@article{KuperjansStarkeEsseretal.2000, author = {Kuperjans, Isabel and Starke, M. and Esser, J. and Meyer, J. and Donner, O.}, title = {Analyse und Konzeption von Energieanlagen unter {\"o}kologischen, wirtschaftlichen und technischen Gesichtspunkten}, series = {WLB : Umwelttechnik f{\"u}r Industrie und Kommune}, volume = {44}, journal = {WLB : Umwelttechnik f{\"u}r Industrie und Kommune}, number = {11/12}, issn = {0341-2679}, pages = {26 -- 29}, year = {2000}, language = {de} } @book{SchwarzerAltes1983, author = {Schwarzer, Klemens and Altes, J{\"u}rgen}, title = {Zum St{\"o}rungsverhalten des HTR 500 : eine Trendanalyse ; [Report] / von J. Altes ... K. Schwarzer ... - (Spezielle Berichte der Kernforschungsanlage J{\"u}lich ; 220)}, publisher = {Zentralbibliothek der Kernforschungsanlage}, address = {J{\"u}lich}, pages = {41 S. : graph. Darst.}, year = {1983}, language = {de} } @article{BreitbachAltesSzimmat1989, author = {Breitbach, Gerd and Altes, J{\"u}rgen and Szimmat, J.}, title = {Anwendung der Finite-Element-Methode bei der Berechnung des W{\"a}rmetransports durch Strahlung / J. Altes ; G. Breitbach ; J. Szimmat}, series = {International FEM-Congress : Baden-Baden, Federal Republic of Germany, 17./18. November 1986}, journal = {International FEM-Congress : Baden-Baden, Federal Republic of Germany, 17./18. November 1986}, publisher = {IKO Software Service GmbH}, address = {Stuttgart}, pages = {127 -- 148}, year = {1989}, language = {de} } @book{Heuermann2024, author = {Heuermann, Holger}, title = {Microwave technology: field simulation, non-linear circuit technology, components and subsystems, plasma technology, antennas and propagation}, publisher = {Springer}, address = {Wiesbaden}, isbn = {978-3-658-45685-6}, doi = {10.1007/978-3-658-45686-3}, pages = {XII, 391 Seiten}, year = {2024}, abstract = {The book covers various numerical field simulation methods, nonlinear circuit technology and its MF-S- and X-parameters, as well as state-of-the-art power amplifier techniques. It also describes newly presented oscillators and the emerging field of GHz plasma technology. Furthermore, it addresses aspects such as waveguides, mixers, phase-locked loops, antennas, and propagation effects, in combination with the bachelor's book 'High-Frequency Engineering,' encompassing all aspects related to the current state of GHz technology.}, language = {en} } @inproceedings{SattlerAttiAlexopoulosetal.2022, author = {Sattler, Johannes Christoph and Atti, Vikrama Naga Babu and Alexopoulos, Spiros and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf and Dutta, Siddharth and Kioutsioukis, Ioannis}, title = {DNI forecast tool for the smart operation of a parabolic trough collector system with concrete thermal energy storage: Theory, results and outlook}, series = {SolarPACES 2022 conference proceedings}, booktitle = {SolarPACES 2022 conference proceedings}, number = {1}, publisher = {TIB Open Publishing}, address = {Hannover}, issn = {2751-9899 (online)}, doi = {10.52825/solarpaces.v1i.731}, pages = {9 Seiten}, year = {2022}, abstract = {This work presents a basic forecast tool for predicting direct normal irradiance (DNI) in hourly resolution, which the Solar-Institut J{\"u}lich (SIJ) is developing within a research project. The DNI forecast data shall be used for a parabolic trough collector (PTC) system with a concrete thermal energy storage (C-TES) located at the company KEAN Soft Drinks Ltd in Limassol, Cyprus. On a daily basis, 24-hour DNI prediction data in hourly resolution shall be automatically produced using free or very low-cost weather forecast data as input. The purpose of the DNI forecast tool is to automatically transfer the DNI forecast data on a daily basis to a main control unit (MCU). The MCU automatically makes a smart decision on the operation mode of the PTC system such as steam production mode and/or C-TES charging mode. The DNI forecast tool was evaluated using historical data of measured DNI from an on-site weather station, which was compared to the DNI forecast data. The DNI forecast tool was tested using data from 56 days between January and March 2022, which included days with a strong variation in DNI due to cloud passages. For the evaluation of the DNI forecast reliability, three categories were created and the forecast data was sorted accordingly. The result was that the DNI forecast tool has a reliability of 71.4 \% based on the tested days. The result fulfils SIJ's aim to achieve a reliability of around 70 \%, but SIJ aims to still improve the DNI forecast quality.