@article{TippkoetterWollnySucketal.2014, author = {Tippk{\"o}tter, Nils and Wollny, Steffen and Suck, Kirstin and Sohling, Ulrich and Ruf, Friedrich and Ulber, Roland}, title = {Recycling of spent oil bleaching earth as source of glycerol for the anaerobic production of acetone, butanol, and ethanol with Clostridium diolis and lipolytic Clostridium lundense}, series = {Engineering in Life Sciences}, volume = {14}, journal = {Engineering in Life Sciences}, number = {4}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1618-2863}, doi = {10.1002/elsc.201300113}, pages = {425 -- 432}, year = {2014}, abstract = {A major part of edible oil is subjected to bleaching procedures, primarily with minerals applied as adsorbers. Their recycling is currently done either by regaining the oil via organic solvent extraction or by using the spent bleaching earth (SBE) as additive for animal feed, etc. As a new method, the reutilization of the by-product SBE for the microbiologic formation of acetone, butanol, and ethanol (ABE) is presented as proof-of-concept. The SBE was taken from a palm oil cleaning process. The recycling concept is based on the application of lipolytic clostridia strains. Due to considerably long fermentation times, co-fermentation with Candida rugosa and enzymatic hydrolyses of the bound oil with a subsequent clostridia fermentation are shown as alternative routes. Anaerobic fermentations under comparison of different clostridia strains were performed with glycerol media, enzymatically hydrolyzed palm oil and SBE. Solutes, side product compositions and productivities were quantified via HPLC. A successful production of ABE solutes from SBE has been done with a yield of 0.15 g butanol per gram of bound glycerol. Thus, the biotechnological recycling of the waste stream is possible in principle. Inhibition of the substrate suspension has been observed. A chromatographic ion-exchange of substrates increased the biomass concentration.}, language = {en} } @article{ThielMufflerTippkoetteretal.2015, author = {Thiel, Alexander and Muffler, Kai and Tippk{\"o}tter, Nils and Suck, Kirstin and Sohling, Ulrich and Ruf, Friedrich and Ulber, Roland}, title = {Aufarbeitung von Polyphenolen aus Weizen mittels Zeolithen am Beispiel der Ferulas{\"a}ure}, series = {Chemie IngenieurTechnik}, volume = {87}, journal = {Chemie IngenieurTechnik}, number = {1-2}, publisher = {Wiley}, address = {Weinheim}, doi = {10.1002/cite.201400031}, pages = {128 -- 136}, year = {2015}, abstract = {Aufarbeitung von Polyphenolen aus Weizenmittels Zeolithen am Beispiel der Ferulasa¨ ureAlexander Thiel1, Kai Muffler1, Nils Tippko¨ tter1, Kirstin Suck2, Ulrich Sohling2, Friedrich Ruf3und Roland Ulber1,*DOI: 10.1002/cite.201400031Bei der Ferulasa¨ure handelt es sich um einen Wertstoff, der aus Weizen gewonnen und in der Lebensmittel- und Pharma-industrie eingesetzt werden kann. Der Einsatz von Weizen als nachwachsende Rohstoffquelle ist allerdings nur dann wirt-schaftlich durchfu¨hrbar, wenn eine Prozessintegration in die bestehenden industriellen Verfahren gewa¨hrleistet oder einedirekte Konkurrenz zur Mehl- und Sta¨rkeindustrie vermieden werden kann. In diesem Artikel wird ein Verfahren aufge-zeigt, welches hohe Ausbeuten ermo¨glicht und eine Konkurrenz zu bestehenden Verwertungspfaden vermeidet.}, language = {de} } @article{AlKaidyDuweHusteretal.2015, author = {Al-Kaidy, Huschyar and Duwe, Anna and Huster, Manuel and Muffler, Kai and Schlegel, Christin and Tim, Sieker and Stadtm{\"u}ller, Ralf and Tippk{\"o}tter, Nils and Ulber, Roland}, title = {Biotechnology and bioprocess engineering - from the first ullmann's article to recent trends}, series = {ChemBioEng Reviews}, volume = {2}, journal = {ChemBioEng Reviews}, number = {3}, publisher = {Wiley}, address = {Weinheim}, doi = {10.1002/cben.201500008}, pages = {175 -- 184}, year = {2015}, abstract = {For several thousand years, biotechnology and its associated technical processes have had a great impact on the development of mankind. Based on empirical methods, in particular for the production of foodstuffs and daily commodities, these disciplines have become one of the most innovative future issues. Due to the increasing detailed understanding of cellular processes, production strains can now be optimized. In combination with modern bioprocesses, a variety of bulk and fine chemicals as well as pharmaceuticals can be produced efficiently. In this article, some of the current trends in biotechnology are discussed.