@article{KotliarHanssenEberhardtetal.2013, author = {Kotliar, Konstantin and Hanssen, Henner and Eberhardt, Karla and Vilser, Walthard and Schmaderer, Christoph and Halle, Martin and Heemann, Uwe and Baumann, M.}, title = {Retinal pulse wave velocity in young male normotensive and mildly hypertensive subjects}, series = {Microcirculation}, journal = {Microcirculation}, publisher = {Wiley}, address = {Malden}, issn = {1549-8719}, year = {2013}, language = {en} } @article{JahnkeMenzelDusschotenetal.2009, author = {Jahnke, Siegfried and Menzel, Marion I. and Dusschoten, Dagmar van and Roeb, Gerhard W. and B{\"u}hler, Jonas and Minwuyelet, Senay and Bl{\"u}mler, Peter and Temperton, Vicky M. and Hombach, Thomas and Streun, Matthias and Beer, Simone and Khodaverdi, Maryam and Ziemons, Karl and Coenen, Heinz H. and Schurr, Ulrich}, title = {Combined MRI-PET dissects dynamic changes in plant structures and functions}, series = {The Plant Journal}, volume = {59}, journal = {The Plant Journal}, number = {4}, publisher = {Wiley}, address = {Weinheim}, isbn = {1365-313X}, pages = {634 -- 644}, year = {2009}, abstract = {Unravelling the factors determining the allocation of carbon to various plant organs is one of the great challenges of modern plant biology. Studying allocation under close to natural conditions requires non-invasive methods, which are now becoming available for measuring plants on a par with those developed for humans. By combining magnetic resonance imaging (MRI) and positron emission tomography (PET), we investigated three contrasting root/shoot systems growing in sand or soil, with respect to their structures, transport routes and the translocation dynamics of recently fixed photoassimilates labelled with the short-lived radioactive carbon isotope 11C. Storage organs of sugar beet (Beta vulgaris) and radish plants (Raphanus sativus) were assessed using MRI, providing images of the internal structures of the organs with high spatial resolution, and while species-specific transport sectoralities, properties of assimilate allocation and unloading characteristics were measured using PET. Growth and carbon allocation within complex root systems were monitored in maize plants (Zea mays), and the results may be used to identify factors affecting root growth in natural substrates or in competition with roots of other plants. MRI-PET co-registration opens the door for non-invasive analysis of plant structures and transport processes that may change in response to genomic, developmental or environmental challenges. It is our aim to make the methods applicable for quantitative analyses of plant traits in phenotyping as well as in understanding the dynamics of key processes that are essential to plant performance.}, language = {en} } @article{KirchnerOberlaenderSusoetal.2013, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Suso, Henri-Pierre and Rysstad, Gunnar and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Towards a wireless sensor system for real-time H2O2 monitoring in aseptic food processes}, series = {Physica status solidi (a)}, volume = {210}, journal = {Physica status solidi (a)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201200920}, pages = {877 -- 883}, year = {2013}, abstract = {A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests.}, language = {en} } @article{JensKaldenhoffKirschnerHermannsetal.2014, author = {Jens, Otto and Kaldenhoff, E. and Kirschner-Hermanns, R. and M{\"u}hl, Thomas and Klinge, Uwe}, title = {Elongation of textile pelvic floor implants under load is related to complete loss of effective porosity, thereby favoring incorporation in scar plates}, series = {Journal of biomedical materials research. Part A}, volume = {102}, journal = {Journal of biomedical materials research. Part A}, number = {4}, publisher = {Wiley}, address = {New York}, issn = {1552-4965}, doi = {10.1002/jbm.a.34767}, pages = {1079 -- 1084}, year = {2014}, abstract = {Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift® and Prolift + M®, developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4®, which was designed for pelvic floor repair to withstand mechanical strain. Prolift® at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift + M® revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4® preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift® and Prolift + M® can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome.}, language = {en} } @article{HaselgruberMautnerThiele2010, author = {Haselgruber, Nikolaus and Mautner, Karin and Thiele, Jan}, title = {Usage Space Analysis for Reliability Testing}, series = {Quality and Reliability Engineering International}, volume = {26}, journal = {Quality and Reliability Engineering International}, number = {8}, publisher = {Wiley}, address = {New York}, issn = {1099-1638}, doi = {10.1002/qre.1155}, pages = {877 -- 885}, year = {2010}, abstract = {During the development process of a complex technical product, one widely used and important technique is accelerated testing where the applied stress on a component is chosen to exceed the reference stress, i.e. the stress encountered in field operation, in order to reduce the time to failure. For that, the reference stress has to be known. Since a complex technical product may fail regarding numerous failure modes, stress in general is highly dimensional rather than scalar. In addition, customers use their products individually, i.e. field operation should be described by a distribution rather than by one scalar stress value. In this paper, a way to span the customer usage space is shown. It allows the identification of worst case reference stress profiles in significantly reduced dimensions with minimal loss of information. The application example shows that even for a complex product like a combustion engine, stress information can be compressed significantly. With low measurement effort it turned out that only three reference stress cycles were sufficient to cover a broad range of customer stress variety.