@article{SchwagerFleschSchwarzboezletal.2022, author = {Schwager, Christian and Flesch, Robert and Schwarzb{\"o}zl, Peter and Herrmann, Ulf and Teixeira Boura, Cristiano Jos{\´e}}, title = {Advanced two phase flow model for transient molten salt receiver system simulation}, series = {Solar Energy}, volume = {232}, journal = {Solar Energy}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0038-092X (print)}, doi = {10.1016/j.solener.2021.12.065}, pages = {362 -- 375}, year = {2022}, abstract = {In order to realistically predict and optimize the actual performance of a concentrating solar power (CSP) plant sophisticated simulation models and methods are required. This paper presents a detailed dynamic simulation model for a Molten Salt Solar Tower (MST) system, which is capable of simulating transient operation including detailed startup and shutdown procedures including drainage and refill. For appropriate representation of the transient behavior of the receiver as well as replication of local bulk and surface temperatures a discretized receiver model based on a novel homogeneous two-phase (2P) flow modelling approach is implemented in Modelica Dymola®. This allows for reasonable representation of the very different hydraulic and thermal properties of molten salt versus air as well as the transition between both. This dynamic 2P receiver model is embedded in a comprehensive one-dimensional model of a commercial scale MST system and coupled with a transient receiver flux density distribution from raytracing based heliostat field simulation. This enables for detailed process prediction with reasonable computational effort, while providing data such as local salt film and wall temperatures, realistic control behavior as well as net performance of the overall system. Besides a model description, this paper presents some results of a validation as well as the simulation of a complete startup procedure. Finally, a study on numerical simulation performance and grid dependencies is presented and discussed.}, language = {en} } @inproceedings{SchwagerAngeleSchwarzboezletal.2023, author = {Schwager, Christian and Angele, Florian and Schwarzb{\"o}zl, Peter and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf}, title = {Model predictive assistance for operational decision making in molten salt receiver systems}, series = {SolarPACES: Solar Power \& Chemical Energy Systems}, booktitle = {SolarPACES: Solar Power \& Chemical Energy Systems}, number = {2815 / 1}, publisher = {AIP conference proceedings / American Institute of Physics}, address = {Melville, NY}, isbn = {978-0-7354-4623-6}, issn = {1551-7616 (online)}, doi = {10.1063/5.0151514}, pages = {8 Seiten}, year = {2023}, abstract = {Despite the challenges of pioneering molten salt towers (MST), it remains the leading technology in central receiver power plants today, thanks to cost effective storage integration and high cost reduction potential. The limited controllability in volatile solar conditions can cause significant losses, which are difficult to estimate without comprehensive modeling [1]. This paper presents a Methodology to generate predictions of the dynamic behavior of the receiver system as part of an operating assistance system (OAS). Based on this, it delivers proposals if and when to drain and refill the receiver during a cloudy period in order maximize the net yield and quantifies the amount of net electricity gained by this. After prior analysis with a detailed dynamic two-phase model of the entire receiver system, two different reduced modeling approaches where developed and implemented in the OAS. A tailored decision algorithm utilizes both models to deliver the desired predictions efficiently and with appropriate accuracy.