@techreport{WeisSchornAnthrakidisetal.2016, author = {Weis, Fabian and Schorn, Christian and Anthrakidis, Anette and Herrmann, Ulf}, title = {Entwicklung eines kleinen Parabolrinnenkollektors mit Kunststoffkorpus zur Bereitstellung solarer Prozessw{\"a}rme : Poly-P : Abschlussbericht}, publisher = {Solar-Institut J{\"u}lich}, address = {J{\"u}lich}, pages = {56 Seiten}, year = {2016}, language = {de} } @inproceedings{GedleSchmitzGielenetal.2022, author = {Gedle, Yibekal and Schmitz, Mark and Gielen, Hans and Schmitz, Pascal and Herrmann, Ulf and Teixeira Boura, Cristiano Jos{\´e} and Mahdi, Zahra and Chico Caminos, Ricardo Alexander and Dersch, J{\"u}rgen}, title = {Analysis of an integrated CSP-PV hybrid power plant}, series = {SOLARPACES 2020}, booktitle = {SOLARPACES 2020}, number = {2445 / 1}, publisher = {AIP conference proceedings / American Institute of Physics}, address = {Melville, NY}, isbn = {978-0-7354-4195-8}, issn = {1551-7616 (online)}, doi = {10.1063/5.0086236}, pages = {9 Seiten}, year = {2022}, abstract = {In the past, CSP and PV have been seen as competing technologies. Despite massive reductions in the electricity generation costs of CSP plants, PV power generation is - at least during sunshine hours - significantly cheaper. If electricity is required not only during the daytime, but around the clock, CSP with its inherent thermal energy storage gets an advantage in terms of LEC. There are a few examples of projects in which CSP plants and PV plants have been co-located, meaning that they feed into the same grid connection point and ideally optimize their operation strategy to yield an overall benefit. In the past eight years, TSK Flagsol has developed a plant concept, which merges both solar technologies into one highly Integrated CSP-PV-Hybrid (ICPH) power plant. Here, unlike in simply co-located concepts, as analyzed e.g. in [1] - [4], excess PV power that would have to be dumped is used in electric molten salt heaters to increase the storage temperature, improving storage and conversion efficiency. The authors demonstrate the electricity cost sensitivity to subsystem sizing for various market scenarios, and compare the resulting optimized ICPH plants with co-located hybrid plants. Independent of the three feed-in tariffs that have been assumed, the ICPH plant shows an electricity cost advantage of almost 20\% while maintaining a high degree of flexibility in power dispatch as it is characteristic for CSP power plants. As all components of such an innovative concept are well proven, the system is ready for commercial market implementation. A first project is already contracted and in early engineering execution.}, language = {en} } @inproceedings{NiederwestbergSchneiderTeixeiraBouraetal.2022, author = {Niederwestberg, Stefan and Schneider, Falko and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf}, title = {Introduction to a direct irradiated transparent tube particle receiver}, series = {SOLARPACES 2020}, booktitle = {SOLARPACES 2020}, number = {2445 / 1}, publisher = {AIP conference proceedings / American Institute of Physics}, address = {Melville, NY}, isbn = {978-0-7354-4195-8}, issn = {1551-7616 (online)}, doi = {10.1063/5.0086735}, pages = {9 Seiten}, year = {2022}, abstract = {New materials often lead to innovations and advantages in technical applications. This also applies to the particle receiver proposed in this work that deploys high-temperature and scratch resistant transparent ceramics. With this receiver design, particles are heated through direct-contact concentrated solar irradiance while flowing downwards through tubular transparent ceramics from top to bottom. In this paper, the developed particle receiver as well as advantages and disadvantages are described. Investigations on the particle heat-up characteristics from solar irradiance were carried out with DEM simulations which indicate that particle temperatures can reach up to 1200 K. Additionally, a simulation model was set up for investigating the dynamic behavior. A test receiver at laboratory scale has been designed and is currently being built. In upcoming tests, the receiver test rig will be used to validate the simulation results. The design and the measurement equipment is described in this work.}, language = {en} } @inproceedings{HerrmannWorringerGraeteretal.2006, author = {Herrmann, Ulf and Worringer, S. and Graeter, F. and Nava, P.}, title = {Three Years of Operation Experience of the SKAL-ET Collector Loop at SEGS V}, series = {13th International Symposium Concentrated Solar Power and Chemical Energy Technologies, June 20 - 23, 2006, Seville, Spain}, booktitle = {13th International Symposium Concentrated Solar Power and Chemical Energy Technologies, June 20 - 23, 2006, Seville, Spain}, editor = {Romero, Manuel}, publisher = {SolarPACES [u.a.]}, address = {[s.l.]}, isbn = {84-7834-519-1}, pages = {1 CD-ROM}, year = {2006}, language = {en} } @inproceedings{GoettscheRoether2014, author = {G{\"o}ttsche, Joachim and R{\"o}ther, Sascha}, title = {Science College Overbach - Innovatives Bildungszentrum in J{\"u}lich-Barmen}, series = {18. Internationale Passivhaustagung, Aachen, April 2014}, booktitle = {18. Internationale Passivhaustagung, Aachen, April 2014}, pages = {6 Seiten}, year = {2014}, abstract = {Preprint der Autoren}, language = {de} } @inproceedings{BreitbachAlexopoulosHoffschmidt2007, author = {Breitbach, Gerd and Alexopoulos, Spiros and Hoffschmidt, Bernhard}, title = {Fluid flow in porous ceramic multichannel crossflower filter modules}, publisher = {COMSOL Inc.}, address = {Burlington, Mass.}, pages = {5 S.}, year = {2007}, language = {en} } @inproceedings{JanotteFecklerKoetteretal.2014, author = {Janotte, N. and Feckler, G. and K{\"o}tter, Jens and Decker, Stefan and Herrmann, Ulf and Schmitz, Mark and L{\"u}pfert, E.}, title = {Dynamic performance evaluation of the HelioTrough® collector demonstration loop : towards a new benchmark in parabolic trough qualification}, series = {SolarPACES International Conference 2013, Las Vegas, Nevada, USA, 17 - 20 September 2013 : [proceedings]. - Pt. 1. - (Energy procedia ; 49)}, booktitle = {SolarPACES International Conference 2013, Las Vegas, Nevada, USA, 17 - 20 September 2013 : [proceedings]. - Pt. 1. - (Energy procedia ; 49)}, publisher = {Curran}, address = {Red Hook, NY}, isbn = {978-1-63266-904-9}, issn = {1876-6102}, doi = {10.1016/j.egypro.2014.03.012}, pages = {109 -- 117}, year = {2014}, language = {en} } @article{RegerKuhnhenneHachuletal.2019, author = {Reger, Vitali and Kuhnhenne, Markus and Hachul, Helmut and D{\"o}ring, Bernd and Blanke, Tobias and G{\"o}ttsche, Joachim}, title = {Plusenergiegeb{\"a}ude 2.0 in Stahlleichtbauweise}, series = {Stahlbau}, volume = {88}, journal = {Stahlbau}, number = {6}, publisher = {Ernst \& Sohn}, address = {Berlin}, issn = {1437-1049 (E-journal), 0038-9145 (print)}, doi = {10.1002/stab.201900034}, pages = {522 -- 528}, year = {2019}, language = {de} } @techreport{GhinaiyaLehmannGoettsche2022, author = {Ghinaiya, Jagdishkumar and Lehmann, Thomas and G{\"o}ttsche, Joachim}, title = {LOCAL+ - ein kreislauff{\"a}higer Holzmodulbau mit nachhaltigem Energie- und Wohnraumkonzept}, series = {Bauphysik}, volume = {44}, journal = {Bauphysik}, number = {3}, publisher = {Ernst \& Sohn}, address = {Hoboken}, issn = {0171-5445 (Print)}, doi = {10.1002/bapi.202200010}, pages = {136 -- 142}, year = {2022}, abstract = {Mit dem Beitrag des Teams der FH Aachen zum SDE 21/22 wird im Projekt LOCAL+ ein kreislauff{\"a}higer Holzmodulbau mit einem innovativen Wohnraumkonzept geplant und umgesetzt. Ziel dieses Konzeptes ist die Verringerung des stetig steigenden Wohnfl{\"a}chenbedarfs durch ein Raum-in-Raum Konzept. Geb{\"a}udetechnisch wird in dem Projekt nicht nur das Einzelgeb{\"a}ude betrachtet, sondern unter Ber{\"u}cksichtigung des Geb{\"a}udebestandes wird f{\"u}r das Quartier ein innovatives und nachhaltiges Energiekonzept entwickelt. Ein zentrales Wasserstoffsystem ist f{\"u}r ein Quartier geplant, um den Stromverbrauch aus dem Netz im Winter zu reduzieren. Zentraler Bestandteil des TGA-Konzepts ist ein unterirdischer Eisspeicher, eine PVT und eine W{\"a}rmepumpe mit intelligenter Regelstrategie. Ein Teil des neuen Geb{\"a}udes (Design Challenge DC) wird in Wuppertal als Hausdemonstrationseinheit (HDU) pr{\"a}sentiert. Eine hygrothermische Simulation der HDU wurde mit der WUFI-Software durchgef{\"u}hrt. Da im Innenraum Lehmmodule und -platten als Feuchtigkeitspuffer verwendet werden, spielen die Themen Feuchtigkeit, Holzf{\"a}ule und Schimmelwachstum eine wichtige Rolle.