}, language = {en} } @article{SchusserLeinhosBaeckeretal.2013, author = {Schusser, Sebastian and Leinhos, Marcel and B{\"a}cker, Matthias and Poghossian, Arshak and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Impedance spectroscopy: A tool for real-time in situ monitoring of the degradation of biopolymers}, series = {Physica Status Solidi (A)}, volume = {210}, journal = {Physica Status Solidi (A)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1521-396X ; 0031-8965}, doi = {10.1002/pssa.201200941}, pages = {905 -- 910}, year = {2013}, abstract = {Investigation of the degradation kinetics of biodegradable polymers is essential for the development of implantable biomedical devices with predicted biodegradability. In this work, an impedimetric sensor has been applied for real-time and in situ monitoring of degradation processes of biopolymers. The sensor consists of two platinum thin-film electrodes covered by a polymer film to be studied. The benchmark biomedical polymer poly(D,L-lactic acid) (PDLLA) was used as a model system. PDLLA films were deposited on the sensor structure from a polymer solution by using the spin-coating method. The degradation kinetics of PDLLA films have been studied in alkaline solutions of pH 9 and 12 by means of an impedance spectroscopy (IS) method. Any changes in a polymer capacitance/resistance induced by water uptake and/or polymer degradation will modulate the global impedance of the polymer-covered sensor that can be used as an indicator of the polymer degradation. The degradation rate can be evaluated from the time-dependent impedance spectra. As expected, a faster degradation has been observed for PDLLA films exposed to pH 12 solution.}, language = {en} } @article{DrummEmhardtKoketal.2020, author = {Drumm, Christian and Emhardt, Selina N. and Kok, Ellen M. and Jarodzka, Halzka and Brand-Gruwel, Saskia and van Gog, Tamara}, title = {How Experts Adapt Their Gaze Behavior When Modeling a Task to Novices}, series = {Cognitive science}, volume = {44}, journal = {Cognitive science}, number = {9}, publisher = {Wiley}, address = {Weinheim}, issn = {1551-6709}, doi = {10.1111/cogs.12893}, pages = {26}, year = {2020}, abstract = {Domain experts regularly teach novice students how to perform a task. This often requires them to adjust their behavior to the less knowledgeable audience and, hence, to behave in a more didactic manner. Eye movement modeling examples (EMMEs) are a contemporary educational tool for displaying experts' (natural or didactic) problem-solving behavior as well as their eye movements to learners. While research on expert-novice communication mainly focused on experts' changes in explicit, verbal communication behavior, it is as yet unclear whether and how exactly experts adjust their nonverbal behavior. This study first investigated whether and how experts change their eye movements and mouse clicks (that are displayed in EMMEs) when they perform a task naturally versus teach a task didactically. Programming experts and novices initially debugged short computer codes in a natural manner. We first characterized experts' natural problem-solving behavior by contrasting it with that of novices. Then, we explored the changes in experts' behavior when being subsequently instructed to model their task solution didactically. Experts became more similar to novices on measures associated with experts' automatized processes (i.e., shorter fixation durations, fewer transitions between code and output per click on the run button when behaving didactically). This adaptation might make it easier for novices to follow or imitate the expert behavior. In contrast, experts became less similar to novices for measures associated with more strategic behavior (i.e., code reading linearity, clicks on run button) when behaving didactically.