}, language = {en} } @article{OehlschlaegerQuettingAlvarezetal.2009, author = {{\"O}hlschl{\"a}ger, Peter and Quetting, Michael and Alvarez, Gerardo and D{\"u}rst, Matthias and Gissmann, Lutz and Kaufmann, Andreas M.}, title = {Enhancement of immunogenicity of a therapeutic cervical cancer DNA-based vaccine by co-application of sequence-optimized genetic adjuvants}, series = {International Journal of Cancer}, volume = {125}, journal = {International Journal of Cancer}, number = {1}, publisher = {Wiley}, address = {Weinheim}, isbn = {1097-0215}, pages = {189 -- 198}, year = {2009}, language = {en} } @article{OosterhuisOehlschlaegerBergetal.2011, author = {Oosterhuis, Koen and {\"O}hlschl{\"a}ger, Peter and Berg, Joost H. van den and Toebes, Mireille and Gomez, Raquel and Schumacher, Ton N. and Haanen, John B.}, title = {Preclinical development of highly effective and safe DNA vaccines directed against HPV 16 E6 and E7}, series = {International Journal of Cancer}, volume = {129}, journal = {International Journal of Cancer}, number = {2}, publisher = {Wiley}, address = {Weinheim}, isbn = {1097-0215}, pages = {397 -- 406}, year = {2011}, language = {en} } @article{OehlschlaegerSpiesAlvarezetal.2011, author = {{\"O}hlschl{\"a}ger, Peter and Spies, Elmar and Alvarez, Gerardo and Quetting, Michael and Groettrup, Marcus}, title = {The combination of TLR-9 adjuvantation and electroporation-mediated delivery enhances in vivo antitumor responses after vaccination with HPV-16 E7 encoding DNA}, series = {International Journal of Cancer. 128 (2011), H. 2}, journal = {International Journal of Cancer. 128 (2011), H. 2}, publisher = {Wiley}, address = {Weinheim}, isbn = {1097-0215}, pages = {473 -- 481}, year = {2011}, language = {en} } @article{LeursMezoOehlschlaegeretal.2012, author = {Leurs, Ulrike and Mezo, Gabor and {\"O}hlschl{\"a}ger, Peter and Orban, Erika and Marquard, Andrea and Manea, Marilena}, title = {Design, synthesis, in vitro stability and cytostatic effect of multifunctional anticancer drug-bioconjugates containing GnRH-III as a targeting moiety}, series = {Peptide Science}, volume = {98}, journal = {Peptide Science}, number = {1}, publisher = {Wiley}, address = {New York, NY}, issn = {1097-0282}, doi = {10.1002/bip.21640}, pages = {1 -- 10}, year = {2012}, abstract = {Bioconjugates containing the GnRH-III hormone decapeptide as a targeting moiety are able to deliver chemotherapeutic agents specifically to cancer cells expressing GnRH receptors, thereby increasing their local efficacy while limiting the peripheral toxicity. However, the number of GnRH receptors on cancer cells is limited and they desensitize under continuous hormone treatment. A possible approach to increase the receptor mediated tumor targeting and consequently the cytostatic effect of the bioconjugates would be the attachment of more than one chemotherapeutic agent to one GnRH-III molecule. Here we report on the design, synthesis and biochemical characterization of multifunctional bioconjugates containing GnRH-III as a targeting moiety and daunorubicin as a chemotherapeutic agent. Two different drug design approaches were pursued. The first one was based on the bifunctional [4Lys]-GnRH-III (Glp-His-Trp-Lys-His-Asp-Trp-Lys-Pro-Gly-NH2) containing two lysine residues in positions 4 and 8, whose ϵ-amino groups were used for the coupling of daunorubicin. In the second drug design, the native GnRH-III (Glp-His-Trp-Ser-His-Asp-Trp-Lys-Pro-Gly-NH2) was used as a scaffold; an additional lysine residue was coupled to the ϵ-amino group of 8Lys in order to generate two free amino groups available for conjugation of daunorubicin. The in vitro stability/degradation of all synthesized compounds was investigated in human serum, as well as in the presence of rat liver lysosomal homogenate. Their cellular uptake was determined on human breast cancer cells and the cytostatic effect was evaluated on human breast, colon and prostate cancer cell lines. Compared with a monofunctional compound, both drug design approaches resulted in multifunctional bioconjugates with increased cytostatic effect.}, language = {en} } @article{PieperKlein2010, author = {Pieper, Martin and Klein, Peter}, title = {Numerical solution of the heat equation with non-linear, time derivative-dependent source term}, series = {International Journal for Numerical Methods in Engineering}, volume = {84}, journal = {International Journal for Numerical Methods in Engineering}, number = {10}, publisher = {Wiley}, address = {Chichester}, issn = {0029-5981}, doi = {10.1002/nme.2937}, pages = {1205 -- 1221}, year = {2010}, abstract = {The mathematical modeling of heat conduction with adsorption effects in coated metal structures yields the heat equation with piecewise smooth coefficients and a new kind of source term. This term is special, because it is non-linear and furthermore depends on a time derivative. In our approach we reformulated this as a new problem for the usual heat equation, without source term but with a new non-linear coefficient. We gave an existence and uniqueness proof for the weak solution of the reformulated problem. To obtain a numerical solution, we developed a semi-implicit and a fully implicit finite volume method. We compared these two methods theoretically as well as numerically. Finally, as practical application, we simulated the heat conduction in coated aluminum fibers with adsorption in the zeolite coating. Copyright © 2010 John Wiley \& Sons, Ltd.