}, language = {de} } @inproceedings{VaessenAlexopoulosKluczkaetal.2011, author = {Vaeßen, Christiane and Alexopoulos, Spiros and Kluczka, Sven and Sattler, Johannes Christoph and Roeb, M. and Neises, M. and Abdellatif, T.}, title = {Analyse der Verfahren zur solaren Methanolproduktion aus CO2}, series = {Forschung und Entwicklung f{\"u}r solarthermische Kraftwerke : 14. K{\"o}lner Sonnenkolloquium Mittwoch, 13. Juli 2011, im Auditorium des Campus J{\"u}lich der FH Aachen : Kurzfassungen der Vortr{\"a}ge und Poster}, booktitle = {Forschung und Entwicklung f{\"u}r solarthermische Kraftwerke : 14. K{\"o}lner Sonnenkolloquium Mittwoch, 13. Juli 2011, im Auditorium des Campus J{\"u}lich der FH Aachen : Kurzfassungen der Vortr{\"a}ge und Poster}, publisher = {DLR}, address = {K{\"o}ln}, pages = {2 S.}, year = {2011}, language = {de} } @inproceedings{WarerkarSchmitzGoettscheetal.2008, author = {Warerkar, S. and Schmitz, S. and G{\"o}ttsche, Joachim and Hoffschmidt, Bernhard and Tamme, R.}, title = {Performance analysis of an air-sand heat exchanger prototype for high-temperature storage}, series = {EuroSun 2008 : 1st International Conference on Solar Heating, Cooling and Buildings ; 7th - 10th October 2008, Lisbon, Portugal : key lectures / ISES, International Solar Energy Society. Vol. 1}, booktitle = {EuroSun 2008 : 1st International Conference on Solar Heating, Cooling and Buildings ; 7th - 10th October 2008, Lisbon, Portugal : key lectures / ISES, International Solar Energy Society. Vol. 1}, publisher = {Sociedade Portuguesa De Energia Solar (SPES)}, address = {Lissabon}, isbn = {978-1-61782-228-5}, pages = {2215 -- 2222}, year = {2008}, language = {en} } @inproceedings{SattlerAttiAlexopoulosetal.2022, author = {Sattler, Johannes Christoph and Atti, Vikrama and Alexopoulos, Spiros and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf and Dutta, Siddharth and Kioutsioukis, Ioannis}, title = {DNI forecast tool for the smart operation of a parabolic trough collector system with concrete thermal energy storage: Theory, results and outlook}, series = {SolarPACES 2022 conference proceedings}, booktitle = {SolarPACES 2022 conference proceedings}, number = {1}, publisher = {TIB Open Publishing}, address = {Hannover}, issn = {2751-9899 (online)}, doi = {10.52825/solarpaces.v1i.731}, pages = {9 Seiten}, year = {2022}, abstract = {This work presents a basic forecast tool for predicting direct normal irradiance (DNI) in hourly resolution, which the Solar-Institut J{\"u}lich (SIJ) is developing within a research project. The DNI forecast data shall be used for a parabolic trough collector (PTC) system with a concrete thermal energy storage (C-TES) located at the company KEAN Soft Drinks Ltd in Limassol, Cyprus. On a daily basis, 24-hour DNI prediction data in hourly resolution shall be automatically produced using free or very low-cost weather forecast data as input. The purpose of the DNI forecast tool is to automatically transfer the DNI forecast data on a daily basis to a main control unit (MCU). The MCU automatically makes a smart decision on the operation mode of the PTC system such as steam production mode and/or C-TES charging mode. The DNI forecast tool was evaluated using historical data of measured DNI from an on-site weather station, which was compared to the DNI forecast data. The DNI forecast tool was tested using data from 56 days between January and March 2022, which included days with a strong variation in DNI due to cloud passages. For the evaluation of the DNI forecast reliability, three categories were created and the forecast data was sorted accordingly. The result was that the DNI forecast tool has a reliability of 71.4 \% based on the tested days. The result fulfils SIJ's aim to achieve a reliability of around 70 \%, but SIJ aims to still improve the DNI forecast quality.}, language = {en} } @inproceedings{SattlerSchneiderAngeleetal.2022, author = {Sattler, Johannes Christoph and Schneider, Iesse Peer and Angele, Florian and Atti, Vikrama and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf}, title = {Development of heliostat field calibration methods: Theory and experimental test results}, series = {SolarPACES 2022 conference proceedings}, booktitle = {SolarPACES 2022 conference proceedings}, number = {1}, publisher = {TIB Open Publishing}, address = {Hannover}, issn = {2751-9899 (online)}, doi = {10.52825/solarpaces.v1i.678}, pages = {9 Seiten}, year = {2022}, abstract = {In this work, three patent pending calibration methods for heliostat fields of central receiver systems (CRS) developed by the Solar-Institut J{\"u}lich (SIJ) of the FH Aachen University of Applied Sciences are presented. The calibration methods can either operate in a combined mode or in stand-alone mode. The first calibration method, method A, foresees that a camera matrix is placed into the receiver plane where it is subjected to concentrated solar irradiance during a measurement process. The second calibration method, method B, uses an unmanned aerial vehicle (UAV) such as a quadrocopter to automatically fly into the reflected solar irradiance cross-section of one or more heliostats (two variants of method B were tested). The third calibration method, method C, foresees a stereo central camera or multiple stereo cameras installed e.g. on the solar tower whereby the orientations of the heliostats are calculated from the location detection of spherical red markers attached to the heliostats. The most accurate method is method A which has a mean accuracy of 0.17 mrad. The mean accuracy of method B variant 1 is 1.36 mrad and of variant 2 is 1.73 mrad. Method C has a mean accuracy of 15.07 mrad. For method B there is great potential regarding improving the measurement accuracy. For method C the collected data was not sufficient for determining whether or not there is potential for improving the accuracy.