@inproceedings{BallmannRaatschenStaat1985, author = {Ballmann, J. and Raatschen, Hans-J{\"u}rgen and Staat, Manfred}, title = {High stress intensities in focussing zones of waves}, doi = {10.1016/B978-0-444-42520-1.50015-3}, year = {1985}, abstract = {The propagation of mechanical waves in plates of isotropic elastic material is investigated. After a short introduction to the understanding of focussing of stress waves in a plate with a curved boundary the method of characteristics is applied to a plate of hyperelastic material. Using this method the propagation of acceleration waves is discussed. Based on this a numerical difference scheme is developed for solving initial-boundary-value problems and applied to two examples: propagation of a point disturbance in a homogeneously finitely strained non-linear elastic plate and geometrical focussing in al linear elastic plate.}, subject = {Technische Mechanik}, language = {en} } @inproceedings{StaatBallmann1989, author = {Staat, Manfred and Ballmann, J.}, title = {Fundamental aspects of numerical methods for the propagation of multi-dimensional nonlinear waves in solids}, series = {Nonlinear hyperbolic equations : theory, computations methods, and applications ; proceedings of the 2nd International Conference on Nonlinear Hyperbolic Problems, Aachen}, booktitle = {Nonlinear hyperbolic equations : theory, computations methods, and applications ; proceedings of the 2nd International Conference on Nonlinear Hyperbolic Problems, Aachen}, pages = {574 -- 588}, year = {1989}, abstract = {The nonlinear scalar constitutive equations of gases lead to a change in sound speed from point to point as would be found in linear inhomogeneous (and time dependent) media. The nonlinear tensor constitutive equations of solids introduce the additional local effect of solution dependent anisotropy. The speed of a wave passing through a point changes with propagation direction and its rays are inclined to the front. It is an open question whether the widely used operator splitting techniques achieve a dimensional splitting with physically reasonable results for these multi-dimensional problems. May be this is the main reason why the theoretical and numerical investigations of multi-dimensional wave propagation in nonlinear solids are so far behind gas dynamics. We hope to promote the subject a little by a discussion of some fundamental aspects of the solution of the equations of nonlinear elastodynamics. We use methods of characteristics because they only integrate mathematically exact equations which have a direct physical interpretation.}, subject = {Nichtlineare Welle}, language = {en} } @inproceedings{StaatHeitzer1997, author = {Staat, Manfred and Heitzer, Michael}, title = {Limit and shakedown analysis for plastic design}, year = {1997}, abstract = {Limit and shakedown theorems are exact theories of classical plasticity for the direct computation of safety factors or of the load carrying capacity under constant and varying loads. Simple versions of limit and shakedown analysis are the basis of all design codes for pressure vessels and pipings. Using Finite Element Methods more realistic modeling can be used for a more rational design. The methods can be extended to yield optimum plastic design. In this paper we present a first implementation in FE of limit and shakedown analyses for perfectly plastic material. Limit and shakedown analyses are done of a pipe-junction and a interaction diagram is calculated. The results are in good correspondence with the analytic solution we give in the appendix.}, subject = {Einspielen }, language = {en} } @inproceedings{BurgazziFioriniDeMagistrisetal.1998, author = {Burgazzi, L. and Fiorini, F. and De Magistris, W. (u.a.) and Lensa, W. von and Staat, Manfred and Altes, J.}, title = {Reliability Assessment of Passive Safety Systems}, series = {Proceedings of the 6th International Conference on Nuclear Engineering : ICONE : May 10 - 14, 1998, San Diego, Calif.}, booktitle = {Proceedings of the 6th International Conference on Nuclear Engineering : ICONE : May 10 - 14, 1998, San Diego, Calif.}, publisher = {American Society of Mechanical Engineers}, address = {New York}, year = {1998}, language = {en} } @inproceedings{Mertens2000, author = {Mertens, Josef}, title = {Laminar leading edges: manufacturing, contamination, and operational aspects - results from the German RaWid programme}, year = {2000}, abstract = {RaWid was the German national technology programme on transonic aerodynamics and supporting technologies, lasting from 1995 to 1998. One of the main topics was laminar wing development. Besides aerodynamic design work, many operational aspects were investigated. A manufacturing concept was developed to be applied to operational laminar wings and empennages. It was built in a large scale manufacturing demonstrator with the aerodynamic shape of a 1,5 m section of the A320 fin nose. Tolerances in shape and roughness fulfilled all requirements. The construction can easily be adapted to varying stiffness and strength requirements. Weight and manufacturing costs are comparable to common nose designs. The mock-up to be designed in ALTTA is based on this manufacturing principle. Another critical point is contamination of suction surfaces. Several tests were performed to investigate perforated titanium suction surfaces at realistic operational conditions: - a one year flight test with a suction plate in the stagnation area of the Airbus "Beluga" - a one year test of several suction plates in a ground test near the airport - a one year test of a working suction ground test installation at all weather conditions. No critical results were found. There is no long term suction degradation visible. Icing conditions and ground de-icing fluids used on airports did not pose severe problems. Some problems detected require only respection of weak design constraints.