@article{LagemaatMaasVosetal.2015, author = {Lagemaat, Miriam W. and Maas, Marnix C. and Vos, Eline K. and Bitz, Andreas and Orzada, Stephan and Weiland, Elisabeth and Uden, Mark J. van and Kobus, Thiele and Heerschap, Arend and Scheenen, Tom W. J.}, title = {(31) P MR spectroscopic imaging of the human prostate at 7 T: T1 relaxation times, Nuclear Overhauser Effect, and spectral characterization}, series = {Magnetic Resonance in Medicine}, volume = {73}, journal = {Magnetic Resonance in Medicine}, number = {3}, publisher = {Wiley}, address = {Weinheim}, issn = {1522-2594}, doi = {10.1002/mrm.25209}, pages = {909 -- 920}, year = {2015}, language = {en} } @article{FaganBitzBjoerkmanBurtscheretal.2021, author = {Fagan, Andrew J. and Bitz, Andreas and Bj{\"o}rkman-Burtscher, Isabella M. and Collins, Christopher M. and Kimbrell, Vera and Raaijmakers, Alexander J. E.}, title = {7T MR Safety}, series = {Journal of Magnetic Resonance Imaging (JMRI)}, volume = {53}, journal = {Journal of Magnetic Resonance Imaging (JMRI)}, number = {2}, publisher = {Wiley}, address = {Weinheim}, issn = {1522-2586}, doi = {10.1002/jmri.27319}, pages = {333 -- 346}, year = {2021}, language = {en} } @article{SchiffelsSelmer2015, author = {Schiffels, Johannes and Selmer, Thorsten}, title = {A flexible toolbox to study protein-assisted metalloenzyme assembly in vitro}, series = {Biotechnology and Bioengineering}, volume = {112}, journal = {Biotechnology and Bioengineering}, number = {11}, publisher = {Wiley}, address = {Weinheim}, issn = {1097-0290}, doi = {10.1002/bit.25658}, pages = {2360 -- 2372}, year = {2015}, language = {en} } @article{MorenoiCodinachsBirkenstockGarmaetal.2009, author = {Moreno i Codinachs, L. and Birkenstock, C. and Garma, T. and Zierold, R. and Bachmann, J. and Nielsch, K. and Sch{\"o}ning, Michael Josef and Fontcuberta i Morral, A.}, title = {A micron-sized nanoporous multifunction sensing device}, series = {physica status solidi (a) . 206 (2009), H. 3}, journal = {physica status solidi (a) . 206 (2009), H. 3}, publisher = {Wiley}, address = {Weinheim}, isbn = {1862-6319}, pages = {435 -- 441}, year = {2009}, language = {en} } @article{ThielMufflerTippkoetteretal.2015, author = {Thiel, Alexander and Muffler, Kai and Tippk{\"o}tter, Nils and Suck, Kirstin and Sohling, Ulrich and Hruschka, Steffen M. and Ulber, Roland}, title = {A novel integrated downstream processing approach to recover sinapic acid, phytic acid and proteins from rapeseed meal}, series = {Journal of Chemical Technology and Biotechnology}, volume = {90}, journal = {Journal of Chemical Technology and Biotechnology}, number = {11}, publisher = {Wiley}, address = {Weinheim}, doi = {10.1002/jctb.4664}, pages = {1999 -- 2006}, year = {2015}, abstract = {BACKGROUND Currently, several techniques exist for the downstream processing of protein, phytic acid and sinapic acid from rapeseed and rapeseed meal, but no technique has been developed to separate all of the components in one process. In this work, two new downstream processing strategies focusing on recovering sinapic acid, phytic acid and protein from rapeseed meal were established. RESULTS The sinapic acid content was enhanced by a factor of 4.5 with one method and 5.1 with the other. The isolation of sinapic acid was accomplished using a zeolite-based adsorbent with high adsorptive and optimal desorption characteristics. Phytic acid was isolated using the anion-exchange resin Purolite A200®. In addition, the processes resulted in two separated protein fractions. The ratios of globulin and albumin ratio to the total protein were 59.2\% and 40.1\%, respectively. The steps were then combined in two different ways: (a) a 'sequential process' using the zeolite and A200 in batch processes; and (b) a 'parallel process' using only A200 in a chromatographic system to separate all of the compounds. CONCLUSIONS It can be concluded that isolation of all three components was possible in both processes. These could enhance the added value of current processes using rapeseed meal as a protein source. © 2015 Society of Chemical Industry}, language = {en} } @article{AridaTurekRolkaetal.2009, author = {Arida, Hassan and Turek, Monika and Rolka, David and Sch{\"o}ning, Michael Josef}, title = {A Novel Thin-Film Copper Array Based on an Organic/Inorganic Sensor Hybrid: Microfabrication, Potentiometric Characterization, and Flow-Injection Analysis Application}, series = {Electroanalysis. 21 (2009), H. 10}, journal = {Electroanalysis. 