@article{DoorschodtSchreinemachersBehbahanietal.2011, author = {Doorschodt, B. M. and Schreinemachers, M. C. J. M. and Behbahani, Mehdi and Florquin, S. and Weis, J. and Staat, Manfred and Tolba, R. H.}, title = {Hypothermic machine perfusion of kidney grafts: which pressure is preferred}, series = {Annals of Biomedical Engineering. 39 (2011), H. 3}, journal = {Annals of Biomedical Engineering. 39 (2011), H. 3}, publisher = {Springer}, address = {Berlin}, isbn = {1573-9686}, pages = {1051 -- 1059}, year = {2011}, language = {en} } @article{Grotendorst2012, author = {Grotendorst, Johannes}, title = {IAS Winter School: Hierarchical Methods for Dynamics in Complex Molecular Systems}, series = {Innovatives Supercomputing in Deutschland : inSiDE. 10 (2012), H. 1}, journal = {Innovatives Supercomputing in Deutschland : inSiDE. 10 (2012), H. 1}, publisher = {-}, pages = {104}, year = {2012}, language = {en} } @article{HillenLehmannHornetal.1995, author = {Hillen, Walter and Lehmann, T. and Horn, H. and Schmitt, W.}, title = {IDEFIX - Identification of Dental Fixtures. Lehmann, T.; Hillen, W.; Horn, H.; Schmitt, W.}, series = {5th European Congress on Dental and Maxillo-Facial Radiology : 30th Annual meeting of Working Group for Dental Radiology in the German Scientific Society for Dentistry, November 8-11, 1995, Cologne : abstracts}, journal = {5th European Congress on Dental and Maxillo-Facial Radiology : 30th Annual meeting of Working Group for Dental Radiology in the German Scientific Society for Dentistry, November 8-11, 1995, Cologne : abstracts}, pages = {[120] B. : graph. Darst.}, year = {1995}, language = {en} } @article{WerfelGuenthnerHapfelmeieretal.2022, author = {Werfel, Stanislas and G{\"u}nthner, Roman and Hapfelmeier, Alexander and Hanssen, Henner and Kotliar, Konstantin and Heemann, Uwe and Schmaderer, Christoph}, title = {Identification of cardiovascular high-risk groups from dynamic retinal vessel signals using untargeted machine learning}, series = {Cardiovascular Research}, volume = {118}, journal = {Cardiovascular Research}, number = {2}, editor = {Guzik, Tomasz J.}, publisher = {Oxford University Press}, address = {Oxford}, issn = {0008-6363}, doi = {10.1093/cvr/cvab040}, pages = {612 -- 621}, year = {2022}, abstract = {Dynamic retinal vessel analysis (DVA) provides a non-invasive way to assess microvascular function in patients and potentially to improve predictions of individual cardiovascular (CV) risk. The aim of our study was to use untargeted machine learning on DVA in order to improve CV mortality prediction and identify corresponding response alterations.}, language = {en} } @article{HillenLehmannHornetal.1996, author = {Hillen, Walter and Lehmann, T. and Horn, H. and Schmitt, W.}, title = {Identification of Dental Fixtures in Intraoral X-rays. Lehmann, T.; Hillen, W.; Horn, H.; Schmitt, W.}, series = {Medical imaging 1996 : image processing ; 12 - 15 February 1996, Newport Beach, California / Murray H. Loew ... chairs/ed.}, journal = {Medical imaging 1996 : image processing ; 12 - 15 February 1996, Newport Beach, California / Murray H. Loew ... chairs/ed.}, publisher = {SPIE - The International Society for Optical Engineering}, address = {Bellingham, Wash.}, isbn = {0-8194-2085-9}, pages = {584 -- 584}, year = {1996}, language = {en} } @article{BialonskiLehnertz2006, author = {Bialonski, Stephan and Lehnertz, Klaus}, title = {Identifying phase synchronization clusters in spatially extended dynamical systems}, series = {Physical Review E}, volume = {74}, journal = {Physical Review E}, number = {5}, issn = {2470-0053}, doi = {10.1103/PhysRevE.74.051909}, pages = {051909}, year = {2006}, language = {en} } @article{MiyamotoSugawaraKanohetal.2010, author = {Miyamoto, Ko-ichiro and Sugawara, Yuri and Kanoh, Shin´ichiro and Yoshinobu, Tatsuo and Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Image correction method for the chemical imaging sensor}, series = {Sensors and Actuators B: Chemical. 144 (2010), H. 2}, journal = {Sensors and Actuators B: Chemical. 144 (2010), H. 2}, pages = {344 -- 348}, year = {2010}, language = {en} } @article{HillenSchiebelZaengel1986, author = {Hillen, Walter and Schiebel, U. and Zaengel, T.}, title = {Image quality in selenium-based digital radiography. Schiebel, U.; Hillen, W.; Zaengel, T.}, series = {Medical Imaging}, journal = {Medical Imaging}, pages = {176}, year = {1986}, language = {en} } @article{PhilippEfthimiouPaganoetal.2022, author = {Philipp, Mohr and Efthimiou, Nikos and Pagano, Fiammetta and Kratochwil, Nicolaus and Pizzichemi, Marco and Tsoumpas, Charalampos and Auffray, Etiennette and Ziemons, Karl}, title = {Image reconstruction analysis for positron emission tomography with heterostructured scintillators}, series = {IEEE Transactions on Radiation and Plasma Medical Sciences}, volume = {7}, journal = {IEEE Transactions on Radiation and Plasma Medical Sciences}, number = {1}, publisher = {IEEE}, address = {New York, NY}, issn = {2469-7311}, doi = {10.1109/TRPMS.2022.3208615}, pages = {41 -- 51}, year = {2022}, abstract = {The concept of structure engineering has been proposed for exploring the next generation of radiation detectors with improved performance. A TOF-PET geometry with heterostructured scintillators with a pixel size of 3.0×3.1×15 mm3 was simulated using Monte Carlo. The heterostructures consisted of alternating layers of BGO as a dense material with high stopping power and plastic (EJ232) as a fast light emitter. The detector time resolution was calculated as a function of the