}, language = {en} } @inproceedings{DuranParedesMottaghyHerrmannetal.2020, author = {Duran Paredes, Ludwin and Mottaghy, Darius and Herrmann, Ulf and Groß, Rolf Fritz}, title = {Online ground temperature and soil moisture monitoring of a shallow geothermal system with non-conventional components}, series = {EGU General Assembly 2020}, booktitle = {EGU General Assembly 2020}, year = {2020}, abstract = {We present first results from a newly developed monitoring station for a closed loop geothermal heat pump test installation at our campus, consisting of helix coils and plate heat exchangers, as well as an ice-store system. There are more than 40 temperature sensors and several soil moisture content sensors distributed around the system, allowing a detailed monitoring under different operating conditions.In the view of the modern development of renewable energies along with the newly concepts known as Internet of Things and Industry 4.0 (high-tech strategy from the German government), we created a user-friendly web application, which will connect the things (sensors) with the open network (www). Besides other advantages, this allows a continuous remote monitoring of the data from the numerous sensors at an arbitrary sampling rate.Based on the recorded data, we will also present first results from numerical simulations, taking into account all relevant heat transport processes.The aim is to improve the understanding of these processes and their influence on the thermal behavior of shallow geothermal systems in the unsaturated zone. This will in turn facilitate the prediction of the performance of these systems and therefore yield an improvement in their dimensioning when designing a specific shallow geothermal installation.}, language = {en} } @inproceedings{SattlerChicoCaminosUerlingsetal.2020, author = {Sattler, Johannes Christoph and Chico Caminos, Ricardo Alexander and {\"U}rlings, Nicolas and Dutta, Siddharth and Ruiz, Victor and Kalogirou, Soteris and Ktistis, Panayiotis and Agathokleous, Rafaela and Jung, Christian and Alexopoulos, Spiros and Atti, Vikrama Naga Babu and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf}, title = {Operational experience and behaviour of a parabolic trough collector system with concrete thermal energy storage for process steam generation in Cyprus}, series = {AIP Conference Proceedings}, booktitle = {AIP Conference Proceedings}, number = {2303}, doi = {10.1063/5.0029278}, pages = {140004-1 -- 140004-10}, year = {2020}, abstract = {As part of the transnational research project EDITOR, a parabolic trough collector system (PTC) with concrete thermal energy storage (C-TES) was installed and commissioned in Limassol, Cyprus. The system is located on the premises of the beverage manufacturer KEAN Soft Drinks Ltd. and its function is to supply process steam for the factory's pasteurisation process [1]. Depending on the factory's seasonally varying capacity for beverage production, the solar system delivers between 5 and 25 \% of the total steam demand. In combination with the C-TES, the solar plant can supply process steam on demand before sunrise or after sunset. Furthermore, the C-TES compensates the PTC during the day in fluctuating weather conditions. The parabolic trough collector as well as the control and oil handling unit is designed and manufactured by Protarget AG, Germany. The C-TES is designed and produced by CADE Soluciones de Ingenier{\´i}a, S.L., Spain. In the focus of this paper is the description of the operational experience with the PTC, C-TES and boiler during the commissioning and operation phase. Additionally, innovative optimisation measures are presented.}, language = {en} } @incollection{HoffschmidtAlexopoulosGoettscheetal.2022, author = {Hoffschmidt, Bernhard and Alexopoulos, Spiros and G{\"o}ttsche, Joachim and Sauerborn, Markus and Kaufhold, O.