@article{MuribYeapEurlingsetal.2016, author = {Murib, M. S. and Yeap, W. S. and Eurlings, Y. and Grinsven, B. van and Boyen, H.-G. and Conings, B. and Michiels, L. and Ameloot, M. and Carleer, R. and Warmer, J. and Kaul, P. and Haenen, K. and Sch{\"o}ning, Michael Josef and Ceuninck, W. de and Wagner, P.}, title = {Heat-transfer based characterization of DNA on synthetic sapphire chips}, series = {Sensors and Actuators B: Chemical}, volume = {230}, journal = {Sensors and Actuators B: Chemical}, number = {230}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2016.02.027}, pages = {260 -- 271}, year = {2016}, abstract = {In this study, we show that synthetic sapphire (Al₂O₃), an established implant material, can also serve as a platform material for biosensors comparable to nanocrystalline diamond. Sapphire chips, beads, and powder were first modified with (3-aminopropyl) triethoxysilane (APTES), followed by succinic anhydride (SA), and finally single-stranded probe DNA was EDC coupled to the functionalized layer. The presence of the APTES-SA layer on sapphire powders was confirmed by thermogravimetric analyis and Fourier-transform infrared spectroscopy. Using planar sapphire chips as substrates and X-ray photoelectron spectroscopy (XPS) as surface-sensitive tool, the sequence of individual layers was analyzed with respect to their chemical state, enabling the quantification of areal densities of the involved molecular units. Fluorescence microscopy was used to demonstrate the hybridization of fluorescently tagged target DNA to the probe DNA, including denaturation- and re-hybridization experiments. Due to its high thermal conductivity, synthetic sapphire is especially suitable as a chip material for the heat-transfer method, which was employed to distinguish complementary- and non-complementary DNA duplexes containing single-nucleotide polymorphisms. These results indicate that it is possible to detect mutations electronically with a chemically resilient and electrically insulating chip material.}, language = {en} } @article{HamadBilattoAdlyetal.2016, author = {Hamad, E. M. and Bilatto, S. E. R. and Adly, N. Y. and Correa, D. S. and Wolfrum, B. and Sch{\"o}ning, Michael Josef and Offenh{\"a}usser, A. and Yakushenko, A.}, title = {Inkjet printing of UV-curable adhesive and dielectric inks for microfluidic devices}, series = {Lab on a Chip}, volume = {16}, journal = {Lab on a Chip}, number = {1}, publisher = {Royal Society of Chemistry}, address = {Cambridge}, issn = {1473-0189}, doi = {10.1039/C5LC01195G}, pages = {70 -- 74}, year = {2016}, abstract = {Bonding of polymer-based microfluidics to polymer substrates still poses a challenge for Lab-On-a-Chip applications. Especially, when sensing elements are incorporated, patterned deposition of adhesives with curing at ambient conditions is required. Here, we demonstrate a fabrication method for fully printed microfluidic systems with sensing elements using inkjet and stereolithographic 3D-printing.}, language = {en} } @article{MiyamotoYuIsodaetal.2016, author = {Miyamoto, Ko-ichiro and Yu, Bing and Isoda, Hiroko and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Visualization of the recovery process of defects in a cultured cell layer by chemical imaging sensor}, series = {Sensors and Actuators B: Chemical}, volume = {236}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2016.04.018}, pages = {965 -- 969}, year = {2016}, abstract = {The chemical imaging sensor is a field-effect sensor which is able to visualize both the distribution of ions (in LAPS mode) and the distribution of impedance (in SPIM mode) in the sample. In this study, a novel cell assay is proposed, in which the chemical imaging sensor operated in SPIM mode is applied to monitor the recovery of defects in a cell layer brought into proximity of the sensing surface. A reduced impedance at a defect formed artificially in a cell layer was successfully visualized in a photocurrent image. The cell layer was cultured over two weeks, during which the temporal change of the photocurrent distribution corresponding to the recovery of the defect was observed.