deposited and shared energy in both materials on an event-by-event basis. While sensitivity was reduced to 32\% for 100 μm thick plastic layers and 52\% for 50 μm, the CTR distribution improved to 204±49 ps and 220±41 ps respectively, compared to 276 ps that we considered for bulk BGO. The complex distribution of timing resolutions was accounted for in the reconstruction. We divided the events into three groups based on their CTR and modeled them with different Gaussian TOF kernels. On a NEMA IQ phantom, the heterostructures had better contrast recovery in early iterations. On the other hand, BGO achieved a better contrast to noise ratio (CNR) after the 15th iteration due to the higher sensitivity. The developed simulation and reconstruction methods constitute new tools for evaluating different detector designs with complex time responses.}, language = {en} } @article{HillenSchiebelZaengel1987, author = {Hillen, Walter and Schiebel, U. and Zaengel, T.}, title = {Imaging performance of a digital storage phosphor system}, series = {Medical Physics. 14 (1987), H. 5}, journal = {Medical Physics. 14 (1987), H. 5}, isbn = {0094-2405}, pages = {744 -- 751}, year = {1987}, language = {en} } @article{HillenRuppSchiebeletal.1989, author = {Hillen, Walter and Rupp, S. and Schiebel, U. and Zaengel, Thomas T.}, title = {Imaging performance of a selenium-based detector for high-resolution radiography}, series = {Medical Imaging III: Image Formation}, journal = {Medical Imaging III: Image Formation}, isbn = {0-8194-0125-0}, pages = {296}, year = {1989}, language = {en} } @article{MourzinaYoshinobuErmolenkoetal.2004, author = {Mourzina, I.G. and Yoshinobu, T. and Ermolenko, Y.E. and Vlasov, Y. G. and Sch{\"o}ning, Michael Josef and Iwasaki, H.}, title = {Immobilization of urease and cholinesterase on the surface of semiconductor transducer for the development of light-addressable potentiometric sensors}, series = {Technical digest of the 10th International Meeting on Chemical Sensors, July 11 - 14, 2004, Tsukuba, Japan / Japan Association of Chemical Sensors}, journal = {Technical digest of the 10th International Meeting on Chemical Sensors, July 11 - 14, 2004, Tsukuba, Japan / Japan Association of Chemical Sensors}, publisher = {Japan Association of Chemical Sensors}, address = {Fukuoka}, pages = {788 -- 789}, year = {2004}, language = {en} } @article{MourzinaYoshinobuErmolenkoetal.2004, author = {Mourzina, Ioulia G. and Yoshinobu, Tatsuo and Ermolenko, Yuri E. and Vlasov, Yuri G. and Sch{\"o}ning, Michael Josef and Iwasaki, H.}, title = {Immobilization of urease and cholinesterase on the surface of semiconductor transducer for the development of lightaddressable potentiometric sensors}, series = {Microchimica Acta. 144 (2004), H. 1-3}, journal = {Microchimica Acta. 144 (2004), H. 1-3}, isbn = {0026-3672}, pages = {41 -- 50}, year = {2004}, language = {en} } @article{BogoyavlenskiyBerezinOgnevaetal.1999, author = {Bogoyavlenskiy, A. P. and Berezin, V. E. and Ogneva, A. V. and Tolmacheva, V. P. and Digel, Ilya and Khudyakova, S. S.}, title = {Immunostimulating activity of a saponin-containing extract of Saponaria officinalis}, series = {Voprosy virusologii}, volume = {44}, journal = {Voprosy virusologii}, number = {5}, issn = {0507-4088}, pages = {229 -- 232}, year = {1999}, language = {en} } @inproceedings{KahmannHacklWegmannetal.2016, author = {Kahmann, Stephanie and Hackl, Michael and Wegmann, Kilian and M{\"u}ller, Lars-Peter and Staat, Manfred}, title = {Impact of a proximal radial shortening osteotomy on the distribution of forces and the stability of the elbow}, series = {1st YRA MedTech Symposium 2016 : April 8th / 2016 / University of Duisburg-Essen}, booktitle = {1st YRA MedTech Symposium 2016 : April 8th / 2016 / University of Duisburg-Essen}, editor = {Erni, Daniel}, publisher = {Universit{\"a}t Duisburg-Essen}, address = {Duisburg}, organization = {MedTech Symposium}, doi = {10.17185/duepublico/40821}, pages = {7 -- 8}, year = {2016}, abstract = {The human arm consists of the humerus (upper arm), the medial ulna and the lateral radius (forearm). The joint between the humerus and the ulna is called humeroulnar joint and the joint between the humerus and the radius is called humeroradial joint. Lateral and medial collateral ligaments stabilize the elbow. Statistically, 2.5 out of 10,000 people suffer from radial head fractures [1]. In these fractures the cartilage is often affected. Caused by the injured cartilage, degenerative diseases like posttraumatic arthrosis may occur. The resulting pain and reduced range of motion have an impact on the patient's quality of life. Until now, there has not been a treatment which allows typical loads in daily life activities and offers good long-term results. A new surgical approach was developed with the motivation to reduce the progress of the posttraumatic arthrosis. Here, the radius is shortened by 3 mm in the proximal part [2]. By this means, the load of the radius is intended to be reduced due to a load shift to the ulna. Since the radius is the most important stabilizer of the elbow it has to be confirmed that the stability is not affected. In the first test (Fig. 1 left), pressure distributions within the humeroulnar and humeroradial joints a native and a shortened radius were measured using resistive pressure sensors (I5076 and I5027, Tekscan, USA). The humerus was loaded axially in a tension testing machine (Z010, Zwick Roell, Germany) in 50 N steps up to 400 N. From the humerus the load is transmitted through both the