@article{TemizArtmannKurulgandemirciFıratetal.2021, author = {Temiz Artmann, Ayseg{\"u}l and Kurulgan demirci, Eylem and F{\i}rat, Ipek Seda and Oflaz, Hakan and Artmann, Gerhard}, title = {Recombinant activated protein C (rhAPC) affects lipopolysaccharide-induced mechanical compliance changes and beat frequency of mESC-derived cardiomyocyte monolayers}, series = {SHOCK}, journal = {SHOCK}, publisher = {Wolters Kluwer}, address = {K{\"o}ln}, issn = {1540-0514}, doi = {10.1097/SHK.0000000000001845}, year = {2021}, language = {en} } @article{UysalCreutzFiratetal.2022, author = {Uysal, Karya and Creutz, Till and Firat, Ipek Seda and Artmann, Gerhard and Teusch, Nicole and Temiz Artmann, Ayseg{\"u}l}, title = {Bio-functionalized ultra-thin, large-area and waterproof silicone membranes for biomechanical cellular loading and compliance experiments}, series = {Polymers}, volume = {14}, journal = {Polymers}, number = {11}, publisher = {MDPI}, address = {Basel}, issn = {2073-4360}, pages = {2213}, year = {2022}, abstract = {Biocompatibility, flexibility and durability make polydimethylsiloxane (PDMS) membranes top candidates in biomedical applications. CellDrum technology uses large area, <10 µm thin membranes as mechanical stress sensors of thin cell layers. For this to be successful, the properties (thickness, temperature, dust, wrinkles, etc.) must be precisely controlled. The following parameters of membrane fabrication by means of the Floating-on-Water (FoW) method were investigated: (1) PDMS volume, (2) ambient temperature, (3) membrane deflection and (4) membrane mechanical compliance. Significant differences were found between all PDMS volumes and thicknesses tested (p < 0.01). They also differed from the calculated values. At room temperatures between 22 and 26 °C, significant differences in average thickness values were found, as well as a continuous decrease in thicknesses within a 4 °C temperature elevation. No correlation was found between the membrane thickness groups (between 3-4 µm) in terms of deflection and compliance. We successfully present a fabrication method for thin bio-functionalized membranes in conjunction with a four-step quality management system. The results highlight the importance of tight regulation of production parameters through quality control. The use of membranes described here could also become the basis for material testing on thin, viscous layers such as polymers, dyes and adhesives, which goes far beyond biological applications.}, language = {en} } @article{BayerTemizArtmannDigeletal.2020, author = {Bayer, Robin and Temiz Artmann, Ayseg{\"u}l and Digel, Ilya and Falkenstein, Julia and Artmann, Gerhard and Creutz, Till and Hescheler, J{\"u}rgen}, title = {Mechano-pharmacological testing of L-Type Ca²⁺ channel modulators via human vascular celldrum model}, series = {Cellular Physiology and Biochemistry}, volume = {54}, journal = {Cellular Physiology and Biochemistry}, publisher = {Cell Physiol Biochem Press}, address = {D{\"u}sseldorf}, issn = {1421-9778}, doi = {10.33594/000000225}, pages = {371 -- 383}, year = {2020}, abstract = {Background/Aims: This study aimed to establish a precise and well-defined working model, assessing pharmaceutical effects on vascular smooth muscle cell monolayer in-vitro. It describes various analysis techniques to determine the most suitable to measure the biomechanical impact of vasoactive agents by using CellDrum technology. Methods: The so-called CellDrum technology was applied to analyse the biomechanical properties of confluent human aorta muscle cells (haSMC) in monolayer. The cell generated tensions deviations in the range of a few N/m² are evaluated by the CellDrum technology. This study focuses on the dilative and contractive effects of L-type Ca²⁺ channel agonists and antagonists, respectively. We analyzed the effects of Bay K8644, nifedipine and verapamil. Three different measurement modes were developed and applied to determine the most appropriate analysis technique for the study purpose. These three operation modes are called, particular time mode" (PTM), "long term mode" (LTM) and "real-time mode" (RTM). Results: It was possible to quantify the biomechanical response of haSMCs to the addition of vasoactive agents using CellDrum technology. Due to the supplementation of 