}, language = {de} } @article{DantismTakenagaWagneretal.2016, author = {Dantism, Shahriar and Takenaga, Shoko and Wagner, Patrick and Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Determination of the extracellular acidification of Escherichia coli K12 with a multi-​chamber-​based LAPS system}, series = {Physica status solidi (a)}, volume = {213}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6300}, doi = {10.1002/pssa.201533043}, pages = {1479 -- 1485}, year = {2016}, abstract = {On-line monitoring of the metabolic activity of microorganisms involved in intermediate stages of biogas production plays an important role to avoid undesirable "down times" during the biogas production. In order to control this process, an on-chip differential measuring system based on the light-addressable potentiometric sensor (LAPS) principle combined with a 3D-printed multi-chamber structure has been realized. As a test microorganism, Escherichia coli K12 (E. coli K12) were used for cell-based measurements. Multi-chamber structures were developed to determine the metabolic activity of E. coli K12 in suspension for a different number of cells, responding to the addition of a constant or variable amount of glucose concentrations, enabling differential and simultaneous measurements.}, language = {en} } @inproceedings{SchreiberKraftZuendorf2016, author = {Schreiber, Marc and Kraft, Bodo and Z{\"u}ndorf, Albert}, title = {Cost-efficient quality assurance of natural language processing tools through continuous monitoring with continuous integration}, series = {3rd International Workshop on Software Engineering Research and Industrial Practice}, booktitle = {3rd International Workshop on Software Engineering Research and Industrial Practice}, doi = {10.1145/2897022.2897029}, pages = {46 -- 52}, year = {2016}, language = {en} } @article{BreuerRaueStrobeletal.2016, author = {Breuer, Lars and Raue, Markus and Strobel, M. and Mang, Thomas and Sch{\"o}ning, Michael Josef and Thoelen, R. and Wagner, Torsten}, title = {Hydrogels with incorporated graphene oxide as light-addressable actuator materials for cell culture environments in lab-on-chip systems}, series = {Physica status solidi (a)}, volume = {213}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6300}, doi = {10.1002/pssa.201533056}, pages = {1520 -- 1525}, year = {2016}, abstract = {Abstractauthoren Graphene oxide (GO) nanoparticles were incorporated in temperature-sensitive Poly(N-isopropylacrylamide) (PNIPAAm) hydrogels. The nanoparticles increase the light absorption and convert light energy into heat efficiently. Thus, the hydrogels with GO can be stimulated spatially resolved by illumination as it was demonstrated by IR thermography. The temporal progression of the temperature maximum was detected for different concentrations of GO within the polymer network. Furthermore, the compatibility of PNIPAAm hydrogels with GO and cell cultures was investigated. For this purpose, culture medium was incubated with hydrogels containing GO and the viability and morphology of chinese hamster ovary (CHO) cells was examined after several days of culturing in presence of this medium.}, language = {en} } @article{PookhalilAmoabedinyTabeshetal.2016, author = {Pookhalil, Ali and Amoabediny, Ghassem and Tabesh, Hadi and Behbahani, Mehdi and Mottaghy, Khosrow}, title = {A new approach for semiempirical modeling of mechanical blood trauma}, series = {The international journal of artificial organs}, volume = {39}, journal = {The international journal of artificial organs}, number = {4}, publisher = {Sage}, address = {London}, issn = {1724-6040}, doi = {10.5301/ijao.5000474}, pages = {171 -- 177}, year = {2016}, abstract = {Purpose Two semi-empirical models were recently published, both making use of existing literature data, but each taking into account different physical phenomena that trigger hemolysis. In the first model, hemoglobin (Hb) release is described as a permeation procedure across the membrane, assuming a shear stress-dependent process (sublethal model). The second model only accounts for hemoglobin release that is caused by cell membrane breakdown, which occurs when red blood cells (RBC) undergo mechanically induced shearing for a period longer than the threshold time (nonuniform threshold model). In this paper, we introduce a model that considers the hemolysis generated by both these possible phenomena. Methods Since hemolysis can possibly be caused by permeation of hemoglobin through the RBC functional membrane as well as by release of hemoglobin from RBC membrane breakdown, our proposed model combines both these models. An experimental setup consisting of a Couette device was utilized for validation of our proposed model. Results A comparison is presented between the damage index (DI) predicted by the proposed model vs. the sublethal model vs. the nonthreshold model and experimental datasets. This comparison covers a wide range of shear stress for both human and porcine blood. An appropriate agreement between the measured DI and the DI predicted by the present model was obtained. Conclusions The semiempirical hemolysis model introduced in this paper aims for significantly enhanced conformity with experimental data. Two phenomenological outcomes become possible with the proposed approach: an estimation of the average time after which cell membrane breakdown occurs under the applied conditions, and a prediction of the ratio between the phenomena involved in hemolysis.