@inproceedings{MelissSpaeteLange1999, author = {Meliß, Michael and Sp{\"a}te, Frank and Lange, Harald}, title = {The Solar-Campus J{\"u}lich - an interdisciplinary project}, series = {Building a new century. 5th Conference on Solar Architecture and Design, Bonn, 27th of May 1998. Ed. by Eurosolar e.V. Ed. by Irm Pontenagel.}, booktitle = {Building a new century. 5th Conference on Solar Architecture and Design, Bonn, 27th of May 1998. Ed. by Eurosolar e.V. Ed. by Irm Pontenagel.}, publisher = {Eurosolar-Verl.}, address = {Bonn}, isbn = {3-933745-03-9}, pages = {382 -- 387}, year = {1999}, language = {en} } @inproceedings{MelissSpaete1996, author = {Meliß, Michael and Sp{\"a}te, Frank}, title = {Solar-Campus J{\"u}lich - an interdisciplinary project}, series = {EuroSun '96 ; 10. Internationales Sonnenforum : proceedings. Bd 3}, booktitle = {EuroSun '96 ; 10. Internationales Sonnenforum : proceedings. Bd 3}, publisher = {DGS-Sonnenenergie}, address = {M{\"u}nchen}, pages = {1281 -- 1285}, year = {1996}, language = {en} } @inproceedings{SpaeteHafnerSchwarzer2000, author = {Sp{\"a}te, Frank and Hafner, B. and Schwarzer, Klemens}, title = {A system for solar process heat for decentralized applications in developing countries}, series = {ISES 1999 Solar World Congress, Jerusalem, Israel, July 4-9, 1999 : conference proceedings / ed. Gershon Grossman. Vol. 3}, booktitle = {ISES 1999 Solar World Congress, Jerusalem, Israel, July 4-9, 1999 : conference proceedings / ed. Gershon Grossman. Vol. 3}, publisher = {Elsevier}, address = {Oxford}, isbn = {0-080-043895-4}, pages = {236 -- 291}, year = {2000}, language = {en} } @incollection{KrokerHoffschmidtSchwarzeretal.2008, author = {Kroker, Jan and Hoffschmidt, Bernhard and Schwarzer, Klemens and Sp{\"a}te, Frank}, title = {PTC 1000 modular parabolic trough collector}, series = {Process heat collectors : state of the art within task 33/IV ; IEA SHC-Task 33 and SolarPACES-Task IV: Solar heat for industrial processes : F{\"o}rderkennzeichen BMBF 0329273A / Solar Heating and Cooling Executive Committee of the International Energy Agency (IEA) ; ed. Werner Weiss}, booktitle = {Process heat collectors : state of the art within task 33/IV ; IEA SHC-Task 33 and SolarPACES-Task IV: Solar heat for industrial processes : F{\"o}rderkennzeichen BMBF 0329273A / Solar Heating and Cooling Executive Committee of the International Energy Agency (IEA) ; ed. Werner Weiss}, publisher = {AEE INTEC}, address = {Gleisdorf}, pages = {45 -- 46}, year = {2008}, language = {en} } @inproceedings{HoffschmidtSchwarzerSpaeteetal.2006, author = {Hoffschmidt, Bernhard and Schwarzer, Klemens and Sp{\"a}te, Frank and K{\"o}tter, Jens and Ebert, Miriam and Sierck, Olaf}, title = {Development of a small modular parabolic trough collector}, series = {13th International Symposium Concentrated Solar Power and Chemical Energy Technologies : SolarPaces : June 20 - 23, 2006, Seville, Spain}, booktitle = {13th International Symposium Concentrated Solar Power and Chemical Energy Technologies : SolarPaces : June 20 - 23, 2006, Seville, Spain}, publisher = {SolarPaces}, address = {[o.O.]}, organization = {International Symposium on Concentrating Solar Power and Chemical Energy Systems <13, 2006, Sevilla>}, isbn = {8478345191}, pages = {1 CD-ROM}, year = {2006}, language = {en} } @inproceedings{DyllaFerreinLakemeyer2003, author = {Dylla, Frank and Ferrein, Alexander and Lakemeyer, Gerhard}, title = {AllemaniACs 2003 team description}, series = {RoboCup 2003 : Robot Soccer World Cup VII}, booktitle = {RoboCup 2003 : Robot Soccer World Cup VII}, pages = {1 -- 3}, year = {2003}, language = {en} } @article{WeemstraEilmannSassKlaassenetal.2013, author = {Weemstra, Monique and Eilmann, Britta and Sass-Klaassen, Ute G. W. and Sterck, Frank J.}, title = {Summer droughts limit tree growth across 10 temperate species on a productive forest site}, series = {Forest Ecology and Management}, volume = {2013}, journal = {Forest Ecology and Management}, number = {306}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0378-1127 (Print)}, doi = {doi:10.1016/j.foreco.2013.06.007}, pages = {142 -- 149}, year = {2013}, language = {en} } @article{EilmannSterckWegneretal.2014, author = {Eilmann, Britta and Sterck, Frank J. and Wegner, L. and de Vries, Sven M. G. and von Arx, G. and Mohren, Godefridus M. J. and den Ouden, Jan and Sass-Klaassen, Ute G. W.}, title = {Wood structural differences between northern and southern beech provenances growing at a moderate site}, series = {Tree Physiology}, volume = {34}, journal = {Tree Physiology}, number = {8}, publisher = {Oxford University Press}, address = {Oxford}, issn = {1758-4469 (Online)}, doi = {10.1093/treephys/tpu069}, pages = {882 -- 893}, year = {2014}, language = {en} } @inproceedings{KernKrichelMueller2001, author = {Kern, Alexander and Krichel, Frank and M{\"u}ller, Klaus-Peter}, title = {Lightning protection design of a renewable energy hybrid-system without power mains connection}, year = {2001}, abstract = {In the year 2000 a direct lightning strike to the hybridsystem without power mains connection VATALI on the Greek island Crete results in the destruction and damage of some mechanical and electrical components. The hybrid-system VATALI was not lightning protected at that time. The hardware damage costs are approx. 60,000 €. The exposed site of the hybrid-system on top of a mountain was and still is the reason for a high risk of lightning strikes. Also in the future further lightning strikes have to be taken into consideration. In the paper a fundamental lightning protection design concept for renewable energy hybrid-systems without power mains connection and protection measures against direct strikes and overvoltages are shown in detail. The design concept was realized exemplarily for the hybrid-system VATALI. The hardware costs for the protection measures were about 15,000 €. About 50\% of the costs are due to protection measures against direct strikes, 50\% are due to overvoltage protection. Future extensions, new installations, or modifications have to be included into the lightning protection design concept of the hybrid-system.}, language = {en} } @inproceedings{KernKrichel2002, author = {Kern, Alexander and Krichel, Frank}, title = {Considerations about the lightning protection system of mains independent renewable energy hybrid-systems - practical experiences}, year = {2002}, abstract = {In the paper a lightning protection design concept for renewable energy hybrid-systems without power mains connection is described. Based on a risk analysis protection measures against direct strikes and overvoltages are shown in an overview. The design concept is realized exemplarily for the hybrid-system VATALI on the Greek island Crete. VATALI, not lightning protected at that time, was a victim of a lightning strike in the year 2000 causing destructions and damages of some mechanical and electrical components with costs of approx. 60.000 €. The hardware costs for the protection measures were about 15.000 €: about 50\% of the costs are due to protection measures against direct strikes, 50\% are due to overvoltage protection.}, language = {en} }