@article{ValeroBung2018, author = {Valero, Daniel and Bung, Daniel B.}, title = {Vectrino profiler spatial filtering for shear flows based on the mean velocity gradient equation}, series = {Journal of Hydraulic Engineering}, volume = {144}, journal = {Journal of Hydraulic Engineering}, number = {7}, publisher = {ASCE}, address = {Reston, Va.}, issn = {0733-9429}, doi = {10.1061/(ASCE)HY.1943-7900.0001485}, year = {2018}, abstract = {A new methodology is proposed to spatially filter acoustic Doppler velocimetry data from a Vectrino profiler based on the differential mean velocity equation. Lower and upper bounds are formulated in terms of physically based flow constraints. Practical implementation is discussed, and its application is tested against data gathered from an open-channel flow over a stepped macroroughness surface. The method has proven to detect outliers occurring all over the distance range sampled by the Vectrino profiler and has shown to remain applicable out of the region of validity of the velocity gradient equation. Finally, a statistical analysis suggests that physically obtained bounds are asymptotically representative.}, language = {en} } @article{BienerSasseWernhoff2003, author = {Biener, Ernst and Sasse, T. and Wernhoff, T.}, title = {Using harbour dredged material for combination sealing of the former Bockhorner Weg disposal site in Bremen, Germany}, series = {Proceedings of the International Harbour Congress. 13 (2003)}, journal = {Proceedings of the International Harbour Congress. 13 (2003)}, pages = {101 -- 109}, year = {2003}, language = {en} } @article{ValeroBungErpicumetal.2022, author = {Valero, Daniel and Bung, Daniel B. and Erpicum, Sebastien and Peltier, Yann and Dewals, Benjamin}, title = {Unsteady shallow meandering flows in rectangular reservoirs: a modal analysis of URANS modelling}, series = {Journal of Hydro-environment Research}, journal = {Journal of Hydro-environment Research}, number = {In Press}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1570-6443}, doi = {10.1016/j.jher.2022.03.002}, year = {2022}, abstract = {Shallow flows are common in natural and human-made environments. Even for simple rectangular shallow reservoirs, recent laboratory experiments show that the developing flow fields are particularly complex, involving large-scale turbulent structures. For specific combinations of reservoir size and hydraulic conditions, a meandering jet can be observed. While some aspects of this pseudo-2D flow pattern can be reproduced using a 2D numerical model, new 3D simulations, based on the unsteady Reynolds-Averaged Navier-Stokes equations, show consistent advantages as presented herein. A Proper Orthogonal Decomposition was used to characterize the four most energetic modes of the meandering jet at the free surface level, allowing comparison against experimental data and 2D (depth-averaged) numerical results. Three different isotropic eddy viscosity models (RNG k-ε, k-ε, k-ω) were tested. The 3D models accurately predicted the frequency of the modes, whereas the amplitudes of the modes and associated energy were damped for the friction-dominant cases and augmented for non-frictional ones. The performance of the three turbulence models remained essentially similar, with slightly better predictions by RNG k-ε model in the case with the highest Reynolds number. Finally, the Q-criterion was used to identify vortices and study their dynamics, assisting on the identification of the differences between: i) the three-dimensional phenomenon (here reproduced), ii) its two-dimensional footprint in the free surface (experimental observations) and iii) the depth-averaged case (represented by 2D models).}, language = {en} } @article{FellinKingKirschetal.2010, author = {Fellin, Wolfgang and King, Julian and Kirsch, Ansgar and Oberguggenberger, Michael}, title = {Uncertainty modelling and sensitivity analysis of tunnel face stability}, series = {Structural safety}, volume = {32}, journal = {Structural safety}, number = {6}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0167-4730}, doi = {10.1016/j.strusafe.2010.06.001}, pages = {402 -- 410}, year = {2010}, abstract = {This paper proposes an approach to the choice and evaluation of engineering models with the aid of a typical application in geotechnics. An important issue in the construction of shallow tunnels, especially in weak ground conditions, is the tunnel face stability. Various theoretical and numerical models for predicting the necessary support pressure have been put forth in the literature. In this paper, we combine laboratory experiments performed at the University of Innsbruck with current methods of uncertainty and sensitivity analysis for assessing adequacy, predictive power and robustness of the models. The major issues are the handling of the twofold uncertainty of test results and of model predictions as well as the decision about what are the influential input parameters.