}, language = {en} } @article{Pieper2011, author = {Pieper, Martin}, title = {Multiobjective optimization with expensive objectives applied to a thermodynamic material design problem}, series = {Proceedings in applied mathematics and mechanics : PAMM. 11 (2011), H. 1}, journal = {Proceedings in applied mathematics and mechanics : PAMM. 11 (2011), H. 1}, publisher = {Wiley}, address = {Weinheim}, isbn = {1617-7061}, pages = {733 -- 734}, year = {2011}, language = {en} } @article{SchusserLeinhosBaeckeretal.2013, author = {Schusser, Sebastian and Leinhos, Marcel and B{\"a}cker, Matthias and Poghossian, Arshak and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Impedance spectroscopy: A tool for real-time in situ monitoring of the degradation of biopolymers}, series = {Physica Status Solidi (A)}, volume = {210}, journal = {Physica Status Solidi (A)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1521-396X ; 0031-8965}, doi = {10.1002/pssa.201200941}, pages = {905 -- 910}, year = {2013}, abstract = {Investigation of the degradation kinetics of biodegradable polymers is essential for the development of implantable biomedical devices with predicted biodegradability. In this work, an impedimetric sensor has been applied for real-time and in situ monitoring of degradation processes of biopolymers. The sensor consists of two platinum thin-film electrodes covered by a polymer film to be studied. The benchmark biomedical polymer poly(D,L-lactic acid) (PDLLA) was used as a model system. PDLLA films were deposited on the sensor structure from a polymer solution by using the spin-coating method. The degradation kinetics of PDLLA films have been studied in alkaline solutions of pH 9 and 12 by means of an impedance spectroscopy (IS) method. Any changes in a polymer capacitance/resistance induced by water uptake and/or polymer degradation will modulate the global impedance of the polymer-covered sensor that can be used as an indicator of the polymer degradation. The degradation rate can be evaluated from the time-dependent impedance spectra. As expected, a faster degradation has been observed for PDLLA films exposed to pH 12 solution.}, language = {en} } @article{MuribGrinsvenGrietenetal.2013, author = {Murib, M. S. and Grinsven, B. van and Grieten, L. and Janssens, S. D. and Vermeeren, V. and Eersels, K. and Broeders, J. and Ameloot, M. and Michiels, L. and Ceuninck, W. De and Haenen, K. and Sch{\"o}ning, Michael Josef and Wagner, Patrick}, title = {Electronic monitoring of chemical DNA denaturation on nanocrystalline diamond electrodes with different molarities and flow rates}, series = {Physica Status Solidi (A). Vol. 210 (2013), iss. 5}, journal = {Physica Status Solidi (A). Vol. 210 (2013), iss. 5}, publisher = {Wiley-VCH}, address = {Berlin}, issn = {0031-8965}, pages = {911 -- 917}, year = {2013}, language = {en} } @article{AridaTurekRolkaetal.2009, author = {Arida, Hassan and Turek, Monika and Rolka, David and Sch{\"o}ning, Michael Josef}, title = {A Novel Thin-Film Copper Array Based on an Organic/Inorganic Sensor Hybrid: Microfabrication, Potentiometric Characterization, and Flow-Injection Analysis Application}, series = {Electroanalysis. 21 (2009), H. 10}, journal = {Electroanalysis. 21 (2009), H. 10}, publisher = {Wiley}, address = {Weinheim}, isbn = {1040-0397}, pages = {1145 -- 1151}, year = {2009}, language = {en} } @article{MorenoiCodinachsBirkenstockGarmaetal.2009, author = {Moreno i Codinachs, L. and Birkenstock, C. and Garma, T. and Zierold, R. and Bachmann, J. and Nielsch, K. and Sch{\"o}ning, Michael Josef and Fontcuberta i Morral, A.}, title = {A micron-sized nanoporous multifunction sensing device}, series = {physica status solidi (a) . 206 (2009), H. 3}, journal = {physica status solidi (a) . 206 (2009), H. 3}, publisher = {Wiley}, address = {Weinheim}, isbn = {1862-6319}, pages = {435 -- 441}, year = {2009}, language = {en} } @article{NaetherHenkelSchneideretal.2009, author = {N{\"a}ther, Niko and Henkel, Hartmut and Schneider, Andreas and Sch{\"o}ning, Michael Josef}, title = {Investigation of different catalytically active and passive materials for realising a hydrogen peroxide gas sensor}, series = {physica status solidi (a) . 206 (2009), H. 3}, journal = {physica status solidi (a) . 206 (2009), H. 3}, publisher = {Wiley}, address = {Weinheim}, isbn = {1862-6319}, pages = {449 -- 454}, year = {2009}, language = {en} } @article{SiqueiraAbouzarBaeckeretal.2009, author = {Siqueira, Jos{\´e} R. Jr. and Abouzar, Maryam H. and B{\"a}cker, Matthias and Zucolotto, Valtencir and Poghossian, Arshak and Oliveira, Osvaldo N. Jr. and Sch{\"o}ning, Michael Josef}, title = {Carbon nanotubes in nanostructured films: Potential application as amperometric and potentiometric field-effect (bio-)chemical sensors}, series = {physica status solidi (a) . 206 (2009), H. 3}, journal = {physica status solidi (a) . 