@inproceedings{BallmannRaatschenStaat1985, author = {Ballmann, J. and Raatschen, Hans-J{\"u}rgen and Staat, Manfred}, title = {High stress intensities in focussing zones of waves}, doi = {10.1016/B978-0-444-42520-1.50015-3}, year = {1985}, abstract = {The propagation of mechanical waves in plates of isotropic elastic material is investigated. After a short introduction to the understanding of focussing of stress waves in a plate with a curved boundary the method of characteristics is applied to a plate of hyperelastic material. Using this method the propagation of acceleration waves is discussed. Based on this a numerical difference scheme is developed for solving initial-boundary-value problems and applied to two examples: propagation of a point disturbance in a homogeneously finitely strained non-linear elastic plate and geometrical focussing in al linear elastic plate.}, subject = {Technische Mechanik}, language = {en} } @inproceedings{Bruessermann2005, author = {Br{\"u}ssermann, Klaus}, title = {Platform of Excellence in "Energy and Environment"}, year = {2005}, abstract = {The Ministry of Science and Research in North Rhine-Westphalia created eight platforms of excellence, one in the research area „Energy and Environment" in 2002 at ACUAS. This platform concentrates the research and development of 13 professors in J{\"u}lich and Aachen and of two scientific institutes with different topics: - NOWUM-Energy with emphasis on efficient and economic energy conversion - The Solar Institute J{\"u}lich - SIJ - being the largest research institute in the field of renewables at a University of Applied Sciences in Germany With this platform each possible energy conversion - nuclear, fossil, renewable- can be dealt with to help solving the two most important problems of mankind, energy and potable water. At the CSE are presented the historical development, some research results and the combined master studies in „Energy Systems" and „Nuclear Applications"}, subject = {Energietechnik}, language = {en} } @inproceedings{BruessermannDeuster2005, author = {Br{\"u}ssermann, Klaus and Deuster, M.}, title = {Temperature measurement to optimise the burning process}, year = {2005}, abstract = {One of the most important parameters in a burning chamber - in power stations, in waste to energy plants - is the temperature. This temperature is in the range of 700-1500 °C - one of the most advanced measuring methods being the acoustic pyrometry with the possibility of producing temperature mapping in one level of the burning chamber - comparable to computer tomography. The results of these measurements discussed in the presentation can be used - to fulfil the legal requirements in the FRG or in the EU - to equalise the temperature in one level of the burning chamber to optimise the steam production (better efficiency of the plant) and to minimise the production of temperature controlled flue gas components (NO, CO a. o.) - to control the SNCR-process if used.}, subject = {Pyrometrie}, language = {en} } @inproceedings{DigelTemizArtmannArtmannetal.2003, author = {Digel, Ilya and Temiz Artmann, Ayseg{\"u}l and Artmann, Gerhard and Nojima, H.}, title = {Plasma cluster ions (PCI) influence on microbial cells viability : [abstract]}, year = {2003}, abstract = {Recently, SHARP corporation has developed the world's first "Plasma Cluster Ions (PCI)" air purification technology, which uses plasma discharge to generate cluster ions. The new plasma cluster device releases into the air positive and negative ions, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. A lot of phenomenological tests of the PCI air purification technology on microbial cells have been conducted. And, in most cases, it has been shown that PCI demonstrate strongly pronounced killing effect. Although, the particular mechanisms of PCI action are still not evident. We studied variations in resistance to PCI among gram-positive airborne microorganisms, as well as some dose-dependent, spatial, cultural and biochemical properties of PCI action in respect of Staphylococcus spp, Enterococcus spp, Micrococcus spp.}, subject = {Clusterion}, language = {en} } @inproceedings{DigelTemizArtmannNojimaetal.2003, author = {Digel, Ilya and Temiz Artmann, Ayseg{\"u}l and Nojima, H. and Artmann, Gerhard}, title = {Plasma-generated cluster ions' effects on indoor microflora : [abstract]}, year = {2003}, abstract = {Recently, SHARP corporation has developed the world's first "Plasma Cluster Ions® (PCI)" air purification technology, which uses plasma discharge to generate cluster ions. The new Plasma Cluster Device releases positive and negative ions into the air, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. In the past, phenomenological tests on the efficacy of the PCI air purification technology on microbial cells have been conducted. In most cases, it has been shown that PCI demonstrated strongly pronounced killing effects on microorganisms. However, the particular mechanisms of PCI action still have to be uncovered.