}, language = {en} } @incollection{Bialonski2016, author = {Bialonski, Stephan}, title = {Are interaction clusters in epileptic networks predictive of seizures?}, series = {Epilepsy: The Intersection of Neurosciences, Biology, Mathematics, Engineering, and Physics}, booktitle = {Epilepsy: The Intersection of Neurosciences, Biology, Mathematics, Engineering, and Physics}, publisher = {CRC Press}, isbn = {978-143983886-0}, pages = {349 -- 355}, year = {2016}, language = {en} } @article{NgamgaBialonskiMarwanetal.2016, author = {Ngamga, Eulalie Joelle and Bialonski, Stephan and Marwan, Norbert and Kurths, J{\"u}rgen and Geier, Christian and Lehnertz, Klaus}, title = {Evaluation of selected recurrence measures in discriminating pre-ictal and inter-ictal periods from epileptic EEG data}, series = {Physics Letters A}, volume = {380}, journal = {Physics Letters A}, number = {16}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0375-9601}, doi = {10.1016/j.physleta.2016.02.024}, pages = {1419 -- 1425}, year = {2016}, abstract = {We investigate the suitability of selected measures of complexity based on recurrence quantification analysis and recurrence networks for an identification of pre-seizure states in multi-day, multi-channel, invasive electroencephalographic recordings from five epilepsy patients. We employ several statistical techniques to avoid spurious findings due to various influencing factors and due to multiple comparisons and observe precursory structures in three patients. Our findings indicate a high congruence among measures in identifying seizure precursors and emphasize the current notion of seizure generation in large-scale epileptic networks. A final judgment of the suitability for field studies, however, requires evaluation on a larger database.}, language = {en} } @inproceedings{BhattaraiFrotscherStaat2016, author = {Bhattarai, Aroj and Frotscher, Ralf and Staat, Manfred}, title = {Significance of fibre geometry on passive-active response of pelvic muscles to evaluate pelvic dysfunction}, series = {BioMedWomen: Proceedings of the international conference on clinical and bioengineering for women's health}, booktitle = {BioMedWomen: Proceedings of the international conference on clinical and bioengineering for women's health}, editor = {Natal Jorge, Renato}, publisher = {CRC Press}, address = {Boca Raton}, isbn = {978-1-138-02910-1}, pages = {185 -- 188}, year = {2016}, language = {en} } @article{KowalskiLinderZierkeetal.2016, author = {Kowalski, Julia and Linder, Peter and Zierke, S. and Wulfen, B. van and Clemens, J. and Konstantinidis, K. and Ameres, G. and Hoffmann, R. and Mikucki, J. and Tulaczyk, S. and Funke, O. and Blandfort, D. and Espe, Clemens and Feldmann, Marco and Francke, Gero and Hiecker, S. and Plescher, Engelbert and Sch{\"o}ngarth, Sarah and Dachwald, Bernd and Digel, Ilya and Artmann, Gerhard and Eliseev, D. and Heinen, D. and Scholz, F. and Wiebusch, C. and Macht, S. and Bestmann, U. and Reineking, T. and Zetzsche, C. and Schill, K. and F{\"o}rstner, R. and Niedermeier, H. and Szumski, A. and Eissfeller, B. and Naumann, U. and Helbing, K.}, title = {Navigation technology for exploration of glacier ice with maneuverable melting probes}, series = {Cold Regions Science and Technology}, journal = {Cold Regions Science and Technology}, number = {123}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0165-232X}, doi = {10.1016/j.coldregions.2015.11.006}, pages = {53 -- 70}, year = {2016}, abstract = {The Saturnian moon Enceladus with its extensive water bodies underneath a thick ice sheet cover is a potential candidate for extraterrestrial life. Direct exploration of such extraterrestrial aquatic ecosystems requires advanced access and sampling technologies with a high level of autonomy. A new technological approach has been developed as part of the collaborative research project Enceladus Explorer (EnEx). The concept is based upon a minimally invasive melting probe called the IceMole. The force-regulated, heater-controlled