@article{PoghossianWagnerSchoening2011, author = {Poghossian, Arshak and Wagner, Holger and Sch{\"o}ning, Michael Josef}, title = {Functional testing and characterisation of (bio-)chemical sensors on wafer level}, series = {Sensors and Actuators B: Chemical. 154 (2011), H. 2}, journal = {Sensors and Actuators B: Chemical. 154 (2011), H. 2}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1873-3077}, pages = {169 -- 173}, year = {2011}, language = {en} } @article{GasparyanPoghossianVitusevichetal.2011, author = {Gasparyan, Ferdinand V. and Poghossian, Arshak and Vitusevich, Svetlana A. and Petrychuk, Mykhaylo V. and Sydoruk, Viktor A. and Siqueira, Jos{\´e} R. Jr. and Oliveira, Osvaldo N. Jr. and Offenh{\"a}usser, Andreas and Sch{\"o}ning, Michael Josef}, title = {Low-Frequency Noise in Field-Effect Devices Functionalized With Dendrimer/Carbon-Nanotube Multilayers}, series = {IEEE Sensors Journal. 11 (2011), H. 1}, journal = {IEEE Sensors Journal. 11 (2011), H. 1}, publisher = {IEEE}, address = {New York}, isbn = {1530-437X}, pages = {142 -- 149}, year = {2011}, language = {en} } @article{GunGutkinLevetal.2011, author = {Gun, Jenny and Gutkin, Vitaly and Lev, Ovadia and Boyen, Hans-Gerd and Saitner, Marc and Wagner, Patrick and Olieslaeger, Marc D´ and Abouzar, Maryam H. and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Tracing gold nanoparticle charge by electrolyte-insulator-semiconductor devices}, series = {Journal of Physical Chemistry C. 115 (2011), H. 11}, journal = {Journal of Physical Chemistry C. 115 (2011), H. 11}, publisher = {American Cemical Society}, address = {Washington, DC}, isbn = {1932-7455}, pages = {4439 -- 4445}, year = {2011}, language = {en} } @article{AbouzarWernerSchoeningetal.2011, author = {Abouzar, Maryam H. and Werner, Moritz and Sch{\"o}ning, Michael Josef and Poghossian, Arshak}, title = {Capacitance-voltage and impedance-spectroscopy characteristics of nanoplate EISOI capacitors}, series = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, journal = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, publisher = {Wiley-VCH}, address = {Berlin}, isbn = {1862-6319}, pages = {1327 -- 1332}, year = {2011}, language = {en} } @article{PoghossianMalzahnAbouzaretal.2011, author = {Poghossian, Arshak and Malzahn, K. and Abouzar, Maryam H. and Mehndiratta, P. and Katz, E. and Sch{\"o}ning, Michael Josef}, title = {Integration of biomolecular logic gates with field-effect transducers}, series = {Electrochimica Acta. 56 (2011), H. 26}, journal = {Electrochimica Acta. 56 (2011), H. 26}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {0013-4686}, pages = {9661 -- 9665}, year = {2011}, language = {en} } @article{BaeckerDellePoghossianetal.2011, author = {B{\"a}cker, Matthias and Delle, L. and Poghossian, Arshak and Biselli, Manfred and Zang, Werner and Wagner, P. and Sch{\"o}ning, Michael Josef}, title = {Electrochemical sensor array for bioprocess monitoring}, series = {Electrochimica Acta (2011)}, volume = {56}, journal = {Electrochimica Acta (2011)}, number = {26}, publisher = {Elsevier}, address = {Amsterdam}, pages = {9673 -- 9678}, year = {2011}, language = {en} } @inproceedings{HuckBaeckerPoghossianetal.2011, author = {Huck, Christina and B{\"a}cker, Matthias and Poghossian, Arshak and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Bifunktionaler Sensorchip f{\"u}r den Nachweis von Gel{\"o}stwasserstoff}, isbn = {978-3942710-53-4}, doi = {10.5162/10dss2011/16.10}, pages = {325 -- 328}, year = {2011}, language = {de} } @article{HuckJollyWagneretal.2011, author = {Huck, Christina and Jolly, Christina and Wagner, Patrick and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {One-chip integrated dual amperometric/field-effect sensor for the detection of dissolved hydrogen}, series = {Procedia Engineering. 25 (2011)}, journal = {Procedia Engineering. 