@inproceedings{SattlerAlexopoulosChicoCaminosetal.2019, author = {Sattler, Johannes Christoph and Alexopoulos, Spiros and Chico Caminos, Ricardo Alexander and Mitchell, John C. and Ruiz, Victor C. and Kalogirou, Soteris and Ktistis, Panayiotis K. and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf}, title = {Dynamic simulation model of a parabolic trough collector system with concrete thermal energy storage for process steam generation}, series = {AIP Conference Proceedings}, volume = {2126}, booktitle = {AIP Conference Proceedings}, issn = {0094243X}, doi = {10.1063/1.5117663}, pages = {150007-1 -- 150007-8}, year = {2019}, language = {en} } @inproceedings{GoettscheKornAmato2015, author = {G{\"o}ttsche, Joachim and Korn, Michael and Amato, Alexandre}, title = {The Passivhaus concept for the Arabian Peninsula - An energetic-economical evaluation considering the thermal comfort}, series = {QScience Proceedings: Vol 2015}, booktitle = {QScience Proceedings: Vol 2015}, doi = {10.5339/qproc.2015.qgbc.38}, pages = {8 Seiten}, year = {2015}, abstract = {The Passivhaus building standard is a concept developed for the realization of energy-efficient and economical buildings with a simultaneous high utilization comfort under European climate conditions. Major elements of the Passivhaus concept are a high thermal insulation of the external walls, the use of heat and/or solar shading glazing as well as an airtight building envelope in combination with energy-efficient technical building installations and heating or cooling generators, such as an efficient energy-recovery in the building air-conditioning. The objective of this research project is the inquiry to determine the parameters or constraints under which the Passivhaus concept can be implemented under the arid climate conditions in the Arabian Peninsula to achieve an energy-efficient and economical building with high utilization comfort. In cooperation between the Qatar Green Building Council (QGBC), Barwa Real Estate (BRE) and Kahramaa the first Passivhaus was constructed in Qatar and on the Arabian Peninsula in 2013. The Solar-Institut J{\"u}lich of Aachen University of Applied Science supports the Qatar Green Building Council with a dynamic building and equipment simulation of the Passivhaus and the neighbouring reference building. This includes simulation studies with different component configurations for the building envelope and different control strategies for heating or cooling systems as well as the air conditioning of buildings to find an energetic-economical optimum. Part of these analyses is the evaluation of the energy efficiency of the used energy recovery system in the Passivhaus air-conditioning and identification of possible energy-saving effects by the use of a bypass function integrated in the heat exchanger. In this way it is expected that on an annual basis the complete electricity demand of the building can be covered by the roof-integrated PV generator.}, language = {en} } @inproceedings{AnthrakidisHerrmannSchornetal.2015, author = {Anthrakidis, Anette and Herrmann, Ulf and Schorn, Christian and Schwarzer, Klemens and Wedding, Philipp and Weis, Fabian}, title = {Development and Testing of a Novel Method for the Determination of the Efficiency of Concentrating Solar Thermal Collectors}, series = {Conference Proceedings Solar World Congress 2015, Daegu, Korea, 08 - 12 November 2015}, booktitle = {Conference Proceedings Solar World Congress 2015, Daegu, Korea, 08 - 12 November 2015}, pages = {9 Seiten}, year = {2015}, language = {en} } @inproceedings{HerrmannWorringerGraeteretal.2006, author = {Herrmann, Ulf and Worringer, S. and Graeter, F. and Nava, P.}, title = {Three Years of Operation Experience of the SKAL-ET Collector Loop at SEGS V}, series = {13th International Symposium Concentrated Solar Power and Chemical Energy Technologies, June 20 - 23, 2006, Seville, Spain}, booktitle = {13th International Symposium Concentrated Solar Power and Chemical Energy Technologies, June 20 - 23, 2006, Seville, Spain}, editor = {Romero, Manuel}, publisher = {SolarPACES [u.a.]}, address = {[s.l.]}, isbn = {84-7834-519-1}, pages = {1 CD-ROM}, year = {2006}, language = {en} } @inproceedings{HerrmannGraeterNava2004, author = {Herrmann, Ulf and Graeter, F. and Nava, P.}, title = {Performance of the SKAL-ET Collector Loop at KJC Operating Company}, series = {12th International Symposium Solar Power and Chemical Energy Systems, October 6-8, 2004, Oaxaca Mexico ; SolarPACES International Symposium, 12}, booktitle = {12th International Symposium Solar Power and Chemical Energy Systems, October 6-8, 2004, Oaxaca Mexico ; SolarPACES International Symposium, 12}, editor = {Ramos, C.