}, language = {en} } @inproceedings{SchwagerAngeleNourietal.2022, author = {Schwager, Christian and Angele, Florian and Nouri, Bijan and Schwarzb{\"o}zl, Peter and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf}, title = {Impact of DNI forecast quality on performance prediction for a commercial scale solar tower: Application of nowcasting DNI maps to dynamic solar tower simulation}, series = {SolarPACES conference proceedings}, booktitle = {SolarPACES conference proceedings}, number = {Vol. 1}, publisher = {TIB Open Publishing}, address = {Hannover}, issn = {2751-9899 (online)}, doi = {10.52825/solarpaces.v1i.675}, pages = {9 Seiten}, year = {2022}, abstract = {Concerning current efforts to improve operational efficiency and to lower overall costs of concentrating solar power (CSP) plants with prediction-based algorithms, this study investigates the quality and uncertainty of nowcasting data regarding the implications for process predictions. DNI (direct normal irradiation) maps from an all-sky imager-based nowcasting system are applied to a dynamic prediction model coupled with ray tracing. The results underline the need for high-resolution DNI maps in order to predict net yield and receiver outlet temperature realistically. Furthermore, based on a statistical uncertainty analysis, a correlation is developed, which allows for predicting the uncertainty of the net power prediction based on the corresponding DNI forecast uncertainty. However, the study reveals significant prediction errors and the demand for further improvement in the accuracy at which local shadings are forecasted.}, language = {en} } @article{SattlerRoegerSchwarzboezletal.2020, author = {Sattler, Johannes, Christoph and R{\"o}ger, Marc and Schwarzb{\"o}zl, Peter and Buck, Reiner and Macke, Ansgar and Raeder, Christian and G{\"o}ttsche, Joachim}, title = {Review of heliostat calibration and tracking control methods}, series = {Solar Energy}, volume = {207}, journal = {Solar Energy}, publisher = {Elsevier}, address = {Amsterdam}, doi = {10.1016/j.solener.2020.06.030}, pages = {110 -- 132}, year = {2020}, abstract = {Large scale central receiver systems typically deploy between thousands to more than a hundred thousand heliostats. During solar operation, each heliostat is aligned individually in such a way that the overall surface normal bisects the angle between the sun's position and the aim point coordinate on the receiver. Due to various tracking error sources, achieving accurate alignment ≤1 mrad for all the heliostats with respect to the aim points on the receiver without a calibration system can be regarded as unrealistic. Therefore, a calibration system is necessary not only to improve the aiming accuracy for achieving desired flux distributions but also to reduce or eliminate spillage. An overview of current larger-scale central receiver systems (CRS), tracking error sources and the basic requirements of an ideal calibration system is presented. Leading up to the main topic, a description of general and specific terms on the topics heliostat calibration and tracking control clarifies the terminology used in this work. Various figures illustrate the signal flows along various typical components as well as the corresponding monitoring or measuring devices that indicate or measure along the signal (or effect) chain. The numerous calibration systems are described in detail and classified in groups. Two tables allow the juxtaposition of the calibration methods for a better comparison. In an assessment, the advantages and disadvantages of individual calibration methods are presented.