@article{HerzogPietrzykShahetal.2010, author = {Herzog, Hans and Pietrzyk, Uwe and Shah, N. Jon and Ziemons, Karl}, title = {The current state, challenges and perspectives of MR-PET}, series = {Neuroimage}, volume = {49}, journal = {Neuroimage}, number = {3}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1053-8119}, doi = {10.1016/j.neuroimage.2009.10.036}, pages = {2072 -- 2082}, year = {2010}, abstract = {Following the success of PET/CT during the last decade and the recent increasing proliferation of SPECT/CT, another hybrid imaging instrument has been gaining more and more interest: MR-PET. First combined, simultaneous PET and MR studies carried out in small animals demonstrated the feasibility of the new approach. Concurrently, some prototypes of an MR-PET scanner for simultaneous human brain studies have been built, their performance is being tested and preliminary applications have already been shown. Through this pioneering work, it has become clear that advances in the detector design are necessary for further optimization. Recently, the different issues related to the present state and future prospects of MR-PET were presented and discussed during an international 2-day workshop at the Forschungszentrum J{\"u}lich, Germany, held after, and in conjunction with, the 2008 IEEE Nuclear Science Symposium and Medical Imaging Conference in Dresden, Germany on October 27-28, 2008. The topics ranged from small animal MR-PET imaging to human MR-BrainPET imaging, new detector developments, challenges/opportunities for ultra-high field MR-PET imaging and considerations of possible future research and clinical applications. This report presents a critical summary of the contributions made to the workshop.}, language = {en} } @article{ParlLarueStreunetal.2011, author = {Parl, C. and Larue, H. and Streun, M. and Ziemons, Karl}, title = {Double-side-readout technique for SiPM-matrices}, series = {2010 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)}, journal = {2010 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)}, publisher = {IEEE}, address = {New York}, issn = {1095-7863}, pages = {1486 -- 1487}, year = {2011}, abstract = {In our case the double-side-method is used to minimize the complexity of a matrix-readout. Here the number of channels is reduced to 2√N̅. It is also possible to benefit from the method in a single pixel readout system. One signal can be used to measure position and energy of the event, the other one can be applied to a fast trigger-circuit at the same time. In a next step we will investigate timing behavior and electrical crosstalk of the circuit.}, language = {en} } @inproceedings{StreunAlKaddoumParletal.2012, author = {Streun, M. and Al-Kaddoum, R. and Parl, C. and Pietrzyk, U. and Ziemons, Karl and Waasen, S. van}, title = {Simulation studies of optical photons in monolithic block scintillators}, series = {2011 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)}, booktitle = {2011 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)}, publisher = {IEEE}, address = {New York}, isbn = {978-1-4673-0120-6 (electronic ISBN)}, doi = {10.1109/NSSMIC.2011.6154621}, pages = {1380 -- 1382}, year = {2012}, abstract = {The interest in PET detectors with monolithic block scintillators is growing. In order to obtain high spatial resolutions dedicated positioning algorithms are required. But even an ideal algorithm can only deliver information which is provided by the detector. In this simulation study we investigated the light distribution on one surface of cuboid LSO scintillators of different size. Scintillators with a large aspect ratio (small footprint and large height) showed significant position information only for a minimum interaction depth of the gamma particle. The results allow a quantitative estimate for a useful aspect ratio.}, language = {en} } @misc{RongenZiemonsSchieketal.2006, author = {Rongen, Heinz and Ziemons, Karl and Schiek, Michael and Tass, Alexander}, title = {Vorrichtung zur Messung biomedizinischer Daten eines Probanden und Verfahren zur Simulation des Probanden mit in Echtzeit verarbeiteten Daten}, pages = {1 -- 12}, year = {2006}, abstract = {Die Erfindung betrifft eine Vorrichtung zur Messung biomedizinischer Daten eines Probanden, mit einem Messsystem zur Erhebung der Daten sowie einer ersten Hardware-Komponente zur Aufzeichnung der Daten. In einer Verbindungsleitung zur {\"U}bertragung der Daten vom Messsystem zur ersten Hardware-Komponente zur Aufzeichnung der Daten ist erfindungsgem{\"a}ss ein Mittel zur galvanischen Auftrennung der Daten angeordnet. Auf diese Weise ist wenigstens die Duplizierung der Daten f{\"u}r Datenverarbeitungszwecke gew{\"a}hrleistet. Die auf diese Weise verarbeiteten Daten werden f{\"u}r ein Verfahren zur Echtzeit-Stimulation eines Probanden genutzt.