}, subject = {Clusterion}, language = {en} } @inproceedings{DigelTemizArtmannNojimaetal.2003, author = {Digel, Ilya and Temiz Artmann, Ayseg{\"u}l and Nojima, H. and Artmann, Gerhard}, title = {Some peculiarities of application of cluster ions generated by plasma in respect of indoor air purification :[abstract]}, year = {2003}, abstract = {Recently, the SHARP Corporation, Japan, has developed the world's first "Plasma Cluster Ions (PCI)" air purification technology using plasma discharge to generate cluster ions. The new plasma cluster device releases positive and negative ions into the air, which are able to decompose and deactivate harmful airborne substances by chemical reactions. Because cluster ions consist of positive and negative ions that normally exist in the natural world, they are completely harmless and safe to humans. The amount of ozone generated by cluster ions is less than 0.01 ppm, which is significantly less than the 0.05-ppm standard for industrial operations and consumer electronics. This amount, thus, has no harming effects whatsoever on the human body. But particular properties and chemical processes in PCI treatment are still under study. It has been shown that PCI in most cases show strongly pronounced irreversible killing effects in respect of airborne microflora due to free-radical induced reactions and can be considered as a potent technology to disinfect both home, medical and industrial appliances.}, subject = {Clusterion}, language = {en} } @inproceedings{HeitzerStaat2000, author = {Heitzer, M. and Staat, Manfred}, title = {Direct FEM approach to design-by-analysis of pressurized components}, year = {2000}, abstract = {Abstracts of the ACHEMA 2000 - International Meeting on Chemical Engineering, Environmental Protection and Biotechnology, May 22 - 27, 2000. Frankfurt am Main. Achema 2000 : special edition / Linde. [Ed.: Linde AG. Red.: Volker R. Leski]. - Wiesbaden : Linde AG, 2000. - 56 p. : Ill., . - pp: 79 - 81}, subject = {Finite-Elemente-Methode}, language = {en} } @inproceedings{KernDikta2009, author = {Kern, Alexander and Dikta, Gerhard}, title = {Probability of damage of electrical and electronic systems due to indirect lightning flashes - investigation of data from German insurance companies}, year = {2009}, abstract = {In the presented paper data collected from the field related to damage statistics of electrical and electronic apparatus in household are reported and investigated. These damages (total number approx. 74000 cases), registered by five German insurance companies in 2005 and 2006, were adviced by customers as caused by lightning overvoltages. With the use of stochastical methods it is possible, to reasses the collected data and to distinguish between cases, which are with high probability caused by lightning overvoltages, and those, which are not. If there was an indication for a direct strike, this case was excluded, so the focus was only on indirect lightning flashes, i.e. only flashes to ground near the structure and flashes to or nearby an incoming service line were investigated. The data from the field contain the location of damaged apparatus (residence of the policy holder) and the distances of the nearest cloud-to-ground stroke to the location of the damage registered by the German lightning location network BLIDS at the date of damage. The statistical data along with some complementary numerical simulations allow to verify the correspondence of the Standards rules used for IEC 62305-2 with the field data and to define some correction needs. The results could lead to a better understanding whether a damage reported to an insurance company is really caused by indirect lightning, or not.}, subject = {Blitzschutz}, language = {en} } @inproceedings{KirchhofKraft2004, author = {Kirchhof, M. and Kraft, Bodo}, title = {UML-based modeling of architectural knowledge and design}, year = {2004}, abstract = {IASSE-2004 - 13th International Conference on Intelligent and Adaptive Systems and Software Engineering eds. W. Dosch, N. Debnath, pp. 245-250, ISCA, Cary, NC, 1-3 July 2004, Nice, France We introduce a UML-based model for conceptual design support in civil engineering. Therefore, we identify required extensions to standard UML. Class diagrams are used for elaborating building typespecific knowledge: Object diagrams, implicitly contained in the architect's sketch, are validated against the defined knowledge. To enable the use of industrial, domain-specific tools, we provide an integrated conceptual design extension. The developed tool support is based on graph rewriting. With our approach architects are enabled to deal with semantic objects during early design phase, assisted by incremental consistency checks.}, subject = {UML}, language = {en} } @inproceedings{Kraft2004, author = {Kraft, Bodo}, title = {Conceptual design tools for civil engineering}, year = {2004}, abstract = {Applications of Graph Transformations with Industrial Relevance Lecture Notes in Computer Science, 2004, Volume 3062/2004, 434-439, DOI: http://dx.doi.org/10.1007/978-3-540-25959-6_33 This paper gives a brief overview of the tools we have developed to support conceptual design in civil engineering. Based on the UPGRADE framework, two applications, one for the knowledge engineer and another for architects allow to store domain specific knowledge and to use this knowledge during conceptual design. Consistency analyses check the design against the defined knowledge and inform the architect if rules are violated.}, subject = {CAD}, language = {en} }