 (2009), H. 1}, journal = {Procedia Chemistry. 1 (2009), H. 1}, isbn = {1876-6196}, pages = {835 -- 838}, year = {2009}, language = {en} } @article{WagnerWernerMiyamotoetal.2009, author = {Wagner, Torsten and Werner, Frederik and Miyamoto, K. and Sch{\"o}ning, Michael Josef and Yoshinobu, T.}, title = {A high-density multi-point LAPS set-up using a VCSEL array and FPGA control}, series = {Procedia Chemistry. 1 (2009), H. 1}, journal = {Procedia Chemistry. 1 (2009), H. 1}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1876-6196}, pages = {1483 -- 1486}, year = {2009}, language = {en} } @article{BaeckerPoghossianAbouzaretal.2010, author = {B{\"a}cker, Matthias and Poghossian, Arshak and Abouzar, Maryam H. and Wenmackers, Sylvia and Janssens, Stoffel D. and Haenen, Ken and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Capacitive field-effect (bio-)chemical sensors based on nanocrystalline diamond films}, series = {MRS Online Proceedings Library}, volume = {1203}, journal = {MRS Online Proceedings Library}, publisher = {MRS}, address = {Warrendale}, issn = {1946-4274}, year = {2010}, abstract = {Capacitive field-effect electrolyte-diamond-insulator-semiconductor (EDIS) structures with O-terminated nanocrystalline diamond (NCD) as sensitive gate material have been realized and investigated for the detection of pH, penicillin concentration, and layer-by-layer adsorption of polyelectrolytes. The surface oxidizing procedure of NCD thin films as well as the seeding and NCD growth process on a Si-SiO2 substrate have been improved to provide high pH-sensitive, non-porous thin films without damage of the underlying SiO2 layer and with a high coverage of O-terminated sites. The NCD surface topography, roughness, and coverage of the surface groups have been characterized by SEM, AFM and XPS methods. The EDIS sensors with O-terminated NCD film treated in oxidizing boiling mixture for 45 min show a pH sensitivity of about 50 mV/pH. The pH-sensitive properties of the NCD have been used to develop an EDIS-based penicillin biosensor with high sensitivity (65-70 mV/decade in the concentration range of 0.25-2.5 mM penicillin G) and low detection limit (5 μM). The results of label-free electrical detection of layer-by-layer adsorption of charged polyelectrolytes are presented, too.}, language = {en} } @article{BegingMlynekHataihimakuletal.2010, author = {Beging, Stefan and Mlynek, Daniela and Hataihimakul, Sudkanung and Poghossian, Arshak and Baldsiefen, Gerhard and Busch, Heinz and Laube, Norbert and Kleinen, Lisa and Sch{\"o}ning, Michael Josef}, title = {Field-effect calcium sensor for the determination of the risk of urinary stone formation}, series = {Sensors and Actuators B: Chemical}, volume = {144}, journal = {Sensors and Actuators B: Chemical}, number = {2}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2008.12.012}, pages = {374 -- 379}, year = {2010}, abstract = {Urinary stone formation has been evolved to a widespread disease during the last years. The reason for the formation of urinary stones are little crystals, mostly composed of calcium oxalate, which are formed in human kidneys. The early diagnosis of the risk for urinary stone formation of patients can be determined by the "Bonn-Risk-Index" method based on the potentiometric detection of the Ca2+-ion concentration and an optical determination of the triggered crystallisation of calcium oxalate in unprocessed urine. In this work, miniaturised capacitive field-effect EMIS (electrolyte-membrane-insulator-semiconductor) sensors have been developed for the determination of the Ca2+-ion concentration in human native urine. The Ca2+-sensitive EMIS sensors have been systematically characterised by impedance spectroscopy, capacitance-voltage and constant-capacitance method in terms of sensitivity, signal stability and response time in both CaCl2 solutions and in native urine. The obtained results demonstrate the suitability of EMIS sensors for the measurement of the Ca2+-ion concentration in native urine of patients.