206 (2009), H. 3}, publisher = {Wiley}, address = {Weinheim}, isbn = {1862-6319}, pages = {462 -- 467}, year = {2009}, language = {en} } @article{LanzlSeidovaMaieretal.2011, author = {Lanzl, Ines M. and Seidova, Seid-Fatima and Maier, Mathias and Schmidt-Trucks{\"a}ss, Arno and Halle, Martin and Kotliar, Konstantin}, title = {Dynamic retinal vessel response to flicker in age-related macular degeneration patients before and after vascular endothelial growth factor inhibitor injection}, series = {Acta Ophthalmologica}, volume = {89}, journal = {Acta Ophthalmologica}, number = {5}, publisher = {Wiley}, address = {Weinheim}, isbn = {1755-3768}, pages = {472 -- 479}, year = {2011}, language = {en} } @article{MukherjeeRamazaniYangetal.2011, author = {Mukherjee, Krishnendu and Ramazani, Ali and Yang, Li and Prahl, Ulrich and Bleck, Wolfgang and Reisgen, Uwe and Schleser, Markus and Abdurakhmanov, Aydemir}, title = {Characterization of gas metal arc welded hot rolled DP600 steel}, series = {Steel research international}, volume = {Vol. 82}, journal = {Steel research international}, number = {Iss. 12}, publisher = {Wiley}, address = {Weinheim}, issn = {1869-344X (E-Book); 1611-3683 (Print)}, pages = {1408 -- 1416}, year = {2011}, language = {en} } @article{BongaertsEsserLorbachetal.2011, author = {Bongaerts, Johannes and Esser, Simon and Lorbach, Volker and Al-Momani, L{\´o}ay and M{\"u}ller, Michael A. and Franke, Dirk and Grondal, Christoph and Kurutsch, Anja and Bujnicki, Robert and Takors, Ralf and Raeven, Leon and Wubbolts, Marcel and Bovenberg, Roel and Nieger, Martin and Sch{\"u}rmann, Melanie and Trachtmann, Natalie and Kozak, Stefan and Sprenger, Georg A. and M{\"u}ller, Michael}, title = {Diversity-oriented production of metabolites derived from chorismate and their use in organic synthesis}, series = {Angewandte Chemie International Edition}, volume = {Vol. 50}, journal = {Angewandte Chemie International Edition}, number = {Iss. 34}, publisher = {Wiley}, address = {Weinheim}, issn = {1521-3773 (E-Journal); 0570-0833 (Print); 1433-7851 (Print)}, pages = {7781 -- 7786}, year = {2011}, language = {en} } @article{VoigtSchroeterJuergenetal.2013, author = {Voigt, Birgit and Schroeter, Rebecca and J{\"u}rgen, Britta and Albrecht, Dirk and Evers, Stefan and Bongaerts, Johannes and Maurer, Karl-Heinz and Schweder, Thomas and Hecker, Michael}, title = {The response of Bacillus licheniformis to heat and ethanol stress and the role of the SigB regulon}, series = {Proteomics}, volume = {Vol. 13}, journal = {Proteomics}, number = {Iss. 14}, publisher = {Wiley}, address = {Weinheim}, issn = {1615-9861 (E-Journal); 1615-9853 (Print)}, pages = {2140 -- 2146}, year = {2013}, language = {en} } @article{HeggerClassenSchaumannetal.2013, author = {Hegger, Josef and Claßen, Martin and Schaumann, Peter and Sothmann, J{\"o}rg and Feldmann, Markus and D{\"o}ring, Bernd}, title = {Entwicklung einer integrierten Verbunddecke f{\"u}r nachhaltige Stahlbauten}, series = {Stahlbau}, volume = {Vol. 82}, journal = {Stahlbau}, number = {Iss. 1}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1049 (E-Journal); 0038-9145 (Print)}, pages = {11 -- 17}, year = {2013}, language = {de} } @article{HeggerClassenFeldmannetal.2011, author = {Hegger, Josef and Claßen, Martin and Feldmann, Markus and D{\"o}ring, Bernd and Schaumann, Peter and Sothmann, J{\"o}rg and Bohne, Dirk and Hargus, Steen and Barben, Daniel and Aarden, Erik and Schielke, Sabine}, title = {Integrierte und nachhaltigkeitsorientierte Deckensysteme im Stahl- und Verbundbau}, series = {Stahlbau}, volume = {Vol. 80}, journal = {Stahlbau}, number = {Iss. 10}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1049 (E-Journal); 0038-9145 (Print)}, pages = {728 -- 733}, year = {2011}, language = {de} } @article{DoeringFeldmannKuhnhenneetal.2011, author = {D{\"o}ring, Bernd and Feldmann, Markus and Kuhnhenne, Markus and M{\"u}ller, Dirk}, title = {Phasenwechselmaterial im Metallleichtbau zur Optimierung von Energieeffizienz und sommerlicher Raumtemperatur}, series = {Stahlbau}, volume = {Vol. 80}, journal = {Stahlbau}, number = {Iss. 9}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1049 (E-Journal); 0038-9145 (Print)}, pages = {666 -- 672}, year = {2011}, language = {de} } @article{DoeringFeldmannKuhnhenne2009, author = {D{\"o}ring, Bernd and Feldmann, Markus and Kuhnhenne, Markus}, title = {Der Beitrag von Profilblechdecken zur passiven K{\"u}hlung}, series = {Bauphysik}, volume = {Vol. 31}, journal = {Bauphysik}, number = {Iss. 2}, publisher = {Wiley}, address = {Weinheim}, isbn = {1437-0980 (E-Journal); 0171-5445 (Print)}, pages = {65 -- 71}, year = {2009}, language = {de} } @article{JiminezGermanBehbahaniMiettinenetal.2013, author = {Jiminez German, Salvador and Behbahani, Mehdi and Miettinen, Susanna and Grijpma, Dirk W. and Haimi, Suvi P.}, title = {Proliferation and differentiation of adipose stem cells towards smooth muscle cells on poly(trimethylene carbonate) membranes}, series = {Macromolecular symposia}, volume = {Vol. 334}, journal = {Macromolecular symposia}, number = {Iss. 1}, publisher = {Wiley}, address = {Weinheim}, issn = {0258-0322}, pages = {133 -- 142}, year = {2013}, language = {en} } @article{HeinzeMangPeteretal.2014, author = {Heinze, Daniel and Mang, Thomas and Peter, Karin and M{\"o}ller, Martin and Weichold, Oliver}, title = {Synthesis of low molecular weight poly(vinyl acetate) and its application as plasticizer}, series = {Journal of applied polymer science}, volume = {131}, journal = {Journal of applied polymer science}, number = {9}, publisher = {Wiley}, address = {New York}, issn = {1097-4628 (E-Journal); 0021-8995 (Print)}, doi = {10.1002/app.40226}, pages = {Article No. 40226}, year = {2014}, abstract = {Poly(vinyl acetate), PVAc, with a degree of polymerization Xn = 10 was prepared by chain-transfer radical polymerization using carbon tetrachloride and used as oligomeric plasticizer for commercial PVAc. However, the chlorinated chain ends cause a low thermal stability requiring mild Cl/H substitution. The product exhibits high thermal stability and excellent melt-compounding properties. Blends of oligomeric and commercial PVAc show single glass transition temperatures which decrease with higher oligomer content and exhibit small negative deviations from Fox' linear additivity rule. This indicates plasticization and miscibility being mainly due to entropic effects. Injection-moulded thick specimens show ductile behaviour at oligomer contents >10 wt \%, while sheets with a thickness of 0.2-0.5 mm appear flexible already at 7.5 wt \%. The oxygen permeability coefficients are an order of magnitude lower than those of low-density polyethylene. Due to the sum of their properties, the plasticized sheets present a promising alternative in the preparation of barrier materials.