@inproceedings{WeberTersteggeHallingetal.1995, author = {Weber, S. and Terstegge, Andreas and Halling, H. and Herzog, H. and Reinartz, R. and Reinhart, P. and Rongen, F. and M{\"u}ller-G{\"a}rtner, H.-W.}, title = {The design of an animal PET: flexible geometry for achieving optimal spatial resolution or high sensitivity}, series = {Conference record / 1995 IEEE Nuclear Science Symposium and Medical Imaging, October 21 - 28, 1995, San Francisco ; vol. 2}, booktitle = {Conference record / 1995 IEEE Nuclear Science Symposium and Medical Imaging, October 21 - 28, 1995, San Francisco ; vol. 2}, publisher = {IEEE}, address = {Piscataway, NJ}, organization = {Institute of Electrical and Electronics Engineers}, isbn = {078033180X ; 0780331818 ; 0780331826}, pages = {1002 -- 1005}, year = {1995}, language = {en} } @inproceedings{WeberTersteggeEngelsetal.1996, author = {Weber, S. and Terstegge, Andreas and Engels, R. and Herzog, H. and Reinartz, R. and Reinhart, P. and Rongen, F. and M{\"u}ller-G{\"a}rtner, H. W. and Halling, H.}, title = {The KFA TierPET: performance characteristics and measurements}, series = {Conference record / 1996 IEEE Nuclear Science Symposium [and Medical Imaging], November 2 - 9, 1996, Anaheim, California ; vol. 2}, booktitle = {Conference record / 1996 IEEE Nuclear Science Symposium [and Medical Imaging], November 2 - 9, 1996, Anaheim, California ; vol. 2}, publisher = {IEEE}, address = {Piscataway, NJ}, organization = {Institute of Electrical and Electronics Engineers}, isbn = {0-7803-3534-1}, issn = {1082-3654}, pages = {1117 -- 1119}, year = {1996}, language = {en} } @article{BussmannEngelsFussetal.2000, author = {Bussmann, N. and Engels, R. and Fuss, L. and Kemmerling, G. and Reinartz, R. and Langen, K.-J. and Schelten, J. and Ziemons, Karl}, title = {Performance measurement of a new high resolution detector system for I-131 thyroid studies}, series = {2000 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, journal = {2000 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, issn = {1082-3654}, pages = {22/35 -- 22/37}, year = {2000}, abstract = {A 2-dimensional detector system for high resolution thyroid I-131 scintigraphy was developed. It has a sensitive area of 4 cm×4 cm and consists of a lead-collimator and an array of 10×10 EGO crystals combined with a position sensitive photomultiplier. The spatial resolution and the sensitivity of the detector has been measured and compared to two commercially available gamma-cameras. Furthermore first patient measurements have been carried out}, language = {de} }