@article{NabilPetersonSchmidtetal.2010, author = {Nabil, F. and Peterson, Leif Arne and Schmidt, A. and Geerdes, D.}, title = {Die Holzkuppel des Neuen Palais in Potsdam}, series = {Bauingenieur}, volume = {85}, journal = {Bauingenieur}, number = {8}, publisher = {Springer-VDI-Verlag}, address = {D{\"u}sseldorf}, issn = {0005-6650}, pages = {324 -- 330}, year = {2010}, language = {de} } @article{LepkeLilliePetersonetal.2006, author = {Lepke, Dietrich and Lillie, Dirk and Peterson, Leif Arne and Hempe, Thomas}, title = {Liegedauer von Holzschwellen in Tunneln der Hamburger Hochbahn AG}, series = {EI - Der Eisenbahningenieur}, journal = {EI - Der Eisenbahningenieur}, number = {2}, publisher = {DVV Media Group}, address = {Hamburg}, issn = {0013-2810}, pages = {46 -- 50}, year = {2006}, abstract = {Die Hamburger Hochbahn AG ben{\"o}tigte im Rahmen der {\"U}berarbeitung einer langfristigen Instandhaltungs- und Erneuerungsstrategie f{\"u}r ihre U-Bahn-Infrastruktur eine belastbare Aussage {\"u}ber die Restlebensdauer der Holzschwellen im Tunnel. Aus diesem Grunde beauftragte sie das Institut f{\"u}r Verkehrswesen, Eisenbahnbau und -betrieb (IVE) der Universit{\"a}t Hannover mit der Erstellung eines entsprechenden Gutachtens. Das Ergebnis f{\"u}hrte zu der gesicherten Aussage einer erheblich l{\"a}ngeren Restlebensdauer der Tunnelschwellen gegen{\"u}ber den bisherigen, gesch{\"a}tzten Annahmen.}, language = {de} } @article{GrossTimmer1998, author = {Groß, Rolf Fritz and Timmer, H.}, title = {Energetische und betriebswirtschaftliche Bewertung von K{\"u}hlsystemen f{\"u}r K{\"u}hllager}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {49}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {9}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {74 -- 77}, year = {1998}, language = {de} } @article{ThulfautGross2000, author = {Thulfaut, Christian and Groß, Rolf Fritz}, title = {Experimentelle Untersuchung der Luftstromvermischung in Hybridzellenk{\"u}hlt{\"u}rmen}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {51}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {8}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {48 -- 49}, year = {2000}, abstract = {Zwangsbel{\"u}ftete Nassk{\"u}hlt{\"u}rme haben im Gegensatz zur Trockenk{\"u}hlung bei naßkaltem Wetter Nebelschwaden zur Folge. Dagegen ist bei Naßk{\"u}hlung die spezifische K{\"u}hlleistung durch abgef{\"u}hrte Kondensationsw{\"a}rme h{\"o}her als bei der Trockenk{\"u}hlung. Hybridzellenk{\"u}hlt{\"u}rme kombinieren beide Methoden, so daß ein Mischstrom beider Abluftstr{\"o}me die Wasserdampf-S{\"a}ttigungsgrenze nicht {\"u}berschreitet. Durch das Mischungsverh{\"a}ltnis kann man den gew{\"u}nschten S{\"a}ttigungsgrad einstellen. Je dichter dieser an der S{\"a}ttigungsgrenze liegt, desto h{\"o}her ist die K{\"u}hlleistung. Der von unten zugef{\"u}hrte Luftstrom der Naßk{\"u}hlung und der seitlich zugef{\"u}hrte trockene Abluftstrom m{\"u}ssen sehr gut durchmischt werden, um {\"u}ber den gesamten Austrittsquerschnitt des K{\"u}hlturms die S{\"a}ttigungsgrenze nicht zu {\"u}berschreiten. In einem maßstabsgerechten Modell wurde der Mischungsgrad mit und ohne Einbauten untersucht. {\"U}ber ein Raster von 10 mal 10 Punkten wurde die {\"o}rtliche Temperaturverteilung ermittelt. W{\"a}rmebilanzen ergeben dann die Mischungsg{\"u}te in einer Ebene oberhalb der Zellenkrone. W{\"a}hrend ohne Mischeinbauten der Trockenluftanteil in der Mitte des Querschnitts bei unter 15 \% liegt erh{\"o}hen Einbauten den Trockenluftanteil auf 30 \% bis {\"u}ber 40 \%. Dabei wurde die Trockenluft auf jeder K{\"u}hlturmseite durch 4 konisch zulaufende, unten offene und oben geschlitzte Einbauten kanalisiert. Die Nassluft wurde durch eine im Querschnitt dreieckige Rinne in Richtung der Trockenluftausl{\"a}sse umgelenkt. Im Raster leicht zu lokalisierende Abweichungen vom gew{\"u}nschten Mittelwert zeigen Potential f{\"u}r die weitere Verbesserung der Einbauten.}, language = {de} } @article{GrossBergerGross2003, author = {Groß, Rolf Fritz and Berger, J. and Groß, H.