@article{BeckerFrauenrathHezeletal.2010, author = {Becker, Meike and Frauenrath, Tobias and Hezel, Fabian and Krombach, Gabriele A. and Kremer, Ute and Koppers, Benedikt and Butenweg, Christoph and Goemmel, Andreas and Utting, Jane F. and Schulz-Menger, Jeanette and Niendorf, Thoralf}, title = {Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T}, series = {European Radiology}, volume = {20}, journal = {European Radiology}, publisher = {Springer}, address = {Berlin}, issn = {1432-1084 (Onlineausgabe)}, doi = {10.1007/s00330-009-1676-z}, pages = {1344 -- 1355}, year = {2010}, abstract = {Objective: As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n=14). Methods: Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT's performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Results: Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct Rwave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects—even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), endsystolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived fromVCG-triggered acquisitions (1.5 T: ESVVCG=(56± 17) ml, EDVVCG=(151±32)ml, LVMVCG=(97±27) g, SVVCG=(94± 19)ml, EFVCG=(63±5)\% cf. ESVACT= (56±18) ml, EDVACT=(147±36) ml, LVMACT=(102±29) g, SVACT=(91± 22) ml, EFACT=(62±6)\%; 3.0 T: ESVVCG=(55±21) ml, EDVVCG=(151±32) ml, LVMVCG=(101±27) g, SVVCG=(96±15) ml, EFVCG=(65±7)\% cf. ESVACT=(54±20) ml, EDVACT=(146±35) ml, LVMACT= (101±30) g, SVACT=(92±17) ml, EFACT=(64±6)\%). Conclusions: ACT's intrinsic insensitivity to interference from electromagnetic fields renders}, language = {en} } @inproceedings{FrauenrathGoemmelButenwegetal.2010, author = {Frauenrath, Tobias and G{\"o}mmel, Andreas and Butenweg, Christoph and Otten, Mario and Niendorf, Thoralf}, title = {3D mapping of vocal fold geometry during articulatory maneuvers using ultrashort echo time imaging at 3.0 T}, series = {ISMRM-ESMRMB joint annual meeting 2010, Band 4}, booktitle = {ISMRM-ESMRMB joint annual meeting 2010, Band 4}, publisher = {Curran}, address = {Red Hook, NY}, organization = {International Society of Magnetic Resonance in Medicine}, isbn = {978-1-617-82008-3}, pages = {3087}, year = {2010}, language = {en} } @inproceedings{DeyElsenFerreinetal.2021, author = {Dey, Thomas and Elsen, Ingo and Ferrein, Alexander and Frauenrath, Tobias and Reke, Michael and Schiffer, Stefan}, title = {CO2 Meter: a do-it-yourself carbon dioxide measuring device for the classroom}, series = {PETRA '21: Proceedings of the 14th Pervasive Technologies Related to Assistive Environments Conference}, booktitle = {PETRA '21: Proceedings of the 14th Pervasive Technologies Related to Assistive Environments Conference}, editor = {Makedon, Fillia}, publisher = {Association for Computing Machinery}, address = {New York}, isbn = {9781450387927}, doi = {10.1145/3453892.3462697}, pages = {292 -- 299}, year = {2021}, abstract = {In this paper we report on CO2 Meter, a do-it-yourself carbon dioxide measuring device for the classroom. Part of the current measures for dealing with the SARS-CoV-2 pandemic is proper ventilation in indoor settings. This is especially important in schools with students coming back to the classroom even with high incidents rates. Static ventilation patterns do not consider the individual situation for a particular class. Influencing factors like the type of activity, the physical structure or the room occupancy are not incorporated. Also, existing devices are rather expensive and often provide only limited information and only locally without any networking. This leaves the potential of analysing the situation across different settings untapped. Carbon dioxide level can be used as an indicator of air quality, in general, and of aerosol load in particular. Since, according to the latest findings, SARS-CoV-2 can be transmitted primarily in the form of aerosols, carbon dioxide may be used as a proxy for the risk of a virus infection. Hence, schools could improve the indoor air quality and potentially reduce the infection risk if they actually had measuring devices available in the classroom. Our device supports schools in ventilation and it allows for collecting data over the Internet to enable a detailed data analysis and model generation. First deployments in schools at different levels were received very positively. A pilot installation with a larger data collection and analysis is underway.