radius and the ulna into the hand which is fixed on the ground. In the second test (Fig. 1 right), the joint stability was investigated using a digital image correlation system to measure the displacement of the ulna. Here, the humerus is fixed with a desired flexion angle and the unconstrained forearm lies on the ground. A rope connects the load actuator with a hook fixed in the ulna. A guide roller is used so that the rope pulls the ulna horizontally when a tensile load is applied. This creates a moment about the elbow joint with a maximum value of 7.5 Nm. Measurements were performed with varying flexion angles (0°, 30°, 60°, 90°, 120°). For both tests and each measurement, seven specimens were used. Student's t-test was employed to determine whether the mean values of the measurements in native specimen and operated specimens differ significantly.}, language = {en} } @article{WeberHekmatZimmermannetal.2004, author = {Weber, Hans-Joachim and Hekmat, K. and Zimmermann, T. and Kampe, S.}, title = {Impact of tranexamic acid vs. aprotinin on blood loss and transfusion requirements after cardiopulmonary bypass: a prospective, randomised, double-blind trial / Hekmat, K. ; Zimmermann, T. ; Kampe, S. ; Kasper, S. M. ; Weber, H. J. ; Geissler, H. J. ; Meh}, series = {Current Medical Research and Opinion. 20 (2004), H. 1}, journal = {Current Medical Research and Opinion. 20 (2004), H. 1}, isbn = {0300-7995}, pages = {121 -- 126}, year = {2004}, language = {en} } @article{PoghossianMaiMourzinaetal.2004, author = {Poghossian, Arshak and Mai, D.-T. and Mourzina, Y. and Sch{\"o}ning, Michael Josef}, title = {Impedance effect of an ion-sensitive membrane: characterisation of an EMIS sensor by impedance spectroscopy, capacitance-voltage and constant-capacitance method}, series = {Sensors and Actuators B. 103 (2004), H. 1-2}, journal = {Sensors and Actuators B. 103 (2004), H. 1-2}, isbn = {0925-4005}, pages = {423 -- 428}, year = {2004}, language = {en} } @article{SchusserLeinhosBaeckeretal.2013, author = {Schusser, Sebastian and Leinhos, Marcel and B{\"a}cker, Matthias and Poghossian, Arshak and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Impedance spectroscopy: A tool for real-time in situ monitoring of the degradation of biopolymers}, series = {Physica Status Solidi (A)}, volume = {210}, journal = {Physica Status Solidi (A)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1521-396X ; 0031-8965}, doi = {10.1002/pssa.201200941}, pages = {905 -- 910}, year = {2013}, abstract = {Investigation of the degradation kinetics of biodegradable polymers is essential for the development of implantable biomedical devices with predicted biodegradability. In this work, an impedimetric sensor has been applied for real-time and in situ monitoring of degradation processes of biopolymers. The sensor consists of two platinum thin-film electrodes covered by a polymer film to be studied. The benchmark biomedical polymer poly(D,L-lactic acid) (PDLLA) was used as a model system. PDLLA films were deposited on the sensor structure from a polymer solution by using the spin-coating method. The degradation kinetics of PDLLA films have been studied in alkaline solutions of pH 9 and 12 by means of an impedance spectroscopy (IS) method. Any changes in a polymer capacitance/resistance induced by water uptake and/or polymer degradation will modulate the global impedance of the polymer-covered sensor that can be used as an indicator of the polymer degradation. The degradation rate can be evaluated from the time-dependent impedance spectra. As expected, a faster degradation has been observed for PDLLA films exposed to pH 12 solution.}, language = {en} } @inproceedings{OberlaenderArreolaHansenetal.2017, author = {Oberl{\"a}nder, Jan and Arreola, Julio and Hansen, Christina and Greeff, Anton and Mayer, Marlena and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Impedimetric Biosensor to Enable Fast Evaluation of Gaseous Sterilization Processes}, series = {MDPI Proceedings}, volume = {1}, booktitle = {MDPI Proceedings}, number = {4}, doi = {10.3390/proceedings1040435}, pages = {4 Seiten}, year = {2017}, language = {en} } @article{RiedelKartchemnikSchoeningetal.2014, author = {Riedel, Marc and Kartchemnik, Julia and Sch{\"o}ning, Michael Josef and Lisdat, Fred}, title = {Impedimetric DNA detection - steps forward to sensorial application}, series = {Analytical chemistry}, volume = {86 (2014)}, journal = {Analytical chemistry}, number = {15}, publisher = {ACS Publications}, address = {Columbus}, issn = {1520-6882 (E-Journal); 0003-2700 (Print); 0096-4484 (Print)}, doi = {10.1021/ac501800q}, pages = {7867 -- 7874}, year = {2014}, abstract = {This study describes a label-free impedimetric sensor based on short ssDNA recognition elements for the detection of hybridization events. We concentrate on the elucidation of the influence of target length and recognition sequence position on the sensorial performance. The impedimetric measurements are performed in the presence of the redox system ferri-/ferrocyanide and show an increase in charge transfer resistance upon hybridization of ssDNA to the sensor surface. Investigations on the impedimetric signal stability demonstrate a clear influence of the buffers used during the sensor preparation and the choice of the passivating mercaptoalcanol compound. A stable sensor system has been developed, enabling a reproducible detection of 25mer target DNA in the low nanomolar range. After hybridization, a sensor regeneration can be reached with deionized water by adjustment of effective convection conditions, ensuring a sensor reusability. By investigations of longer targets with overhangs exposed to the solution, we can demonstrate applicability of the impedimetric detection for longer ssDNA. However, a decreasing charge transfer resistance change (ΔRct) is found by extending the overhang. As a strategy to increase the impedance change for longer target strands, the position of the recognition sequence can be designed in a way that a small overhang is exposed to the electrode surface. This is found to result in an increase in the relative Rct change. These results suggest that DNA and consequently negative charge near the electrode possess a larger impact on the impedimetric signal than DNA further away.