}, title = {Geb{\"a}udeautomation - Betriebsdatenerfassung und Geb{\"a}udeleittechnik im Klartext}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {54}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {2}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {81}, year = {2003}, language = {de} } @article{GrossBerger2005, author = {Groß, Rolf Fritz and Berger, J.}, title = {Quo Vadis - Ausblick in die Geb{\"a}udeleittechnik der Zukunft}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {56}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {1}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {39 -- 41}, year = {2005}, abstract = {Auf dem Weg zum vernetzten Haus stoßen Hersteller und Planer, insbesondere im privaten Wohnungsbau, zur Zeit noch auf erhebliche Widerst{\"a}nde bei der Durchdringung des Marktes.}, language = {de} } @article{CheenakulaPaulsenOttetal.2023, author = {Cheenakula, Dheeraja and Paulsen, Svea and Ott, Fabian and Gr{\"o}mping, Markus}, title = {Operational window of a deammonifying sludge for mainstream application in a municipal wastewater treatment plant}, series = {Water and Environment Journal}, journal = {Water and Environment Journal}, number = {Early View}, publisher = {Wiley}, address = {Chichester}, issn = {1747-6593}, doi = {10.1111/wej.12898}, pages = {1 -- 12}, year = {2023}, abstract = {The present work aimed to study the mainstream feasibility of the deammonifying sludge of side stream of municipal wastewater treatment plant (MWWTP) in Kaster, Germany. For this purpose, the deammonifying sludge available at the side stream was investigated for nitrogen (N) removal with respect to the operational factors temperature (15-30°C), pH value (6.0-8.0) and chemical oxygen demand (COD)/N ratio (≤1.5-6.0). The highest and lowest N-removal rates of 0.13 and 0.045 kg/(m³ d) are achieved at 30 and 15°C, respectively. Different conditions of pH and COD/N ratios in the SBRs of Partial nitritation/anammox (PN/A) significantly influenced both the metabolic processes and associated N-removal rates. The scientific insights gained from the current work signifies the possibility of mainstream PN/A at WWTPs. The current study forms a solid basis of operational window for the upcoming semi-technical trails to be conducted prior to the full-scale mainstream PN/A at WWTP Kaster and WWTPs globally.}, language = {en} } @article{CheenakulaGriebelMontagetal.2023, author = {Cheenakula, Dheeraja and Griebel, Kai and Montag, David and Gr{\"o}mping, Markus}, title = {Concept development of a mainstream deammonification and comparison with conventional process in terms of energy, performance and economical construction perspectives}, series = {Frontiers in Microbiology}, volume = {14}, journal = {Frontiers in Microbiology}, number = {11155235}, editor = {Huang, Xiaowu}, publisher = {Frontiers}, issn = {1664-302X}, doi = {10.3389/fmicb.2023.1155235}, pages = {1 -- 15}, year = {2023}, abstract = {Deammonification for nitrogen removal in municipal wastewater in temperate and cold climate zones is currently limited to the side stream of municipal wastewater treatment plants (MWWTP). This study developed a conceptual model of a mainstream deammonification plant, designed for 30,000 P.E., considering possible solutions corresponding to the challenging mainstream conditions in Germany. In addition, the energy-saving potential, nitrogen elimination performance and construction-related costs of mainstream deammonification were compared to a conventional plant model, having a single-stage activated sludge process with upstream denitrification. The results revealed that an additional treatment step by combining chemical precipitation and ultra-fine screening is advantageous prior the mainstream deammonification. Hereby chemical oxygen demand (COD) can be reduced by 80\% so that the COD:N ratio can be reduced from 12 to 2.5. Laboratory experiments testing mainstream conditions of temperature (8-20°C), pH (6-9) and COD:N ratio (1-6) showed an achievable volumetric nitrogen removal rate (VNRR) of at least 50 gN/(m3∙d) for various deammonifying sludges from side stream deammonification systems in the state of North Rhine-Westphalia, Germany, where m3 denotes reactor volume. Assuming a retained Norganic content of 0.0035 kgNorg./(P.E.