}, language = {en} } @article{BaeckerSchusserPoghossianetal.2014, author = {B{\"a}cker, Matthias and Schusser, Sebastian and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Multi-Parametererfassung mit siliziumbasiertem Sensorchip: Aus Drei mach Eins}, series = {GIT Labor-Fachzeitschrift}, journal = {GIT Labor-Fachzeitschrift}, number = {2}, publisher = {Wiley}, issn = {0016-3538}, pages = {28 -- 30}, year = {2014}, language = {de} } @article{HuckPoghossianBaeckeretal.2015, author = {Huck, Christina and Poghossian, Arshak and B{\"a}cker, Matthias and Reisert, Steffen and Kramer, Friederike and Begoyan, Vardges K. and Buniatyan, Vahe V. and Sch{\"o}ning, Michael Josef}, title = {Multi-parameter sensing using high-k oxide of barium strontium titanate}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431911}, pages = {1259}, year = {2015}, abstract = {High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors. In this work, a Si-based sensor chip containing Pt interdigitated electrodes covered with a thin BST layer (485 nm) has been developed for multi-parameter chemical sensing. The chip has been applied for the contactless measurement of the electrolyte conductivity, the detection of adsorbed charged macromolecules (positively charged polyelectrolytes of polyethylenimine) and the concentration of hydrogen peroxide (H2O2) vapor. The experimental results of functional testing of individual sensors are presented. The mechanism of the BST sensitivity to charged polyelectrolytes and H2O2 vapor has been proposed and discussed.}, language = {en} } @article{LaumannMainz2012, author = {Laumann, J{\"o}rg and Mainz, Stefan}, title = {Direkte Ermittlung der erforderlichen Einspanntiefe von I‑f{\"o}rmigen Stahlquerschnitten in Betonkonstruktionen}, volume = {81}, number = {11}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1049}, doi = {10.1002/stab.201201620}, pages = {850 -- 860}, year = {2012}, abstract = {F{\"u}r die Ermittlung der erforderlichen Einspanntiefe von eingespannten Stahlquerschnitten in Betonkonstruktionen existieren verschiedene Bemessungsmodelle. Diese basieren vorwiegend auf Grundlage nationaler Normen wie z. B. DIN 18800 [1] und DIN 1045 [2], die durch die europ{\"a}ische Normung ersetzt wurden. Aus diesem Grund wird in diesem Aufsatz ein Berechnungsmodell f{\"u}r die erforderliche Einspanntiefe von eingespannten Stahlquerschnitten in Betonkonstruktionen auf Grundlage des Eurocodes vorgestellt. Das Grundger{\"u}st f{\"u}r dieses Berechnungsmodell bildet das Verfahren nach Kindmann und Laumann, welches in [3] behandelt wurde. Gleichzeitig werden neue Formeln zur direkten Ermittlung der Mindesteinspanntiefe vorgestellt. Behandelt werden gewalzte I-Profile f{\"u}r einachsige Biegung um die starke Achse (y-y) mit Drucknormalkraft.}, language = {de} } @article{MuribGrinsvenGrietenetal.2013, author = {Murib, M. S. and Grinsven, B. van and Grieten, L. and Janssens, S. D. and Vermeeren, V. and Eersels, K. and Broeders, J. and Ameloot, Marcel and Michiels, L. and Ceuninck, W. De and Haenen, K. and Sch{\"o}ning, Michael Josef and Wagner, Patrick}, title = {Electronic monitoring of chemical DNA denaturation on nanocrystalline diamond electrodes with different molarities and flow rates}, series = {Physica Status Solidi (A). Vol. 210 (2013), iss. 5}, journal = {Physica Status Solidi (A). Vol. 210 (2013), iss. 5}, publisher = {Wiley-VCH}, address = {Berlin}, issn = {0031-8965}, pages = {911 -- 917}, year = {2013}, language = {en} } @article{ButenwegFehling2012, author = {Butenweg, Christoph and Fehling, Ekkehard}, title = {Hintergrund f{\"u}r die vereinfachten Regeln bei Mauerwerksgeb{\"a}uden im Erdbebenfall}, series = {Mauerwerk : European journal of masonry}, volume = {16}, journal = {Mauerwerk : European journal of masonry}, number = {3}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1022 (E-Journal); 1432-3427 (Print)}, doi = {10.1002/dama.201200537}, pages = {127 -- 137}, year = {2012}, abstract = {Bei der Ausarbeitung des nationalen Anwendungsdokumentes zur DIN EN 1998-1 waren die in der ENV-Fassung enthaltenen vereinfachten Regeln im Lichte aktueller Forschungsergebnisse zu {\"u}berpr{\"u}fen und zu {\"u}berarbeiten. Die gleiche Aufgabe stellte sich auch f{\"u}r die Neufassung der DIN 4149. In beiden F{\"a}llen sind neben konstruktiven Regeln f{\"u}r die Art und Anordnung der zur Geb{\"a}udeaussteifung heranzuziehenden W{\"a}nde im Grundriss Tabellen enthalten, die unter bestimmten Bedingungen den Entfall eines rechnerischen Nachweises der Tragw{\"a}nde im Erdbebenfall erm{\"o}glichen. Dies ist f{\"u}r Schwachbebengebiete, wie sie in Deutschland und anderen L{\"a}ndern Mitteleuropas anzutreffen sind, sinnvoll, um unn{\"o}tigen Rechenaufwand sowie Probleme mit der F{\"u}hrbarkeit von Nachweisen so weit wie m{\"o}glich auszuschalten. Im vorliegenden Beitrag werden die Hintergr{\"u}nde der vereinfachten Regeln diskutiert und die Ergebnisse der Anwendung mit verschiedenen Rechenverfahren verglichen und bewertet.