@techreport{DilgerFischerHellmannsetal.2013, author = {Dilger, Klaus and Fischer, Fabian and Hellmanns, Mark and Werner, Frank and Wittor, Bj{\"o}rn}, title = {Applikation und Einsatz von faserverst{\"a}rkten Klebstoffen im Bauwesen (FibrAdh) : Schlussbericht : gef{\"o}rdertes Vorhaben 16.956 B / DVS-Nr. 08.072}, pages = {66 S.}, year = {2013}, language = {de} } @article{DieringerRenzLindeletal.2011, author = {Dieringer, Matthias A. and Renz, Wolfgang and Lindel, Tomasz D. and Seifert, Frank and Frauenrath, Tobias and von Knobelsdorf-Brenkenhoff, Florian and Waiczies, Helmar and Hoffmann, Werner and Rieger, Jan and Pfeiffer, Harald and Ittermann, Bernd and Schulz-Menger, Jeanette and Niendorf, Thoralf}, title = {Design and application of a four-channel transmit/receive surface coil for functional cardiac imaging at 7T}, series = {Journal of Magnetic Resonance Imaging}, volume = {33}, journal = {Journal of Magnetic Resonance Imaging}, number = {3}, publisher = {Wiley-Liss}, address = {New York}, issn = {1522-2586}, doi = {10.1002/jmri.22451}, pages = {736 -- 741}, year = {2011}, abstract = {Purpose To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T. Materials and Methods A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3. Results Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach. Conclusion A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated.}, language = {en} } @misc{DieringerRenzLindeletal.2010, author = {Dieringer, Matthias A. and Renz, Wolfgang and Lindel, Tomasz and Seifert, Frank and Frauenrath, Tobias and Waiczies, Helmar and von Knobelsdorff-Brenkhoff, Florian and Santoro, Davide and Hoffmann, Werner and Ittermann, Bernd and Schulz-Menger, Jeanette and Niendorf, Thoralf}, title = {4CH TX/RX Surface Coil for 7T: Design, Optimization and Application for Cardiac Function Imaging}, series = {2010 ISMRM-ESMRMB joint annual meeting}, journal = {2010 ISMRM-ESMRMB joint annual meeting}, issn = {1545-4428}, year = {2010}, abstract = {Practical impediments of ultra high field cardiovascular MR (CVMR) can be catalogued in exacerbated magnetic field and radio frequency (RF) inhomogeneities, susceptibility and off-resonance effects, conductive and dielectric effects in tissue, and RF power deposition constraints, which all bear the potential to spoil the benefit of CVMR at 7T. Therefore, a four element cardiac transceive surface coil array was developed. Cardiac imaging provided clinically acceptable signal homogeneity with an excellent blood myocardium contrast. Subtle anatomic structures, such as pericardium, mitral and tricuspid valves and their apparatus, papillary muscles, and trabecles were accurately delineated.}, language = {en} }