∙d) from the daily loads of N at carbon removal stage and a VNRR of 50 gN/(m3∙d) under mainstream conditions, a resident-specific reactor volume of 0.115 m3/(P.E.) is required for mainstream deammonification. This is in the same order of magnitude as the conventional activated sludge process, i.e., 0.173 m3/(P.E.) for an MWWTP of size class of 4. The conventional plant model yielded a total specific electricity demand of 35 kWh/(P.E.∙a) for the operation of the whole MWWTP and an energy recovery potential of 15.8 kWh/(P.E.∙a) through anaerobic digestion. In contrast, the developed mainstream deammonification model plant would require only a 21.5 kWh/(P.E.∙a) energy demand and result in 24 kWh/(P.E.∙a) energy recovery potential, enabling the mainstream deammonification model plant to be self-sufficient. The retrofitting costs for the implementation of mainstream deammonification in existing conventional MWWTPs are nearly negligible as the existing units like activated sludge reactors, aerators and monitoring technology are reusable. However, the mainstream deammonification must meet the performance requirement of VNRR of about 50 gN/(m3∙d) in this case.}, language = {en} } @article{HoerenbaumLaumannProkop2016, author = {H{\"o}renbaum, Christoph and Laumann, J{\"o}rg and Prokop, Ines}, title = {Zur Anwendung des Eurocode 3 Teil 1-2 f{\"u}r die Heißbemessung und Anregungen f{\"u}r dessen Novellierung}, series = {Stahlbau}, volume = {85}, journal = {Stahlbau}, number = {6}, publisher = {Ernst \& Sohn GmbH}, address = {Berlin}, issn = {1437-1049}, doi = {10.1002/stab.201610382}, pages = {429 -- 434}, year = {2016}, abstract = {Die Eurocodes werden bis zum Jahr 2020 im Europ{\"a}ischen Komitee f{\"u}r Normung (CEN), Technisches Komitee TC 250, {\"u}berarbeitet. In Vorbereitung auf die Eurocode-Novellierung haben engagierte Ingenieure im Rahmen der Initiative PraxisRegeln Bau (PRB) die f{\"u}r die praktische Anwendung h{\"a}ufig genutzten Teile des Eurocode 3 untersucht. Mit dem Ziel, die Praxistauglichkeit des Eurocode 3 f{\"u}r die Heißbemessung zu verbessern, wurden die bestehende Norm EN 1993 Teil 1-2 insbesondere in Bezug auf die Anwenderfreundlichkeit analysiert und Vorschl{\"a}ge f{\"u}r die europ{\"a}ische Novellierung erarbeitet. Die Analysen zeigen, dass durch Umstrukturierungen und durch die Einf{\"u}hrung von Tabellen die Verst{\"a}ndlichkeit und Anwenderfreundlichkeit der Regeln f{\"u}r die Heißbemessung bedeutend erh{\"o}ht werden k{\"o}nnen.}, language = {de} } @article{KindmannKrausLaumannetal.2022, author = {Kindmann, Rolf and Kraus, Matthias and Laumann, J{\"o}rg and Vette, Jan}, title = {Verallgemeinerte Berechnungsmethode f{\"u}r in Beton eingespannte Stahlprofile - Einspanntiefen, Tragf{\"a}higkeitsnachweise und Bemessungshilfen}, series = {Stahlbau}, volume = {93}, journal = {Stahlbau}, number = {Early View}, publisher = {Ernst \& Sohn GmbH}, address = {Berlin}, issn = {1437-1049}, doi = {10.1002/stab.202200024}, pages = {1 -- 25}, year = {2022}, abstract = {St{\"u}tzen und Tr{\"a}ger aus Stahlprofilen k{\"o}nnen in Fundamente oder W{\"a}nde aus Stahlbeton einbetoniert werden. Diese Anschl{\"u}sse wirken in der Regel wie Einspannungen, die eine ausreichende Einspanntiefe erfordern. Im Folgenden wird eine verallgemeinerte Berechnungsmethode f{\"u}r in Stahlbetonkonstruktionen eingespannte Stahlprofile aus gewalzten I-Profilen, geschweißten I-Profilen, runden Hohlprofilen, eckigen Hohlprofilen und einzelligen Kastenquerschnitten vorgestellt. F{\"u}r Beanspruchungen infolge einachsiger Biegung um die starke und schwache Profilachse werden der profilabh{\"a}ngige Ansatz der Betondruckspannungen im Einspannbereich und die Ermittlung der Einspanntiefe behandelt. Unter Ber{\"u}cksichtigung der Normalkraft werden an den maßgebenden Stellen Tragf{\"a}higkeitsnachweise f{\"u}r die Stahlprofile gef{\"u}hrt. Als Erg{\"a}nzung zu den Berechnungsformeln werden Bemessungshilfen zur Verf{\"u}gung gestellt, die die Wahl der mitwirkenden Breiten und der Einspanntiefen erleichtert.}, language = {de} }