}, language = {en} } @article{ReisertHenkelSchneideretal.2010, author = {Reisert, Steffen and Henkel, Hartmut and Schneider, Andreas and Sch{\"a}fer, Daniel and Friedrich, Peter and Berger, J{\"o}rg and Sch{\"o}ning, Michael Josef}, title = {Development of a handheld sensor system for the online measurement of hydrogen peroxide in aseptic filling systems}, series = {Physica Status Solidi (A)}, volume = {207}, journal = {Physica Status Solidi (A)}, number = {4}, publisher = {Wiley-VCH}, address = {Berlin}, issn = {1862-6300}, doi = {10.1002/pssa.200983304}, pages = {913 -- 918}, year = {2010}, abstract = {A handheld sensor system for the online measurement of hydrogen peroxide (H2O2) in aseptic sterilisation processes has been developed. It is based on a calorimetric-type gas sensor that consists of a differential set-up of two temperature sensors, of which one is catalytically activated and the second one is passivated and used as reference. The sensor principle relies in detecting a rise in temperature on the active sensor due to the exothermic reaction of H2O2 on the catalytic surface. To characterise the sensor system towards H2O2 sensitivity and other influencing factors, measurements have been carried out both at an experimental set-up and a manufacturer's sterilisation machine. Physical sensor characterisation was done by means of the optical microscopy.}, language = {en} } @article{MiyamotoSugawaraKanohetal.2010, author = {Miyamoto, Ko-ichiro and Sugawara, Yuri and Kanoh, Shin´ichiro and Yoshinobu, Tatsuo and Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Image correction method for the chemical imaging sensor}, series = {Sensors and Actuators B: Chemical}, volume = {144}, journal = {Sensors and Actuators B: Chemical}, number = {2}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2008.10.069}, pages = {344 -- 348}, year = {2010}, abstract = {The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of chemical species. For the practical application of this sensor, artifacts in the chemical images due to defects of the semiconductor substrate and contamination of the sensing surface etc. have been a major problem. An image correction method was developed to eliminate the influence of nonuniformity of individual sensor plate.}, language = {en} } @article{AbouzarPoghossianSiqueiraetal.2010, author = {Abouzar, Maryam H. and Poghossian, Arshak and Siqueira, Jos{\´e} R. Jr. and Oliveira, Osvaldo N. Jr. and Moritz, Werner and Sch{\"o}ning, Michael Josef}, title = {Capacitive electrolyte-insulator-semiconductor structures functionalised with a polyelectrolyte/enzyme multilayer: New strategy for enhanced field-effect biosensing}, series = {Physica Status Solidi (A)}, volume = {207}, journal = {Physica Status Solidi (A)}, number = {4}, publisher = {Wiley-VCH}, address = {Berlin}, issn = {1862-6300}, doi = {10.1002/pssa.200983317}, pages = {884 -- 890}, year = {2010}, abstract = {A novel strategy for enhanced field-effect biosensing using capacitive electrolyte-insulator-semiconductor (EIS) structures functionalised with pH-responsive weak polyelectrolyte/enzyme or dendrimer/enzyme multilayers is presented. The feasibility of the proposed approach is exemplarily demonstrated by realising a penicillin biosensor based on a capacitive p-Si-SiO2 EIS structure functionalised with a poly(allylamine hydrochloride) (PAH)/penicillinase and a poly(amidoamine) dendrimer/penicillinase multilayer. The developed sensors response to changes in both the local pH value near the gate surface and the charge of macromolecules induced via enzymatic reaction, resulting in a higher sensitivity. For comparison, an EIS penicillin biosensor with adsorptively immobilised penicillinase has been also studied. The highest penicillin sensitivity of 100 mV/dec has been observed for the EIS sensor functionalised with the PAH/penicillinase multilayer. The lower and upper detection limit was around 20 µM and 10 mM, respectively. In addition, an incorporation of enzymes in a multilayer prepared by layer-by-layer technique provides a larger amount of immobilised enzymes per sensor area, reduces enzyme leaching effects and thus, enhances the biosensor lifetime (the loss of penicillin sensitivity after 2 months was 10-12\%).