}, subject = {Laminare Str{\"o}mung}, language = {en} } @inproceedings{HeitzerStaat2000, author = {Heitzer, M. and Staat, Manfred}, title = {Direct FEM approach to design-by-analysis of pressurized components}, year = {2000}, abstract = {Abstracts of the ACHEMA 2000 - International Meeting on Chemical Engineering, Environmental Protection and Biotechnology, May 22 - 27, 2000. Frankfurt am Main. Achema 2000 : special edition / Linde. [Ed.: Linde AG. Red.: Volker R. Leski]. - Wiesbaden : Linde AG, 2000. - 56 p. : Ill., . - pp: 79 - 81}, subject = {Finite-Elemente-Methode}, language = {en} } @inproceedings{ZischankKernFrentzeletal.2000, author = {Zischank, Wolfgang J. and Kern, Alexander and Frentzel, Ralf and Heidler, Fridolin and Seevers, M.}, title = {Assessment of the lightning transient coupling to control cables interconnecting structures in large industrial facilities and power plants}, year = {2000}, abstract = {Large industrial facilities and power plants often require a huge number fo information and control cables between the differnet structures. These I\&C-cables can be routed in reinforced concrete cable ducts or in isolated buried cable runs. KTA 2206 is the German lightning protection standard for nuclear power plants. During the last several years considerable effort has been made to revise this standard. Despite the well established principles and design guidelines for the construction of the lightning protection system, this standard puts special emphasis on the coupling of transient overvoltages to I\&C-cables.}, language = {en} } @inproceedings{StaatHeitzer2000, author = {Staat, Manfred and Heitzer, Michael}, title = {Direct static FEM approach to limit and shakedown analysis}, year = {2000}, abstract = {Safety and reliability of structures may be assessed indirectly by stress distributions. Limit and shakedown theorems are simplified but exact methods of plasticity that provide safety factors directly in the loading space. These theorems may be used for a direct definition of the limit state function for failure by plastic collapse or by inadaptation. In a FEM formulation the limit state function is obtained from a nonlinear optimization problem. This direct approach reduces considerably the necessary knowledge of uncertain technological input data, the computing time, and the numerical error. Moreover, the direct way leads to highly effective and precise reliability analyses. The theorems are implemented into a general purpose FEM program in a way capable of large-scale analysis.}, subject = {Einspielen }, language = {en} } @inproceedings{KernKrichelMueller2001, author = {Kern, Alexander and Krichel, Frank and M{\"u}ller, Klaus-Peter}, title = {Lightning protection design of a renewable energy hybrid-system without power mains connection}, year = {2001}, abstract = {In the year 2000 a direct lightning strike to the hybridsystem without power mains connection VATALI on the Greek island Crete results in the destruction and damage of some mechanical and electrical components. The hybrid-system VATALI was not lightning protected at that time. The hardware damage costs are approx. 60,000 €. The exposed site of the hybrid-system on top of a mountain was and still is the reason for a high risk of lightning strikes. Also in the future further lightning strikes have to be taken into consideration. In the paper a fundamental lightning protection design concept for renewable energy hybrid-systems without power mains connection and protection measures against direct strikes and overvoltages are shown in detail. The design concept was realized exemplarily for the hybrid-system VATALI. The hardware costs for the protection measures were about 15,000 €. About 50\% of the costs are due to protection measures against direct strikes, 50\% are due to overvoltage protection. Future extensions, new installations, or modifications have to be included into the lightning protection design concept of the hybrid-system.}, language = {en} } @inproceedings{KraftMeyerNagl2002, author = {Kraft, Bodo and Meyer, Oliver and Nagl, Manfred}, title = {Graph technology support for conceptual design in civil engineering}, isbn = {3-18-318004-9}, year = {2002}, abstract = {In: Advances in intelligent computing in engineering : proceedings of the 9.International EG-ICE Workshop ; Darmstadt, (01 - 03 August) 2002 / Martina Schnellenbach-Held ... (eds.) . - D{\"u}sseldorf: VDI-Verl., 2002 .