100nM Bay K8644, the tension increased approximately 10.6\% from initial tension maximum, whereas, the treatment with nifedipine and verapamil caused a significant decrease in cellular tension: 10nM nifedipine decreased the biomechanical stress around 6,5\% and 50nM verapamil by 2,8\%, compared to the initial tension maximum. Additionally, all tested measurement modes provide similar results while focusing on different analysis parameters. Conclusion: The CellDrum technology allows highly sensitive biomechanical stress measurements of cultured haSMC monolayers. The mechanical stress responses evoked by the application of vasoactive calcium channel modulators were quantified functionally (N/m²). All tested operation modes resulted in equal findings, whereas each mode features operation-related data analysis.}, language = {en} } @article{UysalFiratCreutzetal.2022, author = {Uysal, Karya and Firat, Ipek Serat and Creutz, Till and Aydin, Inci Cansu and Artmann, Gerhard and Teusch, Nicole and Temiz Artmann, Ayseg{\"u}l}, title = {A novel in vitro wound healing assay using free-standing, ultra-thin PDMS membranes}, series = {membranes}, volume = {2023}, journal = {membranes}, number = {13(1)}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/membranes13010022}, pages = {Artikel 22}, year = {2022}, abstract = {Advances in polymer science have significantly increased polymer applications in life sciences. We report the use of free-standing, ultra-thin polydimethylsiloxane (PDMS) membranes, called CellDrum, as cell culture substrates for an in vitro wound model. Dermal fibroblast monolayers from 28- and 88-year-old donors were cultured on CellDrums. By using stainless steel balls, circular cell-free areas were created in the cell layer (wounding). Sinusoidal strain of 1 Hz, 5\% strain, was applied to membranes for 30 min in 4 sessions. The gap circumference and closure rate of un-stretched samples (controls) and stretched samples were monitored over 4 days to investigate the effects of donor age and mechanical strain on wound closure. A significant decrease in gap circumference and an increase in gap closure rate were observed in trained samples from younger donors and control samples from older donors. In contrast, a significant decrease in gap closure rate and an increase in wound circumference were observed in the trained samples from older donors. Through these results, we propose the model of a cell monolayer on stretchable CellDrums as a practical tool for wound healing research. The combination of biomechanical cell loading in conjunction with analyses such as gene/protein expression seems promising beyond the scope published here.}, language = {en} } @article{AkimbekovZhubanovaMansurovetal.2010, author = {Akimbekov, N. Sh. and Zhubanova, A. A. and Mansurov, Z. A. and Digel, Ilya and Artmann, Gerhard and Temiz Artmann, Ayseg{\"u}l}, title = {Use of Carbonized Rise Shell for the local treatment of wounds}, series = {Eurasian ChemTech Journal}, volume = {12}, journal = {Eurasian ChemTech Journal}, number = {2}, publisher = {Institute of Combustion Problems}, address = {Almaty}, issn = {2522-4867}, doi = {10.18321/ectj35}, pages = {133 -- 138}, year = {2010}, abstract = {On the model of musculocutaneous wound in rats, the effect of applicative sorption by carbonized rise shell (CRS) on the healing of festering wound was studied. It has been shown, that cytological changes end with rapid scar formation. The use of CRS at the period of severe purulent wound contributes to its favorable course, prevents the development of complications of the animals from sepsis.}, language = {en} } @article{KozhalakovaZhubanovaMansurovetal.2010, author = {Kozhalakova, A. A. and Zhubanova, Azhar A. and Mansurov, Z. A. and Digel, Ilya and Tazhibayeva, S. M. and Artmann, Gerhard and Temiz Artmann, Ayseg{\"u}l}, title = {Adsorption of bacterial lipopolysaccharides on carbonized rice shell}, series = {Science of Central Asia (2010)}, journal = {Science of Central Asia (2010)}, pages = {50 -- 54}, year = {2010}, language = {en} } @article{KurzLinderTrzewiketal.2010, author = {Kurz, R. and Linder, Peter and Trzewik, J{\"u}rgen and R{\"u}ffer, M. and Artmann, Gerhard and Digel, Ilya and Rothermel, A. and Robitzki, A. and Temiz Artmann, Ayseg{\"u}l}, title = {Contractile tension