}, language = {en} } @article{SchoeningKirchnerNgetal.2010, author = {Sch{\"o}ning, Michael Josef and Kirchner, Patrick and Ng, Yue Ann and Spelthahn, Heiko and Schneider, Andreas and Henkel, Hartmut and Friedrich, Peter and Kolstad, Jens and Berger, J{\"o}rg and Keusgen, Michael}, title = {Gas sensor investigation based on a catalytically activated thin-film thermopile for H2O2 detection}, series = {Physica Status Solidi (A)}, volume = {207}, journal = {Physica Status Solidi (A)}, number = {4}, publisher = {Wiley-VCH}, address = {Berlin}, issn = {1862-6300}, doi = {10.1002/pssa.200983309}, pages = {787 -- 792}, year = {2010}, abstract = {In aseptic filling systems, hydrogen peroxide vapour is commonly used for the reduction of microbial contaminations in carton packages. In this process, the germicidal efficiency of the vapour depends especially on the H₂O₂ concentration. To monitor the H₂O₂ concentration, a calorimetric H₂O₂ gas sensor based on a catalytically activated thin-film thermopile is investigated. Two different sensor layouts, namely a circular and a linear form, as well as two various material pairs such as tungsten/nickel and gold/nickel, have been examined for the realization of a thin-film thermopile. Additionally, manganese oxide and palladium particles have been compared as responsive catalysts towards H₂O₂. The thin-film sensors have been investigated at various H₂O₂ concentrations, gas temperatures and flow rates.}, language = {en} } @article{BuniatyanAbouzarMartirosyanetal.2010, author = {Buniatyan, Vahe V. and Abouzar, Maryam H. and Martirosyan, Norayr W. and Schubert, J{\"u}rgen and Gevorgian, Spartak and Sch{\"o}ning, Michael Josef and Poghossian, Arshak}, title = {pH-sensitive properties of barium strontium titanate (BST) thin films prepared by pulsed laser deposition technique}, series = {Physica Status Solidi (A)}, volume = {207}, journal = {Physica Status Solidi (A)}, number = {4}, publisher = {Wiley-VCH}, address = {Berlin}, issn = {1862-6300}, doi = {10.1002/pssa.200983310}, pages = {824 -- 830}, year = {2010}, abstract = {pH-sensitive properties of barium strontium titanate (BST) high-k thin films as alternative gate material for field-effect capacitive (bio-)chemical sensors based on an electrolyte-insulator-semiconductor system have been investigated. The BST films of different compositions (Ba0.31Sr0.69TiO3, Ba0.25Sr0.75TiO3 and Mg-doped Ba0.8Sr0.2Mg0.1Ti0.9O3) were deposited by pulsed laser deposition technique from targets fabricated by self-propagating high-temperature synthesis. The realised sensors have been electrochemically characterised by means of impedance-spectroscopy, capacitance-voltage and constant-capacitance method. The sensors possess a Nernstian-like pH sensitivity in the concentration range between pH 3 and 11 with a response time of 5-10 s. An equivalent circuit model for the BST-based capacitive field-effect sensor is discussed.}, language = {en} } @article{TurekHeidenGuoetal.2010, author = {Turek, Monik and Heiden, Wolfgang and Guo, Sharon and Riesen, Alfred and Schubert, J{\"u}rgen and Zander, Willi and Kr{\"u}ger, Peter and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Simultaneous detection of cyanide and heavy metals for environmental analysis by means of µISEs}, series = {Physica Status Solidi (A)}, volume = {207}, journal = {Physica Status Solidi (A)}, number = {4}, publisher = {Wiley-VCH}, address = {Berlin}, issn = {1862-6300}, doi = {10.1002/pssa.200983303}, pages = {817 -- 823}, year = {2010}, abstract = {In environmental analysis, cyanide and heavy metals play an important role, because these substances are highly toxic for biological systems. They can lead to chronic and acute diseases. Due to the chemical properties of cyanide it is frequently used for industrial processes such as extraction of silver and gold. Heavy metals can be found as trace elements in nature and are often applied in industries e.g., galvanization processes. Up to now, cyanide and heavy metals can be detected by several sensors separately and their detection is often limited to laboratory investigations. In this publication, with regard to an in situ analysis, a new miniaturized silicon-based sensor system for the simultaneous detection of cyanide and heavy metals in aqueous solutions is presented that is based on chalcogenide glass-based micro ion-selective electrodes (µISEs). The µISEs are incorporated into a specially designed measuring system for the simultaneous detection of heavy metals and cyanide in solutions and validated by simultaneous measurements of Cu2+- and CN--ions, Cd2+- and CN-- ions and Pb2+- and CN--ions. The particular sensor system has shown good sensor properties in the µ-molar ion-concentration range. For simultaneous measurements in complex heavy metal and cyanide solutions an intelligent software using fuzzy logic is discussed.