IceMole is able to travel along a curved trajectory as well as upwards. Hence, it allows maneuvers which may be necessary for obstacle avoidance or target selection. Maneuverability, however, necessitates a sophisticated on-board navigation system capable of autonomous operations. The development of such a navigational system has been the focal part of the EnEx project. The original IceMole has been further developed to include relative positioning based on in-ice attitude determination, acoustic positioning, ultrasonic obstacle and target detection integrated through a high-level sensor fusion. This paper describes the EnEx technology and discusses implications for an actual extraterrestrial mission concept.}, language = {en} } @inproceedings{JungStaat2016, author = {Jung, Alexander and Staat, Manfred}, title = {Computing olympic gold: Ski jumping as an example}, series = {1st YRA MedTech Symposium 2016 : April 8th / 2016 / University of Duisburg-Essen}, booktitle = {1st YRA MedTech Symposium 2016 : April 8th / 2016 / University of Duisburg-Essen}, editor = {Erni, Daniel}, publisher = {Universit{\"a}t Duisburg-Essen}, address = {Duisburg}, organization = {MedTech Symposium}, isbn = {978-3-940402-06-6}, doi = {10.17185/duepublico/40821}, pages = {54 -- 55}, year = {2016}, language = {en} } @inproceedings{DuongJungFrotscheretal.2016, author = {Duong, Minh Tuan and Jung, Alexander and Frotscher, Ralf and Staat, Manfred}, title = {A 3D electromechanical FEM-based model for cardiac tissue}, series = {ECCOMAS Congress 2016, VII European Congress on Computational Methods in Applied Sciences and Engineering. Crete Island, Greece, 5-10 June 2016}, booktitle = {ECCOMAS Congress 2016, VII European Congress on Computational Methods in Applied Sciences and Engineering. Crete Island, Greece, 5-10 June 2016}, editor = {Papadrakakis, M.}, pages = {13 S.}, year = {2016}, language = {en} } @article{HacklKahmannWegmannetal.2016, author = {Hackl, Michael and Kahmann, Stephanie Lucina and Wegmann, Kilian and Ries, Christian and Staat, Manfred and M{\"u}ller, Lars-Peter}, title = {Shortening osteotomy of the proximal radius — a treatment option for isolated osteoarthritis of the lateral column of the elbow joint?}, series = {Knee surgery, sports traumatology, arthroscopy}, volume = {Volume 24}, journal = {Knee surgery, sports traumatology, arthroscopy}, number = {Supplement 1}, publisher = {Springer}, address = {Berlin}, issn = {0942-2056}, doi = {10.1007/s00167-016-4080-7}, pages = {128 -- 129}, year = {2016}, abstract = {Treatment of posttraumatic osteoarthritis of the radial column of the elbow joint remains a challenging yet common issue. While partial joint replacement leads to high revision rates, radial head excision has shown to severely increase joint instability. Shortening osteotomy of the radius could be an option to decrease the contact pressure of the radiohumeral joint and thereby pain levels without causing valgus instability. Hence, the aim of this biomechanical study was to evaluate the effects of radial shortening on axial load distribution and valgus stability of the elbow joint.}, language = {en} } @article{KnobeGiesenPlateetal.2016, author = {Knobe, M. and Giesen, M. and Plate, S. and Gradl-Dietsch, G. and Buecking, B. and Eschbach, D. and Laack, Walter van and Pape, H.-C.}, title = {The Aachen mobility and balance index to measure physiological falls risk: a comparison with the Tinetti POMA scale}, series = {European Journal Of Trauma And Emergency Surgery}, volume = {42}, journal = {European Journal Of Trauma And Emergency Surgery}, number = {5}, publisher = {Springer}, address = {Berlin}, issn = {1863-9941}, doi = {10.1007/s00068-016-0693-2}, pages = {537 -- 545}, year = {2016}, abstract = {Purpose The most commonly used mobility assessments for screening risk of falls among older adults are rating scales such as the Tinetti performance oriented mobility assessment (POMA). However, its correlation with falls is not always predictable and disadvantages of the scale include difficulty to assess many of the items on a 3-point scale and poor specificity. The purpose of this study was to describe the ability of the new Aachen Mobility and Balance Index (AMBI) to discriminate between subjects with a fall history and subjects without such events in comparison to the Tinetti POMA Scale. Methods For this prospective cohort study, 24 participants in the study group and 10 in the control group were selected from a population of patients in our hospital who had met the