and beating rates of self-exciting monolayers and 3D-tissue constructs of neonatal rat cardiomyocytes}, series = {Medical and Biological Engineering and Computing}, volume = {48}, journal = {Medical and Biological Engineering and Computing}, number = {1}, publisher = {Springer Nature}, address = {Cham}, issn = {1741-0444}, doi = {10.1007/s11517-009-0552-y}, pages = {59 -- 65}, year = {2010}, abstract = {The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocytes. Cells were grown either within flexible, circular collagen gels or as monolayer on top of respective 1-mum thin silicone membranes. Membrane and cells were bulged outwards by air pressure. This biaxial strain distribution is rather similar the beating, blood-filled heart. The setup allowed presetting the mechanical residual stress level externally by adjusting the centre deflection, thus, mimicking hypertension in vitro. Tension was measured as oscillating differential pressure change between chamber and environment. A 0.5-mm thick collagen-cardiac myocyte tissue construct induced after 2 days of culturing (initial cell density 2 x 10(4) cells/ml), a mechanical tension of 1.62 +/- 0.17 microN/mm(2). Mechanical load is an important growth regulator in the developing heart, and the orientation and alignment of cardiomyocytes is stress sensitive. Therefore, it was necessary to develop the CellDrum technology with its biaxial stress-strain distribution and defined mechanical boundary conditions. Cells were exposed to strain in two directions, radially and circumferentially, which is similar to biaxial loading in real heart tissues. Thus, from a biomechanical point of view, the system is preferable to previous setups based on uniaxial stretching.}, language = {en} } @article{LiShiLandsmannetal.1998, author = {Li, Anlan and Shi, Young de and Landsmann, B. and Schankowski-Bouvier, P. and Dikta, Gerhard and Bauer, U. and Artmann, Gerhard}, title = {Hemorheology and walking distance of Peripheral Arterial Occlusive Disease patients during treatment with Ginkgo-biloba extract}, series = {Acta Pharmacologica Sinica = ZHONGUO YAOLI XUEBAO. 19 (1998), H. 5}, journal = {Acta Pharmacologica Sinica = ZHONGUO YAOLI XUEBAO. 19 (1998), H. 5}, isbn = {1745-7254}, pages = {417 -- 421}, year = {1998}, language = {en} } @article{ZhubanovaDigelNojimaetal.2007, author = {Zhubanova, Azhar A. and Digel, Ilya and Nojima, H. and Artmann, Gerhard}, title = {The use of bactericidal effects of cluster ions generated by plasma in medical biotechnology}, year = {2007}, abstract = {The most of conventional methods of air purification use the power of a fan to draw in air and pass it through a filter. The problem of bacterial contamination of inner parts of such a type of air conditioners in some cases draws attention towards alternative air-cleaning systems. Some manufacturers offer to use the ozone's bactericidal and deodorizing effects, but the wide spreading of such systems is restricted by the fact that toxic effects of ozone in respect of human beings are well known. In 2000 Sharp Inc. introduced "Plasma Cluster Ions (PCI)" air purification technology, which uses plasma discharge to generate cluster ions (I 0-14 ). This technology has been developed for those customers that are conscious about health and hygiene. In our experiments, we focused on some principal aspects of plasma-generated ions application - time-dependency and irreversibility of bactericidal action, spatial and kinetic characteristics of emitted cluster particles, their chemical targets in the microbial cells.}, subject = {Clusterion}, language = {en} } @inproceedings{DachwaldXuFeldmannetal.2011, author = {Dachwald, Bernd and Xu, Changsheng and Feldmann, Marco and Plescher, Engelbert and Digel, Ilya and Artmann, Gerhard}, title = {Development and testing of a subsurface probe for detection of life in deep ice : [abstract]}, year = {2011}, abstract = {We present the novel concept of a combined drilling and melting probe for subsurface ice research. This probe, named "IceMole", is currently developed, built, and tested at the FH Aachen University of Applied Sciences' Astronautical Laboratory. Here, we describe its first prototype design and report the results of its field tests on the Swiss Morteratsch glacier. Although the IceMole design is currently adapted to terrestrial glaciers and ice shields, it may later be modified for the subsurface in-situ investigation of extraterrestrial ice, e.g., on Mars, Europa, and Enceladus. If life exists on those bodies, it may be present in the ice (as life can also be found in the deep ice of Earth).