}, language = {en} } @article{DelleHuckBaeckeretal.2015, author = {Delle, Lotta E. and Huck, Christina and B{\"a}cker, Matthias and M{\"u}ller, Frank and Grandthyll, Samuel and Jacobs, Karin and Lilischkis, Rainer and Vu, Xuan T. and Sch{\"o}ning, Michael Josef and Wagner, Patrick and Thoelen, Roland and Weil, Maryam and Ingebrandt, Sven}, title = {Impedimetric immunosensor for the detection of histamine based on reduced graphene oxide}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431863}, pages = {1327 -- 1334}, year = {2015}, language = {en} } @article{SchaeferBoegeShanjiaetal.1994, author = {Sch{\"a}fer, Horst and Boege, P. and Shanjia, Xu and Xinzhang, Wu (u.a.)}, title = {Improved conductivity-measurement of semiconductor epitaxial layers by means of the contactless microwave method}, series = {Conference digest : 10 - 14 January 1994, San Diego, California / International Conference on Millimeter and Submillimeter Waves and Applications / Mohammed N. Afsar, chair/ed.}, journal = {Conference digest : 10 - 14 January 1994, San Diego, California / International Conference on Millimeter and Submillimeter Waves and Applications / Mohammed N. Afsar, chair/ed.}, publisher = {SPIE}, address = {Bellingham, Wash.}, isbn = {0-8194-1558-8}, pages = {649 -- 658}, year = {1994}, language = {en} } @article{MiyamotoSekiSutoetal.2018, author = {Miyamoto, Koichiro and Seki, Kosuke and Suto, Takeyuki and Werner, Frederik and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Improved spatial resolution of the chemical imaging sensor with a hybrid illumination that suppresses lateral diffusion of photocarriers}, series = {Sensor and Actuators B: Chemical}, volume = {273}, journal = {Sensor and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2018.07.016}, pages = {1328 -- 1333}, year = {2018}, abstract = {The chemical imaging sensor is a semiconductor-based chemical sensor capable of visualizing pH and ion distributions. The spatial resolution depends on the lateral diffusion of photocarriers generated by illumination of the semiconductor substrate. In this study, two types of optical setups, one based on a bundle of optical fibers and the other based on a binocular tube head, were developed to project a hybrid illumination of a modulated light beam and a ring-shaped constant illumination onto the sensor plate. An improved spatial resolution was realized by the ring-shaped constant illumination, which suppressed lateral diffusion of photocarriers by enhanced recombination due to the increased carrier concentration.}, language = {en} } @article{GriessmeierSonnenbergWeckesseretal.1996, author = {Grießmeier, M. and Sonnenberg, F. and Weckesser, M. and Ziemons, Karl and Langen, K.-J. and M{\"u}ller-G{\"a}rtner, H. W.}, title = {Improvement of SPECT quantification in small brain structures by using experiment based recovery-coefficient corrections}, series = {European Journal of Nuclear Medicine}, volume = {23}, journal = {European Journal of Nuclear Medicine}, number = {9}, issn = {1619-7089}, pages = {1238 -- 1238}, year = {1996}, language = {en} } @article{SchrothSchoeningSchuetzetal.1999, author = {Schroth, P. and Sch{\"o}ning, Michael Josef and Sch{\"u}tz, S. and Epanya, P. and Steffen, A. and Weißbecker, B. and Hummel, Hans E. and Kordos, P. and L{\"u}th, H.}, title = {Improving the bioelectronic interface of an antenna/chip biosensor - technological aspects}, series = {Proceedings : The Hague, The Netherlands, September 12 - 15, 1999 / [ed. by M. Bartek]. Vol 1.}, journal = {Proceedings : The Hague, The Netherlands, September 12 - 15, 1999 / [ed. by M. Bartek]. Vol 1.}, address = {The Hague, The Netherlands}, isbn = {90-76699-02-X}, pages = {569 -- 572}, year = {1999}, language = {en} } @article{ThustSchrothToepleretal.1998, author = {Thust, M. and Schroth, P. and T{\"o}pler, A. and Sch{\"o}ning, Michael Josef and M{\"u}ller-Veggian, Mattea and Kordos, P. and L{\"u}th, H.}, title = {Improving the detection limit of a capacitive sensor by means of a diffusion barrier}, series = {Eurosensors XII : proceedings of the 12th European Conference on Solid-State Transducers and the 9th UK Conference on Sensors and their Applications, Southampton, UK, 13 - 16 September 1998 / ed. by N. M. White ; Vol. 1}, journal = {Eurosensors XII : proceedings of the 12th European Conference on Solid-State Transducers and the 9th UK Conference on Sensors and their Applications, Southampton, UK, 13 - 16 September 1998 / ed. by N. M. White ; Vol. 1}, publisher = {Inst. of Physics Publ.}, address = {Bristol [u.a.]