stringent inclusion criteria. Both groups completed the Tinetti POMA Scale (gait and balance component) and the AMBI (tandem stance, tandem walk, ten-meter-walk-test, sit-to-stand with five repetitions, 360° turns, timed-up-and-go-test and measurement of the dominant hand grip strength). A history of falls and hospitalization in the past year were evaluated retrospectively. The relationships among the mobility tests were examined with Bland-Altmananalysis. Receiver-operated characteristics curves, sensitivity and specificity were calculated. Results The study showed a strong negative correlation between the AMBI (17 points max., highest fall risk) and Tinetti POMA Scale (28 points max., lowest fall risk; r = -0.78, p < 0.001) with an excellent discrimination between community-dwelling older people and a younger control group. However, there were no differences in any of the mobility and balance measurements between participants with and without a fall history with equal characteristics in test comparison (AMBI vs. Tinetti POMA Scale: AUC 0.570 vs. 0.598; p = 0.762). The Tinetti POMA Scale (cut-off <20 points) showed a sensitivity of 0.45 and a specificity of 0.69, the AMBI a sensitivity of 0.64 and a specificity of 0.46 (cut-off >5 points). Conclusion The AMBI comprises mobility and balance tasks with increasing difficulty as well as a measurement of the dominant hand-grip strength. Its ability to identify fallers was comparable to the Tinetti POMA Scale. However, both measurement sets showed shortcomings in discrimination between fallers and non-fallers based on a self-reported retrospective falls-status.}, language = {en} } @article{KotliarLanzl2016, author = {Kotliar, Konstantin and Lanzl, I. M.}, title = {Mit Statistik gemeistert: perfekte Augentropfen und idealer Screeningtest : M{\"o}glichkeiten und Grenzen statistischer Methoden beim Glaukom}, series = {Der Ophthalmologe: Zeitschrift Der Deutschen Ophthalmologischen Gesellschaft}, journal = {Der Ophthalmologe: Zeitschrift Der Deutschen Ophthalmologischen Gesellschaft}, number = {113}, publisher = {Springer}, address = {Berlin}, issn = {0941-293X}, doi = {10.1007/s00347-016-0312-y}, pages = {838 -- 843}, year = {2016}, abstract = {Hintergrund Die Anwendung und das Verst{\"a}ndnis von Statistik sind sehr wichtig f{\"u}r die biomedizinische Forschung und f{\"u}r die klinische Praxis. Dies gilt insbesondere auch zur Absch{\"a}tzung der M{\"o}glichkeiten unterschiedlichster Diagnostik- und Therapieoptionen beim Glaukom. Die scheinbare Komplexit{\"a}t der Statistik, die zum Teil dem „gesunden Menschenverstand" zu widersprechen scheint, zusammen mit der nur vorsichtigen Akzeptanz der Statistik bei vielen Medizinern k{\"o}nnen zu bewussten und unbewussten Manipulationen bei der Datendarstellung und -interpretation f{\"u}hren. Ziel der Arbeit Ziel ist die verst{\"a}ndliche Darstellung einiger typischer Fehler in der medizinisch-statistischen Datenbehandlung. Material und Methoden Anhand hypothetischer Beispiele aus der Glaukomdiagnostik erfolgen die Darstellung der Wirkung eines hypotensiven Medikamentes sowie die Beurteilung der Ergebnisse eines diagnostischen Tests. Es werden die typischsten statistischen Einsatzbereiche und Irrtumsquellen ausf{\"u}hrlich und verst{\"a}ndlich analysiert Ergebnisse Mechanismen von Datenmanipulation und falscher Dateninterpretation werden aufgekl{\"a}rt. Typische Irrtumsquellen bei der statistischen Auswertung und Datendarstellung werden dabei erl{\"a}utert. Schlussfolgerungen Die erl{\"a}uterten praktischen Beispiele zeigen die Notwendigkeit, die Grundlagen der Statistik zu verstehen und korrekt anwenden zu k{\"o}nnen. Fehlendes Grundlagenwissen und Halbwissen der medizinischen Statistik k{\"o}nnen zu folgenschweren Missverst{\"a}ndnissen und falschen Entscheidungen in der medizinischen Forschung, aber auch in der klinischen Praxis f{\"u}hren.}, language = {de} } @article{AlbannaConzenWeissetal.2016, author = {Albanna, W. and Conzen, C. and Weiss, M. and Clusmann, H. and Fuest, M. and Mueller, M. and Brockmann, M.A. and Vilser, W. and Schmidt-Trucks{\"a}ss, A. and Hoellig, A. and Seiz, M. and Thom{\´e}, C. and Kotliar, Konstantin and Schubert, G.A.