}, publisher = {Instituto de Investigaciones Electricas}, address = {[s.l.]}, isbn = {968-6114-18-1}, year = {2004}, language = {en} } @article{HerrmannKellyPrice2002, author = {Herrmann, Ulf and Kelly, Bruce and Price, Henry}, title = {Two Tank Molten Salt Storage for Parabolic Trough Solar Power Plants}, series = {Energy : the international journal}, volume = {29}, journal = {Energy : the international journal}, number = {5-6 (Special Issue SolarPaces)}, issn = {0360-5442}, doi = {10.1016/S0360-5442(03)00193-2}, pages = {883 -- 893}, year = {2002}, language = {en} } @article{DerschGeyerHerrmannetal.2004, author = {Dersch, J{\"u}rgen and Geyer, Michael and Herrmann, Ulf and Jones, Scott A. and Kelly, Bruce and Kistner, Rainer and Ortmanns, Winfried and Pitz-Paal, Robert and Price, Henry}, title = {Trough integration into power plants—a study on the performance and economy of integrated solar combined cycle systems}, series = {Energy : the international journal}, volume = {29}, journal = {Energy : the international journal}, number = {5-6 (Special Issue SolarPaces)}, issn = {0360-5442}, doi = {10.1016/S0360-5442(03)00199-3}, pages = {947 -- 959}, year = {2004}, language = {en} } @article{PuppeGiulianoFrantzetal.2018, author = {Puppe, Michael and Giuliano, Stefano and Frantz, Cathy and Uhlig, Ralf and Schumacher, Ralph and Ibraheem, Wagdi and Schmalz, Stefan and Waldmann, Barbara and Guder, Christoph and Peter, Dennis and Schwager, Christian and Teixeira Boura, Cristiano Jos{\´e} and Alexopoulos, Spiros and Spiegel, Michael and Wortmann, J{\"u}rgen and Hinrichs, Matthias and Engelhard, Manfred and Aust, Michael}, title = {Techno-economic optimization of molten salt solar tower plants}, series = {AIP Conference Proceedings art.no. 040033}, volume = {2033}, journal = {AIP Conference Proceedings art.no. 040033}, number = {Issue 1}, publisher = {AIP Publishing}, address = {Melville, NY}, doi = {10.1063/1.5067069}, year = {2018}, abstract = {In this paper the results of a techno-economic analysis of improved and optimized molten salt solar tower plants (MSSTP plants) are presented. The potential improvements that were analyzed include different receiver designs, different designs of the HTF-system and plant control, increased molten salt temperatures (up to 640°C) and multi-tower systems. Detailed technological and economic models of the solar field, solar receiver and high temperature fluid system (HTF-system) were developed and used to find potential improvements compared to a reference plant based on Solar Two technology and up-to-date cost estimations. The annual yield model calculates the annual outputs and the LCOE of all variants. An improved external tubular receiver and improved HTF-system achieves a significant decrease of LCOE compared to the reference. This is caused by lower receiver cost as well as improvements of the HTF-system and plant operation strategy, significantly reducing the plant own consumption. A novel star receiver shows potential for further cost decrease. The cavity receiver concepts result in higher LCOE due to their high investment cost, despite achieving higher efficiencies. Increased molten salt temperatures seem possible with an adapted, closed loop HTF-system and achieve comparable results to the original improved system (with 565°C) under the given boundary conditions. In this analysis all multi tower systems show lower economic viability compared to single tower systems, caused by high additional cost for piping connections and higher cost of the receivers. REFERENCES}, language = {en} } @inproceedings{AringhoffGeyerHerrmannetal.2002, author = {Aringhoff, R. and Geyer, Michael and Herrmann, Ulf and Kistner, Rainer and Nava, P. and Osuna, R.}, title = {AndaSol : 50MW Solar Plants with 9 Hour Storage for Southern Spain}, series = {Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgen{\"o}ssische Technische Hochschule Z{\"u}rich}, booktitle = {Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgen{\"o}ssische Technische Hochschule Z{\"u}rich}, editor = {Steinfeld, Aldo}, publisher = {Paul Scherrer Inst.}, address = {Villingen}, isbn = {3-9521409-3-7}, pages = {37 -- 42}, year = {2002}, language = {en} } @inproceedings{HerrmannKellyPrice2002, author = {Herrmann, Ulf and Kelly, Bruce and Price, Henry}, title = {Two Tank Molten Salt Storage for Parabolic Trough Solar Power Plants}, series = {Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgen{\"o}ssische Technische Hochschule Z{\"u}rich}, booktitle = {Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgen{\"o}ssische Technische Hochschule Z{\"u}rich}, editor = {Steinfeld, Aldo}, publisher = {Paul Scherrer Inst.