}, language = {en} } @article{FrauenrathHezelHeinrichsetal.2009, author = {Frauenrath, Tobias and Hezel, Fabian and Heinrichs, Uwe and Kozerke, Sebastian and Utting, Jane and Kob, Malte and Butenweg, Christoph and Boesiger, Peter and Niendorf, Thoralf}, title = {Feasibility of Cardiac Gating Free of Interference With Electro-Magnetic Fields at 1.5 Tesla, 3.0 Tesla and 7.0 Tesla Using an MR-Stethoscope}, series = {Investigative Radiology}, volume = {44}, journal = {Investigative Radiology}, number = {9}, publisher = {Lippincott Williams \& Wilkins ; (via Ovid)}, address = {Philadelphia, Pa}, issn = {1536-0210 (online)}, doi = {10.1097/RLI.0b013e3181b4c15e}, pages = {539 -- 547}, year = {2009}, language = {en} } @inproceedings{AltherrConzenElsenetal.2023, author = {Altherr, Lena and Conzen, Max and Elsen, Ingo and Frauenrath, Tobias and Lyrmann, Andreas}, title = {Sensor retrofitting of existing buildings in an interdisciplinary teaching project at university level}, series = {Tagungsband AALE 2023 : mit Automatisierung gegen den Klimawandel}, booktitle = {Tagungsband AALE 2023 : mit Automatisierung gegen den Klimawandel}, editor = {Reiff-Stephan, J{\"o}rg and J{\"a}kel, Jens and Schwarz, Andr{\´e}}, publisher = {le-tex publishing services GmbH}, address = {Leipzig}, isbn = {978-3-910103-01-6}, doi = {10.33968/2023.04}, pages = {31 -- 40}, year = {2023}, abstract = {Existing residential buildings have an average lifetime of 100 years. Many of these buildings will exist for at least another 50 years. To increase the efficiency of these buildings while keeping costs at reasonable rates, they can be retrofitted with sensors that deliver information to central control units for heating, ventilation and electricity. This retrofitting process should happen with minimal intervention into existing infrastructure and requires new approaches for sensor design and data transmission. At FH Aachen University of Applied Sciences, students of different disciplines work together to learn how to design, build, deploy and operate such sensors. The presented teaching project already created a low power design for a combined CO2, temperature and humidity measurement device that can be easily integrated into most home automation systems}, language = {en} } @inproceedings{GoemmelNiendorfFrauenrathetal.2010, author = {G{\"o}mmel, Andreas and Niendorf, Thoralf and Frauenrath, Tobias and Otten, Mario and Butenweg, Christoph and Kob, Malte}, title = {3D vocal fold geometry mapping using Magnetic Resonance Imaging}, series = {Fortschritte der Akustik : 36. Deutsche Jahrestagung f{\"u}r Akustik, Band 1}, booktitle = {Fortschritte der Akustik : 36. Deutsche Jahrestagung f{\"u}r Akustik, Band 1}, publisher = {Deutsche Gesellschaft f{\"u}r Akustik}, address = {Berlin}, organization = {Deutsche Jahrestagung f{\"u}r Akustik <36, 2010, Berlin>}, isbn = {978-3-9808659-8-2}, pages = {271 -- 272}, year = {2010}, language = {en} } @misc{MartinFrauenrathZerdemetal.2011, author = {Martin, Conrad Steven and Frauenrath, Tobias and Zerdem, Celal and Renz, Wolfgang and Niendorf, Thoralf}, title = {Evaluation of Magneto Alert Sensor (MALSE) to Improve MR Safety by Decreasing the Incidence of Ferromagnetic Projectile Accidents}, series = {2011 ISMRM Annual Meeting Proceedings}, journal = {2011 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2011}, abstract = {The magnetic forces of fringe magnetic fields of MR systems on ferromagnetic components can impose a severe patient, occupational health and safety hazard. MRI accidents are listed as number 9 of the top 10 risks in modern medicine. With the advent of ultrahigh field MR systems including passively shielded magnet versions, this risk, commonly known as the missile or projectile effect is even more pronounced. A strategy employing magnetic field sensors which can be attached to ferromagnetic objects that are commonly used in a clinical environment is conceptually appealing for the pursuit of reducing the risk of ferromagnetic projectile accidents.