}, language = {en} } @inproceedings{KruegerAnthrakidisFischeretal.2009, author = {Kr{\"u}ger, Dirk and Anthrakidis, Anette and Fischer, Stephan and Lokurlu, Ahmet and Walder, Markus and Croy, Reiner and Quaschning, Volker}, title = {Experiences with solar steam supply for an industrial steam network in the P3 Project}, series = {SolarPACES 2009 : electricity, fuels and clean water powered by the sun ; 15 - 18 September 2009, Berlin, Germany ; the 15th SolarPACES conference ; proceedings}, booktitle = {SolarPACES 2009 : electricity, fuels and clean water powered by the sun ; 15 - 18 September 2009, Berlin, Germany ; the 15th SolarPACES conference ; proceedings}, publisher = {Deutsches Zentrum f. Luft- u. Raumfahrt}, address = {Stuttgart}, isbn = {9783000287558}, pages = {1 CD-ROM}, year = {2009}, language = {en} } @inproceedings{BlankeSchmidtGoettscheetal.2022, author = {Blanke, Tobias and Schmidt, Katharina S. and G{\"o}ttsche, Joachim and D{\"o}ring, Bernd and Frisch, J{\´e}r{\^o}me and van Treeck, Christoph}, title = {Time series aggregation for energy system design: review and extension of modelling seasonal storages}, series = {Energy Informatics}, volume = {5}, booktitle = {Energy Informatics}, number = {1, Article number: 17}, editor = {Weidlich, Anke and Neumann, Dirk and Gust, Gunther and Staudt, Philipp and Sch{\"a}fer, Mirko}, publisher = {Springer Nature}, issn = {2520-8942}, doi = {10.1186/s42162-022-00208-5}, pages = {14 Seiten}, year = {2022}, abstract = {Using optimization to design a renewable energy system has become a computationally demanding task as the high temporal fluctuations of demand and supply arise within the considered time series. The aggregation of typical operation periods has become a popular method to reduce effort. These operation periods are modelled independently and cannot interact in most cases. Consequently, seasonal storage is not reproducible. This inability can lead to a significant error, especially for energy systems with a high share of fluctuating renewable energy. The previous paper, "Time series aggregation for energy system design: Modeling seasonal storage", has developed a seasonal storage model to address this issue. Simultaneously, the paper "Optimal design of multi-energy systems with seasonal storage" has developed a different approach. This paper aims to review these models and extend the first model. The extension is a mathematical reformulation to decrease the number of variables and constraints. Furthermore, it aims to reduce the calculation time while achieving the same results.}, language = {en} } @inproceedings{GoettscheHoffschmidtSchmitzetal.2008, author = {G{\"o}ttsche, Joachim and Hoffschmidt, Bernhard and Schmitz, S. and Sauerborn, Markus and Rebholz, C. and Iffland, D. and Badst{\"u}bner, R. and Buck, R. and Teufel, E.}, title = {Test of a mini-mirror array for solar concentrating systems}, series = {EuroSun 2008 : 1st International Conference on Solar Heating, Cooling and Buildings ; 7th - 10th October 2008, Lisbon, Portugal : key lectures / ISES, International Solar Energy Society. Vol. 1}, booktitle = {EuroSun 2008 : 1st International Conference on Solar Heating, Cooling and Buildings ; 7th - 10th October 2008, Lisbon, Portugal : key lectures / ISES, International Solar Energy Society. Vol. 1}, publisher = {Sociedade Portuguesa De Energia Solar (SPES)}, address = {Lissabon}, isbn = {978-1-61782-228-5}, pages = {1242 -- 1250}, year = {2008}, language = {en} } @inproceedings{HerrmannKellyPrice2002, author = {Herrmann, Ulf and Kelly, Bruce and Price, Henry}, title = {Two Tank Molten Salt Storage for Parabolic Trough Solar Power Plants}, series = {Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgen{\"o}ssische Technische Hochschule Z{\"u}rich}, booktitle = {Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgen{\"o}ssische Technische Hochschule Z{\"u}rich}, editor = {Steinfeld, Aldo}, publisher = {Paul Scherrer Inst.}, address = {Villingen}, isbn = {3-9521409-3-7}, pages = {517 -- 524}, year = {2002}, language = {en} } @inproceedings{NeumannAdamBackesetal.2021, author = {Neumann, Hannah and Adam, Mario and Backes, Klaus and B{\"o}rner, Martin and Clees, Tanja and Doetsch, Christian and Glaeser, Susanne and Herrmann, Ulf and May, Johanna and Rosenthal, Florian and Sauer, Dirk Uwe and Stadler, Ingo}, title = {Development of open educational resources for renewable energy and the energy transition process}, series = {ISES SWC 2021}, booktitle = {ISES SWC 2021}, publisher = {International Solar Energy Society}, address = {Freiburg}, doi = {10.18086/swc.2021.47.03}, pages = {6 Seiten}, year = {2021}, abstract = {The dissemination of knowledge about renewable energies is understood as a social task with the highest topicality. The transfer of teaching content on renewable energies into digital open educational resources offers the opportunity to significantly accelerate the implementation of the energy transition. Thus, in the here presented project six German universities create open educational resources for the energy transition. These materials are available to the public on the internet under a free license. So far there has been no publicly accessible, editable media that cover entire learning units about renewable energies extensively and in high technical quality. Thus, in this project, the content that remains up-to-date for a longer period is appropriately prepared in terms of media didactics. The materials enable lecturers to provide students with in-depth training about technologies for the energy transition. In a particular way, the created material is also suitable for making the general public knowledgeable about the energy transition with scientifically based material.}, language = {en} } @inproceedings{SchwagerAngeleSchwarzboezletal.2023, author = {Schwager, Christian and Angele, Florian and Schwarzb{\"o}zl, Peter and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf}, title = {Model predictive assistance for operational decision making in molten salt receiver systems}, series = {SolarPACES: Solar Power \& Chemical Energy Systems}, booktitle = {SolarPACES: Solar Power \& Chemical Energy Systems}, number = {2815 / 1}, publisher = {AIP conference proceedings / American Institute of Physics}, address = {Melville, NY}, isbn = {978-0-7354-4623-6}, issn = {1551-7616 (online)}, doi = {10.1063/5.0151514}, pages = {8 Seiten}, year = {2023}, abstract = {Despite the challenges of pioneering molten salt towers (MST), it remains the leading technology in central receiver power plants today, thanks to cost effective storage integration and high cost reduction potential. The limited controllability in volatile solar conditions can cause significant losses, which are difficult to estimate without comprehensive modeling [1]. This paper presents a Methodology to generate predictions of the dynamic behavior of the receiver system as part of an operating assistance system (OAS). Based on this, it delivers proposals if and when to drain and refill the receiver during a cloudy period in order maximize the net yield and quantifies the amount of net electricity gained by this. After prior analysis with a detailed dynamic two-phase model of the entire receiver system, two different reduced modeling approaches where developed and implemented in the OAS. A tailored decision algorithm utilizes both models to deliver the desired predictions efficiently and with appropriate accuracy.}, language = {en} } @article{PeereBlanke2022, author = {Peere, Wouter and Blanke, Tobias}, title = {GHEtool: An open-source tool for borefield sizing in Python}, series = {Journal of Open Source Software}, volume = {7}, journal = {Journal of Open Source Software}, number = {76}, editor = {Vernon, Chris}, issn = {2475-9066}, doi = {10.21105/joss.04406}, pages = {1 -- 4, 4406}, year = {2022}, abstract = {GHEtool is a Python package that contains all the functionalities needed to deal with borefield design. It is developed for both researchers and practitioners. The core of this package is the automated sizing of borefield under different conditions. The sizing of a borefield is typically slow due to the high complexity of the mathematical background. Because this tool has a lot of precalculated data, GHEtool can size a borefield in the order of tenths of milliseconds. This sizing typically takes the order of minutes. Therefore, this tool is suited for being implemented in typical workflows where iterations are required. GHEtool also comes with a graphical user interface (GUI). This GUI is prebuilt as an exe-file because this provides access to all the functionalities without coding. A setup to install the GUI at the user-defined place is also implemented and available at: https://www.mech.kuleuven.be/en/tme/research/thermal_systems/tools/ghetool.