@inproceedings{KraftNagl2003, author = {Kraft, Bodo and Nagl, Manfred}, title = {Semantic tool support for conceptual design}, year = {2003}, abstract = {ITCE-2003 - 4th Joint Symposium on Information Technology in Civil Engineering ed Flood, I., Seite 1-12, ASCE (CD-ROM), Nashville, USA In this paper we discussed graph based tools to support architects during the conceptual design phase. Conceptual Design is defined before constructive design; the used concepts are more abstract. We develop two graph based approaches, a topdown using the graph rewriting system PROGRES and a more industrially oriented approach, where we extend the CAD system ArchiCAD. In both approaches, knowledge can be defined by a knowledge engineer, in the top-down approach in the domain model graph, in the bottom-up approach in the in an XML file. The defined knowledge is used to incrementally check the sketch and to inform the architect about violations of the defined knowledge. Our goal is to discover design error as soon as possible and to support the architect to design buildings with consideration of conceptual knowledge.}, subject = {CAD}, language = {en} } @inproceedings{KraftMeyerNagl2002, author = {Kraft, Bodo and Meyer, Oliver and Nagl, Manfred}, title = {Graph technology support for conceptual design in civil engineering}, isbn = {3-18-318004-9}, year = {2002}, abstract = {In: Advances in intelligent computing in engineering : proceedings of the 9.International EG-ICE Workshop ; Darmstadt, (01 - 03 August) 2002 / Martina Schnellenbach-Held ... (eds.) . - D{\"u}sseldorf: VDI-Verl., 2002 .- Fortschritt-Berichte VDI, Reihe 4, Bauingenieurwesen ; 180 ; S. 1-35 The paper describes a novel way to support conceptual design in civil engineering. The designer uses semantical tools guaranteeing certain internal structures of the design result but also the fulfillment of various constraints. Two different approaches and corresponding tools are discussed: (a) Visually specified tools with automatic code generation to determine a design structure as well as fixing various constraints a design has to obey. These tools are also valuable for design knowledge specialist. (b) Extensions of existing CAD tools to provide semantical knowledge to be used by an architect. It is sketched how these different tools can be combined in the future. The main part of the paper discusses the concepts and realization of two prototypes following the two above approaches. The paper especially discusses that specific graphs and the specification of their structure are useful for both tool realization projects.}, subject = {CAD}, language = {en} } @inproceedings{Kraft2004, author = {Kraft, Bodo}, title = {Conceptual design tools for civil engineering}, year = {2004}, abstract = {Applications of Graph Transformations with Industrial Relevance Lecture Notes in Computer Science, 2004, Volume 3062/2004, 434-439, DOI: http://dx.doi.org/10.1007/978-3-540-25959-6_33 This paper gives a brief overview of the tools we have developed to support conceptual design in civil engineering. Based on the UPGRADE framework, two applications, one for the knowledge engineer and another for architects allow to store domain specific knowledge and to use this knowledge during conceptual design. Consistency analyses check the design against the defined knowledge and inform the architect if rules are violated.}, subject = {CAD}, language = {en} } @inproceedings{KoplinSiemonsOcenValentinetal.2006, author = {Koplin, Tobias J. and Siemons, Maike and Oc{\´e}n-Val{\´e}ntin, C{\´e}sar and Sanders, Daniel and Simon, Ulrich}, title = {Workflow for high throughput screening of gas sensing materials}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1407}, year = {2006}, abstract = {The workflow of a high throughput screening setup for the rapid identification of new and improved sensor materials is presented. The polyol method was applied to prepare nanoparticular metal oxides as base materials, which were functionalised by surface doping. Using multi-electrode substrates and high throughput impedance spectroscopy (HT-IS) a wide range of materials could be screened in a short time. Applying HT-IS in search of new selective gas sensing materials a NO2-tolerant NO sensing material with reduced sensitivities towards other test gases was identified based on iridium doped zinc oxide. Analogous behaviour was observed for iridium doped indium oxide.}, subject = {Biosensor}, language = {en} } @inproceedings{Kniprath2009, author = {Kniprath, Ludwig}, title = {Einsatz von OpenSource-Software f{\"u}r geografische Informationssysteme am Beispiel des WVER}, year = {2009}, abstract = {Dipl.-Ing Ludwig Kniprath , Wasserverband Eifel-Rur, D{\"u}ren. 6 S. (S. 18-23). Beitrag zum 2. Aachener Softwaretag in der Wasserwirtschaft <2, 2009, Aachen> 1. Einleitung 2. Datenbest{\"a}nde 3. GIS-Konzept des WVER 4. Umsetzung 5. Quellenangaben, Links}, subject = {Geoinformationssystem}, language = {de} } @inproceedings{Kloecker2006, author = {Kl{\"o}cker, Alexander}, title = {Das Leitungsbauunternehmen - unternehmerische Strategie als Zukunftssicherung}, year = {2006}, abstract = {In: Alfha.net / Sektion Bauingenieurwesen: 1. [Erster] Erfahrungsaustausch : Absolventen des Fachbereichs Bauingenieurwesens berichten. 13. Oktober 2006. S. 21-22 Zusammenfassung des Vortrags}, subject = {Leitungsbau}, language = {de} } @inproceedings{Klocke2012, author = {Klocke, Martina}, title = {Projektmodul im Bachelorstudiengang Maschinenbau und Mechatronik}, series = {VDI-Workshop Projektorientiertes und problem-basiertes Lernen (PBL) in der Ingenieurausbildung}, booktitle = {VDI-Workshop Projektorientiertes und problem-basiertes Lernen (PBL) in der Ingenieurausbildung}, pages = {1 -- 25}, year = {2012}, language = {de} } @inproceedings{KirchhofKraft2011, author = {Kirchhof, Michael and Kraft, Bodo}, title = {Dogmatisches „Entweder agil oder klassisch" im Projektmanagement hat ausgedient - die richtige Mischung macht's}, series = {Projekt-Sternstunden : strahlende Erfolge durch Kompetenz}, booktitle = {Projekt-Sternstunden : strahlende Erfolge durch Kompetenz}, publisher = {GPM}, address = {N{\"u}rnberg}, isbn = {978-3-924841-60-7}, pages = {414 -- 425}, year = {2011}, language = {de} } @inproceedings{KirchhofKraft2004, author = {Kirchhof, M. and Kraft, Bodo}, title = {UML-based modeling of architectural knowledge and design}, year = {2004}, abstract = {IASSE-2004 - 13th International Conference on Intelligent and Adaptive Systems and Software Engineering eds. W. Dosch, N. Debnath, pp. 245-250, ISCA, Cary, NC, 1-3 July 2004, Nice, France We introduce a UML-based model for conceptual design support in civil engineering. Therefore, we identify required extensions to standard UML. Class diagrams are used for elaborating building typespecific knowledge: Object diagrams, implicitly contained in the architect's sketch, are validated against the defined knowledge. To enable the use of industrial, domain-specific tools, we provide an integrated conceptual design extension. The developed tool support is based on graph rewriting. With our approach architects are enabled to deal with semantic objects during early design phase, assisted by incremental consistency checks.