}, isbn = {0-7503-0595-9}, pages = {507 -- 510}, year = {1998}, language = {en} } @article{TemizArtmannResmiAkhunlaretal.2005, author = {Temiz Artmann, Ayseg{\"u}l and Resmi, Halil and Akhunlar, H{\"u}lya and G{\"u}ner, G{\"u}l}, title = {In vitro effects of high glucose concentrations on membrane protein sulfhydryl oxidation, G-actin and deformability of human erythrocytes. Resmi, Halil ; Akhunlar, H{\"u}lya ; Temiz Artmann, Ayseg{\"u}l ; G{\"u}ner, G{\"u}l}, series = {Cell biochemistry and function. 23 (2005), H. 3}, journal = {Cell biochemistry and function. 23 (2005), H. 3}, isbn = {0263-6484}, pages = {163 -- 168}, year = {2005}, language = {en} } @article{TemizArtmannBaskurtEdremitlioglu1994, author = {Temiz Artmann, Ayseg{\"u}l and Baskurt, O. K. and Edremitlioglu, M.}, title = {In vitro effects of in vivo activated leukocytes on red blood cell filterability and lipid peroxidation. Baskurt, O.K.; Edremitlioglu, M.; Temiz, A.}, series = {Clinical Hemorheology. 14 (1994), H. 4}, journal = {Clinical Hemorheology. 14 (1994), H. 4}, pages = {591 -- 596}, year = {1994}, language = {en} } @article{BleilevensHillGrzannaetal.2019, author = {Bleilevens, Christian and Hill, Aileen and Grzanna, Tim and Fechter, Tamara and Bohnen, Melanie and Weber, Hans-Joachim and Beckers, Christian and Borosch, Sebastian and Zayat, Rashad and Benstoem, Carin and Rossaint, Rolf and Goetzenich, Andreas}, title = {In vitro head-to-head comparison of anticoagulation properties of two heparin brands in a human blood miniature mock loop}, series = {Interactive cardiovascular and thoracic surgery}, volume = {28}, journal = {Interactive cardiovascular and thoracic surgery}, number = {1}, issn = {1569-9285}, doi = {10.1093/icvts/ivy206}, pages = {120 -- 127}, year = {2019}, language = {en} } @article{BrockhausBehbahaniMurisetal.2021, author = {Brockhaus, Moritz K. and Behbahani, Mehdi and Muris, Farina and Jansen, Sebastian V. and Schmitz- Rode, Thomas and Steinseifer, Ulrich and Clauser, Johanna C.}, title = {In vitro thrombogenicity testing of pulsatile mechanical circulatory support systems: Design and proof-of-concept}, series = {Artificial Organs}, volume = {45}, journal = {Artificial Organs}, number = {12}, publisher = {Wiley}, address = {Weinheim}, issn = {1525-1594}, doi = {10.1111/aor.14046}, pages = {1513 -- 1521}, year = {2021}, abstract = {Thrombogenic complications are a main issue in mechanical circulatory support (MCS). There is no validated in vitro method available to quantitatively assess the thrombogenic performance of pulsatile MCS devices under realistic hemodynamic conditions. The aim of this study is to propose a method to evaluate the thrombogenic potential of new designs without the use of complex in-vivo trials. This study presents a novel in vitro method for reproducible thrombogenicity testing of pulsatile MCS systems using low molecular weight heparinized porcine blood. Blood parameters are continuously measured with full blood thromboelastometry (ROTEM; EXTEM, FIBTEM and a custom-made analysis HEPNATEM). Thrombus formation is optically observed after four hours of testing. The results of three experiments are presented each with two parallel loops. The area of thrombus formation inside the MCS device was reproducible. The implantation of a filter inside the loop catches embolizing thrombi without a measurable increase of platelet activation, allowing conclusions of the place of origin of thrombi inside the device. EXTEM and FIBTEM parameters such as clotting velocity (α) and maximum clot firmness (MCF) show a total decrease by around 6\% with a characteristic kink after 180 minutes. HEPNATEM α and MCF rise within the first 180 minutes indicate a continuously increasing activation level of coagulation. After 180 minutes, the consumption of clotting factors prevails, resulting in a decrease of α and MCF. With the designed mock loop and the presented protocol we are able to identify thrombogenic hot spots inside a pulsatile pump and characterize their thrombogenic potential.}, language = {en} } @inproceedings{WeberPorschenDietzeletal.1978, author = {Weber, Hans-Joachim and Porschen, W. and Dietzel, F. and [u.a.],}, title = {In vivo analysis of the influence of combined hyperthermia and gamma irradiation on euoxic and hypoxic tumor cells}, series = {Cancer therapy by hyperthermia and radiation : [proceedings of the 2. International Symposium on Cancer Therapy by Hyperthermia and Radiation, Essen, 2.-4.6.1977]}, booktitle = {Cancer therapy by hyperthermia and radiation : [proceedings of the 2. International Symposium on Cancer Therapy by Hyperthermia and Radiation, Essen, 2.-4.6.1977]}, editor = {Streffer, Christian}, publisher = {Urban and Schwarzenberg}, address = {Baltimore ; Munich [u.a.]}, isbn = {0-8067-1701-7}, pages = {276 -- 277}, year = {1978}, language = {en} } @article{PorschenGartzenGewehretal.1978, author = {Porschen, W. and Gartzen, J. and Gewehr, K. and M{\"u}hlensiepen, H. and Weber, Hans-Joachim and [u.a.],}, title = {In vivo assay of the radiation sensitivity of hypoxic tumour cells : influence of γ-rays, cyclotron neutrons, misonidazole, hyperthermia and mixed modalities}, series = {The British journal of cancer / Supplement}, journal = {The British journal of cancer / Supplement}, number = {3}, publisher = {Lewis}, address = {London}, issn = {0306-9443}, pages = {194 -- 197}, year = {1978}, abstract = {Tumour cell death can be evaluated in the living mouse by externally measuring the rate of loss of tumour-bound DNA tracer. By sequentially labelling the tumour-bearing animals with ¹²⁵IUdR and ¹³¹IUdR 50 h apart, the average tumour cells at the time of the second injection are labelled by ¹²⁵IUdR and the euoxic tumour cells are specifically labelled with ¹³¹IUdR. Tumour treatment