}, language = {en} } @inproceedings{SchwagerAngeleNourietal.2022, author = {Schwager, Christian and Angele, Florian and Nouri, Bijan and Schwarzb{\"o}zl, Peter and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf}, title = {Impact of DNI forecast quality on performance prediction for a commercial scale solar tower: Application of nowcasting DNI maps to dynamic solar tower simulation}, series = {SolarPACES 2022 conference proceedings}, booktitle = {SolarPACES 2022 conference proceedings}, number = {1}, publisher = {TIB Open Publishing}, address = {Hannover}, issn = {2751-9899 (online)}, doi = {10.52825/solarpaces.v1i.675}, pages = {9 Seiten}, year = {2022}, abstract = {Concerning current efforts to improve operational efficiency and to lower overall costs of concentrating solar power (CSP) plants with prediction-based algorithms, this study investigates the quality and uncertainty of nowcasting data regarding the implications for process predictions. DNI (direct normal irradiation) maps from an all-sky imager-based nowcasting system are applied to a dynamic prediction model coupled with ray tracing. The results underline the need for high-resolution DNI maps in order to predict net yield and receiver outlet temperature realistically. Furthermore, based on a statistical uncertainty analysis, a correlation is developed, which allows for predicting the uncertainty of the net power prediction based on the corresponding DNI forecast uncertainty. However, the study reveals significant prediction errors and the demand for further improvement in the accuracy at which local shadings are forecasted.}, language = {en} } @inproceedings{SchulteSchwagerFrantzetal.2022, author = {Schulte, Jonas and Schwager, Christian and Frantz, Cathy and Schloms, Felix and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf}, title = {Control concept for a molten salt receiver in star design: Development, optimization and testing with cloud passage scenarios}, series = {SolarPACES 2022 conference proceedings}, booktitle = {SolarPACES 2022 conference proceedings}, number = {1}, publisher = {TIB Open Publishing}, address = {Hannover}, issn = {2751-9899 (online)}, doi = {10.52825/solarpaces.v1i.693}, pages = {9 Seiten}, year = {2022}, abstract = {A promising approach to reduce the system costs of molten salt solar receivers is to enable the irradiation of the absorber tubes on both sides. The star design is an innovative receiver design, pursuing this approach. The unconventional design leads to new challenges in controlling the system. This paper presents a control concept for a molten salt receiver system in star design. The control parameters are optimized in a defined test cycle by minimizing a cost function. The control concept is tested in realistic cloud passage scenarios based on real weather data. During these tests, the control system showed no sign of unstable behavior, but to perform sufficiently in every scenario further research and development like integrating Model Predictive Controls (MPCs) need to be done. The presented concept is a starting point to do so.}, language = {en} } @inproceedings{LatzkeAlexopoulosKronhardtetal.2015, author = {Latzke, Markus and Alexopoulos, Spiros and Kronhardt, Valentina and Rend{\´o}n, Carlos and Sattler, Johannes Christoph}, title = {Comparison of Potential Sites in China for Erecting a Hybrid Solar Tower Power Plant with Air Receiver}, series = {Energy Procedia}, booktitle = {Energy Procedia}, issn = {1876-6102}, doi = {10.1016/j.egypro.2015.03.142}, pages = {1327 -- 1334}, year = {2015}, language = {en} } @inproceedings{BaumannTeixeiraBouraEcksteinetal.2011, author = {Baumann, Torsten and Teixeira Boura, Cristiano Jos{\´e} and Eckstein, Julian and Felinks, Jan and G{\"o}ttsche, Joachim and Hoffschmidt, Bernhard and Schmitz, Stefan and Zunft, Stefan}, title = {Air-sand heat exchanger}, series = {6th International Renewable Energy Storage Conference (IRES 2011) : November 28 - 30, 2011, bcc Berlin Congress Center, Berlin, Germany / EUROSOLAR ...}, booktitle = {6th International Renewable Energy Storage Conference (IRES 2011) : November 28 - 30, 2011, bcc Berlin Congress Center, Berlin, Germany / EUROSOLAR ...}, publisher = {Eurosolar}, address = {Bonn}, pages = {1 CD-ROM}, year = {2011}, language = {de} } @inproceedings{ChicoCaminosSchmitzAttietal.2022, author = {Chico Caminos, Ricardo Alexander and Schmitz, Pascal and Atti, Vikrama and Mahdi, Zahra and Teixeira Boura, Cristiano Jos{\´e} and Sattler, Johannes Christoph and Herrmann, Ulf and Hilger, Patrick and Dieckmann, Simon}, title = {Development of a micro heliostat and optical qualification assessment with a 3D laser scanning method}, series = {SOLARPACES 2020}, booktitle = {SOLARPACES 2020}, number = {2445 / 1}, publisher = {AIP conference proceedings / American Institute of Physics}, address = {Melville, NY}, isbn = {978-0-7354-4195-8}, issn = {1551-7616 (online)}, doi = {10.1063/5.0086262}, pages = {8 Seiten}, year = {2022}, abstract = {The Solar-Institut J{\"u}lich (SIJ) and the companies Hilger GmbH and Heliokon GmbH from Germany have developed a small-scale cost-effective heliostat, called "micro heliostat". Micro heliostats can be deployed in small-scale concentrated solar power (CSP) plants to concentrate the sun's radiation for electricity generation, space or domestic water heating or industrial process heat. In contrast to conventional heliostats, the special feature of a micro heliostat is that it consists of dozens of parallel-moving, interconnected, rotatable mirror facets. The mirror facets array is fixed inside a box-shaped module and is protected from weathering and wind forces by a transparent glass cover. The choice of the building materials for the box, tracking mechanism and mirrors is largely dependent on the selected production process and the intended application of the micro heliostat. Special attention was paid to the material of the tracking mechanism as this has a direct influence on the accuracy of the micro heliostat. The choice of materials for the mirror support structure and the tracking mechanism is made in favor of plastic molded parts. A qualification assessment method has been developed by the SIJ in which a 3D laser scanner is used in combination with a coordinate measuring machine (CMM). For the validation of this assessment method, a single mirror facet was scanned and the slope deviation was computed.}, language = {en} } @inproceedings{BaumannTeixeiraBouraGoettscheetal.2011, author = {Baumann, Torsten and Teixeira Boura, Cristiano Jos{\´e} and G{\"o}ttsche, Joachim and Hoffschmidt, Bernhard and Schmitz, Stefan and Zunft, Stefan}, title = {Air-sand heat exchanger: materials and flow properties}, series = {SolarPACES 2011 : concentrating solar power and chemical energy systems : 20 - 23 September, 2011, Granada, Spain}, booktitle = {SolarPACES 2011 : concentrating solar power and chemical energy systems : 20 - 23 September, 2011, Granada, Spain}, address = {Granada}, pages = {1 CD-ROM}, year = {2011}, language = {en} } @inproceedings{FrickeZiolkoAnthrakidisetal.2011, author = {Fricke, Barbara and Ziolko, C. and Anthrakidis, Anette and Alexopoulos, Spiros and Hoffschmidt, Bernhard and Dillig, M. and Giese, F.