}, language = {en} } @article{vonKnobelsdorfBrenkenhoffFrauenrathProthmannetal.2010, author = {von Knobelsdorf-Brenkenhoff, Florian and Frauenrath, Tobias and Prothmann, Marcel and Dieringer, Matthias A. and Hezel, Fabian and Renz, Wolfgang and Kretschel, Kerstin and Niendorf, Thoralf and Schulz-Menger, Jeanette}, title = {Cardiac chamber quantification using magnetic resonance imaging at 7 Tesla—a pilot study}, volume = {20}, publisher = {Springer}, address = {Berlin, Heidelberg}, issn = {0938-7994}, doi = {10.1007/s00330-010-1888-2}, pages = {2844 -- 2852}, year = {2010}, abstract = {Objectives Interest in cardiovascular magnetic resonance (CMR) at 7 T is motivated by the expected increase in spatial and temporal resolution, but the method is technically challenging. We examined the feasibility of cardiac chamber quantification at 7 T. Methods A stack of short axes covering the left ventricle was obtained in nine healthy male volunteers. At 1.5 T, steady-state free precession (SSFP) and fast gradient echo (FGRE) cine imaging with 7 mm slice thickness (STH) were used. At 7 T, FGRE with 7 mm and 4 mm STH were applied. End-diastolic volume, end-systolic volume, ejection fraction and mass were calculated. Results All 7 T examinations provided excellent blood/myocardium contrast for all slice directions. No significant difference was found regarding ejection fraction and cardiac volumes between SSFP at 1.5 T and FGRE at 7 T, while volumes obtained from FGRE at 1.5 T were underestimated. Cardiac mass derived from FGRE at 1.5 and 7 T was larger than obtained from SSFP at 1.5 T. Agreement of volumes and mass between SSFP at 1.5 T and FGRE improved for FGRE at 7 T when combined with an STH reduction to 4 mm. Conclusions This pilot study demonstrates that cardiac chamber quantification at 7 T using FGRE is feasible and agrees closely with SSFP at 1.5 T.}, language = {en} } @misc{LindelGreiserWaxmanetal.2012, author = {Lindel, Tomasz Dawid and Greiser, Andreas and Waxman, Patrick and Dietterle, Martin and Seifert, Frank and Fontius, Ulrich and Renz, Wolfgang and Dieringer, Matthias A. and Frauenrath, Tobias and Schulz-Menger, Jeanette and Niendorf, Thoralf and Ittermann, Bernd}, title = {Cardiac CINE MRI at 7 T using a transmit array}, series = {2012 ISMRM Annual Meeting Proceedings}, journal = {2012 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2012}, abstract = {With its need for high SNR and short acquisition times, Cardiac MRI (CMR) is an intriguing target application for ultrahigh field MRI. Due to the sheer size of the upper torso, however, the known RF issues of 7T MRI are also most prominent in CMR. Recent years brought substantial progress but the full potential of the ultrahigh field for CMR is yet to be exploited. Parallel transmission (pTx) is a promising approach in this context and several groups have already reported B1 shimming for 7T CMR. In such a static pTx application amplitudes and phases of all Tx channels are adjusted individually but otherwise imaging techniques established in current clinical practice 1.5 T and 3 T are applied. More advanced forms of pTx as spatially selective excitation (SSE) using Transmit SENSE promise additional benefits like faster imaging with reduced fields of view or improved SAR control. SSE requires the full dynamic capabilities of pTx, however, and for the majority of today's implemented pTx hardware the internal synchronization of the Tx array does not easily permit external triggering as needed for CMR. Here we report a software solution to this problem and demonstrate the feasibility of CINE CMR at 7 T using a Tx array.}, language = {en} } @misc{WaicziesKuehneWinteretal.2013, author = {Waiczies, Helmar and K{\"u}hne, Andr{\´e} and Winter, Lukas and Frauenrath, Tobias and Hoffmann, Werner and Ittermann, Bernd and Waiczies, Sonia and Niendorf, Thoralf}, title = {Towards theranostics of rheumatoid arthritis: 1H/19F imaging of non-steroidal anti-inflammatory drugs in hand and wrist at 7 Tesla}, series = {2013 ISMRM Annual Meeting Proceedings}, journal = {2013 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2013}, abstract = {We have developed a double-tuned ¹H/¹⁹F birdcage resonator dedicated for hand and wrist imaging at 7 T to locally image non-steroidal anti-inflammatory drugs (NSAID) such as 2-{[3-(Trifluoromethyl) phenyl]amino}benzoic acid. The preliminary in vivo images acquired by the double-tuned ¹H/¹⁹F birdcage resonator demonstrate the feasibility for ¹H/¹⁹F hand- and wrist-imaging at 7 T. While the diagnostic quality of the coil needs to be assessed in patients with inflammatory rheumatoid disease, first ¹⁹F images of the NSAID are encouraging, and point towards the prospect of applying ¹⁹F-MRI to visualize and quantify the concentration of therapeutically-active compound at the sites of inflammation.}, language = {en} }