at this stage of labelling permits the observation of the reaction of euoxic cells and average tumour cells and finally yields data on hypoxic cells and thus on the oxygen enhancement ratio. This information adds to results from tumour control and growth delay. With this technique effects were analysed of 60-Co γ-rays, cyclotron neutrons (E = 6 MeV), misonidazole (500 mg/kg body wt) and hyperthermia (42°C water-bath), or combinations of these. Misonidazole (15 min before irradiation) altered the oxygen enhancement ratio by a factor of 1·5 for γ-rays and of 1·1 for neutrons; when evaluated from tumour-growth delay and TCD-50 misonidazole gave a dose modifying factor of 1·47 for γ-rays and of 1·2-1·3 for neutrons. Based on percentage tumour regression 100 days after treatment, the enhancement ratio from hyperthermia (after irradiation) was 2·75 for γ-rays (at 10 Gray) and 2·2 for neutrons (at 3·2 Gray). For neutrons combined with misonidazole and hyperthermia the ratio was 2·4. These results demonstrate that effects of neutron irradiation may be modified by electron-affinic substances and/or hyperthermia.}, language = {en} } @inproceedings{RichterBraunsteinStaeudleetal.2018, author = {Richter, Charlotte and Braunstein, Bjoern and St{\"a}udle, Benjamin and Attias, Julia and Suess, Alexander and Weber, T. and Rittweger, Joern and Green, David A. and Albracht, Kirsten}, title = {In vivo fascicle length of the gastrocnemius muscle during walking in simulated martian gravity using two different body weight support devices}, series = {23rd Annual Congress of the European College of Sport Science, Dublin, Irland}, booktitle = {23rd Annual Congress of the European College of Sport Science, Dublin, Irland}, year = {2018}, language = {en} } @article{MuellerVeggianHaenniBeuscheretal.1979, author = {M{\"u}ller-Veggian, Mattea and Haenni, D. R. and Beuscher, H. and Lieder, R. M.}, title = {In-beam studies of ¹⁴⁵ Gd and ¹⁴⁵ Eu}, series = {Fr{\"u}hjahrstagung ... des Fachausschusses Kernphysik und Hochenergiephysik der DPG (Sektion A: Kernphysik) / Deutsche Physikalische Gesellschaft (1979)}, journal = {Fr{\"u}hjahrstagung ... des Fachausschusses Kernphysik und Hochenergiephysik der DPG (Sektion A: Kernphysik) / Deutsche Physikalische Gesellschaft (1979)}, year = {1979}, language = {en} } @article{MuellerVeggianZuberGueven1988, author = {M{\"u}ller-Veggian, Mattea and Zuber, K. and Gueven, H.}, title = {In-beam study of 63 143 Eu 80}, series = {Zeitschrift f{\"u}r Physik / A, Hadrons and nuclei. 330 (1988), H. 3}, journal = {Zeitschrift f{\"u}r Physik / A, Hadrons and nuclei. 330 (1988), H. 3}, isbn = {1431-5831}, pages = {343 -- 344}, year = {1988}, language = {en} } @article{MuellerVeggianHaenniBeuscheretal.1980, author = {M{\"u}ller-Veggian, Mattea and Haenni, D. R. and Beuscher, H. and Lieder, R. M.}, title = {In-beam study of levels in ¹⁴⁵ Eu}, series = {Structure of medium-heavy nuclei, 1979 : proceedings of the 6. European Physical Soc. Nuclear Divisional Conference on the Structure of Medium-Heavy Nuclei held in Rhodes, Greece, 1-4 May 1979 / ed. Committee: G. S. Anagnostatos ... - (Conference series / Institute of Physics London, Bristol ; 49)}, journal = {Structure of medium-heavy nuclei, 1979 : proceedings of the 6. European Physical Soc. Nuclear Divisional Conference on the Structure of Medium-Heavy Nuclei held in Rhodes, Greece, 1-4 May 1979 / ed. Committee: G. S. Anagnostatos ... - (Conference series / Institute of Physics London, Bristol ; 49)}, publisher = {Inst. of Physics}, address = {Bristol}, isbn = {0-85498-140-3}, pages = {131}, year = {1980}, language = {en} } @article{MuellerVeggianBeuscherHaenni1980, author = {M{\"u}ller-Veggian, Mattea and Beuscher, H. and Haenni, D. R.}, title = {In-beam study of the light transitional nucleus ¹³⁸ Nd}, series = {Annual report 1979 / Kernforschungsanlage J{\"u}lich Institut f{\"u}r Kernphysik / Hrsg.: A. F{\"a}ssler. - (Spezielle Berichte der Kernforschungsanlage J{\"u}lich ; 72)}, journal = {Annual report 1979 / Kernforschungsanlage J{\"u}lich Institut f{\"u}r Kernphysik / Hrsg.: A. F{\"a}ssler. - (Spezielle Berichte der Kernforschungsanlage J{\"u}lich ; 72)}, publisher = {Kernforschungsanlage}, address = {J{\"u}lich}, pages = {45}, year = {1980}, language = {en} } @article{MuellerVeggianMorekBeuscheretal.1985, author = {M{\"u}ller-Veggian, Mattea and Morek, T. and Beuscher, H. and Bochev, B.}, title = {In-beam study of the odd-odd nuclei ¹³⁴ La and ¹³⁶ La}, series = {Nuclear physics / A, Nuclear and hadronic physics. 433 (1985), H. 2}, journal = {Nuclear physics / A, Nuclear and hadronic physics. 433 (1985), H. 2}, isbn = {0375-9474}, pages = {159 -- 180}, year = {1985}, language = {en} } @article{MuellerVeggianZuberGueven1988, author = {M{\"u}ller-Veggian, Mattea and Zuber, K. and Gueven, H.}, title = {In-beam study of ¹⁴³ Eu}, series = {Annual report 1987 / Kernforschungsanlage J{\"u}lich Institut f{\"u}r Kernphysik / Gr{\"u}mmer , F. (Hrsg.) . - (Spezielle Berichte der Kernforschungsanlage J{\"u}lich ; 442)}, journal = {Annual report 1987 / Kernforschungsanlage J{\"u}lich Institut f{\"u}r Kernphysik / Gr{\"u}mmer , F. (Hrsg.) . - (Spezielle Berichte der Kernforschungsanlage J{\"u}lich ; 442)}, publisher = {Verlag des Forschungszentrums J{\"u}lich}, address = {J{\"u}lich}, pages = {44}, year = {1988}, language = {en} } @article{MuellerVeggianMariscottiBeuscheretal.1978, author = {M{\"u}ller-Veggian, Mattea and Mariscotti, M. A. J. and Beuscher, H. and Davidson, W. F.