}, title = {InnoSol - life cycle analysis of solar power tower plants}, series = {SolarPACES 2011 : concentrating solar power and chemical energy systems : 20 - 23 September, 2011, Granada, Spain}, booktitle = {SolarPACES 2011 : concentrating solar power and chemical energy systems : 20 - 23 September, 2011, Granada, Spain}, address = {Granada}, pages = {1 CD-ROM}, year = {2011}, language = {en} } @inproceedings{GorzalkaDahlkeGoettscheetal.2018, author = {Gorzalka, Philip and Dahlke, Dennis and G{\"o}ttsche, Joachim and Israel, Martin and Patel, Dhruvkumar and Prahl, Christoph and Schmiedt, Jacob Estevam and Frommholz, Dirk and Hoffschmidt, Bernhard and Linkiewicz, Magdalena}, title = {Building Tomograph-From Remote Sensing Data of Existing Buildings to Building Energy Simulation Input}, series = {EBC, Annex 71, Fifth expert meeting, October 17-19, 2018, Innsbruck, Austria}, booktitle = {EBC, Annex 71, Fifth expert meeting, October 17-19, 2018, Innsbruck, Austria}, pages = {17 Seiten}, year = {2018}, language = {en} } @inproceedings{LahrsKrisamHerrmann2023, author = {Lahrs, Lennart and Krisam, Pierre and Herrmann, Ulf}, title = {Envisioning a collaborative energy system planning platform for the energy transition at the district level}, series = {ECOS 2023. The 36th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems}, booktitle = {ECOS 2023. The 36th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems}, publisher = {Procedings of ECOS 2023}, doi = {10.52202/069564-0284}, pages = {3163 -- 3170}, year = {2023}, abstract = {Residential and commercial buildings account for more than one-third of global energy-related greenhouse gas emissions. Integrated multi-energy systems at the district level are a promising way to reduce greenhouse gas emissions by exploiting economies of scale and synergies between energy sources. Planning district energy systems comes with many challenges in an ever-changing environment. Computational modelling established itself as the state-of-the-art method for district energy system planning. Unfortunately, it is still cumbersome to combine standalone models to generate insights that surpass their original purpose. Ideally, planning processes could be solved by using modular tools that easily incorporate the variety of competing and complementing computational models. Our contribution is a vision for a collaborative development and application platform for multi-energy system planning tools at the district level. We present challenges of district energy system planning identified in the literature and evaluate whether this platform can help to overcome these challenges. Further, we propose a toolkit that represents the core technical elements of the platform. Lastly, we discuss community management and its relevance for the success of projects with collaboration and knowledge sharing at their core.}, language = {en} } @article{HerrmannKearney2002, author = {Herrmann, Ulf and Kearney, David W.}, title = {Survey of Thermal Energy Storage for Parabolic Trough Power Plants}, series = {Journal of Solar Energy Engineering}, volume = {124}, journal = {Journal of Solar Energy Engineering}, number = {2}, issn = {1528-8986 (Online)}, doi = {10.1115/1.1467601}, pages = {145 -- 152}, year = {2002}, language = {en} } @inproceedings{SauerbornLiebenstundRaueetal.2017, author = {Sauerborn, Markus and Liebenstund, Lena and Raue, Markus and Mang, Thomas and Herrmann, Ulf and Dueing, Andreas}, title = {Analytic method for material aging and quality analyzing to forecast long time stability of plastic micro heliostat components}, series = {AIP Conference Proceedings}, volume = {1850}, booktitle = {AIP Conference Proceedings}, number = {1}, doi = {10.1063/1.4984388}, pages = {030045-1 -- 030045-8}, year = {2017}, language = {en} } @article{HerrmannLippke1999, author = {Herrmann, Ulf and Lippke, F.}, title = {The influence of transients on the design of DSG solar fields}, series = {Journal de Physique IV : proceedings}, volume = {9}, journal = {Journal de Physique IV : proceedings}, number = {PR3}, isbn = {2-86883-402-7}, issn = {1764-7177 (Online)}, doi = {10.1051/jp4:1999377}, pages = {489 -- 494}, year = {1999}, language = {en} } @inproceedings{WarerkarSchmitzGoettscheetal.2009, author = {Warerkar, Shashikant and Schmitz, Stefan and G{\"o}ttsche, Joachim and Hoffschmidt, Bernhard and Reißel, Martin and Tamme, Rainer}, title = {Air-sand heat exchanger for high-temperature storage}, series = {Proceedings of the ASME 3rd International Conference on Energy Sustainability : July 19 - 23, 2009, San Francisco, California, USA. Vol. 2}, booktitle = {Proceedings of the ASME 3rd International Conference on Energy Sustainability : July 19 - 23, 2009, San Francisco, California, USA. Vol. 2}, publisher = {ASME}, address = {New York, NY}, isbn = {978-0-7918-4890-6}, pages = {655 -- 661}, year = {2009}, language = {en} } @inproceedings{SchornWeisAnthrakidisetal.2016, author = {Schorn, Christian and Weis, Fabian and Anthrakidis, Anette and Schwarzer, Klemens and Schmitz, Mark and Herrmann, Ulf}, title = {Entwicklung und Bewertung eines Parabolrinnenkollektors zur Prozessw{\"a}rmebereitstellung}, series = {26. Symposium Thermische Solarenergie, 20.-22.04.2016 in Bad Staffelstein}, booktitle = {26. Symposium Thermische Solarenergie, 20.-22.04.2016 in Bad Staffelstein}, pages = {1 -- 13}, year = {2016}, language = {de} } @article{SchwagerFleschSchwarzboezletal.2022, author = {Schwager, Christian and Flesch, Robert and Schwarzb{\"o}zl, Peter and Herrmann, Ulf and Teixeira Boura, Cristiano Jos{\´e}}, title = {Advanced two phase flow model for transient molten salt receiver system simulation}, series = {Solar Energy}, volume = {232}, journal = {Solar Energy}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0038-092X (print)}, doi = {10.1016/j.solener.2021.12.065}, pages = {362 -- 375}, year = {2022}, abstract = {In order to realistically predict and optimize the actual performance of a concentrating solar power (CSP) plant sophisticated simulation models and methods are required. This paper presents a detailed dynamic simulation model for a Molten Salt Solar Tower (MST) system, which is capable of simulating transient operation including detailed startup and shutdown procedures including drainage and refill. For appropriate representation of the transient behavior of the receiver as well as replication of local bulk and surface temperatures a discretized receiver model based on a novel homogeneous two-phase (2P) flow modelling approach is implemented in Modelica Dymola®. This allows for reasonable representation of the very different hydraulic and thermal properties of molten salt versus air as well as the transition between both. This dynamic 2P receiver model is embedded in a comprehensive one-dimensional model of a commercial scale MST system and coupled with a transient receiver flux density distribution from raytracing based heliostat field simulation. This enables for detailed process prediction with reasonable computational effort, while providing data such as local salt film and wall temperatures, realistic control behavior as well as net performance of the overall system. Besides a model description, this paper presents some results of a validation as well as the simulation of a complete startup procedure. Finally, a study on numerical simulation performance and grid dependencies is presented and discussed.