}, subject = {Eisschicht}, language = {en} } @inproceedings{BassamDigelArtmann2009, author = {Bassam, Rasha and Digel, Ilya and Artmann, Gerhard}, title = {Effect of nitric oxide on protein thermal stability : [abstract]}, year = {2009}, abstract = {As a deduction from these results, we can conclude that proteins mainly in vitro, denaturate totally at a temperature between 57°C -62°C, and they also affected by NO and different ions types. In which mainly, NO cause earlier protein denaturation, which means that, NO has a destabilizing effect on proteins, and also different ions will alter the protein denaturation in which, some ions will cause earlier protein denaturation while others not.}, subject = {Stickstoffmonoxid}, language = {en} } @inproceedings{DigelDachwaldArtmannetal.2009, author = {Digel, Ilya and Dachwald, Bernd and Artmann, Gerhard and Linder, Peter and Funke, O.}, title = {A concept of a probe for particle analysis and life detection in icy environments}, year = {2009}, abstract = {A melting probe equipped with autofluorescence-based detection system combined with a light scattering unit, and, optionally, with a microarray chip would be ideally suited to probe icy environments like Europa's ice layer as well as the polar ice layers of Earth and Mars for recent and extinct live.}, subject = {Sonde}, language = {en} } @inproceedings{StadlerEmbsZerlinetal.2007, author = {Stadler, Andreas M. and Embs, Jan P. and Zerlin, Kay and Digel, Ilya and Artmann, Gerhard and Zaccai, Joe and B{\"u}ldt, Georg}, title = {Temperature transitions of hemoglobin and cytosolic water diffusion in human red blood cells : [poster]}, year = {2007}, abstract = {Background Hemoglobin interactions in red blood cells Hemoglobin dynamics in human red blood cells Diffusion of H2O in red blood cells}, subject = {Erythrozyt}, language = {en} } @article{ArtmannTrzewikAtes2002, author = {Artmann, Gerhard and Trzewik, J{\"u}rgen and Ates, M.}, title = {A novel method to quantify mechanical tension in cell monolayers. Trzewik, J{\"u}rgen; Ates, M., Artmann, Gerhard Michael}, series = {Biomedizinische Technik. 47 (2002), H. Suppl. 1. Pt. 1}, journal = {Biomedizinische Technik. 47 (2002), H. Suppl. 1. Pt. 1}, isbn = {0013-5585}, pages = {379 -- 381}, year = {2002}, language = {en} } @article{MaggakisKelemenBiselliArtmann2002, author = {Maggakis-Kelemen, Christina and Biselli, Manfred and Artmann, Gerhard}, title = {Determination of the elastic shear modulus of cultured human red blood cells}, series = {Biomedizinische Technik. 47 (2002), H. Suppl. 1 Pt. 1}, journal = {Biomedizinische Technik. 47 (2002), H. Suppl. 1 Pt. 1}, isbn = {0013-5585}, pages = {106 -- 109}, year = {2002}, language = {en} } @article{ArtmannZhouStacheBuettneretal.2002, author = {Artmann, Gerhard and Zhou-Stache, J. and Buettner, R. and Mittermayer, C. [u.a.]}, title = {Inhibition of TNF-alpha induced cell death in HUVEC and Jurkat cells by protocatechuic acid. Zhou-Stache, J.; Buettner, R.; Artmann, Gerhard Michael; Mittermayer, C.; Bosserhoff, A. K.}, series = {Medical and Biological Engineering and Computing. 40 (2002), H. 6}, journal = {Medical and Biological Engineering and Computing. 40 (2002), H. 6}, isbn = {0140-0118}, pages = {698 -- 703}, year = {2002}, language = {en} } @article{ArtmannTrzewikMallipattuetal.2001, author = {Artmann, Gerhard and Trzewik, J{\"u}rgen and Mallipattu, S. K. and Delano, F. A. [u.a.]}, title = {Evidence for a second valve system in Lymphatics: Endothelial Microvalves. Trzewik, J{\"u}rgen; Mallipattu, S. K.; Artmann, Gerhard Michael; Delano, F. A.; Schmid-Schonbein, G. W}, series = {The FASEB Journal. 15 (2001)}, journal = {The FASEB Journal. 15 (2001)}, isbn = {1530-6860}, pages = {1711 -- 1717}, year = {2001}, language = {en} } @article{ArtmannBaeumlerVoigtetal.2000, author = {Artmann, Gerhard and B{\"a}umler, H. and Voigt, A. and Mitl{\"o}hner, R. [u.a.]}, title = {Plastic behaviour of polyelectrolyte microcapsules derived from colloid templates. B{\"a}umler, H., Artmann, Gerhard Michael; Voigt, A., Mitl{\"o}hner, R., Neu, B., Kiesewetter, H.