}, title = {Retinal Vessel Analysis (RVA) in the context of subarachnoid hemorrhage: A proof of concept study}, series = {PLoS ONE}, volume = {11}, journal = {PLoS ONE}, number = {7}, publisher = {PLOS}, address = {San Francisco}, issn = {1932-6203}, doi = {10.1371/journal.pone.0158781}, pages = {13 Seiten}, year = {2016}, abstract = {Background Timely detection of impending delayed cerebral ischemia after subarachnoid hemorrhage (SAH) is essential to improve outcome, but poses a diagnostic challenge. Retinal vessels as an embryological part of the intracranial vasculature are easily accessible for analysis and may hold the key to a new and non-invasive monitoring technique. This investigation aims to determine the feasibility of standardized retinal vessel analysis (RVA) in the context of SAH. Methods In a prospective pilot study, we performed RVA in six patients awake and cooperative with SAH in the acute phase (day 2-14) and eight patients at the time of follow-up (mean 4.6±1.7months after SAH), and included 33 age-matched healthy controls. Data was acquired using a manoeuvrable Dynamic Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and neurovascular coupling. Results Image quality was satisfactory in the majority of cases (93.3\%). In the acute phase after SAH, retinal arteries were significantly dilated when compared to the control group (124.2±4.3MU vs 110.9±11.4MU, p<0.01), a difference that persisted to a lesser extent in the later stage of the disease (122.7±17.2MU, p<0.05). Testing for neurovascular coupling showed a trend towards impaired primary vasodilation and secondary vasoconstriction (p = 0.08, p = 0.09 resp.) initially and partial recovery at the time of follow-up, indicating a relative improvement in a time-dependent fashion. Conclusion RVA is technically feasible in patients with SAH and can detect fluctuations in vessel diameter and autoregulation even in less severely affected patients. Preliminary data suggests potential for RVA as a new and non-invasive tool for advanced SAH monitoring, but clinical relevance and prognostic value will have to be determined in a larger cohort.}, language = {en} } @inproceedings{HafnerOchsWeickertetal.2016, author = {Hafner, David and Ochs, Peter and Weickert, Joachim and Reißel, Martin}, title = {FSI Schemes : Fast Semi-Iterative Solvers for PDEs and Optimisation Methods}, series = {Pattern Recognition : 38th German Conference, GCPR 2016, Hannover, Germany, September 12-15, 2016, Proceedings}, booktitle = {Pattern Recognition : 38th German Conference, GCPR 2016, Hannover, Germany, September 12-15, 2016, Proceedings}, editor = {Rosenhahn, Bodo}, publisher = {Springer}, isbn = {978-3-319-45886-1}, doi = {10.1007/978-3-319-45886-1_8}, pages = {91 -- 102}, year = {2016}, language = {de} } @article{WagnerVornholtWerneretal.2016, author = {Wagner, Torsten and Vornholt, Wolfgang and Werner, Frederik and Yoshinobu, Tatsuo and Miyamoto, Ko-Ichiro and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Light-addressable potentiometric sensor (LAPS) combined with magnetic beads for pharmaceutical screening}, series = {Physics in medicine}, volume = {2016}, journal = {Physics in medicine}, number = {1}, issn = {2352-4510}, doi = {10.1016/j.phmed.2016.03.001}, pages = {2 -- 7}, year = {2016}, abstract = {The light-addressable potentiometric sensor (LAPS) has the unique feature to address different regions of a sensor surface without the need of complex structures. Measurements at different locations on the sensor surface can be performed in a common analyte solution, which distinctly simplifies the fluidic set-up. However, the measurement in a single analyte chamber prevents the application of different drugs or different concentrations of a drug to each measurement spot at the same time as in the case of multi-reservoir-based set-ups. In this work, the authors designed a LAPS-based set-up for cell culture screening that utilises magnetic beads loaded with the endotoxin (lipopolysaccharides, LPS), to generate a spatially distributed gradient of analyte concentration. Different external magnetic fields can be adjusted to move the magnetic beads loaded with a specific drug within the measurement cell. By recording the metabolic activities of a cell layer cultured on top of the LAPS surface, this work shows the possibility to apply different concentrations of a sample along the LAPS measurement spots within a common analyte solution.}, language = {en} } @article{DollWagnerWagneretal.2016, author = {Doll, Theodor and Wagner, Torsten and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Engineering of functional interfaces / Theodor Doll ; Torsten Wagner ; Patrick Wagner ; Michael J. Sch{\"o}ning (eds.)}, series = {Physica status solidi (a)}, volume = {213}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201670641}, pages = {1393 -- 1394}, year = {2016}, language = {en} }