21 (2009), H. 10}, publisher = {Wiley}, address = {Weinheim}, isbn = {1040-0397}, pages = {1145 -- 1151}, year = {2009}, language = {en} } @article{BaeckerPouyeshmanSchnitzleretal.2011, author = {B{\"a}cker, Matthias and Pouyeshman, S. and Schnitzler, Thomas and Poghossian, Arshak and Wagner, Patrick and Biselli, Manfred and Sch{\"o}ning, Michael Josef}, title = {A silicon-based multi-sensor chip for monitoring of fermentation processes}, series = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, journal = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, publisher = {Wiley}, address = {Weinheim}, isbn = {1862-6319}, pages = {1364 -- 1369}, year = {2011}, language = {en} } @article{AlexopoulosHoffschmidt2017, author = {Alexopoulos, Spiros and Hoffschmidt, Bernhard}, title = {Advances in solar tower technology}, series = {Wiley interdisciplinary reviews : Energy and Environment : WIREs}, volume = {6}, journal = {Wiley interdisciplinary reviews : Energy and Environment : WIREs}, number = {1}, publisher = {Wiley}, address = {Weinheim}, issn = {2041-840X}, doi = {10.1002/wene.217}, pages = {1 -- 19}, year = {2017}, language = {en} } @article{RietschPfaffenrotBitzetal.2017, author = {Rietsch, Stefan H. G. and Pfaffenrot, Viktor and Bitz, Andreas and Orzada, Stephan and Brunheim, Sascha and Lazik-Palm, Andrea and Theysohn, Jens M. and Ladd, Mark E. and Quick, Harald H. and Kraff, Oliver}, title = {An 8-channel transceiver 7-channel receive RF coil setup for high SNR ultrahigh-field MRI of the shoulder at 7T}, series = {Medical Physics}, journal = {Medical Physics}, number = {Article in press}, publisher = {Wiley}, address = {Hoboken}, issn = {0094-2405}, doi = {10.1002/mp.12612}, year = {2017}, language = {en} } @article{KraffBitzDammannetal.2010, author = {Kraff, Oliver and Bitz, Andreas and Dammann, Philipp and Ladd, Susanne C. and Ladd, Mark E. and Quick, Harald H.}, title = {An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T}, series = {Medical Physics}, volume = {37}, journal = {Medical Physics}, number = {12}, publisher = {Wiley}, address = {Hoboken, NJ}, issn = {2473-4209}, doi = {10.1118/1.3517176}, pages = {6368 -- 6376}, year = {2010}, abstract = {Purpose: MRI plays a leading diagnostic role in assessing the musculoskeletal (MSK) system and is well established for most questions at clinically used field strengths (up to 3 T). However, there are still limitations in imaging early stages of cartilage degeneration, very fine tendons and ligaments, or in locating nerve lesions, for example. 7 T MRI of the knee has already received increasing attention in the current published literature, but there is a strong need to develop new radiofrequency (RF) coils to assess more regions of the MSK system. In this work, an eight-channel transmit/receive RF array was built as a multipurpose coil for imaging some of the thus far neglected regions. An extensive coil characterization protocol and first in vivo results of the human wrist, shoulder, elbow, knee, and ankle imaged at 7 T will be presented. Methods: Eight surface loop coils with a dimension ofurn:x-wiley:00942405:media:mp7176:mp7176-math-0001 were machined from FR4 circuit board material. To facilitate easy positioning, two coil clusters, each with four loop elements, were combined to one RF transmit/receive array. An overlapped and shifted arrangement of the coil elements was chosen to reduce the mutual inductance between neighboring coils. A phantom made of body-simulating liquid was used for tuning and matching on the bench. Afterward, the S-parameters were verified on a human wrist, elbow, and shoulder. For safety validation, a detailed compliance test was performed including full wave simulations of the RF field distribution and the corresponding specific absorption rate (SAR) for all joints. In vivo images of four volunteers were assessed with gradient echo and spin echo sequences modified to obtain optimal image contrast, full anatomic coverage, and the highest spatial resolution within a reasonable acquisition time. The performance of the RF coil was additionally evaluated by in vivo B1 mapping. Results: A comparison of B1 per unit power, flip angle distribution, and anatomic images showed a fairly homogeneous excitation for the smaller joints (elbow, wrist, and ankle), while for the larger joints, the shoulder and especially the knee, B1 inhomogeneities and limited penetration depth were more pronounced. However, the greater part of the shoulder joint could be imaged.In vivo images rendered very fine anatomic details such as fascicles of the median nerve and the branching of the nerve bundles. High-resolution images of cartilage, labrum, and tendons could be acquired. Additionally, turbo spin echo (TSE) and inversion recovery sequences performed very well. Conclusions: This study demonstrates that the concept of two four-channel transmit/receive RF arrays can be used as a multipurpose coil for high-resolutionin vivo MR imaging of the musculoskeletal system at 7 T. Not only gradient echo but also typical clinical and SAR-intensive sequences such as STIR and TSE performed well. Imaging of small structures and peripheral nerves could in particular benefit from this technique.}, language = {en} }