}, series = {Journal of Microencapsulation. 17 (2000), H. 5}, journal = {Journal of Microencapsulation. 17 (2000), H. 5}, isbn = {1464-5246}, pages = {651 -- 655}, year = {2000}, language = {en} } @article{ArtmannGorbatenkovaPanasenko2000, author = {Artmann, Gerhard and Gorbatenkova, E. A. and Panasenko, O. M.}, title = {Hypochlorous acid and human blood low density lipoproteins modified by hypochlorous acid increase erythrocyte adhesion to endothelial cells. Gorbatenkova, E. A.; Artmann, Gerhard Michael; Panasenko, O. M.}, series = {Membrane and cell biology. 13 (2000), H. 4}, journal = {Membrane and cell biology. 13 (2000), H. 4}, isbn = {1023-6597}, pages = {537 -- 546}, year = {2000}, language = {en} } @article{ArtmannKelemenChien2001, author = {Artmann, Gerhard and Kelemen, C. and Chien, S.}, title = {Temperature transition of human hemoglobin at body temperature: effects of calcium. Kelemen, C.; Chien, S.; Artmann, Gerhard Michael}, series = {Biophysical journal. 80 (2001), H. 6}, journal = {Biophysical journal. 80 (2001), H. 6}, isbn = {1542-0086}, pages = {2622 -- 2630}, year = {2001}, language = {en} } @article{ArtmannHueckHollwegetal.2000, author = {Artmann, Gerhard and Hueck, I. S. and Hollweg, H. G. and Schmid-Sch{\"o}nbein, G. W.}, title = {Chlorpromazine modulates the Morphological Macro- and Microstructure of Endothelial Cells. Hueck, I. S.; Hollweg, H. G.; Schmid-Sch{\"o}nbein, G. W.; Artmann, Gerhard Michael}, series = {American Journal of Physiology. Cell Physiology. 278 (2000), H. 5}, journal = {American Journal of Physiology. Cell Physiology. 278 (2000), H. 5}, isbn = {1522-1563}, pages = {873 -- 878}, year = {2000}, language = {en} } @article{ArtmannLiSeipeltetal.1999, author = {Artmann, Gerhard and Li, Anlan and Seipelt, H. and M{\"u}ller, C. [u.a.]}, title = {Effects of salicylic acid derivatives on red blood cell membranes. Li, Anlan; Seipelt, H.; M{\"u}ller, C.;Shi, Yong de; Artmann, Gerhard Michael}, series = {Pharmacology and Toxicology. 85 (1999)}, journal = {Pharmacology and Toxicology. 85 (1999)}, isbn = {0902-9938}, pages = {206 -- 211}, year = {1999}, language = {en} } @article{ArtmannHovavGoldfarbetal.1999, author = {Artmann, Gerhard and Hovav, T. and Goldfarb, A. and Yedgar, S. [u.a.]}, title = {Enhanced adherence of beta-thalassaemic erythrocytes to endothelial cells. Hovav, T., Goldfarb, A.; Artmann, Gerhard Michael, Yedgar, S.; Barstein, G.}, series = {British Journal of Haematology. 106 (1999), H. 1}, journal = {British Journal of Haematology. 106 (1999), H. 1}, isbn = {1365-2141}, pages = {178 -- 181}, year = {1999}, language = {en} } @article{ArtmannKelemenPorstetal.1998, author = {Artmann, Gerhard and Kelemen, Christina and Porst, Dariusz and B{\"u}ldt, G. [u.a.]}, title = {Temperature transitions of protein properties in human red blood cells. Artmann, Gerhard Michael, Kelemen, Christina; Porst, D.; B{\"u}ldt, G.; Chien, S.}, series = {Biophysical Journal. 75 (1998), H. 6}, journal = {Biophysical Journal. 75 (1998), H. 6}, isbn = {1542-0086}, pages = {3179 -- 3183}, year = {1998}, language = {en} } @article{ArtmannShiAgostietal.1998, author = {Artmann, Gerhard and Shi, Young de and Agosti, R. and Longhini, E.}, title = {A modified casson equation to characterize blood rheology for hypertension. Shi, Young de; Artmann, Gerhard Michael; Agosti, R.; Longhini, E.}, series = {Clinical Hemorheology Microcirculation. 19 (1998), H. 2}, journal = {Clinical Hemorheology Microcirculation. 19 (1998), H. 2}, isbn = {1386-0291}, pages = {115 -- 127}, year = {1998}, language = {en} } @article{ArtmannSchikarsky1993, author = {Artmann, Gerhard and Schikarsky, C.}, title = {Ginkgo Biloba extract (EGb 761) protects red blood cells from oxidative damage. Artmann, Gerhard Michael; Schikarsky, C.}, series = {Clinical Hemorheology. 13 (1993), H. 4}, journal = {Clinical Hemorheology. 13 (1993), H. 4}, isbn = {0271-5198}, pages = {529 -- 539}, year = {1993}, language = {en} } @article{Artmann1986, author = {Artmann, Gerhard}, title = {A microscopic photometric method for measuring erythrocyte deformability. Artmann, Gerhard Michael}, series = {Clinical Hemorheology. 6 (1986)}, journal = {Clinical Hemorheology. 