}, language = {en} } @article{WangDruckenmuellerElbersetal.2014, author = {Wang, Ren-Qi and Druckenm{\"u}ller, Katharina and Elbers, Gereon and Guenther, Klaus and Crou{\´e}, Jean-Philippe}, title = {Analysis of aquatic-phase natural organic matter by optimized LDI-MS method}, series = {Journal of mass spectrometry}, volume = {49}, journal = {Journal of mass spectrometry}, number = {2}, publisher = {Wiley}, address = {Bognor Regis}, issn = {1096-9888}, doi = {10.1002/jms.3321}, pages = {154 -- 160}, year = {2014}, abstract = {The composition and physiochemical properties of aquatic-phase natural organic matter (NOM) are most important problems for both environmental studies and water industry. Laser desorption/ionization (LDI) mass spectrometry facilitated successful examinations of NOM, as humic and fulvic acids in NOM are readily ionized by the nitrogen laser. In this study, hydrophobic NOMs (HPO NOMs) from river, reservoir and waste water were characterized by this technique. The effect of analytical variables like concentration, solvent composition and laser energy was investigated. The exact masses of small molecular NOM moieties in the range of 200-1200 m/z were determined in reflectron mode. In addition, spectra of post-source-decay experiments in this range showed that some compounds from different natural NOMs had the same fragmental ions. In the large mass range of 1200-15 000 Da, macromolecules and their aggregates were found in HPO NOMs from natural waters. Highly humic HPO exhibited mass peaks larger than 8000 Da. On the other hand, the waste water and reservoir water mainly had relatively smaller molecules of about 2000 Da. The LDI-MS measurements indicated that highly humic river waters were able to form large aggregates and membrane foulants, while the HPO NOMs from waste water and reservoir water were unlikely to form large aggregates. Copyright © 2014 John Wiley \& Sons, Ltd.}, language = {en} } @article{MartinezJakobTuetal.2013, author = {Martinez, Ronny and Jakob, Felix and Tu, Ran and Siegert, Petra and Maurer, Karl-Heinz and Schwaneberg, Ulrich}, title = {Increasing activity and thermal resistance of Bacillus gibsonii alkaline protease (BgAP) by directed evolution}, series = {Biotechnology and bioengineering}, volume = {Vol. 110}, journal = {Biotechnology and bioengineering}, number = {Iss. 3}, publisher = {Wiley}, address = {Weinheim}, issn = {1097-0290 (E-Journal); 0006-3592 (Print); 0368-1467 (Print)}, pages = {711 -- 720}, year = {2013}, language = {en} } @article{RibitschHeumannTrotschaetal.2011, author = {Ribitsch, D. and Heumann, S. and Trotscha, E. and Herrero Acero, E. and Greimel, K. and Leber, R. and Birger-Gruenberger, R. and Deller, S. and Eiteljoerg, I. and Remler, P. and Weber, Th. and Siegert, Petra and Maurer, Karl-Heinz and Donelli, I. and Freddi, G. and Schwab, H. and Guebitz, G. M.}, title = {Hydrolysis of polyethyleneterephthalate by p-nitrobenzylesterase from Bacillus subtilis}, series = {Biotechnology progress}, volume = {Vol. 27}, journal = {Biotechnology progress}, number = {Iss. 4}, publisher = {Wiley}, address = {Hoboken}, issn = {1520-6033 (E-Journal); 8756-7938 (Print)}, pages = {951 -- 960}, year = {2011}, language = {en} } @article{OberlaenderBrommWendeleretal.2015, author = {Oberl{\"a}nder, Jan and Bromm, Alexander and Wendeler, Luisa and Iken, Heiko and Palomar Duran, Marlena and Greeff, Anton and Kirchner, Patrick and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Towards a biosensor to monitor the sterilisation efficiency of aseptic filling machines}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431900}, pages = {1299 -- 1305}, year = {2015}, abstract = {Sterilisation processes are compulsory in medicine, pharmacy, and food industries to prevent infections of consumers and microbiological contaminations of products. Monitoring the sterilisation by conventional microbiological methods is time- and lab-consuming. To overcome this problem, in this work a novel biosensor has been proposed. The sensor enables a fast method to evaluate sterilisation processes. By means of thin-film technology the sensor's transducer structures in form of IDEs (interdigitated electrodes) have been fabricated on a silicon substrate. Physical characterisation of the developed sensor was done by AFM, SEM, and profilometry. Impedance analyses were conducted for the electrical characterisation. As microbiological layer spores of B. atrophaeus have been immobilised on the sensing structure; spores of this type are a well-known sterilisation test organism. Impedance measurements at a fixed frequency over time were performed to monitor the immobilisation process. A sterilisation process according to aseptic filling machines was applied to demonstrate the sensor functionality. After both, immobilisation and sterilisation, a change in impedance could successfully be detected.