@book{ButenwegHoffmeisterHoltschoppenetal.2020, author = {Butenweg, Christoph and Hoffmeister, Benno and Holtschoppen, Britta and Klinkel, Sven and Rosin, Julia and Schmitt, Timo}, title = {Seismic design of industrial facilities 2020: proceedings of the 2nd International Conference on Seismic Design of Industrial Facilities (SeDIF-Conference)}, publisher = {Apprimus Verlag}, address = {Aachen}, isbn = {978-3-86359-729-0}, pages = {524 Seiten}, year = {2020}, language = {en} } @book{KlinkelButenwegLinetal.2014, author = {Klinkel, Sven and Butenweg, Christoph and Lin, Gao and Holtschoppen, Britta}, title = {Seismic design of industrial facilities : Proceedings of the International Conference on Seismic Design of Industrial Facilities (SeDIF) / Sven Klinkel, Christoph Butenweg, Gao Lin, Britta Holtschoppen Editors}, publisher = {Springer Vieweg}, address = {Wiesbaden}, organization = {International Conference on Seismic Design of Industrial Facilities }, isbn = {978-3-658-02809-1 (Print) ; 978-365-80281-0-7 (E-Book)}, doi = {10.1007/978-3-658-02810-7}, pages = {XIII, 450 S.}, year = {2014}, language = {en} } @article{MykoniouButenwegHoltschoppenetal.2016, author = {Mykoniou, Konstantin and Butenweg, Christoph and Holtschoppen, Britta and Klinkel, Sven}, title = {Seismic response analysis of adjacent liquid-storage tanks}, series = {Earthquake engineering and structural dynamics}, volume = {45}, journal = {Earthquake engineering and structural dynamics}, number = {11}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1096-9845 (E-Journal); 0098-8847 (Print)}, doi = {10.1002/eqe.2726}, pages = {1779 -- 1796}, year = {2016}, abstract = {A refined substructure technique in the frequency domain is developed, which permits consideration of the interaction effects among adjacent containers through the supporting deformable soil medium. The tank-liquid systems are represented by means of mechanical models, whereas discrete springs and dashpots stand for the soil beneath the foundations. The proposed model is employed to assess the responses of adjacent circular, cylindrical tanks for harmonic and seismic excitations over wide range of tank proportions and soil conditions. The influence of the number, spatial arrangement of the containers and their distance on the overall system's behavior is addressed. The results indicate that the cross-interaction effects can substantially alter the impulsive components of response of each individual element in a tank farm. The degree of this impact is primarily controlled by the tank proportions and the proximity of the predominant natural frequencies of the shell-liquid-soil systems and the input seismic motion. The group effects should be not a priori disregarded, unless the tanks are founded on shallow soil deposit overlying very stiff material or bedrock.}, language = {en} }