}, subject = {UML}, language = {en} } @inproceedings{KernNeskakisMueller2001, author = {Kern, Alexander and Neskakis, Apostolos and M{\"u}ller, Klaus-Peter}, title = {Blitzschutzkonzept f{\"u}r eine netz-autarke Hybridanlage am Beispiel der Anlage VATALI auf Kreta}, year = {2001}, abstract = {Netz-autarke Anlagen bestehen {\"u}blicherweise aus einer oder mehreren Photovoltaik- (PV-) Anlagen, ggf. auch Solarthermie- (ST-) Anlagen und einem oder mehreren kleineren Windgeneratoren (sie werden deshalb auch als Hybridanlagen bezeichnet) und werden vor allem in Gegenden mit sehr schlechter {\"o}ffentlicher Energieversorgung eingesetzt, d.h. insbesondere in rel. d{\"u}nn bewohnten Gebieten und in Entwicklungsl{\"a}ndern. Der Blitzschutz von netz-autarken Hybridanlagen ist ein bislang noch vergleichsweise unzureichend bearbeitetes Fachgebiet. F{\"u}r große Windenergie-Anlagen (WEA) wurde in den letzten Jahren eine Zahl von FuE-Projekten durchgef{\"u}hrt, zum Großteil finanziert durch die {\"o}ffentliche Hand, zum kleineren Teil auch durch die Industrie, d.h. die WEAHersteller. Dabei wurden bestehende Defizite im Design der WEA festgestellt und Maßnahmen vorgeschlagen, die vor den mechanischen Zerst{\"o}rungen insbesondere des Rotors und vor den St{\"o}rungen und Zerst{\"o}rungen an den elektrischen / elektronischen Systemen der WEA weitgehend Schutz bieten [1, 2, 3]. Der Stand-der- Normung ist im Entwurf DIN VDE 0127 Teil 24 „Blitzschutz f{\"u}r Windenergieanlagen" (dt. {\"U}bersetzung des internationalen Drafts IEC 61400-24 „Wind turbine generator systems; Part 24: Lightning Protection") dokumentiert [4]. Die Maßnahmen sind allerdings insbesondere f{\"u}r gr{\"o}ßere WEA vorgesehen; im Falle kleinerer WEA lassen sie sich nur bedingt umsetzen. Trotzdem sind auch kleinere WEA rel. stark blitzeinschlaggef{\"a}hrdet, wenn sie auf einer Bergkuppe o.{\"a}. platziert werden. F{\"u}r solche kleinere WEA, wie sie bei Hybridanlagen {\"u}blicherweise Verwendung finden, m{\"u}ssen die Blitzschutzmaßnahmen aus der DIN VDE 0127 Teil 24 angepasst werden. F{\"u}r PV- und ST-Anlagen ist eine entsprechende Blitzschutz-Norm noch nicht in Sicht. Hier ist vor allem der Schutz gegen direkte Blitzeinschl{\"a}ge in die Anlage bzw. die Geb{\"a}ude noch nicht ausreichend beachtet. Blitzfangeinrichtungen sind oft nicht vorgesehen. In aller Regel hat man dabei bisher eine Ausf{\"u}hrungsform des Blitzschutzes realisiert, die prim{\"a}r einen Ferneinschlag ber{\"u}cksichtigt und die dabei entstehenden induzierten, rel. energieschwachen {\"U}berspannungen durch schw{\"a}chere Schutzelemente wie R{\"u}ckstromdioden, Bypassdioden und zum Teil thermisch {\"u}berwachte Varistoren begrenzt [5, 6, 7]. Diese Schutzelemente k{\"o}nnen allerdings bei Naheinschl{\"a}gen bzw. Direkteinschl{\"a}gen {\"u}berlastet und damit zerst{\"o}rt werden. Dar{\"u}ber hinaus k{\"o}nnen Nahoder Direkteinschl{\"a}ge auch zur Schw{\"a}chung der elektrischen Festigkeit der PVModulisolierung f{\"u}hren. Die Folge davon sind lokale extreme W{\"a}rmeentwicklungen, die sogar ein Schmelzen von Glas (sekund{\"a}rer Langzeiteffekt) hervorrufen k{\"o}nnten. Bei einem Blitzeinschlag in die netz-autarke Hybridanlage VATALI auf Kreta im Jahre 2000 wurden sowohl einige mechanische wie auch elektrische Komponenten der Anlage zerst{\"o}rt bzw. zum Teil schwer besch{\"a}digt. Die Anlage VATALI besaß zum Zeitpunkt des Blitzeinschlags keinen wirksamen Blitzschutz. Der Gesamtschaden der Hardware belief sich auf ca. 60.000,- EURO. Die exponierte Stellung der Anlage auf einer Bergspitze stellte und stellt nach wie vor ein enormes Blitzeinschlag-Risiko dar, so dass auch zuk{\"u}nftig mit Blitzeinwirkungen gerechnet werden muss. Die Anlage wurde inspiziert, blitzschutz-technische Erfordernisse definiert und daraus Ert{\"u}chtigungsmaßnahmen abgeleitet, die mit {\"u}berschaubarem Aufwand realisierbar sind.}, language = {de} } @inproceedings{KernMeppelink2001, author = {Kern, Alexander and Meppelink, Jan}, title = {Neue M{\"o}glichkeiten elektrischer Anschl{\"u}sse an die Bewehrung und Untersuchung der Wirkung von Blitzstr{\"o}men in bewehrtem Beton}, year = {2001}, abstract = {Im Rahmen eines modernen Blitzschutzsystems f{\"u}r Stahlbeton-Bauten bietet es sich an, die Betonbewehrung zu benutzen: - Sie kann die Funktionen der Ableitungseinrichtungen und des Blitzschutz- Potentialausgleichs bei einem klassischen Geb{\"a}ude-Blitzschutz {\"u}bernehmen [1]; - Sie kann, ggf. bei entsprechender Erg{\"a}nzung, als ein geschlossener K{\"a}fig ausgebildet werden und damit eine deutliche Reduzierung der Belastung elektrischer / elektronischer Systeme durch blitzinduzierte elektromagnetische Felder erbringen (LEMP-Schutz [2]). Die Nutzung der Bewehrung ist dabei grunds{\"a}tzlich gleichermaßen bei Neubauten wie auch bei Ert{\"u}chtigungen m{\"o}glich und sinnvoll. So stellt die Nutzung der Bewehrung beispielsweise im Bereich von Großkraftwerken eine wesentliche Ert{\"u}chtigungsmaßnahme f{\"u}r den Blitzschutz elektrischer und elektronischer Einrichtungen dar: - Einerseits wird der Blitzschutz-Potentialausgleich durch den Anschluss metallener Einrichtungen wie Elektronik-Schr{\"a}nke, Kabeltrag-Konstruktionen, Rohrleitungen, etc. an die Bewehrung deutlich verbessert. - Andererseits kann bei gr{\"o}ßeren Geb{\"a}uden die elektromagnetische Schirmwirkung durch die elektrische {\"U}berbr{\"u}ckung von vorhandenen Dehnfugen bei Stahlbetonbauten optimiert werden. Diese Dehnfugen sind teilweise nur unzureichend {\"u}berbr{\"u}ckt, so dass bei Blitzeinschlag in das betreffende oder ein benachbartes Geb{\"a}ude an Kabelstrecken, die {\"u}ber die Dehnfuge hinwegf{\"u}hren, rel. hohe Spannungen induziert werden k{\"o}nnen [2, 3]. Die sich um das gesamte Geb{\"a}ude herumziehende oder zwischen zwei Geb{\"a}uden befindliche Dehnfuge muss deshalb im Abstand von maximal einigen Metern {\"u}berbr{\"u}ckt werden. Im Falle von Blitzschutz-Ert{\"u}chtigungen in vorhandenen Geb{\"a}uden wird bisher an jeder geplanten Anschlussstelle die Bewehrung großfl{\"a}chig (\&\#8709; wenige 10 cm) freigelegt, dort ein elektrischer Anschluss zu dem Bewehrungsstab hergestellt, z.B. mittels eines Erdungsfestpunkts, und dann die Betonoberfl{\"a}che wieder geschlossen. Je nach prognostizierter Strombelastung wird teilweise versucht, den {\"u}ber den Anschluss fließenden Strom bereits auf mehrere Bewehrungsst{\"a}be zu verteilen. Dazu sind entweder die kreuzenden St{\"a}be zu verschweißen oder es sind direkt Anschl{\"u}sse an zwei Bewehrungsst{\"a}be herzustellen. All dieses bedeutet einen hohen Aufwand bei der Freilegung der Bewehrung und auch wieder bei der Schließung der entstandenen Betonl{\"o}cher. Es soll deshalb hier untersucht werden, ob es beispielsweise zum Zwecke des Blitzschutz-Potentialausgleichs und auch zur {\"U}berbr{\"u}ckung von Dehnfugen ausreichend ist, den Anschluss an die Bewehrung nach einfachen Verfahren nur jeweils an einen Bewehrungsstab herzustellen. Damit w{\"u}rde der finanzielle und administrative Aufwand an Betonarbeiten deutlich reduziert. Die hier dargestellten Verfahren sind dabei insbesondere f{\"u}r den Einsatz bei Blitzschutz-Ert{\"u}chtigungen in bestehenden Geb{\"a}uden vorgesehen. Abschließend sollen deshalb die M{\"o}glichkeiten zur Pr{\"u}fung korrekter Anschl{\"u}sse, die Grenzen der Verfahren sowie auch die Grenzen der Anwendbarkeit bei Neuanlagen diskutiert werden.}, language = {de} } @inproceedings{KernKraemer2003, author = {Kern, Alexander and Kr{\"a}mer, Heinz-Josef}, title = {Blitzschutzkonzept f{\"u}r eine bauliche Anlage mit Stahlkonstruktion und metallenen W{\"a}nden}, year = {2003}, abstract = {Bauliche Anlagen mit Stahlkonstruktionen (bzw. auch Stahlbetonskelett- Konstruktionen) und metallenen W{\"a}nden sind bereits in sehr großer Zahl errichtet. Dazu geh{\"o}ren kleinere bis gr{\"o}ßere Lagerhallen ebenso wie Einkaufszentren. Sie zeichnen sich durch große Flexibilit{\"a}t, einfache Planung, kurze Bauzeit und rel. geringe Kosten aus. Auch in der nahen Zukunft ist deshalb mit Planung und Errichtung weiterer solcher baulicher Anlagen zu rechnen. Abh{\"a}ngig von der Nutzung der Hallen sind auch mehr oder weniger umfangreiche elektrische und elektronische Systeme vorhanden, die wichtige Funktionen sicherstellen m{\"u}ssen. Der Blitzschutz f{\"u}r diese baulichen Anlagen sollte sich also nicht nur im „klassischen" Geb{\"a}ude-Blitzschutz nach DIN V 0185-3 VDE V 0185 Teil 3 [1] ersch{\"o}pfen; ein Erg{\"a}nzung hin zu einem sinnvollen Grundschutz der elektrischen und elektronischen Systeme nach DIN V 0185-4 VDE V 0185 Teil 4 [2] ist anzuraten. Im folgenden Beitrag wird ein Konzept vorgestellt, mit dem ein hochwertiger Blitzschutz sowohl der baulichen Anlage und der darin befindlichen Personen, als auch der elektrischen und elektronischen Systeme verwirklicht werden kann. Insbesondere bei großfl{\"a}chigen Hallen stellen sich dabei besondere Anforderungen. Das Konzept und die zugeh{\"o}rigen blitzschutz-technischen Maßnahmen k{\"o}nnen drei Hauptbereichen zugeordnet werden: - {\"A}ußerer Blitzschutz; - Innerer Blitzschutz; - weitergehende besondere Maßnahmen. Das Konzept sowie die Maßnahmen werden allgemein beschrieben und teilweise anhand einer ausgef{\"u}hrten Anlage mit Fotos beispielhaft dokumentiert.