6 (1986)}, isbn = {0271-5198}, pages = {617 -- 627}, year = {1986}, language = {en} } @article{ArtmannSchmidSchoenbeinGrebeetal.1988, author = {Artmann, Gerhard and Schmid-Sch{\"o}nbein, H. and Grebe, R. and Teitel, P. [u.a.]}, title = {Restoration of Microsieve Filterability of Human Red Cells After Exposure to Hyperosmolarity and Lactazidosis: Effect of Vinpocetine. Schmid-Sch{\"o}nbein, H.; Grebe, R.; Teitel, P.; Artmann, Gerhard Michael, Eschweiler, H.; Schr{\"o}der, Susanne}, series = {Drug Development Research. 14 (1988), H. 3-4}, journal = {Drug Development Research. 14 (1988), H. 3-4}, isbn = {1098-2299}, pages = {205 -- 211}, year = {1988}, language = {en} } @article{ArtmannSchmidSchoenbeinSchroederetal.1988, author = {Artmann, Gerhard and Schmid-Sch{\"o}nbein, H. and Schr{\"o}der, Susanne and Grebe, R. [u.a.]}, title = {Influence of Moxaverine-HCL on Membrane Curvature and Microsieve Filterability of Red Cells after Exposure to Hyperosmolarity and Lactacidosis. Schmid-Sch{\"o}nbein, H.; Schr{\"o}der, Susanne; Grebe, R.; Artmann, Gerhard Michael, Eschweiler, H; Teitel, P.}, series = {Arzneimittelforschung. 38 (1988), H. 5}, journal = {Arzneimittelforschung. 38 (1988), H. 5}, isbn = {0004-4172}, pages = {710 -- 716}, year = {1988}, language = {en} } @article{ArtmannZang1990, author = {Artmann, Gerhard and Zang, Werner}, title = {Fully automatic measurement of rheologic parameters of red blood cells = Laborautomat zur Messung mechanischer Eigenschaften roter Blutzellen}, series = {Biomedizinische Technik = Biomedical engineering. 35 (1990), H. Suppl. 3}, journal = {Biomedizinische Technik = Biomedical engineering. 35 (1990), H. Suppl. 3}, isbn = {0013-5585}, pages = {94 -- 96}, year = {1990}, language = {en} } @article{ArtmannSungHornetal.1997, author = {Artmann, Gerhard and Sung, K.-L. Paul and Horn, Thomas and Whittemore, Darren [u.a.]}, title = {Micropipette aspiration of human erythrocytes induces echinocytes via membrane phospholipid translocation. Artmann, Gerhard Michael; Sung, K.-L. Paul; Horn, Thomas; Whittemore, Darren; Norwich, Gerald; Chien, Shu}, series = {Biophysical journal. 72 (1997), H. 3}, journal = {Biophysical journal. 72 (1997), H. 3}, isbn = {1542-0086}, pages = {1434 -- 1441}, year = {1997}, language = {en} } @article{ArtmannLiZiemeretal.1996, author = {Artmann, Gerhard and Li, Anlan and Ziemer, J. and Schneider, G. [u.a.]}, title = {A photometric method to analyze induced erythrocyte shape changes. Artmann, Gerhard Michael; Li, Anlan; Ziemer, J.; Schneider, G.; Sahm, U.: ; Ziemer, J.; Schneider, G.; Sahm, U.}, series = {Biorheology. 33 (1996), H. 3}, journal = {Biorheology. 33 (1996), H. 3}, isbn = {0006-355x}, pages = {251 -- 265}, year = {1996}, language = {en} } @article{Artmann1996, author = {Artmann, Gerhard}, title = {2nd International Conference on Medical Biorheology (ICMB). Shanghai, China, September 13-15, 1995. Shi, Young de, Artmann, Gerhard Michael, Meiselman, Herbert J.}, series = {Biorheology. 33 (1996), H. 6}, journal = {Biorheology. 33 (1996), H. 6}, isbn = {0006-355x}, pages = {505 -- 507}, year = {1996}, language = {en} } @article{Artmann1995, author = {Artmann, Gerhard}, title = {Microscopic photometric quantification of stiffness and relaxation time of red blood cells in a flow chamber. Artmann, Gerhard Michael}, series = {Biorheology. 32 (1995), H. 5}, journal = {Biorheology. 32 (1995), H. 5}, isbn = {0006-355x}, pages = {553 -- 570}, year = {1995}, language = {en} } @article{ArtmannLi1994, author = {Artmann, Gerhard and Li, Anlan}, title = {Dihydroergocryptine maintains erythrocyte fluidity in acidotic and hyperosmolar suspensions modelling hypoxic and ischemic microcirculation. Li, Anlan; Artmann, Gerhard Michael}, series = {Clinical Hemorheology. 15 (1994), H. 2}, journal = {Clinical Hemorheology. 15 (1994), H. 2}, isbn = {0271-5198}, pages = {133 -- 146}, year = {1994}, language = {en} } @article{ArtmannSchmidSchoenbein1987, author = {Artmann, Gerhard and Schmid-Sch{\"o}nbein, H.}, title = {The microscope-photometrical-monolayer-technique- a new principle for analyzing the distribution of rheological responses in pathological and experimentally modified red cell populations. Artmann, Gerhard Michael; Schmid-Sch{\"o}nbein, H.