}, title = {In-beam study of ¹⁴⁴ Gd}, series = {Proceedings of the International Conference on Nuclear Structure : Tokyo, Sept. 5 - 10, 1977 / ed. by T. Marumori. - Journal of the Physical Society of Japan ; Vol. 44, 1978 : Suppl.}, journal = {Proceedings of the International Conference on Nuclear Structure : Tokyo, Sept. 5 - 10, 1977 / ed. by T. Marumori. - Journal of the Physical Society of Japan ; Vol. 44, 1978 : Suppl.}, publisher = {Physical Soc. of Japan}, address = {Tokyo}, pages = {863}, year = {1978}, language = {en} } @article{MuellerVeggianMariscottiBeuscheretal.1977, author = {M{\"u}ller-Veggian, Mattea and Mariscotti, M. A. J. and Beuscher, H. and Davidson, W. F.}, title = {In-beam study of ¹⁴⁴ Gd}, series = {Annual report 1976 / Institut f{\"u}r Kernphysik Kernforschungsanlage J{\"u}lich / Ed. board: A. F{\"a}ßler ...}, journal = {Annual report 1976 / Institut f{\"u}r Kernphysik Kernforschungsanlage J{\"u}lich / Ed. board: A. F{\"a}ßler ...}, publisher = {Kernforschungsanlage}, address = {J{\"u}lich}, pages = {37}, year = {1977}, language = {en} } @article{MuellerVeggianMariscottiBeuscheretal.1978, author = {M{\"u}ller-Veggian, Mattea and Mariscotti, M. A. J. and Beuscher, H. and Davidson, W. F.}, title = {In-beam study of ¹⁴⁴ Gd}, series = {Nuclear physics / A. 311 (1978), H. 3}, journal = {Nuclear physics / A. 311 (1978), H. 3}, isbn = {0375-9474}, pages = {395 -- 412}, year = {1978}, language = {en} } @article{MuellerVeggianHaenniBeuscheretal.1979, author = {M{\"u}ller-Veggian, Mattea and Haenni, D. R. and Beuscher, H. and Lieder, R. M.}, title = {In-beam study of ¹⁴⁵ Gd}, series = {Annual report 1978 / Kernforschungsanlage J{\"u}lich Institut f{\"u}r Kernphysik / Hrsg.: A. F{\"a}ssler. - (Spezielle Berichte der Kernforschungsanlage J{\"u}lich ; 36)}, journal = {Annual report 1978 / Kernforschungsanlage J{\"u}lich Institut f{\"u}r Kernphysik / Hrsg.: A. F{\"a}ssler. - (Spezielle Berichte der Kernforschungsanlage J{\"u}lich ; 36)}, publisher = {Kernforschungsanlage}, address = {J{\"u}lich}, pages = {27}, year = {1979}, language = {en} } @article{MuellerVeggianGonoLieder1979, author = {M{\"u}ller-Veggian, Mattea and Gono, Y. and Lieder, R. M.}, title = {In-beam γ-ray study of ¹⁸⁹,¹⁹¹,¹⁹³ Au}, series = {Nuclear physics / A. 327 (1979), H. 2}, journal = {Nuclear physics / A. 327 (1979), H. 2}, isbn = {0375-9474}, pages = {269 -- 287}, year = {1979}, language = {en} } @article{MuellerVeggianKreinerFenzletal.1978, author = {M{\"u}ller-Veggian, Mattea and Kreiner, A. J. and Fenzl, M. and Kutschera, W.}, title = {In-beam γ-spectroscopic investigation of ¹⁹⁶ Tl}, series = {Annual report 1977 / Institut f{\"u}r Kernphysik Kernforschungsanlage J{\"u}lich}, journal = {Annual report 1977 / Institut f{\"u}r Kernphysik Kernforschungsanlage J{\"u}lich}, publisher = {Verlag des Forschungszentrums J{\"u}lich}, address = {J{\"u}lich}, pages = {47 -- 48}, year = {1978}, language = {en} } @article{Digel2010, author = {Digel, Ilya}, title = {In-situ biological decontamination of an ice melting probe}, year = {2010}, language = {en} } @article{KuhnertBialonskiNoenningetal.2013, author = {Kuhnert, Marie-Therese and Bialonski, Stephan and Noenning, Nina and Mai, Heinke and Hinrichs, Hermann and Helmstaedter, Christoph and Lehnertz, Klaus}, title = {Incidental and intentional learning of verbal episodic material differentially modifies functional brain networks}, series = {Plos one}, volume = {8}, journal = {Plos one}, number = {11}, publisher = {PLOS}, address = {San Francisco}, doi = {10.1371/journal.pone.0080273}, pages = {e80273}, year = {2013}, abstract = {Learning- and memory-related processes are thought to result from dynamic interactions in large-scale brain networks that include lateral and mesial structures of the temporal lobes. We investigate the impact of incidental and intentional learning of verbal episodic material on functional brain networks that we derive from scalp-EEG recorded continuously from 33 subjects during a neuropsychological test schedule. Analyzing the networks' global statistical properties we observe that intentional but not incidental learning leads to a significantly increased clustering coefficient, and the average shortest path length remains unaffected. Moreover, network modifications correlate with subsequent recall performance: the more pronounced the modifications of the clustering coefficient, the higher the recall performance. Our findings provide novel insights into the relationship between topological aspects of functional brain networks and higher cognitive functions.}, language = {en} } @article{SiqueiraMolinnusBegingetal.2014, author = {Siqueira, Jose R. and Molinnus, Denise and Beging, Stefan and Sch{\"o}ning, Michael Josef}, title = {Incorporating a hybrid urease-carbon nanotubes sensitive nanofilm on capacitive field-effect sensors for urea detection}, series = {Analytical chemistry}, volume = {86}, journal = {Analytical chemistry}, number = {11}, publisher = {ACS Publications}, address = {Columbus}, issn = {1520-6882 (E-Journal); 0003-2700 (Print); 0096-4484 (Print)}, doi = {10.1021/ac500458s}, pages = {5370 -- 5375}, year = {2014}, abstract = {The ideal combination among biomolecules and nanomaterials is the key for reaching biosensing units with high sensitivity. The challenge, however, is to find out a stable and sensitive film architecture that can be incorporated on the sensor's surface. In this paper, we report on the benefits of incorporating a layer-by-layer (LbL) nanofilm of polyamidoamine (PAMAM) dendrimer and carbon nanotubes (CNTs) on capacitive