}, language = {de} } @inproceedings{KernKrichelMueller2001, author = {Kern, Alexander and Krichel, Frank and M{\"u}ller, Klaus-Peter}, title = {Lightning protection design of a renewable energy hybrid-system without power mains connection}, year = {2001}, abstract = {In the year 2000 a direct lightning strike to the hybridsystem without power mains connection VATALI on the Greek island Crete results in the destruction and damage of some mechanical and electrical components. The hybrid-system VATALI was not lightning protected at that time. The hardware damage costs are approx. 60,000 €. The exposed site of the hybrid-system on top of a mountain was and still is the reason for a high risk of lightning strikes. Also in the future further lightning strikes have to be taken into consideration. In the paper a fundamental lightning protection design concept for renewable energy hybrid-systems without power mains connection and protection measures against direct strikes and overvoltages are shown in detail. The design concept was realized exemplarily for the hybrid-system VATALI. The hardware costs for the protection measures were about 15,000 €. About 50\% of the costs are due to protection measures against direct strikes, 50\% are due to overvoltage protection. Future extensions, new installations, or modifications have to be included into the lightning protection design concept of the hybrid-system.}, language = {en} } @inproceedings{KernKrichel2002, author = {Kern, Alexander and Krichel, Frank}, title = {Considerations about the lightning protection system of mains independent renewable energy hybrid-systems - practical experiences}, year = {2002}, abstract = {In the paper a lightning protection design concept for renewable energy hybrid-systems without power mains connection is described. Based on a risk analysis protection measures against direct strikes and overvoltages are shown in an overview. The design concept is realized exemplarily for the hybrid-system VATALI on the Greek island Crete. VATALI, not lightning protected at that time, was a victim of a lightning strike in the year 2000 causing destructions and damages of some mechanical and electrical components with costs of approx. 60.000 €. The hardware costs for the protection measures were about 15.000 €: about 50\% of the costs are due to protection measures against direct strikes, 50\% are due to overvoltage protection.}, language = {en} } @inproceedings{KernHeidlerSeeversetal.2004, author = {Kern, Alexander and Heidler, Fridolin and Seevers, M. and Zischank, Wolfgang J.}, title = {Magnetic Fields and Induced Voltages in case of a Direct Strike - Comparison of Results obtained from Measurements at a Scaled Building to those of IEC 62305-4}, isbn = {0304-3886}, year = {2004}, abstract = {In the paper the results obtained from experiments at a modelled reinforced building in case of a direct lightning strike are compared with calculations. The comparison includes peak values of the magnetic field Hmax, its derivative (dH/dt)max and of induced voltages umax in typical cable routings. The experiments are performed at a 1:6 scaled building and the results are extrapolated using the similarity relations theory. The calculations are based on the approximate formulae given in IEC 62305-4 and have to be supplemented by a rough estimation of the additional shielding effect of a second reinforcement layer. The comparison shows, that the measured peak values of the magnetic field and its derivative are mostly lower than the calculated. The induced voltages are in good agreement. Hence, calculations of the induced voltages based on IEC 62305-4 are a good method for lightning protection studies of buildings, where the reinforcement is used as a grid-like electromagnetic shield.}, subject = {Blitz}, language = {en} } @inproceedings{KernDikta2009, author = {Kern, Alexander and Dikta, Gerhard}, title = {Probability of damage of electrical and electronic systems due to indirect lightning flashes - investigation of data from German insurance companies}, year = {2009}, abstract = {In the presented paper data collected from the field related to damage statistics of electrical and electronic apparatus in household are reported and investigated. These damages (total number approx. 74000 cases), registered by five German insurance companies in 2005 and 2006, were adviced by customers as caused by lightning overvoltages. With the use of stochastical methods it is possible, to reasses the collected data and to distinguish between cases, which are with high probability caused by lightning overvoltages, and those, which are not. If there was an indication for a direct strike, this case was excluded, so the focus was only on indirect lightning flashes, i.e. only flashes to ground near the structure and flashes to or nearby an incoming service line were investigated. The data from the field contain the location of damaged apparatus (residence of the policy holder) and the distances of the nearest cloud-to-ground stroke to the location of the damage registered by the German lightning location network BLIDS at the date of damage. The statistical data along with some complementary numerical simulations allow to verify the correspondence of the Standards rules used for IEC 62305-2 with the field data and to define some correction needs. The results could lead to a better understanding whether a damage reported to an insurance company is really caused by indirect lightning, or not.}, subject = {Blitzschutz}, language = {en} } @inproceedings{KernBeierlZischank2009, author = {Kern, Alexander and Beierl, Ottmar and Zischank, Wolfgang}, title = {Calculation of the separation distance according to IEC 62305-3: 2006-10 - Remarks for the application and simplified methods}, year = {2009}, abstract = {[Paper of the X International Symposium on Lightning Protection 9th - 13th November, 2009 - Curitiba, Brazil. 6 pages] The international standard IEC 62305-3, published in 2006, requires as an integral part of the lightning protection system (LPS) the consideration of a separation distance between the conductors of the LPS and metal and electrical installations inside the structure to be protected. IEC 62305-3 gives two different methods for this calculation: a standard, simplified approach and a more detailed approach, which differ especially regarding the treatment of the current sharing effect on the LPS conductors. Hence, different results for the separation distance are possible, leading to some discrepancies in the use of the standard. The standard approach defined in the main part (Clause 6.3) and in Annex C of the standard in some cases may lead to a severe oversizing of the required separation distance. The detailed approach described in Annex E naturally gives more correct results. However, a calculation of the current sharing amongst all parts of the air-termination and downconductor network is necessary, in many cases requiring the use of network analysis programs. In this paper simplified methods for the assessment of the current sharing are presented, which are easy to use as well as sufficiently adequate.