}, address = {Villingen}, isbn = {3-9521409-3-7}, pages = {517 -- 524}, year = {2002}, language = {en} } @inproceedings{JanotteFecklerKoetteretal.2014, author = {Janotte, N. and Feckler, G. and K{\"o}tter, Jens and Decker, Stefan and Herrmann, Ulf and Schmitz, Mark and L{\"u}pfert, E.}, title = {Dynamic performance evaluation of the HelioTrough® collector demonstration loop : towards a new benchmark in parabolic trough qualification}, series = {SolarPACES International Conference 2013, Las Vegas, Nevada, USA, 17 - 20 September 2013 : [proceedings]. - Pt. 1. - (Energy procedia ; 49)}, booktitle = {SolarPACES International Conference 2013, Las Vegas, Nevada, USA, 17 - 20 September 2013 : [proceedings]. - Pt. 1. - (Energy procedia ; 49)}, publisher = {Curran}, address = {Red Hook, NY}, isbn = {978-1-63266-904-9}, issn = {1876-6102}, doi = {10.1016/j.egypro.2014.03.012}, pages = {109 -- 117}, year = {2014}, language = {en} } @article{GorzalkaSchmiedtSchorn2021, author = {Gorzalka, Philip and Schmiedt, Jacob Estevam and Schorn, Christian}, title = {Automated Generation of an Energy Simulation Model for an Existing Building from UAV Imagery}, series = {Buildings}, volume = {11}, journal = {Buildings}, number = {9}, publisher = {MDPI}, address = {Basel}, issn = {2075-5309}, doi = {10.3390/buildings11090380}, pages = {15 Seiten}, year = {2021}, abstract = {An approach to automatically generate a dynamic energy simulation model in Modelica for a single existing building is presented. It aims at collecting data about the status quo in the preparation of energy retrofits with low effort and costs. The proposed method starts from a polygon model of the outer building envelope obtained from photogrammetrically generated point clouds. The open-source tools TEASER and AixLib are used for data enrichment and model generation. A case study was conducted on a single-family house. The resulting model can accurately reproduce the internal air temperatures during synthetical heating up and cooling down. Modelled and measured whole building heat transfer coefficients (HTC) agree within a 12\% range. A sensitivity analysis emphasises the importance of accurate window characterisations and justifies the use of a very simplified interior geometry. Uncertainties arising from the use of archetype U-values are estimated by comparing different typologies, with best- and worst-case estimates showing differences in pre-retrofit heat demand of about ±20\% to the average; however, as the assumptions made are permitted by some national standards, the method is already close to practical applicability and opens up a path to quickly estimate possible financial and energy savings after refurbishment.}, language = {en} } @inproceedings{KellyHerrmannHale2001, author = {Kelly, Bruce and Herrmann, Ulf and Hale, M.-J.}, title = {Optimization Studies for Integrated Solar Combined Cycle Systems}, series = {Solar engineering 2001 : proceedings of the International Solar Energy Conference ; presented at the 2001 International Solar Energy Conference, a part of Forum 2001 - Solar energy: the power to choose, April 21 - 25, 2001, Washington, D.C.}, booktitle = {Solar engineering 2001 : proceedings of the International Solar Energy Conference ; presented at the 2001 International Solar Energy Conference, a part of Forum 2001 - Solar energy: the power to choose, April 21 - 25, 2001, Washington, D.C.}, publisher = {ASME}, address = {New York, NY}, isbn = {0-7918-1670-2}, pages = {393 -- 398}, year = {2001}, language = {en} } @inproceedings{AlexopoulosHoffschmidtRauetal.2012, author = {Alexopoulos, Spiros and Hoffschmidt, Bernhard and Rau, Christoph and Sattler, Johannes Christoph}, title = {Simulation of hybrid solar tower power plants}, series = {30th ISES Biennial Solar World Congress 2011 : Kassel, Germany, 28 August - 2 September 2011. Vol. 5}, booktitle = {30th ISES Biennial Solar World Congress 2011 : Kassel, Germany, 28 August - 2 September 2011. Vol. 5}, publisher = {Curran}, address = {Red Hook, NY}, organization = {International Solar Energy Society}, pages = {4044 -- 4050}, year = {2012}, language = {en} } @article{GoettscheHove1999, author = {G{\"o}ttsche, Joachim and Hove, T.}, title = {Mapping global, diffuse and beam solar radiation over Zimbabwe / T. Hove ; J. G{\"o}ttsche}, series = {Renewable energy. 18 (1999), H. 4}, journal = {Renewable energy. 18 (1999), H. 4}, isbn = {1879-0682}, pages = {535 -- 556}, year = {1999}, language = {en} } @article{Goettsche1994, author = {G{\"o}ttsche, Joachim}, title = {Eldorado summer schools}, series = {Progress in solar energy education. 3 (1994)}, journal = {Progress in solar energy education. 