25 (2011)}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1877-7058}, pages = {1161 -- 1164}, year = {2011}, language = {en} } @article{SiqueiraMakiPaulovichetal.2010, author = {Siqueira, Jose R. and Maki, Rafael M. and Paulovich, Fernando V. and Werner, Frederik and Poghossian, Arshak and Oliveira, Maria C. F. de and Zucolotto, Valtencir and Oliveira, Osvaldo N. Jr. and Sch{\"o}ning, Michael Josef}, title = {Use of information visualization methods eliminating cross talk in multiple sensing units investigated for a light-addressable potentiometric sensor}, series = {Analytical Chemistry}, volume = {82}, journal = {Analytical Chemistry}, number = {1}, publisher = {ACS Publications}, address = {Washington}, issn = {0003-2700}, doi = {10.1021/ac9024076}, pages = {61 -- 65}, year = {2010}, abstract = {The integration of nanostructured films containing biomolecules and silicon-based technologies is a promising direction for reaching miniaturized biosensors that exhibit high sensitivity and selectivity. A challenge, however, is to avoid cross talk among sensing units in an array with multiple sensors located on a small area. In this letter, we describe an array of 16 sensing units of a light-addressable potentiometric sensor (LAPS), which was made with layer-by-layer (LbL) films of a poly(amidomine) dendrimer (PAMAM) and single-walled carbon nanotubes (SWNTs), coated with a layer of the enzyme penicillinase. A visual inspection of the data from constant-current measurements with liquid samples containing distinct concentrations of penicillin, glucose, or a buffer indicated a possible cross talk between units that contained penicillinase and those that did not. With the use of multidimensional data projection techniques, normally employed in information visualization methods, we managed to distinguish the results from the modified LAPS, even in cases where the units were adjacent to each other. Furthermore, the plots generated with the interactive document map (IDMAP) projection technique enabled the distinction of the different concentrations of penicillin, from 5 mmol L-1 down to 0.5 mmol L-1. Data visualization also confirmed the enhanced performance of the sensing units containing carbon nanotubes, consistent with the analysis of results for LAPS sensors. The use of visual analytics, as with projection methods, may be essential to handle a large amount of data generated in multiple sensor arrays to achieve high performance in miniaturized systems}, language = {en} } @inproceedings{PoghossianWagnerSchoening2010, author = {Poghossian, Arshak and Wagner, Holger and Sch{\"o}ning, Michael Josef}, title = {Automatisiertes „wafer level"-Testsystem zur Charakterisierung von siliziumbasierten Chemo- und Biosensoren}, series = {Tagungsband: Sensoren und Messsysteme 2010}, booktitle = {Tagungsband: Sensoren und Messsysteme 2010}, publisher = {VDE Verlag}, address = {Berlin}, isbn = {978-3-8007-3260-9}, pages = {89 -- 92}, year = {2010}, abstract = {Es wurde ein automatisiertes, computerunterst{\"u}tztes Testsystem f{\"u}r die Funktionspr{\"u}fung und Charakterisierung von (bio-)chemischen Sensoren auf Waferebene entwickelt und in einen konventionellen Spitzenmessplatz integriert. Das System erm{\"o}glicht die Charakterisierung und Identifizierung „funktionstauglicher" Sensoren bereits auf Waferebene zwischen den einzelnen Herstellungsschritten, wodurch weitere, bisher {\"u}bliche Verarbeitungsschritte wie das Fixieren, Bonden und Verkapseln f{\"u}r die defekten oder nicht funktionstauglichen Sensorstrukturen entf{\"a}llt. Außerdem bietet eine speziell entworfene miniaturisierte Durchflussmesszelle die M{\"o}glichkeit, bereits auf Waferlevel die Sensitivit{\"a}t, Drift, Hysterese und Ansprechzeit der (bio-)chemischen Sensoren zu charakterisieren. Das System wurde exemplarisch mit kapazitiven, pH-sensitiven EIS- (Elektrolyt-Isolator-Silizium) Strukturen und ISFET- (ionensensitiver Feldeffekttransistor) Strukturen mit verschiedenen Geometrien und Gate-Layouts getestet.}, language = {de} }