}, subject = {Blitzschutz}, language = {de} } @inproceedings{Kern2003, author = {Kern, Alexander}, title = {Absch{\"a}tzung des Blitzschadensrisikos f{\"u}r bauliche Anlagen - Die neue Bestimmung DIN V VDE V 0185 Teil 2 : 2002 - Allgemeines, Absch{\"a}tzungsverfahren, Berechnungsbeispiele}, year = {2003}, abstract = {Ein vorausschauendes Risikomanagement beinhaltet, Risiken f{\"u}r das Unternehmen zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent, welche Risiken sinnvollerweise {\"u}ber Versicherungen abgedeckt werden sollten. Beim Versicherungsmanagement ist jedoch zu bedenken, dass zur Erreichung bestimmter Ziele Versicherungen nicht immer geeignet sind (z.B. Erhaltung der Lieferf{\"a}higkeit). Eintrittswahrscheinlichkeiten bestimmter Risiken lassen sich durch Versicherungen nicht ver{\"a}ndern. Bei Unternehmen, die mit umfangreichen elektronischen Einrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Ber{\"u}cksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nicht-Verf{\"u}gbarkeit der elektronischen Einrichtungen und damit der Produktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardware-Schaden an der betroffenen Anlage oft bei weitem {\"u}bersteigt. Im Blitzschutz gewinnt innovatives Denken in Schadensrisiken langsam an Bedeutung. Risikoanalysen haben die Objektivierung und Quantifizierung der Gef{\"a}hrdung von baulichen Anlagen und ihrer Inhalte durch direkte und indirekte Blitzeinschl{\"a}ge zum Ziel. Seinen Niederschlag hat dieses neue Denken in der neuen deutschen Vornorm DIN V 0185-2 VDE V 0185 Teil 2 [1] gefunden. Die hier vorgegebene Risikoanalyse gew{\"a}hrleistet, dass ein f{\"u}r alle Beteiligten nachvollziehbares Blitzschutz-Konzept erstellt werden kann, das technisch und wirtschaftlich optimiert ist, d.h. bei m{\"o}glichst geringem Aufwand den notwendigen Schutz gew{\"a}hrleisten kann. Die sich aus der Risikoanalyse ergebenden Schutzmaßnahmen sind dann in den weiteren Normenteilen der neuen Reihe VDE V 0185 [2, 3] detailliert beschrieben.}, language = {de} } @inproceedings{Kern2002, author = {Kern, Alexander}, title = {Risikomanagement : Absch{\"a}tzung des Schadensrisikos f{\"u}r bauliche Anlagen - Die neue Vornorm DIN V VDE V 0185 Teil 2 : 2002}, year = {2002}, abstract = {Alle Unternehmen sind vielf{\"a}ltigen Risiken ausgesetzt, die Finanz- und Betriebsbereiche einschließlich Dienstleistungen betreffen k{\"o}nnen. Die Firmen m{\"u}ssen {\"u}blicherweise Risiken eingehen, um im Wettbewerb bestehen zu k{\"o}nnen. Entscheidend ist, dass man sich {\"u}ber die Risiken bewusst ist, diese einsch{\"a}tzen und kontrollieren kann. Falsche Einsch{\"a}tzungen, Vers{\"a}umnisse und Fehlentscheidungen k{\"o}nnen empfindliche finanzielle Sch{\"a}den bis hin zum Totalverlust nach sich ziehen. Ein effektives Risikomanagement ist heute als wichtiger Sicherheitsfaktor anzusehen und sollte zur strategischen Unternehmensf{\"u}hrung geh{\"o}ren. Ein vorausschauendes Risikomanagement beinhaltet, Risiken f{\"u}r das Unternehmen zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent, welche Risiken sinnvollerweise {\"u}ber Versicherungen abgedeckt werden sollten. Beim Versicherungsmanagement ist jedoch zu bedenken, dass zur Erreichung bestimmter Ziele Versicherungen nicht geeignet sind (z.B. Erhaltung der Lieferf{\"a}higkeit). Eintrittswahrscheinlichkeiten bestimmter Risiken lassen sich durch Versicherungen nicht ver{\"a}ndern. Bei Unternehmen, die mit umfangreichen elektronischen Einrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Ber{\"u}cksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nicht-Verf{\"u}gbarkeit der elektronischen Einrichtungen und damit der Produktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardware-Schaden an der betroffenen Anlage oft bei weitem {\"u}bersteigt. Im Blitzschutz gewinnt innovatives Denken in Schadensrisiken langsam an Bedeutung. Risikoanalysen haben die Objektivierung und Quantifizierung der Gef{\"a}hrdung von baulichen Anlagen und ihrer Inhalte durch direkte und indirekte Blitzeinschl{\"a}ge zum Ziel. Seinen Niederschlag hat dieses neue Denken in der neuen deutschen Norm DIN V 0185-2 VDE V 0185 Teil 2 gefunden. Die hier vorgegebene Risikoanalyse gew{\"a}hrleistet, dass ein f{\"u}r alle Beteiligten nachvollziehbares Blitzschutz-Konzept erstellt werden kann, das technisch und wirtschaftlich optimiert ist, d.h. bei m{\"o}glichst geringem Aufwand den notwendigen Schutz gew{\"a}hrleisten kann. Die sich aus der Risikoanalyse ergebenden Schutzmaßnahmen sind dann in den weiteren Normenteilen der neuen Reihe VDE V 0185 detailliert beschrieben.}, language = {de} } @inproceedings{Kern2003, author = {Kern, Alexander}, title = {Risikomanagement nach DIN V 0185-2 VDE V 0185 Teil 2: 2002-11 - Einige Beispiele und erste Erfahrungen}, year = {2003}, abstract = {Die neue Vornorm VDE V 0185 Teil 2 „Risikomanagement: Absch{\"a}tzung des Schadensrisikos f{\"u}r bauliche Anlagen" [1] ist seit November 2002 g{\"u}ltig. Sie erm{\"o}glicht nicht nur die Ermittlung der Schutzklasse eines Blitzschutzsystems, sondern auch die Untersuchung zur Notwendigkeit anderer Schutzmaßnahmen gegen Blitzeinwirkungen ({\"U}berspannungsschutzger{\"a}te in Unterverteilern und/oder an Endger{\"a}ten, Schirmung des Geb{\"a}udes und/oder interner R{\"a}ume, Potentialsteuerung, Brandmelde- und Feuerl{\"o}scheinrichtungen, etc.) nach objektiven Kriterien und damit in einer f{\"u}r alle Beteiligten grunds{\"a}tzlich nachvollziehbaren Art und Weise. Dass eine solche Analyse rel. komplex sein muss und der intensiven Besch{\"a}ftigung bedarf, ist deshalb nicht verwunderlich. Die Komplexit{\"a}t des Verfahrens sollte allerdings nicht dazu f{\"u}hren, die Vornorm als Ganzes abzulehnen. Die Vornorm beruht auf dem Stand der Diskussion im internationalen Normengremium IEC TC81 WG9 Ende des Jahres 2000. Integriert wurden einige nationale Besonderheiten, die aus Sicht des zust{\"a}ndigen Normenkomitees DKE K251 erforderlich erschienen. In Deutschland konnten und k{\"o}nnen nun erste breite Erfahrungen in der Anwendung dieser Risikoanalyse gesammelt werden; in anderen L{\"a}ndern ist dies noch nicht m{\"o}glich. Diese Erfahrungen k{\"o}nnen dann, nach Diskussion im nationalen Rahmen, in die internationale Normenarbeit eingebracht werden. Im folgenden Beitrag sollen einige, seit Erscheinen der Vornorm oft wiederkehrende Fragen dargestellt und L{\"o}sungsvorschl{\"a}ge vorgestellt werden. Dabei wird auch auf die Tendenzen im internationalen Normengremium IEC TC81 WG9 eingegangen, d.h. auf den aktuellen Entwurf zur IEC 62305-2 [3]. Die L{\"o}sungsvorschl{\"a}ge werden begr{\"u}ndet, sind allerdings weitestgehend subjektive Meinung des Autors. F{\"u}r {\"u}bliche bauliche Anlagen ist die Anwendung der Vornorm rel. einfach m{\"o}glich. Auch f{\"u}r spezielle F{\"a}lle k{\"o}nnen die darin festgelegten Verfahren herangezogen werden; allerdings sind dann einige weiterf{\"u}hrende {\"U}berlegungen notwendig, die der Planer von Blitzschutzsystemen durchf{\"u}hren muss. Anhand zweier Beispiele soll die Anwendung der VDE V 0185 Teil 2 auf solche speziellen F{\"a}lle dargestellt werden.