}, language = {en} } @inproceedings{SattlerChicoCaminosAttietal.2020, author = {Sattler, Johannes Christoph and Chico Caminos, Ricardo Alexander and Atti, Vikrama Nagababu and {\"U}rlings, Nicolas and Dutta, Siddharth and Ruiz, Victor and Kalogirou, Soteris and Ktistis, Panayiotis and Agathokleous, Rafaela and Alexopoulos, Spiros and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf}, title = {Dynamic simulation tool for a performance evaluation and sensitivity study of a parabolic trough collector system with concrete thermal energy storage}, series = {AIP Conference Proceedings 2303}, booktitle = {AIP Conference Proceedings 2303}, publisher = {American Institute of Physics}, address = {Melville, NY}, issn = {0094-243X}, doi = {10.1063/5.0029277}, pages = {160004}, year = {2020}, language = {de} } @article{BlankeRegerDoeringetal.2021, author = {Blanke, Tobias and Reger, Vitali and D{\"o}ring, Bernd and G{\"o}ttsche, Joachim and Kuhnhenne, Markus}, title = {Koaxiale Stahlenergiepf{\"a}hle}, series = {Stahlbau}, volume = {90. 2021}, journal = {Stahlbau}, number = {6}, publisher = {Wiley}, address = {Weinheim}, pages = {417 -- 424}, year = {2021}, abstract = {Ein entscheidender Teil der Energiewende ist die W{\"a}rmewende im Geb{\"a}udesektor. Ein Schl{\"u}sselelement sind hier W{\"a}rmepumpen. Diese ben{\"o}tigen eine W{\"a}rmequelle, der sie Energie entziehen k{\"o}nnen, um sie auf ein h{\"o}heres Temperaturniveau zu transformieren. Diese W{\"a}rmequelle kann bspw. das Erdreich sein, dessen W{\"a}rme durch Erdsonden erschlossen werden kann. In diesem Beitrag werden in Stahlpf{\"a}hle integrierte Koaxialsonden mit dem Stand der Technik von Erdsonden gleichen Durchmessers bez{\"u}glich ihrer thermischen Leistungsmerkmale verglichen. Die Stahlenergiepf{\"a}hle bieten neben der W{\"a}rmegewinnung weitere Vorteile, da sie auch eine statische Funktion {\"u}bernehmen und r{\"u}ckstandsfrei zur{\"u}ckgebaut werden k{\"o}nnen. Es werden analytische und numerische Berechnungen vorgestellt, um die thermischen Potenziale beider Systeme zu vergleichen. Außerdem wird ein Testaufbau gezeigt, bei dem Stahlenergiepf{\"a}hle in zwei verschiedenen L{\"a}ngen mit vorhandenen g{\"a}ngigen Erdsonden verglichen werden k{\"o}nnen. Die Berechnungen zeigen einen deutlichen thermischen Mehrertrag zwischen 26 \% und 148 \% der Stahlenergiepf{\"a}hle gegen{\"u}ber dem Stand der Technik abh{\"a}ngig vom Erdreich. Die Messergebnisse zeigen einen thermischen Mehrertrag von {\"u}ber 100 \%. Es l{\"a}sst sich also signifikante Erdsondenl{\"a}nge einsparen. Dabei ist zu beachten, dass sich damit der thermisch genutzte Bereich des Erdreichs reduziert, wodurch die thermische Regeneration und/oder das Langzeitverhalten des Erdreichs an Bedeutung gewinnt.}, language = {de} } @article{SchossigDoetschDruecketal.2005, author = {Schossig, Peter and D{\"o}tsch, Christian and Dr{\"u}ck, Harald and G{\"o}ttsche, Joachim and Huenges, Ernst and Kabus, Frank and Tamme, Rainer}, title = {W{\"a}rmespeicher f{\"u}r die Hausenergieversorgung}, series = {W{\"a}rme und K{\"a}lte - Energie aus Sonne und Erde : Jahrestagung des Forschungsverbunds Sonnenenergie in Kooperation mit der Landesinitiative Zukunftsenergie NRW / Stadermann, Gerd, Hrsg.}, journal = {W{\"a}rme und K{\"a}lte - Energie aus Sonne und Erde : Jahrestagung des Forschungsverbunds Sonnenenergie in Kooperation mit der Landesinitiative Zukunftsenergie NRW / Stadermann, Gerd, Hrsg.}, publisher = {Forschungsverbund Sonnenenergie}, address = {Berlin}, pages = {120 -- 125}, year = {2005}, language = {de} } @inproceedings{FrantzBinderBuschetal.2020, author = {Frantz, Cathy and Binder, Matthias and Busch, Konrad and Ebert, Miriam and Heinrich, Andreas and Kaczmarkiewicz, Nadine and Schl{\"o}gl-Knothe, B{\"a}rbel and Kunze, Tobias and Schuhbauer, Christian and Stetka, Markus and Schwager, Christian and Spiegel, Michael and Teixeira Boura, Cristiano Jos{\´e} and Bauer, Thomas and Bonk, Alexander and Eisen, Stefan and Funck, Bernhard}, title = {Basic Engineering of a High Performance Molten Salt Tower Receiver System}, series = {AIP Conference Proceedings}, booktitle = {AIP Conference Proceedings}, doi = {10.1063/5.0085895}, pages = {1 -- 10}, year = {2020}, abstract = {The production of dispatchable renewable energy will be one of the most important key factors of the future energy supply. Concentrated solar power (CSP) plants operated with molten salt as heat transfer and storage media are one opportunity to meet this challenge. Due to the high concentration factor of the solar tower technology the maximum process temperature can be further increased which ultimately decreases the levelized costs of electricity of the technology (LCOE). The development of an improved tubular molten salt receiver for the next generation of molten salt solar tower plants is the aim of this work. The receiver is designed for a receiver outlet temperature up to 600 °C. Together with a complete molten salt system, the receiver will be integrated into the Multi-Focus-Tower (MFT) in J{\"u}lich (Germany). The paper describes the basic engineering of the receiver, the molten salt tower system and a laboratory corrosion setup.}, language = {en} } @inproceedings{KreyerMuellerEsch2020, author = {Kreyer, J{\"o}rg and M{\"u}ller, Marvin and Esch, Thomas}, title = {A Map-Based Model for the Determination of Fuel Consumption for Internal Combustion Engines as a Function of Flight Altitude}, publisher = {DGLR}, address = {Bonn}, doi = {10.25967/490162}, pages = {13 Seiten}, year = {2020}, abstract = {In addition to very high safety and reliability requirements, the design of internal combustion engines (ICE) in aviation focuses on economic efficiency. The objective must be to design the aircraft powertrain optimized for a specific flight mission with respect to fuel consumption and specific engine power. Against this background, expert tools provide valuable decision-making assistance for the customer. In this paper, a mathematical calculation model for the fuel consumption of aircraft ICE is presented. This model enables the derivation of fuel consumption maps for different engine configurations. Depending on the flight conditions and based on these maps, the current and the integrated fuel consumption for freely definable flight emissions is calculated. For that purpose, an interpolation method is used, that has been optimized for accuracy and calculation time. The mission boundary conditions flight altitude and power requirement of the ICE form the basis for this calculation. The mathematical fuel consumption model is embedded in a parent program. This parent program presents the simulated fuel consumption by means of an example flight mission for a representative airplane. The focus of the work is therefore on reproducing exact consumption data for flight operations. By use of the empirical approaches according to Gagg-Farrar [1] the power and fuel consumption as a function of the flight altitude are determined. To substantiate this approaches, a 1-D ICE model based on the multi-physical simulation tool GT-Suite® has been created. This 1-D engine model offers the possibility to analyze the filling and gas change processes, the internal combustion as well as heat and friction losses for an ICE under altitude environmental conditions. Performance measurements on a dynamometer at sea level for a naturally aspirated ICE with a displacement of 1211 ccm used in an aviation aircraft has been done to validate the 1-D ICE model. To check the plausibility of the empirical approaches with respect to the fuel consumption and performance adjustment for the flight altitude an analysis of the ICE efficiency chain of the 1-D engine model is done. In addition, a comparison of literature and manufacturer data with the simulation results is presented.