}, language = {de} } @article{KhodaverdiChatziioannouWeberetal.2005, author = {Khodaverdi, M. and Chatziioannou, A. F. and Weber, S. and Ziemons, Karl and Halling, H. and Pietrzyk, U.}, title = {Investigation of different MicroCT scanner configurations by GEANT4 simulations}, series = {IEEE Transactions on Nuclear Science}, volume = {52}, journal = {IEEE Transactions on Nuclear Science}, number = {1}, isbn = {0018-9499}, pages = {188 -- 192}, year = {2005}, abstract = {This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material.}, language = {en} } @article{StreunBrandenburgLarueetal.2006, author = {Streun, M. and Brandenburg, G. and Larue, H. and Parl, C. and Ziemons, Karl}, title = {The data acquisition system of ClearPET neuro - a small animal PET scanner}, series = {IEEE Transactions on Nuclear Science}, volume = {53}, journal = {IEEE Transactions on Nuclear Science}, number = {3}, isbn = {0018-9499}, pages = {700 -- 703}, year = {2006}, abstract = {The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in J{\"u}lich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system.}, language = {en} } @article{KhodaverdiWeberStreunetal.2006, author = {Khodaverdi, M. and Weber, S. and Streun, M. and Parl, C. and Ziemons, Karl}, title = {High resolution imaging with ClearPET™ Neuro - first animal images}, series = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, journal = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, isbn = {1082-3654}, pages = {1641 -- 1644}, year = {2006}, abstract = {The ClearPET™ Neuro is the first full ring scanner within the Crystal Clear Collaboration (CCC). It consists of 80 detector modules allocated to 20 cassettes. LSO and LuYAP:Ce crystals in phoswich configuration in combination with position sensitive photomultiplier tubes are used to achieve high sensitivity and realize the acquisition of the depth of interaction (DOI) information. The complete system has been tested concerning the mechanical and electronical stability and interplay. Moreover, suitable corrections have been implemented into the reconstruction procedure to ensure high image quality. We present first results which show the successful operation of the ClearPET™ Neuro for artefact free and high resolution small animal imaging. Based on these results during the past few months the ClearPET™ Neuro System has been modified in order to optimize the performance.}, language = {en} } @article{StreunBrandenburgKhodaverdietal.2006, author = {Streun, M. and Brandenburg, G. and Khodaverdi, M. and Larue, H. and Parl, C. and Ziemons, Karl}, title = {Timemark correction for the ClearPET™ scanners}, series = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4}, journal = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4}, isbn = {1082-3654}, pages = {2057 -- 2060}, year = {2006}, abstract = {The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented}, language = {en} } @article{ZiemonsHerzogFeinendegen1990, author = {Ziemons, Karl and Herzog, H. and Feinendegen, L. E.}, title = {Iterative image reconstruction with weighted pixel contribution to projection element}, series = {European Journal of Nuclear Medicine}, volume = {16}, journal = {European Journal of Nuclear Medicine}, number = {7}, isbn = {1619-7089}, pages = {403 -- 403}, year = {1990}, language = {en} } @article{Ziemons1991, author = {Ziemons, Karl}, title = {Comparison of forward hadrons produced in muon interactions on nuclear targets and deuterium}, series = {Zeitschrift f{\"u}r Physik C Particles and Fields}, volume = {52}, journal = {Zeitschrift f{\"u}r Physik C Particles and Fields}, number = {1}, isbn = {1431-5858}, pages = {1 -- 11}, year = {1991}, abstract = {Differential multiplicities of forward produced hadrons in deep inelastic muon scattering on nuclear targets have been compared with those from deuterium. The ratios are observed to increase towards unity as the virtual photon energy increases with no significant dependence on the other muon kinematic variables. The hadron transverse momentum distribution is observed to be broadened in nuclear targets. The dependence on the remaining hadron variables is investigated and the results are discussed in the framework of intranuclear interaction models and in the context of the EMC effect.}, language = {en} } @article{Ziemons1992, author = {Ziemons, Karl}, title = {Muoproduction of J/ψ and the gluon distribution of the nucleon}, series = {Zeitschrift f{\"u}r Physik C Particles and Fields}, volume = {56}, journal = {Zeitschrift f{\"u}r Physik C Particles and Fields}, number = {1}, isbn = {1431-5858}, pages = {21 -- 28}, year = {1992}, abstract = {Measurements are presented of the inclusive distributions of the J/Ψ meson produced by muons of energy 200 GeV from an ammonia target. The gluon distribution of the nucleon has been derived from the data in the range 0.04