}, language = {de} } @inproceedings{KatzWillner2006, author = {Katz, Eugenii and Willner, Itamar}, title = {Magneto-controlled quantized electron transfer to surface-confined redox units and metal nanoparticles}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1528}, year = {2006}, abstract = {Hydrophobic magnetic nanoparticles (NPs) consisting of undecanoate-capped magnetite (Fe3O4, average diameter ca. 5 nm) are used to control quantized electron transfer to surface-confined redox units and metal NPs. A two-phase system consisting of an aqueous electrolyte solution and a toluene phase that includes the suspended undecanoatecapped magnetic NPs is used to control the interfacial properties of the electrode surface. The attracted magnetic NPs form a hydrophobic layer on the electrode surface resulting in the change of the mechanisms of the surface-confined electrochemical processes. A quinone-monolayer modified Au electrode demonstrates an aqueous-type of the electrochemical process (2e-+2H+ redox mechanism) for the quinone units in the absence of the hydrophobic magnetic NPs, while the attraction of the magnetic NPs to the surface results in the stepwise single-electron transfer mechanism characteristic of a dry nonaqueous medium. Also, the attraction of the hydrophobic magnetic NPs to the Au electrode surface modified with Au NPs (ca. 1.4 nm) yields a microenvironment with a low dielectric constant that results in the single-electron quantum charging of the Au NPs.}, subject = {Biosensor}, language = {en} } @inproceedings{KallweitSchleupenDahmannetal.2016, author = {Kallweit, Stephan and Schleupen, Josef and Dahmann, Peter and Bagheri, Mohsen and Engemann, Heiko}, title = {Entwicklung eines Kletterroboters zur Diagnose und Instandsetzung von Windenergieanlagen (SMART)}, series = {Automatisierung im Fokus von Industrie 4.0 : Tagungsband AALE 2016 ; 13. Fachkonferenz, L{\"u}beck}, booktitle = {Automatisierung im Fokus von Industrie 4.0 : Tagungsband AALE 2016 ; 13. Fachkonferenz, L{\"u}beck}, publisher = {DIV Deutscher Industrieverlag GmbH}, address = {M{\"u}nchen}, isbn = {978-3-8356-7312-0}, pages = {207 -- 212}, year = {2016}, language = {de} } @inproceedings{KallweitFerreinScholletal.2014, author = {Kallweit, Stephan and Ferrein, Alexander and Scholl, Ingrid and Reichert, Walter}, title = {Mobile Autonome Systeme in der Lehre, am Beispiel der ROS Summer School}, series = {Tagungsband AALE 2014 : das Forum f{\"u}r Fachleute der Automatisierungstechnik aus Hochschulen und Wirtschaft ; 11. Fachkonferenz, Regensburg ; [11. Konferenz f{\"u}r Angewandte Automatisierungstechnik in Lehre und Entwicklung / Ostbayerische Technische Hochschule Regensburg; VFAALE, Verein der Freunde und F{\"o}rderer der Angewandten Automatisierungstechnik]}, booktitle = {Tagungsband AALE 2014 : das Forum f{\"u}r Fachleute der Automatisierungstechnik aus Hochschulen und Wirtschaft ; 11. Fachkonferenz, Regensburg ; [11. Konferenz f{\"u}r Angewandte Automatisierungstechnik in Lehre und Entwicklung / Ostbayerische Technische Hochschule Regensburg; VFAALE, Verein der Freunde und F{\"o}rderer der Angewandten Automatisierungstechnik]}, publisher = {Dt. Industrieverl.}, address = {M{\"u}nchen}, isbn = {978-3-8356-7142-3}, pages = {157 -- 163}, year = {2014}, language = {de} } @inproceedings{Kallweit2012, author = {Kallweit, Stephan}, title = {Pandaboard, TurtleBot, Kinect und Co. : Low-Cost Hardware im Lehreinsatz f{\"u}r die mobile Robotik.}, year = {2012}, abstract = {Mit freundlicher Genehmigung der Autoren und des Oldenbourg Industrieverlags https://www.oldenbourg-industrieverlag.de/de/9783835633223-33223 erschienen als Beitrag im Tagungsband zur AALE-Tagung 2012. 9. Fachkonferenz 4.-5. Mai 2012, Aachen, Fachhochschule. ISBN 9783835633223 S 8-1 S. 229-238 Original-Abstract des Autors: "Die mobile Robotik wird durch den Einsatz von Low-Cost Hardware einem breiten Publikum zug{\"a}nglich. Bis vor kurzem basierte eine erschwingliche Hardware meist auf Mikrocontrollern mit den entsprechenden Leistungseinschr{\"a}nkungen z.B. im Bereich der Bildverarbeitung. Die Wahrnehmung einer 3D-Umgebung und somit die M{\"o}glichkeit zur autonomen Navigation wurde mit relativ kostenintensiver Hardware, z.B. Stereo-Vision-Systemen und Laserscannern gel{\"o}st. Die zur Auswertung der Sensorik notwendige Rechenleistung stand - entweder aufgrund des Stromverbrauchs oder der Performance meist f{\"u}r mobile Plattformen (lokal) - nicht zur Verf{\"u}gung. Durch Einsatz von leistungsf{\"a}higen Prozessoren aus dem Bereich der Mobilger{\"a}te (Smartphones, Tablets) und neuartigen Sensoren des Consumer-Bereichs, wie der Kinect, k{\"o}nnen mobile Roboter kosteng{\"u}nstig f{\"u}r den Einsatz in der Lehre aufgebaut werden.}, subject = {Robotik}, language = {de} } @inproceedings{JungStaatMueller2014, author = {Jung, Alexander and Staat, Manfred and M{\"u}ller, Wolfram}, title = {Optimization of the flight style in ski jumping}, series = {11th World Congress on Computational Mechanics (WCCM XI) ; 5th European Conference on Computational Mechanics (ECCM V) ; 6th European Conference on Computational Fluid Dynamics (ECFD VI) ; July 20 - 25, 2014, Barcelona}, booktitle = {11th World Congress on Computational Mechanics (WCCM XI) ; 5th European Conference on Computational Mechanics (ECCM V) ; 6th European Conference on Computational Fluid Dynamics (ECFD VI) ; July 20 - 25, 2014, Barcelona}, editor = {Onate, E.}, organization = {World Congress on Computational Mechanics <11, 2014, Barcelona>}, pages = {799 -- 810}, year = {2014}, language = {en} } @inproceedings{JungFrotscherStaat2018, author = {Jung, Alexander and Frotscher, Ralf and Staat, Manfred}, title = {Electromechanical model of hiPSC-derived ventricular cardiomyocytes cocultured with fibroblasts}, series = {6th European Conference on Computational Mechanics (ECCM 6), 7th European Conference on Computational Fluid Dynamics (ECFD 7), 11-15 June 2018, Glasgow, UK}, booktitle = {6th European Conference on Computational Mechanics (ECCM 6), 7th European Conference on Computational Fluid Dynamics (ECFD 7), 11-15 June 2018, Glasgow, UK}, pages = {11 Seiten}, year = {2018}, abstract = {The CellDrum provides an experimental setup to study the mechanical effects of fibroblasts co-cultured with hiPSC-derived ventricular cardiomyocytes. Multi-scale computational models based on the Finite Element Method are developed. Coupled electrical cardiomyocyte-fibroblast models (cell level) are embedded into reaction-diffusion equations (tissue level) which compute the propagation of the action potential in the cardiac tissue. Electromechanical coupling is realised by an excitation-contraction model (cell level) and the active stress arising during contraction is added to the passive stress in the force balance, which determines the tissue displacement (tissue level). Tissue parameters in the model can be identified experimentally to the specific sample.}, language = {en} } @inproceedings{Jacobs2007, author = {Jacobs, Stephan}, title = {Verwendung von Netzwerkmustern in der Telekommunikationsindustrie : [Vortragsfolien]}, series = {Test Patterns - Intelligente Wiederverwendung von Testware : Software-QS-Tag 2007 ; 08. November 2007, N{\"u}rnberg}, booktitle = {Test Patterns - Intelligente Wiederverwendung von Testware : Software-QS-Tag 2007 ; 08. November 2007, N{\"u}rnberg}, pages = {49 S. : zahlr. Ill. und graph. Darst.