}, language = {en} } @article{HuckPoghossianBaeckeretal.2015, author = {Huck, Christina and Poghossian, Arshak and B{\"a}cker, Matthias and Reisert, Steffen and Kramer, Friederike and Begoyan, Vardges K. and Buniatyan, Vahe V. and Sch{\"o}ning, Michael Josef}, title = {Multi-parameter sensing using high-k oxide of barium strontium titanate}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431911}, pages = {1259}, year = {2015}, abstract = {High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors. In this work, a Si-based sensor chip containing Pt interdigitated electrodes covered with a thin BST layer (485 nm) has been developed for multi-parameter chemical sensing. The chip has been applied for the contactless measurement of the electrolyte conductivity, the detection of adsorbed charged macromolecules (positively charged polyelectrolytes of polyethylenimine) and the concentration of hydrogen peroxide (H2O2) vapor. The experimental results of functional testing of individual sensors are presented. The mechanism of the BST sensitivity to charged polyelectrolytes and H2O2 vapor has been proposed and discussed.}, language = {en} } @article{JildehWagnerSchoeningetal.2015, author = {Jildeh, Zaid B. and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Pieper, Martin}, title = {Simulating the electromagnetic-thermal treatment of thin aluminium layers for adhesion improvement}, series = {Physica status solidi (a)}, volume = {Vol. 212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431893}, pages = {1234 -- 1241}, year = {2015}, abstract = {A composite layer material used in packaging industry is made from joining layers of different materials using an adhesive. An important processing step in the production of aluminium-containing composites is the surface treatment and consequent coating of adhesive material on the aluminium surface. To increase adhesion strength between aluminium layer and the adhesive material, the foil is heat treated. For efficient heating, induction heating was considered as state-of-the-art treatment process. Due to the complexity of the heating process and the unpredictable nature of the heating source, the control of the process is not yet optimised. In this work, a finite element analysis of the process was established and various process parameters were studied. The process was simplified and modelled in 3D. The numerical model contains an air domain, an aluminium layer and a copper coil fitted with a magnetic field concentrating material. The effect of changing the speed of the aluminium foil (or rolling speed) was studied with the change of the coil current. Statistical analysis was used for generating a general control equation of coil current with changing rolling speed.}, language = {en} } @article{PilasIkenSelmeretal.2015, author = {Pilas, Johanna and Iken, Heiko and Selmer, Thorsten and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Development of a multi-parameter sensor chip for the simultaneous detection of organic compounds in biogas processes}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431894}, pages = {1306 -- 1312}, year = {2015}, abstract = {An enzyme-based multi-parameter biosensor is developed for monitoring the concentration of formate, d-lactate, and l-lactate in biological samples. The sensor is based on the specific dehydrogenation by an oxidized β-nicotinamide adenine dinucleotide (NAD+)-dependent dehydrogenase (formate dehydrogenase, d-lactic dehydrogenase, and l-lactic dehydrogenase, respectively) in combination with a diaphorase from Clostridium kluyveri (EC 1.8.1.4). The enzymes are immobilized on a platinum working electrode by cross-linking with glutaraldehyde (GA). The principle of the determination scheme in case of l-lactate is as follows: l-lactic dehydrogenase (l-LDH) converts l-lactate into pyruvate by reaction with NAD+. In the presence of hexacyanoferrate(III), the resulting reduced β-nicotinamide adenine dinucleotide (NADH) is then regenerated enzymatically by diaphorase. The electrochemical detection is based on the current generated by oxidation of hexacyanoferrate(II) at an applied potential of +0.3 V vs. an Ag/AgCl reference electrode. The biosensor will be electrochemically characterized in terms of linear working range and sensitivity. Additionally, the successful practical application of the sensor is demonstrated in an extract from maize silage.}, language = {en} } @article{BreuerRaueKirschbaumetal.2015, author = {Breuer, Lars and Raue, Markus and Kirschbaum, M. and Mang, Thomas and Sch{\"o}ning, Michael Josef and Thoelen, R. and Wagner, Torsten}, title = {Light-controllable polymeric material based on temperature-sensitive hydrogels with incorporated graphene oxide}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431944}, pages = {1368 -- 1374}, year = {2015}, abstract = {Poly(N-isopropylacrylamide) (PNIPAAm) hydrogel films with incorporated graphene oxide (GO) were developed and tested as light-stimulated actuators. GO dispersions were synthesized via Hummers method and characterized toward their optical properties and photothermal energy conversion. The hydrogels were prepared by means of photopolymerization. In addition, the influence of GO within the hydrogel network on the lower critical solution temperature (LCST) was investigated by differential scanning calorimetry (DSC). The optical absorbance and the response to illumination were determined as a function of GO concentration for thin hydrogel films. A proof of principle for the stimulation with light was performed.