- Fortschritt-Berichte VDI, Reihe 4, Bauingenieurwesen ; 180 ; S. 1-35 The paper describes a novel way to support conceptual design in civil engineering. The designer uses semantical tools guaranteeing certain internal structures of the design result but also the fulfillment of various constraints. Two different approaches and corresponding tools are discussed: (a) Visually specified tools with automatic code generation to determine a design structure as well as fixing various constraints a design has to obey. These tools are also valuable for design knowledge specialist. (b) Extensions of existing CAD tools to provide semantical knowledge to be used by an architect. It is sketched how these different tools can be combined in the future. The main part of the paper discusses the concepts and realization of two prototypes following the two above approaches. The paper especially discusses that specific graphs and the specification of their structure are useful for both tool realization projects.}, subject = {CAD}, language = {en} } @inproceedings{StaatHeitzer2002, author = {Staat, Manfred and Heitzer, Michael}, title = {The restricted influence of kinematic hardening on shakedown loads}, year = {2002}, abstract = {Structural design analyses are conducted with the aim of verifying the exclusion of ratcheting. To this end it is important to make a clear distinction between the shakedown range and the ratcheting range. In cyclic plasticity more sophisticated hardening models have been suggested in order to model the strain evolution observed in ratcheting experiments. The hardening models used in shakedown analysis are comparatively simple. It is shown that shakedown analysis can make quite stable predictions of admissible load ranges despite the simplicity of the underlying hardening models. A linear and a nonlinear kinematic hardening model of two-surface plasticity are compared in material shakedown analysis. Both give identical or similar shakedown ranges. Structural shakedown analyses show that the loading may have a more pronounced effect than the hardening model.}, subject = {Biomedizinische Technik}, language = {en} } @inproceedings{DarvenizaFlisowskiKernetal.2002, author = {Darveniza, M. and Flisowski, Z. and Kern, Alexander and Landers, E.-U. and LoPiparo, G. and Mazzetti, C. and Rousseau, A. and Sherlock, J.}, title = {Application problems of the probabilistic approach to the assessment of risk for structures and services}, year = {2002}, abstract = {The paper deals with the development of the probabilistic approach to the assessment of risk due to lightning. Sources of damage, types of damage and types of loss are defined and, accordingly, the procedure for risk analysis and the way of assessment of different risk components is proposed. The way to evaluate the influence of different protection measures (lightning protection system; shielding of structure, cables and equipment; routing of internal wiring; surge protective device) in reducing such probabilities is considered. The paper has been prepared within the framework of the activity of IEC TC81-WG9/CLC TC81-WG4 directed to prepare the draft IEC 62305-2 Risk Management, in cooperation with the Secretary of IEC/CLC TC81.}, language = {en} } @inproceedings{KernKrichel2002, author = {Kern, Alexander and Krichel, Frank}, title = {Considerations about the lightning protection system of mains independent renewable energy hybrid-systems - practical experiences}, year = {2002}, abstract = {In the paper a lightning protection design concept for renewable energy hybrid-systems without power mains connection is described. Based on a risk analysis protection measures against direct strikes and overvoltages are shown in an overview. The design concept is realized exemplarily for the hybrid-system VATALI on the Greek island Crete. VATALI, not lightning protected at that time, was a victim of a lightning strike in the year 2000 causing destructions and damages of some mechanical and electrical components with costs of approx. 60.000 €. The hardware costs for the protection measures were about 15.000 €: about 50\% of the costs are due to protection measures against direct strikes, 50\% are due to overvoltage protection.}, language = {en} } @inproceedings{ZischankHeidlerKernetal.2002, author = {Zischank, Wolfgang J. and Heidler, Fridolin and Kern, Alexander and Metwally, I. A. and Wiesinger, J. and Seevers, M.}, title = {Laboratory simulation of direct lightning strokes to a modelled building - measurement of magnetic fields and induced voltages}, year = {2002}, abstract = {In IEC 61312-2 equations for the assessment of the magnetic fields inside structures due to a direct lightning strike are given. These equations are based on computer simulations for shields consisting of a single-layer steel grid of a given mesh width. Real constructions, however, contain at least two layers of reinforcement steel grids. The objective of this study was to experimentally determine the additional shielding effectiveness of a second reinforcement layer compared to a single-layer grid. To this end, simulated structures were set up in the high current laboratory. The structures consisted of cubic cages of 2 m side length with one or with two reinforcement grids, respectively. The structures were exposed to direct lightning currents representing the variety of anticipated lightning current waveforms. The magnetic fields and their derivatives at several positions inside the structure as well as the voltage between "floor" and "roof" in the center were determined for different current injection points. From these data the improvement of the shielding caused by a second reinforcement layer is derived.