@inproceedings{ChaiybounTrauteKiesewetteretal.2006, author = {Chaiyboun, Ali and Traute, R{\"u}diger and Kiesewetter, Olaf and Ahlers, Simon and M{\"u}ller, Gerhard and Doll, Theodor}, title = {Modular analytical multicomponent analysis in gas sensor arrays}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1358}, year = {2006}, abstract = {A multi-sensor system is a chemical sensor system which quantitatively and qualitatively records gases with a combination of cross-sensitive gas sensor arrays and pattern recognition software. This paper addresses the issue of data analysis for identification of gases in a gas sensor array. We introduce a software tool for gas sensor array configuration and simulation. It concerns thereby about a modular software package for the acquisition of data of different sensors. A signal evaluation algorithm referred to as matrix method was used specifically for the software tool. This matrix method computes the gas concentrations from the signals of a sensor array. The software tool was used for the simulation of an array of five sensors to determine gas concentration of CH4, NH3, H2, CO and C2H5OH. The results of the present simulated sensor array indicate that the software tool is capable of the following: (a) identify a gas independently of its concentration; (b) estimate the concentration of the gas, even if the system was not previously exposed to this concentration; (c) tell when a gas concentration exceeds a certain value. A gas sensor data base was build for the configuration of the software. With the data base one can create, generate and manage scenarios and source files for the simulation. With the gas sensor data base and the simulation software an on-line Web-based version was developed, with which the user can configure and simulate sensor arrays on-line.}, subject = {Biosensor}, language = {en} } @inproceedings{Roeth2002, author = {R{\"o}th, Thilo}, title = {Modularisierung in der Karosserie von morgen}, year = {2002}, abstract = {1) Module werden die Fahrzeugplattform und den -aufbau in Zukunft weiterhin und in zunehmendem Maße bestimmen. 2) Neue Module und Modulschnittstellen am Fahrzeug werden {\"u}berdacht und k{\"o}nnen in der Zukunft erwartet werden. 3) Die Wertsch{\"o}pfung und der Entwicklungsumfang wird sich vom OEM zum Modullieferanten verlagern. 4) Modulvergaben werden in der Zukunft noch st{\"a}rker auf Innovation und Kostenreduktion beruhen. 5) Modularisierung des Fahrzeuges heißt ein Aufbrechen der Fahrzeugkarosserie und wird daher von der Beherrschung struktureller Aufgaben sowie der L{\"o}sung der (sichtbaren) Modul{\"u}berg{\"a}nge bestimmt sein. 6) Neben den Systemintegratoren und den Komponentenspezialisten besetzen die Modullieferanten die erste Lieferantenriege. 7) Der Modullieferant wird neben h{\"o}chster Fertigungsexpertise ein hohes Maß an (Teil-)fahrzeug-Know-How und Produktentwickler-mentalit{\"a}t bereitstellen.}, subject = {Karosseriebau}, language = {de} } @masterthesis{Wrutniak2021, type = {Bachelor Thesis}, author = {Wrutniak, Sophia Stefanie}, title = {Monitoring-System f{\"u}r die Luftrettung: ergonomisches Designkonzept f{\"u}r den medizinischen Anwender}, publisher = {FH Aachen}, address = {Aachen}, school = {Fachhochschule Aachen}, pages = {129 Seiten}, year = {2021}, abstract = {Bei einem Luftrettungseinsatz hat die Herstellung der Transportf{\"a}higkeit des Patienten Priorit{\"a}t. Im Anschluss erfolgt das Monitoring w{\"a}hrend des Fluges. Das Problem dabei ist: Es gibt keine einheitliche Basis zur ergonomischen Nutzung und Datenverwertung der medizinischen Ger{\"a}te. Kabel, Positionierung und individuelle Displays beeintr{\"a}chtigen die Anwendenden. Dies kann im schlimmsten Fall die erfolgreiche Patientenbehandlung gef{\"a}hrden und die {\"U}bergabe des Patienten verz{\"o}gern. Im Konzept wurden die Ger{\"a}te drahtlos gestaltet. Mittels Knopfdruck am Ger{\"a}t werden Daten an den Monitor {\"u}bertragen. Schnell und sicher k{\"o}nnen EKG, Blutdruck, SPO2 und Temperatur gemessen und Stethoskop, Ultraschall und Videolaryngoskop verwendet werden. Ein Barcode-Scanner dokumentiert Medikamente und verbrauchte Materialien. Im Anschluss wird ein Zielkrankenhaus ausgew{\"a}hlt, die Ankunftszeit angezeigt und Daten protokolliert und {\"u}bertragen.}, language = {de} } @inproceedings{Wessling2007, author = {Weßling, Matthias}, title = {Motivation and Leadership - The Reiss-Profile of the 16 Basic Desires: Research results and managerial applications}, year = {2007}, abstract = {Recent Results of the scientific Reiss-Profile (16 basic desires) due to the concept of Prof. Dr. Steven Reiss (State University Ohio, U.S.A.), supplemented by the comparative analysis of empirical motivational profiles of european executives of various companies.}, subject = {Motivation}, language = {en} } @article{Lohr2000, author = {Lohr, J{\"u}rgen}, title = {MPEG-Standards f{\"u}r Multimedia-Dienste (Video-Standards f{\"u}r Multimedia)}, year = {2000}, abstract = {Zuerst erschienen in Telekom-Praxis Ausgabe 2000. 