}, language = {en} } @inproceedings{PompSchwarzboezlKolletal.2010, author = {Pomp, Stefan and Schwarzb{\"o}zl, Peter and Koll, Gerrit and Hennecke, Klaus and Schmitz, Mark and Hoffschmidt, Bernhard}, title = {Advanced concept for a solar thermal power plant with open volumetric air receiver}, series = {SolarPACES 2010 : the CSP Conference: electricity, fuels and clean water from concentrated solar energy ; 21 to 24 September 2010, Perpignan, France}, booktitle = {SolarPACES 2010 : the CSP Conference: electricity, fuels and clean water from concentrated solar energy ; 21 to 24 September 2010, Perpignan, France}, publisher = {Soc. OSC}, address = {Saint Maur}, pages = {97 -- 98}, year = {2010}, language = {en} } @inproceedings{SchwarzboezlPompKolletal.2010, author = {Schwarzb{\"o}zl, Peter and Pomp, Stefan and Koll, Gerrit and Hennecke, Klaus and Hartz, Thomas and Schmitz, Mark and Hoffschmidt, Bernhard}, title = {The solar tower J{\"u}lich - first operational experiences and test results}, series = {SolarPACES 2010 : the CSP Conference: electricity, fuels and clean water from concentrated solar energy ; 21 to 24 September 2010, Perpignan, France}, booktitle = {SolarPACES 2010 : the CSP Conference: electricity, fuels and clean water from concentrated solar energy ; 21 to 24 September 2010, Perpignan, France}, publisher = {Soc. OSC}, address = {Saint Maur}, pages = {8 -- 9}, year = {2010}, language = {en} } @incollection{KollSchwarzboezlHenneckeetal.2009, author = {Koll, Gerritt and Schwarzb{\"o}zl, Peter and Hennecke, Klaus and Hoffschmidt, Bernhard and Hartz, Thomas}, title = {Solarthermisches Turmkraftwerk in J{\"u}lich}, series = {Erneuerbare Energien. Bd. 2 : Ersatzbrennstoffe, Biomasse und Biogas, Solar- und Windenergie / Karl J. Thom{\´e}-Kozmiensky [Hrsg.]}, booktitle = {Erneuerbare Energien. Bd. 2 : Ersatzbrennstoffe, Biomasse und Biogas, Solar- und Windenergie / Karl J. Thom{\´e}-Kozmiensky [Hrsg.]}, publisher = {Thom{\´e}-Kozmiensky Verlag}, address = {Neuruppin}, pages = {455 -- 460}, year = {2009}, language = {de} } @inproceedings{ZiolkoFrickeAnthrakidisetal.2011, author = {Ziolko, Christoph and Fricke, Barbara and Anthrakidis, Anette and Hoffschmidt, Bernhard and Dillig, Marius and Giese, Frank and Schwarzb{\"o}zl, Peter}, title = {{\"O}kobilanzielle Aspekte technologischer Entwicklungen des Solarturmkraftwerks}, series = {Forschung und Entwicklung f{\"u}r solarthermische Kraftwerke : 14. K{\"o}lner Sonnenkolloquium Mittwoch, 13. Juli 2011, im Auditorium des Campus J{\"u}lich der FH Aachen : Kurzfassungen der Vortr{\"a}ge und Poster}, booktitle = {Forschung und Entwicklung f{\"u}r solarthermische Kraftwerke : 14. K{\"o}lner Sonnenkolloquium Mittwoch, 13. Juli 2011, im Auditorium des Campus J{\"u}lich der FH Aachen : Kurzfassungen der Vortr{\"a}ge und Poster}, publisher = {DLR}, address = {K{\"o}ln}, pages = {2 S.}, year = {2011}, language = {de} } @inproceedings{AlexopoulosHoffschmidtRauetal.2009, author = {Alexopoulos, Spiros and Hoffschmidt, Bernhard and Rau, Christoph and Schwarzb{\"o}zl, Peter}, title = {Simulation results for a hybridization concept of a small solar tower power plant}, series = {SolarPACES 2009 : electricity, fuels and clean water powered by the sun ; 15 - 18 September 2009, Berlin, Germany ; the 15th SolarPACES conference ; proceedings}, booktitle = {SolarPACES 2009 : electricity, fuels and clean water powered by the sun ; 15 - 18 September 2009, Berlin, Germany ; the 15th SolarPACES conference ; proceedings}, publisher = {Deutsches Zentrum f. Luft- u. Raumfahrt}, address = {Stuttgart}, isbn = {9783000287558}, pages = {1 CD-ROM}, year = {2009}, language = {en} } @inproceedings{KollSchwarzboezlHenneckeetal.2009, author = {Koll, Gerrit and Schwarzb{\"o}zl, Peter and Hennecke, Klaus and Hartz, Thomas and Schmitz, Mark and Hoffschmidt, Bernhard}, title = {The Solar Tower J{\"u}lich - a research and demonstration plant for central receiver systems}, series = {SolarPACES 2009 : electricity, fuels and clean water powered by the sun ; 15 - 18 September 2009, Berlin, Germany ; the 15th SolarPACES conference ; proceedings}, booktitle = {SolarPACES 2009 : electricity, fuels and clean water powered by the sun ; 15 - 18 September 2009, Berlin, Germany ; the 15th SolarPACES conference ; proceedings}, publisher = {Deutsches Zentrum f. Luft- u. Raumfahrt}, address = {Stuttgart}, isbn = {9783000287558}, pages = {1 CD-ROM}, year = {2009}, language = {en} }