}, language = {en} } @article{BungCrookstonValero2020, author = {Bung, Daniel B. and Crookston, Brian M. and Valero, Daniel}, title = {Turbulent free-surface monitoring with an RGB-D sensor: the hydraulic jump case}, series = {Journal of Hydraulic Research}, journal = {Journal of Hydraulic Research}, publisher = {Taylor \& Francis}, address = {London}, issn = {1814-2079}, doi = {10.1080/00221686.2020.1844810}, year = {2020}, language = {en} } @article{Hoettges1990, author = {H{\"o}ttges, J{\"o}rg}, title = {Turbulence and Mixing Mechanics in Compound Open Channel Flow / Arnold, Uwe; H{\"o}ttges, J{\"o}rg; Rouv{\´e}, Gerhard}, series = {On cutoff ratios of curved channels : paper presented at the 23rd Congress of the IAHR, Ottawa, Canada, August 21 - 25, 1989 / G. J. Klaassen; B. H. J.van Zanten}, journal = {On cutoff ratios of curved channels : paper presented at the 23rd Congress of the IAHR, Ottawa, Canada, August 21 - 25, 1989 / G. J. Klaassen; B. H. J.van Zanten}, publisher = {Delft Hydraulics}, address = {Delft}, year = {1990}, language = {en} } @article{KramerValeroChansonetal.2019, author = {Kramer, Matthias and Valero, Daniel and Chanson, Hubert and Bung, Daniel B.}, title = {Towards reliable turbulence estimations with phase-detection probes: an adaptive window cross-correlation technique}, series = {Experiments in Fluids}, volume = {60}, journal = {Experiments in Fluids}, publisher = {Springer}, address = {Berlin}, issn = {1432-1114}, doi = {10.1007/s00348-018-2650-9}, year = {2019}, language = {en} } @article{HagenkampBlankeDoering2021, author = {Hagenkamp, Markus and Blanke, Tobias and D{\"o}ring, Bernd}, title = {Thermoelectric building temperature control: a potential assessment}, series = {International Journal of Energy and Environmental Engineering}, volume = {13}, journal = {International Journal of Energy and Environmental Engineering}, publisher = {Springer}, address = {Berlin}, doi = {10.1007/s40095-021-00424-x}, pages = {241 -- 254}, year = {2021}, abstract = {This study focuses on thermoelectric elements (TEE) as an alternative for room temperature control. TEE are semi-conductor devices that can provide heating and cooling via a heat pump effect without direct noise emissions and no refrigerant use. An efficiency evaluation of the optimal operating mode is carried out for different numbers of TEE, ambient temperatures, and heating loads. The influence of an additional heat recovery unit on system efficiency and an unevenly distributed heating demand are examined. The results show that TEE can provide heat at a coefficient of performance (COP) greater than one especially for small heating demands and high ambient temperatures. The efficiency increases with the number of elements in the system and is subject to economies of scale. The best COP exceeds six at optimal operating conditions. An additional heat recovery unit proves beneficial for low ambient temperatures and systems with few TEE. It makes COPs above one possible at ambient temperatures below 0 ∘C. The effect increases efficiency by maximal 0.81 (from 1.90 to 2.71) at ambient temperature 5 K below room temperature and heating demand Q˙h=100W but is subject to diseconomies of scale. Thermoelectric technology is a valuable option for electricity-based heat supply and can provide cooling and ventilation functions. A careful system design as well as an additional heat recovery unit significantly benefits the performance. This makes TEE superior to direct current heating systems and competitive to heat pumps for small scale applications with focus on avoiding noise and harmful refrigerants.}, language = {en} } @article{DoeringKendrickLawson2013, author = {D{\"o}ring, Bernd and Kendrick, C. and Lawson, R. M.}, title = {Thermal capacity of composite floor slabs}, series = {Energy and buildings}, volume = {Vol. 67}, journal = {Energy and buildings}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1872-6178 (E-Journal); 0378-7788 (Print)}, pages = {531 -- 539}, year = {2013}, language = {en} } @article{DoeringRegerKuhnhenneetal.2015, author = {D{\"o}ring, Bernd and Reger, Vitali and Kuhnhenne, Markus and Feldmann, Markus and Kesti, Jyrki and Lawson, Mark and Botti, Andrea}, title = {Steel solutions for enabling zero-energy buildings}, series = {Steel Construction - Design and Research}, volume = {8}, journal = {Steel Construction - Design and Research}, number = {3}, publisher = {Ernst \& Sohn}, address = {Berlin}, issn = {1867-0539}, doi = {10.1002/stco.201510029}, pages = {194 -- 200}, year = {2015}, language = {en} }