}, language = {de} } @article{ButenwegGellert2012, author = {Butenweg, Christoph and Gellert, Christoph}, title = {Integrale Geb{\"a}udeplanung am Beispiel eines Geschossbaus in Ziegelmauerwerk}, series = {Mauerwerk : European journal of masonry}, volume = {16}, journal = {Mauerwerk : European journal of masonry}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1437-1022 (E-Journal); 1432-3427 (Print)}, doi = {10.1002/dama.201200550}, pages = {247 -- 254}, year = {2012}, abstract = {Moderne Mauerwerksbauten m{\"u}ssen nach heutigen Anforderungen architektonisch, statisch, energetisch sowie schall- und brandschutztechnisch optimal ausgelegt sein. Aufgrund der Komplexit{\"a}t und engen Verzahnung der einzelnen Anforderungen ist eine integrale Geb{\"a}udeplanung zur Erzielung einer qualitativ hochwertigen Bauwerksl{\"o}sung unbedingt notwendig. Diese erfordert von den Fachplanern vertieftes Spezialwissen in den verschiedenen Bereichen, um insbesondere die Schnittstellen und Bauwerksdetails korrekt zu planen und auszuf{\"u}hren. Der Beitrag stellt die integrale Geb{\"a}udeplanung am Beispiel eines Geschossbaus in Ziegelbauweise mit L{\"o}sungen f{\"u}r wesentliche Detailpunkte vor}, language = {de} } @article{BrockhausBehbahaniMurisetal.2021, author = {Brockhaus, Moritz K. and Behbahani, Mehdi and Muris, Farina and Jansen, Sebastian V. and Schmitz-Rode, Thomas and Steinseifer, Ulrich and Clauser, Johanna C.}, title = {In vitro thrombogenicity testing of pulsatile mechanical circulatory support systems: Design and proof-of-concept}, series = {Artificial Organs}, volume = {45}, journal = {Artificial Organs}, number = {12}, publisher = {Wiley}, address = {Weinheim}, issn = {1525-1594}, doi = {10.1111/aor.14046}, pages = {1513 -- 1521}, year = {2021}, abstract = {Thrombogenic complications are a main issue in mechanical circulatory support (MCS). There is no validated in vitro method available to quantitatively assess the thrombogenic performance of pulsatile MCS devices under realistic hemodynamic conditions. The aim of this study is to propose a method to evaluate the thrombogenic potential of new designs without the use of complex in-vivo trials. This study presents a novel in vitro method for reproducible thrombogenicity testing of pulsatile MCS systems using low molecular weight heparinized porcine blood. Blood parameters are continuously measured with full blood thromboelastometry (ROTEM; EXTEM, FIBTEM and a custom-made analysis HEPNATEM). Thrombus formation is optically observed after four hours of testing. The results of three experiments are presented each with two parallel loops. The area of thrombus formation inside the MCS device was reproducible. The implantation of a filter inside the loop catches embolizing thrombi without a measurable increase of platelet activation, allowing conclusions of the place of origin of thrombi inside the device. EXTEM and FIBTEM parameters such as clotting velocity (α) and maximum clot firmness (MCF) show a total decrease by around 6\% with a characteristic kink after 180 minutes. HEPNATEM α and MCF rise within the first 180 minutes indicate a continuously increasing activation level of coagulation. After 180 minutes, the consumption of clotting factors prevails, resulting in a decrease of α and MCF. With the designed mock loop and the presented protocol we are able to identify thrombogenic hot spots inside a pulsatile pump and characterize their thrombogenic potential.}, language = {en} } @article{RibitschHeumannTrotschaetal.2011, author = {Ribitsch, D. and Heumann, S. and Trotscha, E. and Herrero Acero, E. and Greimel, K. and Leber, R. and Birner-Gruenberger, R. and Deller, S. and Eiteljoerg, I. and Remler, P. and Weber, Th. and Siegert, Petra and Maurer, Karl-Heinz and Donelli, I. and Freddi, G. and Schwab, H. and Guebitz, G. M.}, title = {Hydrolysis of polyethyleneterephthalate by p-nitrobenzylesterase from Bacillus subtilis}, series = {Biotechnology progress}, volume = {Vol. 27}, journal = {Biotechnology progress}, number = {Iss. 4}, publisher = {Wiley}, address = {Hoboken}, issn = {1520-6033 (E-Journal); 8756-7938 (Print)}, pages = {951 -- 960}, year = {2011}, language = {en} }