}, year = {2007}, abstract = {"[...] Der erste Teil des Vortags konzentriert sich auf die bei Ericsson gemachten Erfahrungen. Welche Muster wurden identifiziert, f{\"u}r welche Tests wurden sie eingesetzt. Wie werden diese Muster verwendet, wie werden sie beschrieben und spezifiziert. Und schließlich, wie entsteht eine Art Standardisierung, in der das Wissen {\"u}ber diese Muster als Organisationswissen zur Verf{\"u}gung steht. Im zweiten Teil des Vortrags werden die bei Ericsson gemachten Erfahrungen verallgemeinert. Die bei Ericsson verwendeten Muster werden auf allgemeine Strukturen {\"u}bertragen (z.B. Client-Server). Es wird gezeigt, wie die Zuordnung von Testverfahren auf Netzwerkmuster auch in anderen Dom{\"a}nen verwendet wird und welche Vorteile sich damit erzielen lassen." Quelle: http://www.qs-tag.de/fileadmin/software-qs-tag/public/2007/abstract_jacobs.shtml}, language = {de} } @inproceedings{HueningHeuermannWache2018, author = {H{\"u}ning, Felix and Heuermann, Holger and Wache, Franz-Josef}, title = {Wireless CAN}, series = {Tagungsband AALE 2018 : das Forum f{\"u}r Fachleute der Automatisierungstechnik aus Hochschulen und Wirtschaft ; 15. Fachkonferenz, Regensburg ; [15. Konferenz f{\"u}r Angewandte Automatisierungstechnik in Lehre und Entwicklung / TH K{\"o}ln; VFAALE, Verein der Freunde und F{\"o}rderer der Angewandten Automatisierungstechnik]}, booktitle = {Tagungsband AALE 2018 : das Forum f{\"u}r Fachleute der Automatisierungstechnik aus Hochschulen und Wirtschaft ; 15. Fachkonferenz, Regensburg ; [15. Konferenz f{\"u}r Angewandte Automatisierungstechnik in Lehre und Entwicklung / TH K{\"o}ln; VFAALE, Verein der Freunde und F{\"o}rderer der Angewandten Automatisierungstechnik]}, publisher = {VDE Verlag}, pages = {135 -- 144}, year = {2018}, abstract = {Das vorgestellte System zu Wireless CAN bietet die M{\"o}glichkeit, CAN kabellos zu {\"u}bertragen. Beide vorgestellten und entwickelten Konzepte funktionieren korrekt und erm{\"o}glichen den Auf-bau von kabellosen CAN Schnittstellen. Durch den kleinen Aufbau kann diese Technologie auch f{\"u}r eingebettete Systeme verwendet werden. Zudem bietet dieser Ansatz die M{\"o}glichkeit, durch die Entwicklung von geeigneten ICs die Gr{\"o}ße des Systems bis auf Bauteilgr{\"o}ße zu reduzieren, um eine noch bessere Integration in eingebettete Systeme zu erm{\"o}glichen. Dadurch wird die Technologie attraktiv f{\"u}r Einsatzgebiete, wo die oben aufgelisteten Vorteile zum Tragen kommen k{\"o}nnen. Diese Einsatzgebiete k{\"o}nnen sowohl im Automobil als auch im Industriebereich liegen.}, language = {de} } @inproceedings{HuberRauStreblowetal.2014, author = {Huber, Max and Rau, Sebastian and Streblow, Rita and Wollert, J{\"o}rg and M{\"u}ller, Dirk}, title = {L{\"u}ftungskan{\"a}le als Funkstrecke}, series = {Jahreskolloquium Kommunikation in der Automation (KommA 2014) : Lemgo, 18.11.2014 / J{\"u}rgen Jasperneite ... (Hrsg.)}, booktitle = {Jahreskolloquium Kommunikation in der Automation (KommA 2014) : Lemgo, 18.11.2014 / J{\"u}rgen Jasperneite ... (Hrsg.)}, organization = {Jahreskolloquium Kommunikation in der Automation <5, 2014, Lemgo>}, isbn = {978-3-9814062-4-5}, pages = {1 -- 8}, year = {2014}, language = {de} } @inproceedings{HuberDemny2009, author = {Huber, Brigitte and Demny, Gerd}, title = {Mischwassereinleitungen in Gew{\"a}sser nach BWK Merkblatt M3 - Vorteile des detaillierten Nachweises}, year = {2009}, abstract = {Dipl.-Ing. Brigitte Huber und Dr.-Ing. Gerd Demny - Wasserverband Eifel Rur, D{\"u}ren. 16 Seiten ( S. 59-74). Beitrag zum 2. Aachener Softwaretag in der Wasserwirtschaft <2, 2009, Aachen> Zusammenfassung [der Autoren] F{\"u}r das st{\"a}dtisch gepr{\"a}gte Einzugsgebiet des Broicher Baches sind ein vereinfachter und ein detaillierter Nachweis nach BWK-M3 durchgef{\"u}hrt worden. Dabei zeigt sich, dass die Methodik des vereinfachten Nachweises nicht geeignet ist, um eine realit{\"a}tsnahe Abbildung der einleitungsgepr{\"a}gten Abfl{\"u}sse des Gew{\"a}ssers zu erhalten. Dies ist insbesondere auf die Vernachl{\"a}ssigung von Wellentranslation und -retention im Gerinne zur{\"u}ckzuf{\"u}hren. Die dadurch entstehende Fehleinsch{\"a}tzung der Abflussverh{\"a}ltnisse versperrt den Blick auf eine situationsgerechte Maßnahmenplanung. Der mit Hilfe eines NA-Modells gef{\"u}hrte detaillierte Nachweis ist zwar in der Erstellung aufw{\"a}ndiger, zeichnet aber ein reales Bild der Abflusserh{\"o}hung durch Einleitungen. Mit Hilfe des Modells k{\"o}nnen die wesentlichen Einfl{\"u}sse schnell lokalisiert und zielf{\"u}hrende Maßnahmenvarianten identifiziert werden. In dem hier vorgestellten Beispiel des Broicher Baches k{\"o}nnen die urspr{\"u}nglich identifizierten acht Maßnahmen auf eine reduziert werden. Das Gesamtvolumen der erforderlichen R{\"u}ckhaltungen wird um die H{\"a}lfte verringert. Der Vergleich beider Nachweismethoden legt nach Ansicht der Autoren nahe, den vereinfachten Nachweis h{\"o}chstens f{\"u}r eine erste Einsch{\"a}tzung des Maßnahmenbedarfs anzuwenden. Die Maßnahmenidentifikation und -dimensionierung sollte grunds{\"a}tzlich mit der detaillierten Nachweismethode durchgef{\"u}hrt werden, die auf einem entsprechenden NA-Modell basiert. Dies gilt insbesondere f{\"u}r Gew{\"a}sserstrecken, deren Abfluss durch mehrere, hintereinander liegende Einleitungsstellen gepr{\"a}gt ist.}, subject = {Fließgew{\"a}sser}, language = {de} } @inproceedings{Hoffmann2009, author = {Hoffmann, Marc}, title = {Analyse und Visualisierung von zeitbezogenen Daten im Raum - Beispiele aus Hydrologie und Wasserwirtschaft}, year = {2009}, abstract = {Dipl.-Ing Marc Hoffmann - Kisters AG, Aachen. 13 S. (S. 32-44). Beitrag zum 2. Aachener Softwaretag in der Wasserwirtschaft <2, 2009, Aachen> Zahlreiche Folien, Grafiken und Praxisbeispiele}, subject = {Visualisierung}, language = {de} } @inproceedings{Hoevel2009, author = {Hoevel, Hartmut}, title = {Die Zukunft der Erft - Perspektiven f{\"u}r ein erheblich ver{\"a}ndertes Gew{\"a}sser}, year = {2009}, abstract = {Dipl.-Ing. Hartmut Hoevel - Erftverband, Bergheim. 3 Seiten (S. 75-77). Beitrag zum 2. Aachener Softwaretag in der Wasserwirtschaft <2, 2009, Aachen> Die Erft ist ein linker Nebenfluss des Rheins. Der Fluss ist durch eingeleitetes S{\"u}mpfungswasser aus dem rheinischen Braunkohletagebau hinsichtlich der Wassermenge und der Temperatur stark belastet. Die vorgestellten {\"U}berlegungen betreffen die Fragen: 1. Wie soll die Erft im Jahr 2045, also nach dem voraussichtlichen Ende der Tagebauaktivit{\"a}ten im Rheinischen Braunkohlerevier und damit einhergehender Beenigung der S{\"u}mpfungswassereinleitung, aussehen? 2. Wie schnell und auf welche Weise soll die Umgestaltung der Erft vonstatten gehen?}, subject = {Fließgew{\"a}sser}, language = {de} } @inproceedings{Hoepner2008, author = {Hoepner, Gert}, title = {Jurorenstatement - Junioren zeigen sich aggressiv}, organization = {DDV Deutscher Dialogmarketing Verband e. V.}, year = {2008}, abstract = {Statement zu den Einreichung des DDP 2008}, subject = {Deutscher Direktmarketing-Verband}, language = {de} } @inproceedings{Himmerich2006, author = {Himmerich, J{\"o}rg}, title = {Pipeline Integrity Management System - Probabilistische Bewertung von Bauwerken am Beispiel von Hochdruckleitungen}, year = {2006}, abstract = {In: Alfha.net / Sektion Bauingenieurwesen: 1. [Erster] Erfahrungsaustausch : Absolventen des Fachbereichs Bauingenieurwesens berichten. 13. Oktober 2006. S. 21-22. Zusammenfassung des Vortrags.}, subject = {Hochdruckleitung}, language = {de} } @inproceedings{Herzog2007, author = {Herzog, Rudolf}, title = {Das Oberfl{\"a}chenabflussmodell von Keser und die Grenzwertmethode : Die Abflussbildung im Vergleich.}, year = {2007}, abstract = {Dipl.-Ing. Rudolf Herzog , Rehm Software Berg / Ravensburg. 