}, language = {en} } @article{ElMoussaouiTalbiAtmaneetal.2020, author = {El Moussaoui, Noureddine and Talbi, Sofian and Atmane, Ilyas and Kassmi, Khalil and Schwarzer, Klemens and Chayeb, Hamid and Bachiri, Najib}, title = {Feasibility of a new design of a Parabolic Trough Solar Thermal Cooker (PSTC)}, series = {Solar Energy}, volume = {201}, journal = {Solar Energy}, number = {Vol. 201 (May 2020)}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0038-092X}, doi = {10.1016/j.solener.2020.03.079}, pages = {866 -- 871}, year = {2020}, abstract = {In this article, we describe the structure, the functioning, and the tests of parabolic trough solar thermal cooker (PSTC). This oven is designed to meet the needs of rural residents, including Urban, which requires stable cooking temperatures above 200 °C. The cooking by this cooker is based on the concentration of the sun's rays on a glass vacuum tube and heating of the oil circulate in a big tube, located inside the glass tube. Through two small tubes, associated with large tube, the heated oil, rise and heats the pot of cooking pot containing the food to be cooked (capacity of 5 kg). This cooker is designed in Germany and extensively tested in Morocco for use by the inhabitants who use wood from forests. During a sunny day, having a maximum solar radiation around 720 W/m2 and temperature ambient around 26 °C, maximum temperatures recorded of the small tube, the large tube and the center of the pot are respectively: 370 °C, 270 °C and 260 °C. The cooking process with food at high (fries, ..), we show that the cooking oil temperature rises to 200 °C, after 1 h of heating, the cooking is done at a temperature of 120 °C for 20 min. These temperatures are practically stable following variations and decreases in the intensity of irradiance during the day. The comparison of these results with those of the literature shows an improvement of 30-50 \% on the maximum value of the temperature with a heat storage that could reach 60 min of autonomy. All the results obtained show the good functioning of the PSTC and the feasibility of cooking food at high temperature (>200 °C).}, language = {en} } @techreport{EschDammKalbhenn2013, author = {Esch, Thomas and Damm, Marc Andr{\´e} and Kalbhenn, Hartmut}, title = {Auslegung und Simulation eines Hybridantriebs f{\"u}r den teilelektrischen Betrieb eines Luftfahrzeuges der allgemeinen Luftfahrt : Schlussbericht f{\"u}r das Forschungsvorhaben ; F{\"o}rderperiode 01.07.2009 - 31.05.2012}, address = {Aachen ; Hannover}, doi = {10.2314/GBV:780055411}, pages = {1 Online-Ressource (138 Seiten)}, year = {2013}, language = {de} } @article{GrossTimmer1998, author = {Groß, Rolf Fritz and Timmer, H.}, title = {Energetische und betriebswirtschaftliche Bewertung von K{\"u}hlsystemen f{\"u}r K{\"u}hllager}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {49}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {9}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {74 -- 77}, year = {1998}, language = {de} } @incollection{ThulfautGrossRenz2000, author = {Thulfaut, Christian and Groß, Rolf Fritz and Renz, Ulrich}, title = {Messwerterfassung und -auswertung mit LabView: Experimentelle Analyse der Mischungsg{\"u}te in Hybridzellenk{\"u}hlt{\"u}rmen}, series = {Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 2000}, booktitle = {Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 2000}, editor = {Jamal, Rahman and Jaschinski, Hans}, publisher = {H{\"u}thig}, address = {Heidelberg}, isbn = {3-7785-2789-4 (print)}, pages = {54 -- 60}, year = {2000}, abstract = {Zur K{\"u}hlung von Abw{\"a}rmestr{\"o}men aus Kraftwerksprozessen werden in zunehmenden Maße Hybridzellenk{\"u}hlt{\"u}rme mit Zwangskonvektion eingesetzt, deren wesentlicher Vorteil ihre geringe Bauh{\"o}he ist. Um bei derartigen K{\"u}hlt{\"u}rmen eine Sichtbehinderung oder Glatteisgef{\"a}hrdung durch bodennahen Nebel zu vermeiden, muss durch eine optimale Vermischung des Trocken- und Naßluftanteils gew{\"a}hrleistet sein, daß aus der K{\"u}hlturmkrone keine Nebelschwaden austreten. In Zusammenarbeit mit der Industrie betreibt der Lehrstuhl f{\"u}r W{\"a}rme{\"u}bertragung und Klimatechnik der RWTH Aachen einen Versuchsstand zur Erfassung der Mischungsg{\"u}te in Hybridzellenk{\"u}hlt{\"u}rmen. In maßstabsgerechter Nachbildung k{\"o}nnen dabei am Modell alle relevanten Einflußgr{\"o}ßen wie K{\"u}hlturmgeometrie, Gestaltung zus{\"a}tzlicher Mischeinbauten sowie die Betriebsparameter variiert werden. Mit Hilfe einer unter LabView 5.01 erstellten Software werden sowohl die l3etriebszust{\"u}ncle online {\"u}berwacht, als auch die ben{\"o}tigten Meßwerte zur Bestimmung der Mischungsg{\"u}te erfaßt. {\"U}ber die grafische Oberfl{\"a}che k{\"o}nnen s{\"a}mtliche Meßoptionen gesteuert sowie alle Meßdaten visualisiert und kontrolliert werden. In das LabView-Programm sind dar{\"u}ber hinaus Routinen zur Auswertung der Daten implementiert worden, die sowohl eine direkte Darstellung der Ergebnisse in Form von Diagrammen erm{\"o}glichen, als auch zur Weiterverarbeitung einen Datenexport in eine Microsoft- Excel-Tabelle vorsehen.}, language = {de} } @incollection{GrossThulfautRenz2000, author = {Groß, Rolf Fritz and Thulfaut, Christian and Renz, Ulrich}, title = {On-Line Simulation mit LabView: Experimentelle und numerische Analyse homogener Gasphasenreaktionen aus Kraftwerksprozessen,}, series = {Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 2000}, booktitle = {Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 2000}, editor = {Jamal, Rahman and Jaschinski, Hans}, publisher = {H{\"u}thig}, address = {Heidelberg}, isbn = {3-7785-2789-4 (print)}, pages = {103 -- 108}, year = {2000}, abstract = {The institute of heat transfer and air conditioning at the Aachen University of Technology operates several test facilities in order to investigate homogeneous and catalytical processes for the reduction of gaseous pollutants (e.g. nitrous oxide) of flue gases in a tempeature range up to 900°C. One test facility consists of a stainless steel reactor in which the influence of reducing additives can be investigated. The software tool, created with LabVIEW 5.01, offers the possibility to measure, visualize and control all relevant physical quantities and to gain a numerical solution of the problem by solving the one dimensional, steady state conservation equations.