electrolyte-insulator-semiconductor (EIS) field-effect sensors for detecting urea. Three sensor arrangements were studied in order to investigate the adequate film architecture, involving the LbL film with the enzyme urease: (i) urease immobilized directly onto a bare EIS [EIS-urease] sensor; (ii) urease atop the LbL film over the EIS [EIS-(PAMAM/CNT)-urease] sensor; and (iii) urease sandwiched between the LbL film and another CNT layer [EIS-(PAMAM/CNT)-urease-CNT]. The surface morphology of all three urea-based EIS biosensors was investigated by atomic force microscopy (AFM), while the biosensing abilities were studied by means of capacitance-voltage (C/V) and dynamic constant-capacitance (ConCap) measureaments at urea concentrations ranging from 0.1 mM to 100 mM. The EIS-urease and EIS-(PAMAM/CNT)-urease sensors showed similar sensitivity (∼18 mV/decade) and a nonregular signal behavior as the urea concentration increased. On the other hand, the EIS-(PAMAM/CNT)-urease-CNT sensor exhibited a superior output signal performance and higher sensitivity of about 33 mV/decade. The presence of the additional CNT layer was decisive to achieve a urea based EIS sensor with enhanced properties. Such sensitive architecture demonstrates that the incorporation of an adequate hybrid enzyme-nanofilm as sensing unit opens new prospects for biosensing applications using the field-effect sensor platform.}, language = {en} } @article{HeinzelSchaeferMuelleretal.2010, author = {Heinzel, Alexander and Sch{\"a}fer, Ralf and M{\"u}ller, Hans-Wilhelm and Schieffer, Andre and Ingenhag, Ariane and Eickhoff, Simon B. and Northoff, Georg and Franz, Matthias and Hautzel, Hubertus}, title = {Increased Activation of the Supragenual Anterior Cingulate Cortex during Visual Emotional Processing in Male Subjects with High Degrees of Alexithymia: An Event-Related fMRI Study}, series = {Psychotherapy and Psychosomatics}, volume = {79}, journal = {Psychotherapy and Psychosomatics}, number = {6}, publisher = {Karger}, address = {Basel}, issn = {0033-3190}, doi = {10.1159/000320121}, pages = {363 -- 370}, year = {2010}, abstract = {Background: One of the most prominent neurobiological models of alexithymia assumes an altered function of the anterior cingulate cortex (ACC) as the crucial neural correlate of alexithymia. So far functional imaging studies have yielded inconclusive results. Therefore, we tested this hypothesis in healthy alexithymics and nonalexithymics in an event-related fMRI study. Methods: Thirty high- and 30 low-alexithymic right-handed male subjects (selected by the 20-item Toronto Alexithymia Scale, TAS-20) were investigated with event-related fMRI using a picture viewing paradigm. The stimuli consisted of happy, fearful and neutral facial expressions (Ekman-Friesen) as well as positive, negative and neutral pictures from the International Affective Picture System. Results: Contrasting the high-alexithymic with the low-alexithymic group we observed increased activation of the supragenual ACC for different emotional valences as well as for different emotional stimuli. Moreover, there was a positive correlation of the ACC with the individual TAS-20 scores but no correlations with the individual Beck Depression Inventory scores. Additionally, there was no difference in activity of the amygdala. Conclusions: We demonstrated that the supragenual ACC is constantly activated more strongly in alexithymic subjects and that this activation is related to the symptoms of alexithymia and not to associated symptoms such as depression. Therefore, our findings support the hypothesis of an altered function of the ACC in alexithymia.}, language = {en} } @article{HeinkeKnickerAlbracht2020, author = {Heinke, Lars N. and Knicker, Axel J. and Albracht, Kirsten}, title = {Increased shoulder muscle stretch reflex elicitability in supine subject posture}, series = {Isokinetics and Exercise Science}, volume = {28}, journal = {Isokinetics and Exercise Science}, number = {2}, publisher = {IOS Press}, address = {Amsterdam}, issn = {1878-5913}, doi = {10.3233/IES-192219}, pages = {139 -- 146}, year = {2020}, abstract = {BACKGROUND: Muscle stretch reflexes are widely used to examine neural muscle function. The knowledge of reflex response in muscles crossing the shoulder is limited. OBJECTIVE: To quantify reflex modulation according to various subject postures and different procedures of muscle pre-activation steering. METHODS: Thirteen healthy male participants performed two sets of external shoulder rotation stretches in various positions and with different procedures of muscle pre-activation steering on an isokinetic dynamometer over a range of two different pre-activation levels. All stretches were applied with a dynamometer acceleration of 104∘/s2 and a velocity of 150∘/s. Electromyographical response was measured via sEMG. RESULTS: Consistent reflexive response was observed in all tested muscles in all experimental conditions. The reflex elicitation rate revealed a significant muscle main effect (F (5,288) = 2.358, ρ= 0.040; η2= 0.039; f= 0.637) and a significant test condition main effect (F (1,288) = 5.884, ρ= 0.016; η2= 0.020; f= 0.143). Reflex latency revealed a significant muscle pre-activation level main effect (F (1,274) = 5.008, ρ= 0.026; η2= 0.018; f= 0.469). CONCLUSION: Muscular reflexive response was more consistent in the primary internal rotators of the shoulder. Supine posture in combination with visual feedback of muscle pre-activation level enhanced the reflex elicitation rate.}, language = {en} }