9 S. (S. 94-102). Beitrag zum 1. Aachener Softwaretag in der Wasserwirtschaft a1, 2007, Aachen>. Zusammenfassung [des Autors] Die grundlegenden Ans{\"a}tze der beiden Modelle sind {\"a}hnlich. Der haupts{\"a}chliche Unterschied liegt darin, dass die Grenzwertmethode die Angabe einer Bodenart erfordert, die ihrerseits wieder Probleme verursachen kann. Es kann nicht davon ausgegangen werden, dass die Bodenarten homogen anliegen. Die ersatzweise Vorgabe einer f{\"u}r alle Einzugsgebiete einheitlichen Bodenart hilft da nicht wirklich weiter. Es stellt sich vielmehr die Frage, ob der zus{\"a}tzliche Aufwand eine signifikante Verbesserung des Ereignisses zur Folge hat. Der Vorteil der Grenzwertmethode liegt auf der Hand: Die Parameterwahl erm{\"o}glicht eine flexible Steuerung des Modells, in die Abflussbildung kann differenziert eingegriffen werden. Das NA-Geschehen kann weitgehend kalibriert werden. Es ist allerdings auch zu bedenken, dass die Flexibilit{\"a}t des Modells risikobehaftet ist - die Abflussbildung kann nach Belieben beeinflusst werden. Fazit: Flexibel in der Anwendung, bei NA-Messung empfehlenswert. Im Allgemeinen geringere Abflussmengen als Keser. Die Blackbox von Keser ist zwar nicht steuerbar, entzieht sich damit aber auch Wissensdefiziten und Manipulationseinfl{\"u}ssen. {\"U}ber Parameter und deren Auswirkungen muss nicht spekuliert werden. Wenn mehrere Personen mit dem Modell von Keser arbeiten, ergeben sich im Gegensatz zur Grenzwertmethode zwangsweise dieselben Ergebnisse - gleiche geometrische Oberfl{\"a}chendaten vorausgesetzt. Außerdem kommt Keser ohne die Bodenart aus. Fazit: Bei BFG >20\%, einfache Handhabung, geringer Aufwand. Gegen{\"u}ber der Grenzwertmethode (mittlere Verh{\"a}ltnisse) jedoch etwas h{\"o}here Abfl{\"u}sse. Das Programmpaket HYKAS der Fa. Rehm Software erm{\"o}glicht u.a. den Nachweis von Kanalnetzen und bietet in diesem Zusammenhang beide Modellans{\"a}tze zur Auswahl an. Der Programmanwender kann damit eine am Datenbestand bzw. an den Vorgaben des Auftraggebers ausgerichtete Modellauswahl treffen. Die realit{\"a}tsnahe Ermittlung der Oberfl{\"a}chenabfl{\"u}sse ist kompliziert. Weitere Unwegsamkeiten warten nach der Abflussbildung bei der Abflusskonzentration auf: Es ist z.B. die Festlegung der Fließl{\"a}nge auf der Oberfl{\"a}che erforderlich... Es ist noch ein weiter Weg bis zur Kl{\"a}ranlage.}, subject = {Entw{\"a}sserung }, language = {de} } @inproceedings{HellmannsHesse2007, author = {Hellmanns, Mark and Hesse, Joachim}, title = {Ger{\"a}uschminderung und Leichtbau in Leistungsgetrieben durch den Einsatz von Werkstoffverbunden}, series = {Hybride Maschinenkonzepte und intelligente Verfahren zur Fertigung von High-Tech-Produkten : Erfolgsbeispiele zur Standortsicherung in Hochlohnl{\"a}ndern : InnoNet Kolloquium am 7. und 8.11.2007, Technologiezentrum am Europaplatz Aachen}, booktitle = {Hybride Maschinenkonzepte und intelligente Verfahren zur Fertigung von High-Tech-Produkten : Erfolgsbeispiele zur Standortsicherung in Hochlohnl{\"a}ndern : InnoNet Kolloquium am 7. und 8.11.2007, Technologiezentrum am Europaplatz Aachen}, pages = {1 -- 46}, year = {2007}, language = {de} } @inproceedings{HeitzerStaat2000, author = {Heitzer, M. and Staat, Manfred}, title = {Direct FEM approach to design-by-analysis of pressurized components}, year = {2000}, abstract = {Abstracts of the ACHEMA 2000 - International Meeting on Chemical Engineering, Environmental Protection and Biotechnology, May 22 - 27, 2000. Frankfurt am Main. Achema 2000 : special edition / Linde. [Ed.: Linde AG. Red.: Volker R. Leski]. - Wiesbaden : Linde AG, 2000. - 56 p. : Ill., . - pp: 79 - 81}, subject = {Finite-Elemente-Methode}, language = {en} } @inproceedings{Heisterkamp2009, author = {Heisterkamp, Reinhold}, title = {Vom Desktop-GIS zur mobilen 3D-L{\"o}sung}, year = {2009}, abstract = {Dipl.-Ing. Reinhold Heisterkamp - GDS Geo Daten Service GmbH, Borken (Westf.). 8 S. (S. 24-31). Beitrag zum 2. Aachener Softwaretag in der Wasserwirtschaft <2, 2009, Aachen>. Einleitung Web-GIS Leistungsmerkmale von aktuellen Web-GIS Mobile GIS-L{\"o}sungen Dreidimensionale GIS-L{\"o}sungen}, subject = {Geoinformationssystem}, language = {de} } @inproceedings{HeerRedkowitzKraft2008, author = {Heer, Thomas and Redkowitz, Daniel and Kraft, Bodo}, title = {Tool Support for the Integration of Light-Weight Ontologies}, isbn = {978-3-642-00670-8}, year = {2008}, abstract = {Abstract of the authors: In many areas of computer science ontologies become more and more important. The use of ontologies for domain modeling often brings up the issue of ontology integration. The task of merging several ontologies, covering specific subdomains, into one united ontology has to be solved. Many approaches for ontology integration aim at automating the process of ontology alignment. However, a complete automation is not feasible, and user interaction is always required. Nevertheless, most ontology integration tools offer only very limited support for the interactive part of the integration process. In this paper, we present a novel approach for the interactive integration of ontologies. The result of the ontology integration is incrementally updated after each definition of a correspondence between ontology elements. The user is guided through the ontologies to be integrated. By restricting the possible user actions, the integrity of all defined correspondences is ensured by the tool we developed. We evaluated our tool by integrating different regulations concerning building design.}, subject = {Ontologie }, language = {de} } @inproceedings{Hecker2007, author = {Hecker, Dirk}, title = {Hochwasservorsorge f{\"u}r Abwasseranlagen (DWA-M103) und {\"o}ffentliche Einrichtungen}, year = {2007}, abstract = {Dipl.-Ing. Dirk Hecker von der Ingenieurgesellschaft Tuttahs \& Meyer in Aachen. Vortrag gehalten beim 1. Aachener Softwaretag in der Wasserwirtschaft <1, 2007, Aachen> 27 S. (S. 28-54) Zusammenfassung [des Autors]: Nach den spektakul{\"a}ren Hochwasserereignissen an Rhein, Elbe und Donau hat die Deutsche Vereinigung f{\"u}r Wasserwirtschaft, Abwasser und Abfall e. V. (DWA) einen Fachausschuss zur Erstellung eines Merkblattes M 103 „Hochwasserschutz f{\"u}r Abwasseranlagen" berufen. Das Merkblatt zeigt in den Kapiteln Konzeption, Planungsgrunds{\"a}tze und Hochwassermanagement eine strukturierte Vorgehensweise zur bestm{\"o}glichen Vorsorge zum Schutz der Abwasseranlagen im Hochwasserfall. Entsprechend den Forderungen des im Jahr 2005 verabschiedeten Gesetzes zur Verbesserung des vorbeugenden Hochwasserschutzes, floss in das Wasserhaushaltsgesetz unter anderem die allgemeine Verpflichtung jedes potentiell vom Hochwasser Betroffenen ein, geeignete Schutzmaßnahmen zur Schadensminimierung zu treffen. Hierbei werden speziell die Wasserversorgung und die Abwasserbeseitigung erw{\"a}hnt. Im DWA-M 103 wir detailliert dargestellt wie und mit welchem Aufwand die Abwasseranlagen zu {\"u}berpr{\"u}fen sind und wie hierzu ein Hochwasserschutzkonzept erstellt werden kann. Zus{\"a}tzlich werden Hinweise f{\"u}r die Planung von Abwasseranlagen in hochwassergef{\"a}hrdeten Bereichen gegeben, die den st{\"o}rungsfreien Betrieb im Hochwasserfall gew{\"a}hrleisten sollen. Schlussendlich werden das Hochwassermanagement und der Betrieb dargestellt und hier wichtige Anregungen gegeben im Ernstfall ausreichend vorbereitet zu sein. Das DWA-M 103 richtet sich in erster Linie an die Betreiber und Planer von Abwasseranlagen. Jedoch werden hier auch, gerade durch die Vielzahl von Checklisten, Kommunen Denkanst{\"o}ße und Anregungen f{\"u}r die Hochwasservorsorge/-schutz von {\"o}ffentlichen Geb{\"a}uden und Einrichtungen gegeben.}, subject = {Hochwasserschutz}, language = {de} } @inproceedings{HartungHillgaertnerSchmitzetal.2014, author = {Hartung, Frank and Hillg{\"a}rtner, Michael and Schmitz, G{\"u}nter and Schuba, Marko and Adolphs, Fabian and Hoffend, Jens and Theis, Jochen}, title = {IT-Sicherheit im Automobil}, series = {AmE 2014 : Automotive meets Electronics, Beitr{\"a}ge der 5. GMM-Fachtagung vom 18. bis 19. Februar 2014 in Dortmund. (GMM-Fachbericht ; 78)}, booktitle = {AmE 2014 : Automotive meets Electronics, Beitr{\"a}ge der 5. GMM-Fachtagung vom 18. bis 19. Februar 2014 in Dortmund. (GMM-Fachbericht ; 78)}, publisher = {VDE-Verl.