}, language = {en} } @article{BegingLeinhosJablonskietal.2015, author = {Beging, Stefan and Leinhos, Marcel and Jablonski, Melanie and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Studying the spatially resolved immobilisation of enzymes on a capacitive field-effect structure by means of nano-spotting}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431891}, pages = {1353 -- 1358}, year = {2015}, language = {en} } @article{SchiffelsSelmer2015, author = {Schiffels, Johannes and Selmer, Thorsten}, title = {A flexible toolbox to study protein-assisted metalloenzyme assembly in vitro}, series = {Biotechnology and Bioengineering}, volume = {112}, journal = {Biotechnology and Bioengineering}, number = {11}, publisher = {Wiley}, address = {Weinheim}, issn = {1097-0290}, doi = {10.1002/bit.25658}, pages = {2360 -- 2372}, year = {2015}, language = {en} } @article{VoigtAlbrechtSieversetal.2015, author = {Voigt, Birgit and Albrecht, Dirk and Sievers, Susanne and Becher, D{\"o}rte and Bongaerts, Johannes and Evers, Stefan and Schweder, Thomas and Maurer, Karl-Heinz and Hecker, Michael}, title = {High-resolution proteome maps of Bacillus licheniformis cells growing in minimal medium}, series = {Proteomics}, volume = {15}, journal = {Proteomics}, number = {15}, publisher = {Wiley}, address = {Weinheim}, issn = {1615-9861}, doi = {10.1002/pmic.201400504}, pages = {2629 -- 2633}, year = {2015}, language = {en} } @article{KuertenMottaghyZiegler2015, author = {K{\"u}rten, Sylvia and Mottaghy, Darius and Ziegler, Martin}, title = {Besonderheiten bei der Planung und Berechnung von oberfl{\"a}chennahen thermo-aktiven Bauteilen}, series = {Geotechnik}, volume = {38}, journal = {Geotechnik}, number = {2}, publisher = {Wiley}, address = {Weinheim}, issn = {2190-6653}, doi = {10.1002/gete.201500002}, pages = {107 -- 119}, year = {2015}, language = {de} } @article{LaumannMainz2012, author = {Laumann, J{\"o}rg and Mainz, Stefan}, title = {Direkte Ermittlung der erforderlichen Einspanntiefe von I‑f{\"o}rmigen Stahlquerschnitten in Betonkonstruktionen}, volume = {81}, number = {11}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1049}, doi = {10.1002/stab.201201620}, pages = {850 -- 860}, year = {2012}, abstract = {F{\"u}r die Ermittlung der erforderlichen Einspanntiefe von eingespannten Stahlquerschnitten in Betonkonstruktionen existieren verschiedene Bemessungsmodelle. Diese basieren vorwiegend auf Grundlage nationaler Normen wie z. B. DIN 18800 [1] und DIN 1045 [2], die durch die europ{\"a}ische Normung ersetzt wurden. Aus diesem Grund wird in diesem Aufsatz ein Berechnungsmodell f{\"u}r die erforderliche Einspanntiefe von eingespannten Stahlquerschnitten in Betonkonstruktionen auf Grundlage des Eurocodes vorgestellt. Das Grundger{\"u}st f{\"u}r dieses Berechnungsmodell bildet das Verfahren nach Kindmann und Laumann, welches in [3] behandelt wurde. Gleichzeitig werden neue Formeln zur direkten Ermittlung der Mindesteinspanntiefe vorgestellt. Behandelt werden gewalzte I-Profile f{\"u}r einachsige Biegung um die starke Achse (y-y) mit Drucknormalkraft.}, language = {de} } @article{BaeckerSchusserPoghossianetal.2014, author = {B{\"a}cker, Matthias and Schusser, Sebastian and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Multi-Parametererfassung mit siliziumbasiertem Sensorchip: Aus Drei mach Eins}, series = {GIT Labor-Fachzeitschrift}, journal = {GIT Labor-Fachzeitschrift}, number = {2}, publisher = {Wiley}, issn = {0016-3538}, pages = {28 -- 30}, year = {2014}, language = {de} } @article{KotliarKharoubiSchmidtTrucksaessetal.2009, author = {Kotliar, Konstantin and Kharoubi, A. and Schmidt-Trucks{\"a}ß, A. and Halle, M. and Lanzl, I.}, title = {Does internal longitudinal microstructure of retinal veins change with age in medically healthy persons?}, series = {Acta Ophthalmologica}, volume = {Vol. 87}, journal = {Acta Ophthalmologica}, number = {Suppl. S244}, publisher = {Wiley}, address = {Weinheim}, issn = {1600-0420 (E-Journal); 1755-3768 (E-Journal); 0001-639X (Print); 1395-3907 (Print); 1755-375X (Print)}, pages = {0}, year = {2009}, language = {en} } @article{DelleHuckBaeckeretal.2015, author = {Delle, Lotta E. and Huck, Christina and B{\"a}cker, Matthias and M{\"u}ller, Frank and Grandthyll, Samuel and Jacobs, Karin and Lilischkis, Rainer and Vu, Xuan T. and Sch{\"o}ning, Michael Josef and Wagner, Patrick and Thoelen, Roland and Weil, Maryam and Ingebrandt, Sven}, title = {Impedimetric immunosensor for the detection of histamine based on reduced graphene oxide}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431863}, pages = {1327 -- 1334}, year = {2015}, language = {en} } @article{TakenagaSchneiderErbayetal.2015, author = {Takenaga, Shoko and Schneider, Benno and Erbay, E. and Biselli, Manfred and Schnitzler, Thomas and Sch{\"o}ning, Michael Josef and Wagner, Torsten}, title = {Fabrication of biocompatible lab-on-chip devices for biomedical applications by means of a 3D-printing process}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201532053}, pages = {1347 -- 1352}, year = {2015}, abstract = {A new microfluidic assembly method for semiconductor-based biosensors using 3D-printing technologies was proposed for a rapid and cost-efficient design of new sensor systems. The microfluidic unit is designed and printed by a 3D-printer in just a few hours and assembled on a light-addressable potentiometric sensor (LAPS) chip using a photo resin. The cell growth curves obtained from culturing cells within microfluidics-based LAPS systems were compared with cell growth curves in cell culture flasks to examine biocompatibility of the 3D-printed chips. Furthermore, an optimal cell culturing within microfluidics-based LAPS chips was achieved by adjusting the fetal calf serum concentrations of the cell culture medium, an important factor for the cell proliferation.