}, language = {en} } @article{SiqueiraBaeckerPoghossianetal.2010, author = {Siqueira, Jos{\´e} R. Jr. and B{\"a}cker, Matthias and Poghossian, Arshak and Zucolotto, Valtencir and Oliveira, Osvaldo N. Jr. and Sch{\"o}ning, Michael Josef}, title = {Associating biosensing properties with the morphological structure of multilayers containing carbon nanotubes on field-effect devices}, series = {Physica Status Solidi (A)}, volume = {207}, journal = {Physica Status Solidi (A)}, number = {4}, publisher = {Wiley-VCH}, address = {Berlin}, issn = {1862-6300}, doi = {10.1002/pssa.200983301}, pages = {781 -- 786}, year = {2010}, abstract = {The control of molecular architecture provided by the layer-by-layer (LbL) technique has led to enhanced biosensors, in which advantageous features of distinct materials can be combined. Full optimization of biosensing performance, however, is only reached if the film morphology is suitable for the principle of detection of a specific biosensor. In this paper, we report a detailed morphology analysis of LbL films made with alternating layers of single-walled carbon nanotubes (SWNTs) and polyamidoamine (PAMAM) dendrimers, which were then covered with a layer of penicillinase (PEN). An optimized performance to detect penicillin G was obtained with 6-bilayer SWNT/PAMAM LbL films deposited on p-Si-SiO2-Ta2O5 chips, used in biosensors based on a capacitive electrolyte-insulator-semiconductor (EIS) and a light-addressable potentiometric sensor (LAPS) structure, respectively. Field-emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM) images indicated that the LbL films were porous, with a large surface area due to interconnection of SWNT into PAMAM layers. This morphology was instrumental for the adsorption of a larger quantity of PEN, with the resulting LbL film being highly stable. The experiments to detect penicillin were performed with constant-capacitance (ConCap) and constant-current (CC) measurements for EIS and LAPS sensors, respectively, which revealed an enhanced detection signal and sensitivity of ca. 100 mV/decade for the field-effect sensors modified with the PAMAM/SWNT LbL film. It is concluded that controlling film morphology is essential for an enhanced performance of biosensors, not only in terms of sensitivity but also stability and response time.}, language = {en} } @article{UllrichGrottkeRossaintetal.2010, author = {Ullrich, Sebastian and Grottke, Oliver and Rossaint, Rolf and Staat, Manfred and Deserno, Thomas M. and Kuhlen, Torsten}, title = {Virtual Needle Simulation with Haptics for Regional Anaesthesia}, pages = {3 Seiten}, year = {2010}, language = {en} } @article{SchwarzerSilva2008, author = {Schwarzer, Klemens and Silva, Maria Eugenia Vieira da}, title = {Characterisation and design methods of solar cookers / Schwarzer, Klemens ; Silva, Maria Eugenia Vieira da}, series = {Solar energy. 82 (2008), H. 2}, journal = {Solar energy. 82 (2008), H. 2}, isbn = {0038-092X}, pages = {157 -- 163}, year = {2008}, language = {en} } @article{SchoeningTurekHeidenetal.2009, author = {Sch{\"o}ning, Michael Josef and Turek, M. and Heiden, W. and Riesen, A. and Chhabda, T. A. and Schubert, J. and Kr{\"u}ger, P. and Keusgen, M.}, title = {Artificial intelligence/fuzzy logic method for analysis of combined signals from heavy metal chemical sensors}, series = {Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI}, journal = {Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI}, publisher = {Elsevier}, address = {New York}, isbn = {0013-4686}, pages = {6082 -- 6088}, year = {2009}, language = {en} } @article{BaeckerBegingBisellietal.2009, author = {B{\"a}cker, Matthias and Beging, Stefan and Biselli, Manfred and Poghossian, Arshak and Wang, J. and Zang, Werner and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Concept for a solid-state multi-parameter sensor system for cell-culture monitoring}, series = {Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI}, journal = {Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {0013-4686}, pages = {6107 -- 6112}, year = {2009}, language = {en} } @article{SpelthahnPoghossianSchoening2009, author = {Spelthahn, Heiko and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Self-aligned nanogaps and nanochannels via conventional photolithography and pattern-size reduction technique}, series = {Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI}, journal = {Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI}, isbn = {0013-4686}, pages = {6010 -- 6014}, year = {2009}, language = {en} }