3 (1994)}, isbn = {1018-5607}, pages = {31 -- 33}, year = {1994}, language = {en} } @inproceedings{MohanGrossMenzeletal.2021, author = {Mohan, Nijanthan and Groß, Rolf Fritz and Menzel, Karsten and Theis, Fabian}, title = {Opportunities and Challenges in the Implementation of Building Information Modeling for Prefabrication of Heating, Ventilation and Air Conditioning Systems in Small and Medium-Sized Contracting Companies in Germany - A Case Study}, series = {WIT Transactions on The Built Environment, Vol. 205}, booktitle = {WIT Transactions on The Built Environment, Vol. 205}, publisher = {WIT Press}, address = {Southampton}, issn = {1743-3509}, doi = {10.2495/BIM210101}, pages = {117 -- 126}, year = {2021}, abstract = {Even though BIM (Building Information Modelling) is successfully implemented in most of the world, it is still in the early stages in Germany, since the stakeholders are sceptical of its reliability and efficiency. The purpose of this paper is to analyse the opportunities and obstacles to implementing BIM for prefabrication. Among all other advantages of BIM, prefabrication is chosen for this paper because it plays a vital role in creating an impact on the time and cost factors of a construction project. The project stakeholders and participants can explicitly observe the positive impact of prefabrication, which enables the breakthrough of the scepticism factor among the small-scale construction companies. The analysis consists of the development of a process workflow for implementing prefabrication in building construction followed by a practical approach, which was executed with two case studies. It was planned in such a way that, the first case study gives a first-hand experience for the workers at the site on the BIM model so that they can make much use of the created BIM model, which is a better representation compared to the traditional 2D plan. The main aim of the first case study is to create a belief in the implementation of BIM Models, which was succeeded by the execution of offshore prefabrication in the second case study. Based on the case studies, the time analysis was made and it is inferred that the implementation of BIM for prefabrication can reduce construction time, ensures minimal wastes, better accuracy, less problem-solving at the construction site. It was observed that this process requires more planning time, better communication between different disciplines, which was the major obstacle for successful implementation. This paper was carried out from the perspective of small and medium-sized mechanical contracting companies for the private building sector in Germany.}, language = {en} } @inproceedings{GorzalkaDahlkeGoettscheetal.2018, author = {Gorzalka, Philip and Dahlke, Dennis and G{\"o}ttsche, Joachim and Israel, Martin and Patel, Dhruvkumar and Prahl, Christoph and Schmiedt, Jacob Estevam and Frommholz, Dirk and Hoffschmidt, Bernhard and Linkiewicz, Magdalena}, title = {Building Tomograph-From Remote Sensing Data of Existing Buildings to Building Energy Simulation Input}, series = {EBC, Annex 71, Fifth expert meeting, October 17-19, 2018, Innsbruck, Austria}, booktitle = {EBC, Annex 71, Fifth expert meeting, October 17-19, 2018, Innsbruck, Austria}, pages = {17 Seiten}, year = {2018}, language = {en} } @inproceedings{DerschGeyerHerrmannetal.2002, author = {Dersch, J{\"u}rgen and Geyer, Michael and Herrmann, Ulf and Jones, Scott A. and Kelly, Bruce and Kistner, Rainer and Ortmanns, Winfried and Pitz-Paal, Robert and Price, Henry}, title = {Trough integration into power plants : a study on the performance and economy of integrated solar combined cycle systems}, series = {Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgen{\"o}ssische Technische Hochschule Z{\"u}rich}, booktitle = {Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgen{\"o}ssische Technische Hochschule Z{\"u}rich}, editor = {Steinfeld, Aldo}, publisher = {Paul Scherrer Inst.}, address = {Villingen}, isbn = {3-9521409-3-7}, pages = {661 -- 671}, year = {2002}, language = {en} } @inproceedings{HahneHerrmannRheinlaender1997, author = {Hahne, E. and Herrmann, Ulf and Rheinl{\"a}nder, J.}, title = {The Effect of Tilt on Flow Pattern of Water/Steam Flow Through Heated Tubes}, series = {Experimental heat transfer, fluid mechanics and thermodynamics 1997 : proceedings of the 4th World Conference on Experimental Heat Transfer, Fluid Mechanics and Thermodynamics, Brussels, June 2 - 6, 1997. - Vol. 2}, booktitle = {Experimental heat transfer, fluid mechanics and thermodynamics 1997 : proceedings of the 4th World Conference on Experimental Heat Transfer, Fluid Mechanics and Thermodynamics, Brussels, June 2 - 6, 1997. - Vol. 2}, editor = {Girot, Michel}, publisher = {Ed. ETS}, address = {Pisa}, isbn = {88-467-0014-7}, pages = {925 -- 934}, year = {1997}, language = {en} }