}, language = {en} } @article{MolinnusBaeckerIkenetal.2015, author = {Molinnus, Denise and B{\"a}cker, Matthias and Iken, Heiko and Poghossian, Arshak and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Concept for a biomolecular logic chip with an integrated sensor and actuator function}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431913}, pages = {1382 -- 1388}, year = {2015}, abstract = {A concept for a new generation of an integrated multi-functional biosensor/actuator system is developed, which is based on biomolecular logic principles. Such a system is expected to be able to detect multiple biochemical input signals simultaneously and in real-time and convert them into electrical output signals with logical operations such as OR, AND, etc. The system can be designed as a closed-loop drug release device triggered by an enzyme logic gate, while the release of the drug induced by the actuator at the required dosage and timing will be controlled by an additional drug sensor. Thus, the system could help to make an accurate and specific diagnosis. The presented concept is exemplarily demonstrated by using an enzyme logic gate based on a glucose/glucose oxidase system, a temperature-responsive hydrogel mimicking the actuator function and an insulin (drug) sensor. In this work, the results of functional testing of individual amperometric glucose and insulin sensors as well as an impedimetric sensor for the detection of the hydrogel swelling/shrinking are presented.}, language = {en} } @article{ButenwegFehling2012, author = {Butenweg, Christoph and Fehling, Ekkehard}, title = {Hintergrund f{\"u}r die vereinfachten Regeln bei Mauerwerksgeb{\"a}uden im Erdbebenfall}, series = {Mauerwerk : European journal of masonry}, volume = {Volume 16}, journal = {Mauerwerk : European journal of masonry}, number = {Issue 3}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1022 (E-Journal); 1432-3427 (Print)}, doi = {10.1002/dama.201200537}, pages = {127 -- 137}, year = {2012}, abstract = {Bei der Ausarbeitung des nationalen Anwendungsdokumentes zur DIN EN 1998-1 waren die in der ENV-Fassung enthaltenen vereinfachten Regeln im Lichte aktueller Forschungsergebnisse zu {\"u}berpr{\"u}fen und zu {\"u}berarbeiten. Die gleiche Aufgabe stellte sich auch f{\"u}r die Neufassung der DIN 4149. In beiden F{\"a}llen sind neben konstruktiven Regeln f{\"u}r die Art und Anordnung der zur Geb{\"a}udeaussteifung heranzuziehenden W{\"a}nde im Grundriss Tabellen enthalten, die unter bestimmten Bedingungen den Entfall eines rechnerischen Nachweises der Tragw{\"a}nde im Erdbebenfall erm{\"o}glichen. Dies ist f{\"u}r Schwachbebengebiete, wie sie in Deutschland und anderen L{\"a}ndern Mitteleuropas anzutreffen sind, sinnvoll, um unn{\"o}tigen Rechenaufwand sowie Probleme mit der F{\"u}hrbarkeit von Nachweisen so weit wie m{\"o}glich auszuschalten. Im vorliegenden Beitrag werden die Hintergr{\"u}nde der vereinfachten Regeln diskutiert und die Ergebnisse der Anwendung mit verschiedenen Rechenverfahren verglichen und bewertet.}, language = {de} } @article{ButenwegGellert2012, author = {Butenweg, Christoph and Gellert, Christoph}, title = {Integrale Geb{\"a}udeplanung am Beispiel eines Geschossbaus in Ziegelmauerwerk}, series = {Mauerwerk : European journal of masonry}, volume = {Volume 16}, journal = {Mauerwerk : European journal of masonry}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1022 (E-Journal); 1432-3427 (Print)}, doi = {10.1002/dama.201200550}, pages = {247 -- 254}, year = {2012}, abstract = {Moderne Mauerwerksbauten m{\"u}ssen nach heutigen Anforderungen architektonisch, statisch, energetisch sowie schall- und brandschutztechnisch optimal ausgelegt sein. Aufgrund der Komplexit{\"a}t und engen Verzahnung der einzelnen Anforderungen ist eine integrale Geb{\"a}udeplanung zur Erzielung einer qualitativ hochwertigen Bauwerksl{\"o}sung unbedingt notwendig. Diese erfordert von den Fachplanern vertieftes Spezialwissen in den verschiedenen Bereichen, um insbesondere die Schnittstellen und Bauwerksdetails korrekt zu planen und auszuf{\"u}hren. Der Beitrag stellt die integrale Geb{\"a}udeplanung am Beispiel eines Geschossbaus in Ziegelbauweise mit L{\"o}sungen f{\"u}r wesentliche Detailpunkte vor}, language = {de} } @article{ButenwegGellert2013, author = {Butenweg, Christoph and Gellert, Christoph}, title = {Nichtlinearer Nachweis von Mauerwerksbauten}, series = {Mauerwerk : European journal of masonry}, volume = {Volume 17}, journal = {Mauerwerk : European journal of masonry}, number = {Issue 3}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1022 (E-Journal); 1432-3427 (Print)}, doi = {10.1002/dama.201300575}, pages = {166 -- 171}, year = {2013}, language = {de} } @article{TaddeiButenwegKlinkel2015, author = {Taddei, Francesca and Butenweg, Christoph and Klinkel, S.}, title = {Parametric investigation of the soil-structure interaction effects on the dynamic behaviour of a shallow foundation supported wind turbine considering a layered soil}, series = {Wind energy : an international journal for progress and applications in wind power conversion technology}, volume = {Volume 18}, journal = {Wind energy : an international journal for progress and applications in wind power conversion technology}, number = {Issue 3}, publisher = {Wiley}, address = {Weinheim}, issn = {1099-1824 (E-Journal); 1095-4244 (Print)}, doi = {10.1002/we.1703}, pages = {399 -- 417}, year = {2015}, language = {en} } @article{KubalskiButenweg2015, author = {Kubalski, Thomas and Butenweg, Christoph}, title = {Modelling strategies for horizontally loaded infill masonry}, series = {Mauerwerk : European journal of masonry}, volume = {Volume 19}, journal = {Mauerwerk : European journal of masonry}, number = {Issue 5}, publisher = {Wiley}, address = {Weinheim}, doi = {10.1002/dama.201500675}, pages = {363 -- 369}, year = {2015}, language = {de} }