24 S. Innovative multimediale Dienste werden durch die Globalisierung und Konvergenz der M{\"a}rkte, als auch durch Provider-Strategien ausgerichtet. Grundlegende Innovationsfelder sind: Globaler Zugang, Navigation und Intelligenter Inhalt. Die MPEG-Standards - im besonderen MPEG-4 und MPEG-7 - helfen, die oben genannten Forderungen zu erf{\"u}llen. Weiterhin erm{\"o}glichen sie auch f{\"u}r die Provider und den Kunden eine Zukunftssicherheit zu geben und einen zeitlichen Bestand f{\"u}r innovative Produkte zu sichern. Die Aufw{\"a}rtkompabilit{\"a}t der MPEG-Standards erm{\"o}glicht die Vermeidung von {\"U}berschneidung und die Erschließung neuer Dimensionen.}, subject = {Multimediamarkt}, language = {de} } @inproceedings{BukhariYang2006, author = {Bukhari, Syed Faisal Ahmed and Yang, Wuqiang}, title = {Multi-interface level sensors and new development in monitoring and control of oil separators}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1498}, year = {2006}, abstract = {In the oil industry, huge saving may be made if suitable multi-interface level measurement systems are employed for effectively monitoring crude oil separators and efficient control of their operation. A number of techniques, e.g. externally mounted displacers, differential pressure transmitters and capacitance rod devices, have been developed to measure the separation process with gas, oil, water and other components. Because of the unavailability of suitable multi-interface level measurement systems, oil separators are currently operated by the trial-and-error approach. In this paper some conventional techniques, which have been used for level measurement in industry, and new development are discussed.}, subject = {Biosensor}, language = {en} } @article{AdelsElbersDiehletal.2023, author = {Adels, Klaudia and Elbers, Gereon and Diehl, Bernd and Monakhova, Yulia}, title = {Multicomponent analysis of dietary supplements containing glucosamine and chondroitin: comparative low- and high-field NMR spectroscopic study}, series = {Analytical Sciences}, volume = {2023}, journal = {Analytical Sciences}, publisher = {Springer Verlag}, address = {Cham}, issn = {1348-2246 (Online)}, doi = {10.1007/s44211-023-00433-2}, pages = {13 Seiten}, year = {2023}, abstract = {With the prevalence of glucosamine- and chondroitin-containing dietary supplements for people with osteoarthritis in the marketplace, it is important to have an accurate and reproducible analytical method for the quantitation of these compounds in finished products. NMR spectroscopic method based both on low- (80 MHz) and high- (500-600 MHz) field NMR instrumentation was established, compared and validated for the determination of chondroitin sulfate and glucosamine in dietary supplements. The proposed method was applied for analysis of 20 different dietary supplements. In the majority of cases, quantification results obtained on the low-field NMR spectrometer are similar to those obtained with high-field 500-600 MHz NMR devices. Validation results in terms of accuracy, precision, reproducibility, limit of detection and recovery demonstrated that the developed method is fit for purpose for the marketed products. The NMR method was extended to the analysis of methylsulfonylmethane, adulterant maltodextrin, acetate and inorganic ions. Low-field NMR can be a quicker and cheaper alternative to more expensive high-field NMR measurements for quality control of the investigated dietary supplements. High-field NMR instrumentation can be more favorable for samples with complex composition due to better resolution, simultaneously giving the possibility of analysis of inorganic species such as potassium and chloride.}, language = {en} } @misc{BisselsJahn2004, author = {Bissels, Anne and Jahn, Amelie}, title = {Multiplex}, year = {2004}, abstract = {Eine kurze Folge einer Fernsehsendung namens Multiplex. Gesendet wird ein Portait der kubanischen Diva Omara Portuondo auf Europatourn{\´e}e.}, subject = {Mediendesign}, language = {de} } @article{KarschuckSchmidtAchtsnichtetal.2023, author = {Karschuck, Tobias and Schmidt, Stefan and Achtsnicht, Stefan and Poghossian, Arshak and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Multiplexing system for automated characterization of a capacitive field-effect sensor array}, series = {Physica Status Solidi A}, volume = {220}, journal = {Physica Status Solidi A}, number = {22}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6300 (Print)}, doi = {10.1002/pssa.202300265}, pages = {7 Seiten}, year = {2023}, abstract = {In comparison to single-analyte devices, multiplexed systems for a multianalyte detection offer a reduced assay time and sample volume, low cost, and high throughput. Herein, a multiplexing platform for an automated quasi-simultaneous characterization of multiple (up to 16) capacitive field-effect sensors by the capacitive-voltage (C-V) and the constant-capacitance (ConCap) mode is presented. The sensors are mounted in a newly designed multicell arrangement with one common reference electrode and are electrically connected to the impedance analyzer via the base station. A Python script for the automated characterization of the sensors executes the user-defined measurement protocol. The developed multiplexing system is tested for pH measurements and the label-free detection of ligand-stabilized, charged gold nanoparticles.}, language = {en} } @misc{RoesslerKuehn2004, author = {R{\"o}ßler, Edith and K{\"u}hn, Nicola}, title = {Murphy's law}, year = {2004}, abstract = {Ein Kurzfilm {\"u}ber den letzten Morgen im Leben eines Mannes, das durch Murphy's Law gekennzeichnet ist}, subject = {Mediendesign}, language = {de} }