}, language = {en} } @inproceedings{DielmannPeters2002, author = {Dielmann, Klaus-Peter and Peters, Bernhard}, title = {Micro Turbine Using Different Gases and Liquid Fuels}, year = {2002}, abstract = {Micro turbine using different gases and liquid fuels}, subject = {Gasturbine}, language = {en} } @inproceedings{ChudobaButenwegKuhlmann2002, author = {Chudoba, Rostislav and Butenweg, Christoph and Kuhlmann, Wolfram}, title = {Technical information system for collaborative material research}, series = {Sixth International Conference on Computational Structures Technology : [Prague, Czech Republic, 4 - 6 September 2002]}, booktitle = {Sixth International Conference on Computational Structures Technology : [Prague, Czech Republic, 4 - 6 September 2002]}, organization = {International Conference on Computational Structures Technology <6, 2002, Prag>}, pages = {1 -- 11}, year = {2002}, language = {en} } @inproceedings{KraftNagl2003, author = {Kraft, Bodo and Nagl, Manfred}, title = {Semantic tool support for conceptual design}, year = {2003}, abstract = {ITCE-2003 - 4th Joint Symposium on Information Technology in Civil Engineering ed Flood, I., Seite 1-12, ASCE (CD-ROM), Nashville, USA In this paper we discussed graph based tools to support architects during the conceptual design phase. Conceptual Design is defined before constructive design; the used concepts are more abstract. We develop two graph based approaches, a topdown using the graph rewriting system PROGRES and a more industrially oriented approach, where we extend the CAD system ArchiCAD. In both approaches, knowledge can be defined by a knowledge engineer, in the top-down approach in the domain model graph, in the bottom-up approach in the in an XML file. The defined knowledge is used to incrementally check the sketch and to inform the architect about violations of the defined knowledge. Our goal is to discover design error as soon as possible and to support the architect to design buildings with consideration of conceptual knowledge.}, subject = {CAD}, language = {en} } @inproceedings{DigelTemizArtmannArtmannetal.2003, author = {Digel, Ilya and Temiz Artmann, Ayseg{\"u}l and Artmann, Gerhard and Nojima, H.}, title = {Plasma cluster ions (PCI) influence on microbial cells viability : [abstract]}, year = {2003}, abstract = {Recently, SHARP corporation has developed the world's first "Plasma Cluster Ions (PCI)" air purification technology, which uses plasma discharge to generate cluster ions. The new plasma cluster device releases into the air positive and negative ions, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. A lot of phenomenological tests of the PCI air purification technology on microbial cells have been conducted. And, in most cases, it has been shown that PCI demonstrate strongly pronounced killing effect. Although, the particular mechanisms of PCI action are still not evident. We studied variations in resistance to PCI among gram-positive airborne microorganisms, as well as some dose-dependent, spatial, cultural and biochemical properties of PCI action in respect of Staphylococcus spp, Enterococcus spp, Micrococcus spp.}, subject = {Clusterion}, language = {en} } @inproceedings{DigelTemizArtmannNojimaetal.2003, author = {Digel, Ilya and Temiz Artmann, Ayseg{\"u}l and Nojima, H. and Artmann, Gerhard}, title = {Effects of plasma generated ions on bacteria : [poster]}, year = {2003}, abstract = {Summary and Conclusions PCIs were clearly effective in terms of their antibacterial effects with the strains tested. This efficacy increased with the time the bacteries were exposed to PCIs. The bactericidal action has proved to be irreversible. PCIs were significantly less effective in shadowed areas. PCI exposure caused multiple protein damages as observed in SDS PAGE studies. There was no single but multiple molecular mechanism causing the bacterial death.}, subject = {Clusterion}, language = {en} } @inproceedings{DigelTemizArtmannNojimaetal.2003, author = {Digel, Ilya and Temiz Artmann, Ayseg{\"u}l and Nojima, H. and Artmann, Gerhard}, title = {Some peculiarities of application of cluster ions generated by plasma in respect of indoor air purification :[abstract]}, year = {2003}, abstract = {Recently, the SHARP Corporation, Japan, has developed the world's first "Plasma Cluster Ions (PCI)" air purification technology using plasma discharge to generate cluster ions. The new plasma cluster device releases positive and negative ions into the air, which are able to decompose and deactivate harmful airborne substances by chemical reactions. Because cluster ions consist of positive and negative ions that normally exist in the natural world, they are completely harmless and safe to humans. The amount of ozone generated by cluster ions is less than 0.01 ppm, which is significantly less than the 0.05-ppm standard for industrial operations and consumer electronics. This amount, thus, has no harming effects whatsoever on the human body. But particular properties and chemical processes in PCI treatment are still under study. It has been shown that PCI in most cases show strongly pronounced irreversible killing effects in respect of airborne microflora due to free-radical induced reactions and can be considered as a potent technology to disinfect both home, medical and industrial appliances.}, subject = {Clusterion}, language = {en} }