}, language = {de} } @techreport{ChristGrossRenz1998, author = {Christ, Ansgar and Groß, Rolf Fritz and Renz, Ulrich}, title = {Str{\"o}mungs-, Filterkuchen- und Abreinigungsmodelle f{\"u}r Heißgasfilter, Teilvorhaben "Numerische Simulation des Abreinigungsvorganges und der Rohgasstr{\"o}mung"}, doi = {10.2314/GBV:50431601X}, pages = {117 Seiten}, year = {1998}, language = {de} } @incollection{DautzenbergGrossRenz1996, author = {Dautzenberg, H. and Groß, Rolf Fritz and Renz, Ulrich}, title = {Meßtechnik auf dem Pr{\"u}fstand: Forschung zur Heißgasfiltration}, series = {Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 1996}, booktitle = {Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 1996}, editor = {Jamal, Rahman}, publisher = {National Instruments Germany}, address = {M{\"u}nchen}, pages = {202 -- 208}, year = {1996}, abstract = {Im Rahmen von Forschungsvorhaben des BMBF und verschiedener Industriepartner betreibt der Lehrstuhl f{\"u}r W{\"a}rme{\"u}bertragung und Klimatechnik der RWTH Aachen Pilotanlagen und Pr{\"u}fst{\"a}nde f{\"u}r Untersuchungen auf dem Gebiet der Heißgasfiltration mit keramischen Filterelementen. Als wesentlicher Garant f{\"u}r den Erfolg der Forschungsarbeit muß die auf das jeweilige Projekt genau abgestimmte Meß- und Regelungstechnik angesehen werden. Hierbei z{\"a}hlt neben der Auswahl geeigneter Hardwarekomponenten auch die Softwareentwicklung unter einer leistungsstarken und zuverl{\"a}ssigen Programmierumgebung. Anhand des Aufbaus dreier Versuchsanlagen im Technikumsmaßstab soll das Anforderungsprofil an die Meßtechnik bis hin zur Umsetzung innerhalb der Anlage skizziert werden. Der Heißgasfiltrationspr{\"u}fstand im Heizkraftwerk der RWTH Aachen dient der Beobachtung des Reinigungsverhaltens keramischer Filterelemente bei der Heißgasentstaubung im Temperaturbereich bis 850 Grad C. Wesentlich f{\"u}r die Meßwerterfassung ist hierbei die Kopplung eines Orion-Datenloggers der Firma Schlumberger mit LabView 4.0. Im Hochtemperaturofen des Lehrstuhls werden instation{\"a}re Druckmessungen an einer keramischen Filterkerze w{\"a}hrend eines Abreinigungsimpulses bei 950 Grad C mit hoher Samplingrate durchgef{\"u}hrt. Hierbei {\"u}bernimmt eine durch LabView 4.0 angesteuerte E-Series Karte der Firma National Instruments die Signalaufnahme. Die katalytische Schadstoffreduktion und Entstaubung heißer Rauchgase bei 900 Grad C sind Ziele der Untersuchungen in einer erstellten Versuchsanlage mit einem Quarzglasreaktor. Die Signalerfassung und -konditionierung erfolgt {\"u}ber SCXI in Verbindung mit LabView 4.0, die Steuerung der Anlage {\"u}bernehmen zwei Multifunktionskarten (National Instruments).}, language = {de} } @incollection{GrossMuellerHertingetal.1997, author = {Groß, Rolf Fritz and M{\"u}ller, D. and Herting, D. and Schneemann, A. and Renz, Ulrich}, title = {Modulare Messdatenerfassung in Forschung und Lehre}, series = {Virtuelle Instrumente in der Praxis : Begleitband zum Kongress VIP '97}, booktitle = {Virtuelle Instrumente in der Praxis : Begleitband zum Kongress VIP '97}, editor = {Rahman, Jamal and Jaschinski, Hans}, publisher = {H{\"u}thig}, address = {Heidelberg}, isbn = {978-3-7785-2667-5 Pp.}, pages = {282 -- 288}, year = {1997}, abstract = {The Lehrstuhl f{\"u}r W{\"a}rme{\"u}bertragung und Klimatechnik at the Aachen University of Technology operates several test facilities to investigate fundamentals of heat and mass transfer supported by the Deutsche Forschungsgemeinschaft, the Minister f{\"u}r Forschung und Technologie and the industry. In order to get high-resolution and reproselection of hardware components is as critical as the design of software routines to perform successful and accurate measurements. In the following the development of the measurement and control system for three different test facilities is presented and discussed. Special attention is given to the education of students within the framework of laboratories and scientific experiments.}, language = {de} } @techreport{AyarFielenbachGrossetal.2003, author = {Ayar, A. and Fielenbach, C. and Groß, Rolf Fritz and Holfeld, T. and Lockemann, S. and Severin, C. and Thulfaut, Christian and Hillemacher, B.}, title = {Druckkohlenstaubverbrennung von rheinischer Braunkohle : Abschlussbericht}, pages = {119 Seiten}, year = {2003}, abstract = {Im Rahmen des Forschungsschwerpunkts 3 wurde experimentell und theoretisch die NO{sub x}-Bildung und -Reduktion bei der Druckkohlenstaubverbrennung untersucht. Der zuvor beschriebene Einfluss der Kohlemahlung auf die Flamme konnte auch anhand der NO{sub x}-Messungen an der DKSF-Anlage Aachen bestaetigt werden. Waehrend mit Braunkohle im Staubfeuerungsbetrieb noch keine eindeutige Druckabhaengigkeit nachgewiesen werden konnte, haben vom Lehrstuhl durchgefuehrte NO{sub x}-Messungen an der DKSF-Anlage Dorsten im Schmelzkammerfeuerungsbetrieb mit der Steinkohle Spitzbergen zwischen 9 und 13 bar ein Absinken der Stickoxidkonzentrationen mit steigendem Druck ergeben. Fuer die rheinische Braunkohle soll dieser Druckeinfluss in den naechsten Versuchsfahrten ausfuehrlicher untersucht werden. Es wurde anhand von numerischen Simulationen zu einer Braunkohleflamme der 6. Versuchsfahrt ein Vergleich zwischen der NO{sub x}-Modellierung im Standard-FLUENT-Code und in dem mit User Defined Subroutines der international flame research foundation (IFRF), Ijmuiden, erweiterten FLUENT-Code vorgenommen. Es zeigte sich, dass bei der Modellierung der Stickoxidbildung die unterschiedlich vorhergesagten Flammentemperaturen eine entscheidende Rolle spielen. Eine genauere Analyse der NO{sub x}-Modelle im Vergleich zu Messergebnissen ist bei einer Schmelzkammerfeuerung mit einer stabilen Flamme vorzunehmen. Es wurden zusaetzlich Messungen zur Untersuchung der Kinetik homogener Gasphasenreaktionen in Rauchgasen an einem Stahlreaktor durchgefuehrt. Dabei wurde sowohl der thermisch bedingte als auch der durch zudosierte Additive katalysierte Abbau nitroser Komponenten betrachtet. Vergleichend wurden mit einem am Lehrstuhl entwickelten Programm die Kinetik beschrieben. Hierbei wird mit einer Sensitivitaetsanalyse eine Reduzierung der detaillierten Darstellung der Reaktionskinetik erreicht, die es erlaubt, mit einem CFD-Code wie FLUENT zwei- und dreidimensionale Rechnungen zum Abbau verschiedener Rauchgaskomponenten durchzufuehren. Die Uebereinstimmung zwischen ein- und zweidimensionalen Rechnungen und den Messungen ist gut.}, language = {de} } @article{ThulfautGross2000, author = {Thulfaut, Christian and Groß, Rolf Fritz}, title = {Experimentelle Untersuchung der Luftstromvermischung in Hybridzellenk{\"u}hlt{\"u}rmen}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {51}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {8}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {48 -- 49}, year = {2000}, abstract = {Zwangsbel{\"u}ftete Nassk{\"u}hlt{\"u}rme haben im Gegensatz zur Trockenk{\"u}hlung bei naßkaltem Wetter Nebelschwaden zur Folge. Dagegen ist bei Naßk{\"u}hlung die spezifische K{\"u}hlleistung durch abgef{\"u}hrte Kondensationsw{\"a}rme h{\"o}her als bei der Trockenk{\"u}hlung. Hybridzellenk{\"u}hlt{\"u}rme kombinieren beide Methoden, so daß ein Mischstrom beider Abluftstr{\"o}me die Wasserdampf-S{\"a}ttigungsgrenze nicht {\"u}berschreitet. Durch das Mischungsverh{\"a}ltnis kann man den gew{\"u}nschten S{\"a}ttigungsgrad einstellen. Je dichter dieser an der S{\"a}ttigungsgrenze liegt, desto h{\"o}her ist die K{\"u}hlleistung. Der von unten zugef{\"u}hrte Luftstrom der Naßk{\"u}hlung und der seitlich zugef{\"u}hrte trockene Abluftstrom m{\"u}ssen sehr gut durchmischt werden, um {\"u}ber den gesamten Austrittsquerschnitt des K{\"u}hlturms die S{\"a}ttigungsgrenze nicht zu {\"u}berschreiten. In einem maßstabsgerechten Modell wurde der Mischungsgrad mit und ohne Einbauten untersucht. {\"U}ber ein Raster von 10 mal 10 Punkten wurde die {\"o}rtliche Temperaturverteilung ermittelt. W{\"a}rmebilanzen ergeben dann die Mischungsg{\"u}te in einer Ebene oberhalb der Zellenkrone. W{\"a}hrend ohne Mischeinbauten der Trockenluftanteil in der Mitte des Querschnitts bei unter 15 \% liegt erh{\"o}hen Einbauten den Trockenluftanteil auf 30 \% bis {\"u}ber 40 \%. Dabei wurde die Trockenluft auf jeder K{\"u}hlturmseite durch 4 konisch zulaufende, unten offene und oben geschlitzte Einbauten kanalisiert. Die Nassluft wurde durch eine im Querschnitt dreieckige Rinne in Richtung der Trockenluftausl{\"a}sse umgelenkt. Im Raster leicht zu lokalisierende Abweichungen vom gew{\"u}nschten Mittelwert zeigen Potential f{\"u}r die weitere Verbesserung der Einbauten.}, language = {de} }