}, title = {High Concentration Solar Collectors}, series = {Comprehensive Renewable Energy (Second Edition) / Volume 3: Solar Thermal Systems: Components and Applications}, booktitle = {Comprehensive Renewable Energy (Second Edition) / Volume 3: Solar Thermal Systems: Components and Applications}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {978-0-12-819734-9}, doi = {10.1016/B978-0-12-819727-1.00058-3}, pages = {198 -- 245}, year = {2022}, abstract = {Solar thermal concentrated power is an emerging technology that provides clean electricity for the growing energy market. To the solar thermal concentrated power plant systems belong the parabolic trough, the Fresnel collector, the solar dish, and the central receiver system. For high-concentration solar collector systems, optical and thermal analysis is essential. There exist a number of measurement techniques and systems for the optical and thermal characterization of the efficiency of solar thermal concentrated systems. For each system, structure, components, and specific characteristics types are described. The chapter presents additionally an outline for the calculation of system performance and operation and maintenance topics. One main focus is set to the models of components and their construction details as well as different types on the market. In the later part of this article, different criteria for the choice of technology are analyzed in detail.}, language = {en} } @article{ButenwegFehling2012, author = {Butenweg, Christoph and Fehling, Ekkehard}, title = {Hintergrund f{\"u}r die vereinfachten Regeln bei Mauerwerksgeb{\"a}uden im Erdbebenfall}, series = {Mauerwerk : European journal of masonry}, volume = {16}, journal = {Mauerwerk : European journal of masonry}, number = {3}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1022 (E-Journal); 1432-3427 (Print)}, doi = {10.1002/dama.201200537}, pages = {127 -- 137}, year = {2012}, abstract = {Bei der Ausarbeitung des nationalen Anwendungsdokumentes zur DIN EN 1998-1 waren die in der ENV-Fassung enthaltenen vereinfachten Regeln im Lichte aktueller Forschungsergebnisse zu {\"u}berpr{\"u}fen und zu {\"u}berarbeiten. Die gleiche Aufgabe stellte sich auch f{\"u}r die Neufassung der DIN 4149. In beiden F{\"a}llen sind neben konstruktiven Regeln f{\"u}r die Art und Anordnung der zur Geb{\"a}udeaussteifung heranzuziehenden W{\"a}nde im Grundriss Tabellen enthalten, die unter bestimmten Bedingungen den Entfall eines rechnerischen Nachweises der Tragw{\"a}nde im Erdbebenfall erm{\"o}glichen. Dies ist f{\"u}r Schwachbebengebiete, wie sie in Deutschland und anderen L{\"a}ndern Mitteleuropas anzutreffen sind, sinnvoll, um unn{\"o}tigen Rechenaufwand sowie Probleme mit der F{\"u}hrbarkeit von Nachweisen so weit wie m{\"o}glich auszuschalten. Im vorliegenden Beitrag werden die Hintergr{\"u}nde der vereinfachten Regeln diskutiert und die Ergebnisse der Anwendung mit verschiedenen Rechenverfahren verglichen und bewertet.}, language = {de} } @article{ButenwegGellert2012, author = {Butenweg, Christoph and Gellert, Christoph}, title = {Integrale Geb{\"a}udeplanung am Beispiel eines Geschossbaus in Ziegelmauerwerk}, series = {Mauerwerk : European journal of masonry}, volume = {16}, journal = {Mauerwerk : European journal of masonry}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1022 (E-Journal); 1432-3427 (Print)}, doi = {10.1002/dama.201200550}, pages = {247 -- 254}, year = {2012}, abstract = {Moderne Mauerwerksbauten m{\"u}ssen nach heutigen Anforderungen architektonisch, statisch, energetisch sowie schall- und brandschutztechnisch optimal ausgelegt sein. Aufgrund der Komplexit{\"a}t und engen Verzahnung der einzelnen Anforderungen ist eine integrale Geb{\"a}udeplanung zur Erzielung einer qualitativ hochwertigen Bauwerksl{\"o}sung unbedingt notwendig. Diese erfordert von den Fachplanern vertieftes Spezialwissen in den verschiedenen Bereichen, um insbesondere die Schnittstellen und Bauwerksdetails korrekt zu planen und auszuf{\"u}hren. Der Beitrag stellt die integrale Geb{\"a}udeplanung am Beispiel eines Geschossbaus in Ziegelbauweise mit L{\"o}sungen f{\"u}r wesentliche Detailpunkte vor}, language = {de} }