}, series = {Microcirculation, an update : proceedings of the Fourth World Congress for Microcirculation, Tokyo, Japan, July 26-30, 1987}, journal = {Microcirculation, an update : proceedings of the Fourth World Congress for Microcirculation, Tokyo, Japan, July 26-30, 1987}, publisher = {Excerpta Medica}, address = {Amsterdam [u.a.]}, isbn = {0444809511}, pages = {475 -- 477}, year = {1987}, language = {en} } @article{ArtmannTeitelSchmidSchoenbein1987, author = {Artmann, Gerhard and Teitel, P. and Schmid-Sch{\"o}nbein, H.}, title = {Variable rheologische Antwort der Erythrozyten auf den Einfluß von Xantinderivaten (Coffein): Experimentelle Differenzierung von "Responders" und "Nonresponders"}, series = {11. Jahrestagung der Gesellschaft f{\"u}r Mikrozirkulation}, journal = {11. Jahrestagung der Gesellschaft f{\"u}r Mikrozirkulation}, publisher = {Karger [u.a.]}, address = {Basel [u.a.]}, pages = {100 -- 105}, year = {1987}, language = {de} } @article{ArtmannGrebeHomrighausenetal.1988, author = {Artmann, Gerhard and Grebe, R. and Homrighausen, A. and Wolff, H. and [u.a.],}, title = {Response of normal and diabetic erythrocytes to membrane deformation by chemical and mechanical forces. Artmann, Gerhard Michael; Grebe, R.; Homrighausen, A.; Wolff, H.; Teitel, P.; Schmid-Sch{\"o}nbein, H.}, series = {12. Jahrestagung der Gesellschaft f{\"u}r Mikrozirkulation}, journal = {12. Jahrestagung der Gesellschaft f{\"u}r Mikrozirkulation}, publisher = {Karger [u.a.]}, address = {Basel [u.a.]}, pages = {196 -- 200}, year = {1988}, language = {en} } @article{ArtmannKellerHaasetal.1991, author = {Artmann, Gerhard and Keller, U. and Haas, J. and Amort, U. and Zang, Werner and Karschies, S.}, title = {Technik und ausgew{\"a}hlte Applikationen eines Membranbioassays roter Blutzellen}, series = {Biomedizinische Technik = Biomedical engineering. 36 (1991)}, volume = {36}, journal = {Biomedizinische Technik = Biomedical engineering. 36 (1991)}, number = {S1}, isbn = {0013-5585}, pages = {450 -- 451}, year = {1991}, language = {de} } @article{ArtmannMontanusTeitel1991, author = {Artmann, Gerhard and Montanus, M. and Teitel, P.}, title = {Die photometrische Kapillaraggregation- ein neues Verfahren zur Messung der Erythrozytenaggregation. Montanus, M.; Artmann, Gerhard Michael; Teitel, P.}, series = {Biomedizinische Technik = Biomedical engineering. 36 (1991)}, journal = {Biomedizinische Technik = Biomedical engineering. 36 (1991)}, isbn = {0013-5585}, pages = {213 -- 215}, year = {1991}, language = {de} } @article{ArtmannWitte1991, author = {Artmann, Gerhard and Witte, Ch.}, title = {Expertensystem f{\"u}r Personal Computer zur Strukturbestimmung des Circulus Arteriosus Willisii mittels transkranieller Dopplersonografie. Witte, Ch.; Artmann, Gerhard Michael}, series = {Biomedizinische Technik = Biomedical engineering. 36 (1991)}, journal = {Biomedizinische Technik = Biomedical engineering. 36 (1991)}, isbn = {0013-5585}, pages = {228 -- 230}, year = {1991}, language = {de} } @article{MaggakisKelemenBorkKayseretal.2003, author = {Maggakis-Kelemen, C. and Bork, M. and Kayser, Peter and Biselli, Manfred and Artmann, Gerhard}, title = {Biological and mechanical quality of red blood cells cultured from human umbilical cord blood stem cells}, series = {Medical and biological engineering and computing. 41 (2003), H. 3}, journal = {Medical and biological engineering and computing. 41 (2003), H. 3}, isbn = {0140-0118}, pages = {350 -- 356}, year = {2003}, language = {en} } @article{ArtmannHueckRossiteretal.2008, author = {Artmann, Gerhard and Hueck, Isgard S. and Rossiter, Katharine and Schmid-Sch{\"o}nbein, Geert W.}, title = {Fluid Shear Attenuates Endothelial Pseudopodia Formation into the Capillary Lumen / Hueck, Isgard S. ; Rossiter, Katharine ; Artman, Gerhard M. ; Schmid-Sch{\"o}nbein, Geert W.}, series = {Microcirculation. 15 (2008), H. 6}, journal = {Microcirculation. 15 (2008), H. 6}, isbn = {1549-8719}, pages = {531 -- 542}, year = {2008}, language = {en} } @book{Artmann2008, author = {Artmann, Gerhard}, title = {Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.)}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-540-75408-4}, year = {2008}, language = {en} } @article{ArtmannZerlinDigel2008, author = {Artmann, Gerhard and Zerlin, Kay and Digel, Ilya}, title = {Hemoglobin Senses Body Temperature}, series = {Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.)