}, address = {Berlin}, organization = {VDE/VDI-Gesellschaft Mikroelektronik, Mikrosystem- und Feinwerktechnik (GMM)}, isbn = {978-3-8007-3580-8}, pages = {CD-ROM}, year = {2014}, language = {de} } @inproceedings{GoettscheRoether2014, author = {G{\"o}ttsche, Joachim and R{\"o}ther, Sascha}, title = {Science College Overbach - Innovatives Bildungszentrum in J{\"u}lich-Barmen}, series = {18. Internationale Passivhaustagung, Aachen, April 2014}, booktitle = {18. Internationale Passivhaustagung, Aachen, April 2014}, pages = {6 Seiten}, year = {2014}, abstract = {Preprint der Autoren}, language = {de} } @inproceedings{GoettscheKornAmato2015, author = {G{\"o}ttsche, Joachim and Korn, Michael and Amato, Alexandre}, title = {The Passivhaus concept for the Arabian Peninsula - An energetic-economical evaluation considering the thermal comfort}, series = {QScience Proceedings: Vol 2015}, booktitle = {QScience Proceedings: Vol 2015}, doi = {10.5339/qproc.2015.qgbc.38}, pages = {8 Seiten}, year = {2015}, abstract = {The Passivhaus building standard is a concept developed for the realization of energy-efficient and economical buildings with a simultaneous high utilization comfort under European climate conditions. Major elements of the Passivhaus concept are a high thermal insulation of the external walls, the use of heat and/or solar shading glazing as well as an airtight building envelope in combination with energy-efficient technical building installations and heating or cooling generators, such as an efficient energy-recovery in the building air-conditioning. The objective of this research project is the inquiry to determine the parameters or constraints under which the Passivhaus concept can be implemented under the arid climate conditions in the Arabian Peninsula to achieve an energy-efficient and economical building with high utilization comfort. In cooperation between the Qatar Green Building Council (QGBC), Barwa Real Estate (BRE) and Kahramaa the first Passivhaus was constructed in Qatar and on the Arabian Peninsula in 2013. The Solar-Institut J{\"u}lich of Aachen University of Applied Science supports the Qatar Green Building Council with a dynamic building and equipment simulation of the Passivhaus and the neighbouring reference building. This includes simulation studies with different component configurations for the building envelope and different control strategies for heating or cooling systems as well as the air conditioning of buildings to find an energetic-economical optimum. Part of these analyses is the evaluation of the energy efficiency of the used energy recovery system in the Passivhaus air-conditioning and identification of possible energy-saving effects by the use of a bypass function integrated in the heat exchanger. In this way it is expected that on an annual basis the complete electricity demand of the building can be covered by the roof-integrated PV generator.}, language = {en} } @inproceedings{GroebelKowollikCrummenerletal.2009, author = {Groebel, Simone and Kowollik, Silvia and Crummenerl, Silvia and Sch{\"o}ning, Michael Josef}, title = {2. Graduiertentagung : 5. November 2009 / [Hrsg.: S. Groebel ; S. Kowollik ; S. Crummenerl ; M. J. Sch{\"o}ning]}, organization = {FH Aachen, University of Applied Sciences / Graduiertentagung <2, 2009>}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-3131}, year = {2009}, abstract = {Tagungsband der Graduiertentagung der FH Aachen, in dem Doktorandinnen und Doktoranden und ihre Forschungsbereiche vorgestellt werden}, subject = {Aachen / Fachhochschule Aachen ; Graduierter ; Promotionsstudium}, language = {de} } @inproceedings{GregorioFatigatiKallweit2015, author = {Gregorio, Fabrizio de and Fatigati, Giovanni and Kallweit, Stephan}, title = {Tiltrotor airframe flow field characterization by SPIV}, series = {11th International Symposium on Partivle Image Velocimetry - PIV15 , Santa Barbara, California, Sept 14-16, 2015}, booktitle = {11th International Symposium on Partivle Image Velocimetry - PIV15 , Santa Barbara, California, Sept 14-16, 2015}, pages = {15 S.}, year = {2015}, language = {en} } @inproceedings{Gobbele2006, author = {Gobbel{\´e}, Dirk}, title = {Planung der Umbaumaßnahme Hauptbahnhof Aachen}, year = {2006}, abstract = {In: Alfha.net / Sektion Bauingenieurwesen: 1. [Erster] Erfahrungsaustausch : Absolventen des Fachbereichs Bauingenieurwesens berichten. 13. Oktober 2006. S. 13-15. Bericht {\"u}ber die infrastrukturellen Maßnahmen zum Umbau des Hauptbahnhofs Aachen.}, subject = {Bauplanung}, language = {de} } @inproceedings{GellertNordaButenweg2008, author = {Gellert, Christoph and Norda, Hannah and Butenweg, Christoph}, title = {Nonlinear behaviour of masonry under cyclic loading}, series = {7th European Conference on Structural Dynamics, EURODYN 2008 : 7-9 July 2008, Southampton}, booktitle = {7th European Conference on Structural Dynamics, EURODYN 2008 : 7-9 July 2008, Southampton}, organization = {European Conference on Structural Dynamics, EURODYN <7, 2008, Southampton>}, pages = {1 -- 12}, year = {2008}, language = {en} } @inproceedings{GebhardtSchmidt2005, author = {Gebhardt, Andreas and Schmidt, Frank-Michael}, title = {Farbige Prototypen als Werkzeug f{\"u}r den Konstrukteur}, year = {2005}, abstract = {Physische Prototypen, also Anschauungs- und Funktionsmodelle nach den generativen oder Rapid Prototyping (RP) Verfahren haben sich in diesem Zusammenhang vor allem als Hilfsmittel zur effektiven Kommunikation und zur Evaluierung von Produkteigenschaften einen festen Platz in der Produktentstehung erworben. Die positiven Effekte der etablierten RP Verfahren sind unumstritten. Einfachere, schnellere und wirtschaftlichere Maschinen (Prototyper, Fabrikator), vor allem auch f{\"u}r die B{\"u}roumgebung, geben neue Impulse im Sinne der Optimierung der heutigen Verfahren. Eine neue Dimension verspricht die Option „Farbe" der bisher fast ausschließlich monochromen Modelle. Ist Farbe nur „nice to have" oder welchen Effekt haben farbige Modelle als Werkzeug von Konstrukteuren und Produktenwicklern? Welche Perspektiven bietet „Farbe" dar{\"u}ber hinaus?}, subject = {Prototyping}, language = {de} } @inproceedings{Gebhardt2006, author = {Gebhardt, Andreas}, title = {Technology Diffusion through a Multi-Level Technology Transfer Infrastructure. Contribution to the 1st. All Africa Technology Diffusion Conference Boksburg, South Africa June 12th - 14th 2006}, year = {2006}, abstract = {Table of contents 1. Introduction 2. Multi-level Technology Transfer Infrastructure 2.1 Level 1: University Education - Encourage the Idea of becoming an Entrepreneur 2.2 Level 2: Post Graduate Education - Improve your skills and focus it on a product family. 2.3 Level 3: Birth of a Company - Focus your skills on a product and a market segment. 2.4 Level 4: Ready to stand alone - Set up your own business 2.5 Level 5: Grow to be Strong - Develop your business 2.6 Level 6: Competitive and independent - Stay innovative. 3. Samples 3.1 Sample 1: Laser Processing and Consulting Centre, LBBZ 3.2 Sample 2: Prototyping Centre, CP 4. Funding - Waste money or even lost Money? 5. Conclusion}, subject = {Technologietransfer}, language = {en} } @inproceedings{FoersterStockMontanarietal.2006, author = {F{\"o}rster, Arnold and Stock, J{\"u}rgen and Montanari, Simone and Lepsa, Mihail Ion and L{\"u}th, Hans}, title = {Fabrication and characterisation of GaAs Gunn Diode Chips for applications at 77 GHz in automotive industry}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1462}, year = {2006}, abstract = {GaAs-based Gunn diodes with graded AlGaAs hot electron injector heterostructures have been developed under the special needs in automotive applications. The fabrication of the Gunn diode chips was based on total substrate removal and processing of integrated Au heat sinks. Especially, the thermal and RF behavior of the diodes have been analyzed by DC, impedance and S-parameter measurements. The electrical investigations have revealed the functionality of the hot electron injector. An optimized layer structure could fulfill the requirements in adaptive cruise control (ACC) systems at 77 GHz with typical output power between 50 and 90 mW.}, subject = {Biosensor}, language = {en} }