}, journal = {Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.)}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-540-75408-4}, pages = {415 -- 447}, year = {2008}, language = {en} } @article{KaulKoshkaryevArtmannetal.2008, author = {Kaul, D. K. and Koshkaryev, A. and Artmann, Gerhard and Barshtein, G. and Yedgar, S.}, title = {Additive effect of red blood cell rigidity and adherence to endothelial cells in inducing vascular resistance}, series = {American Journal of Physiology : Heart and Circulation Physiology . 295 (2008), H. 4}, volume = {295}, journal = {American Journal of Physiology : Heart and Circulation Physiology . 295 (2008), H. 4}, number = {4}, issn = {1522-1539}, pages = {H1788 -- H1793}, year = {2008}, language = {en} } @article{StadlerDigelArtmannetal.2008, author = {Stadler, A. M. and Digel, Ilya and Artmann, Gerhard and Embs, Jan P. and Zaccai, Joe and B{\"u}ldt, Georg}, title = {Hemoglobin Dynamics in Red Blood Cells: Correlation to Body Temperature}, series = {Biophysical Journal. 95 (2008), H. 11}, journal = {Biophysical Journal. 95 (2008), H. 11}, isbn = {1542-0086}, pages = {5449 -- 5461}, year = {2008}, language = {en} } @article{StadlerGarveyBocahutetal.2012, author = {Stadler, Andreas M. and Garvey, G. J. and Bocahut, A. and Sacquin-Mora, S. and Digel, Ilya and Schneider, G. J. and Natali, F. and Artmann, Gerhard and Zaccai, G.}, title = {Thermal fluctuations of haemoglobin from different species : adaptation to temperature via conformational dynamics}, series = {Journal of the Royal Society Interface}, volume = {9}, journal = {Journal of the Royal Society Interface}, number = {76}, publisher = {The Royal Society}, address = {London}, issn = {1742-5689}, doi = {10.1098/rsif.2012.0364}, pages = {2845 -- 2855}, year = {2012}, abstract = {Thermodynamic stability, configurational motions and internal forces of haemoglobin (Hb) of three endotherms (platypus, Ornithorhynchus anatinus; domestic chicken, Gallus gallus domesticus and human, Homo sapiens) and an ectotherm (salt water crocodile, Crocodylus porosus) were investigated using circular dichroism, incoherent elastic neutron scattering and coarse-grained Brownian dynamics simulations. The experimental results from Hb solutions revealed a direct correlation between protein resilience, melting temperature and average body temperature of the different species on the 0.1 ns time scale. Molecular forces appeared to be adapted to permit conformational fluctuations with a root mean square displacement close to 1.2 {\AA} at the corresponding average body temperature of the endotherms. Strong forces within crocodile Hb maintain the amplitudes of motion within a narrow limit over the entire temperature range in which the animal lives. In fully hydrated powder samples of human and chicken, Hb mean square displacements and effective force constants on the 1 ns time scale showed no differences over the whole temperature range from 10 to 300 K, in contrast to the solution case. A complementary result of the study, therefore, is that one hydration layer is not sufficient to activate all conformational fluctuations of Hb in the pico- to nanosecond time scale which might be relevant for biological function. Coarse-grained Brownian dynamics simulations permitted to explore residue-specific effects. They indicated that temperature sensing of human and chicken Hb occurs mainly at residues lining internal cavities in the β-subunits.}, language = {en} } @article{BeckerWallangArtmannetal.2008, author = {Becker, C. and Wallang, C. and Artmann, Gerhard and Jakse, G.}, title = {Mechanotransduction-bioreactor for tissue engineering of a ureter prosthesis}, series = {International Journal of Artificial Organs, The}, volume = {31}, journal = {International Journal of Artificial Organs, The}, number = {7}, issn = {0391-3988}, pages = {583 -- 583}, year = {2008}, language = {en} } @article{BorkKelemenBisellietal.2000, author = {Bork, M. and Kelemen, C. and Biselli, Manfred and Artmann, Gerhard}, title = {Biophysikalische Charakterisierung ex vivo kultivierter menschlicher Erythrozythen}, series = {Biomedizinische Technik = Biomedical Engineering. 45 (2000), H. s1}, journal = {Biomedizinische Technik = Biomedical Engineering. 45 (2000), H. s1}, isbn = {1862-278X}, pages = {471 -- 472}, year = {2000}, language = {de} }